    Have a look at the manual Panasonic Digital Business System Section 300 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 790
    							Installation, Section 300 
    Issue 2 Trunks and Lines 
    August 16,1993 
    3. 
    Attach the Sync Unit to the CPC-B card. 
    Note: Before attaching the Sync Unit, insert the three spacers provided with 
    the unit and remove the jumpers from CN2 of the CPC-B card. 
    Figure 4-4. 
    TI Sync Unit instuilan’on 
    BPU Chip 
    (Version 1.3 
    or higher) 
    f 
    4-20  
    						
    							Installation, Section 300 
    Issue 2 Trunks and Lines 
    August 16,1993 
    F 
    4. Install the Tl MDF (main distribution frame) card in the top of the cabinet as 
    shown in Figure 4-5. 
    re 4-5. TI MI)F card installation 
    To Ground Screw 
    4-21  
    						
    							Installation, Section 300 
    Issue 2 Trunks and Lines 
    August- 16, 1993 
    5. Set SW 1 on the Tl card according to the following table. 
    These switch settings correspond to the distance between the DBS and 
    the 
    CSU. 
    To turn a switch on, flip it to the “up” position_ 
    Table 4-18. Switch seaings for S WI on the Tl card 
    Fi 
    SW 
    1 SW1 
    I+ 
    1 SW6 
    0 to 150 ft. 
    Distancefiom the DBS to the CSV 
    I 150-450 ft. 
    1 450-655 ft. 
    On Off 
    Off 
    Off On 
    Off 
    Off Off 
    On 
    Off 
    On Off 
    Off Off On 
    Off On 
    Off Off 
    Not used 
    Not used Off 
    On 
    Not 
    used 
    6. Install the Tl card in the “ECmRK” slot 
    f 
    7. Connect the Sync Cable from CNl on the Sync Unit to CN5 on the Tl card. 
    re 4-6. Sync Unit and Tl connection, single-cabinet instalbtion 
    8. Connect the cable attached to CN3 on the Tl MDF card to CN3 on the Tl 
    card (Figure 4-8). 
    4-22  
    						
    							Installation, Section 300 Trunks and Lines 
    Issue 2 August 16, 1993 
    9. Using an RJ48 cable, connect CNI on the Tl MDF card to the CSU (Figure 
    4-8).?‘he following illustration shows CN 
    1 pinouts. 
    Figure 4-7 RJ48 pin uts, CNI connector 
    . 
    0 0 0 0 
    l-b1 Rlna NC FG 
    0 0 0 0 
    Ring 1 NC nP FG 
    CN 1 (RJ48) 
    4-23  
    						
    							Installation, Section 300 
    issue 2 
    Trunks and Lines 
    August 
    16,1993 
    10. Connect the ground cable from the TI MDF card to the cabinet as shdwn in 
    Figure 4-8. 
    [gum 4-8. TI cabinet connecdons, single-cabinet instihtion 
    I RKtTlwRut9E!ztEc2Et3Ec4EcsEc6Ec7EcaEmrsx/mNlx 
    T-l Line 
    Q 
    csu 
    - Sync Unit 
    ____ 
    -0 
    ’ 
    CN3 
    . 
    CNl 
    y 
    T-l Card 
    - CNS 
    -Sync Cable 
    f 
    4-24  
    						
    							Installation, Section 300 
    Trunks and Lines 
    Issue 2 August 16, 1993 
    Installing Tl in a Double Cabinet with the Tl in the Slave 
    1. Before beginning Tl installation, perform the “New Function Reset” 
    command (FFl 8# l# (0- I)#). This 
    command must be issued before the Tl 
    can be installed properly. 
    2. 
    3. 
    4. 
    5. 
    6. 
    7. 
    8. 
    9. Install the Sync Unit in the master cabinet as described in Steps 2 and 3 under 
    “Installation for a Single Tl.” 
    install a Tl MDF card in the slave cabinet. (See Step 4 on page 4-21.) 
    Set Switch 1 on the Tl card. (See Step 5 on page 4-22.) 
    install a Tl card in the “EC/TRK” slot of the slave cabinet. 
    Connect the Sync Cable from CNl on the Sync Unit to CN5 on the Tl card 
    (Figure 4-9). 
    Note: Part Number VB-43564 is used for the Sync Cable when a Tl is 
    installed only in the slave cabinet of a two-cabinet system. 
    At the slave cabinet, connect the cable attached to CN3 on the Tl MDF card 
    to CN3 on the Tl card (Figure 4-8). 
    Using an RJ48 cable, connect CNl of the Tl MDF card to the CSU. (See 
    Figure 4-7 on page 4-23 for RJ48 pinouts.) 
    At the slave cabinet, connect the ground cable on the Tl MDF card as shown 
    in Figure 4-8 on page 4-24. 
    4-25  
    						
    							Installation, Section 300 
    Issue 2 Trunks and Lines 
    August 16,1993 
    gure 4-9. Sync cable connections, double-cabinet with a Tl in the slave 
    Card 
    Labe’ Guide 
    < 
    I Slave Cabinet /T-l MDF 
    Master Cabinet 
    Card 
    Labe 
    lots: The number of analog trunks thst can ba 
    installed depends on how msny 11 chsnneIr us 
    used. 
    43 
    CN5 
    nterconnection 
    Cables 
    4-26  
    						
    							Installation, Section 300 
    issue 2 
    , Installing Tl in a Double Cabinet with Tls in the Master and Slave 
    1. 
    2. 
    3. 
    4. 
    5. 
    6. 
    7. 
    8. 
    9. 
    Before beginning Tl installation, perform the “New Function Reset” 
    command (FFI 8# l# (0-I)#). This command must be issued before the Tl 
    can be installed properly. 
    Install the Sync Unit in the master cabinet as described in Steps 2 and 3 under 
    “Installation for a Single Tl.” 
    install a Tl MDF card in each cabinet. (See Step 4 on page 4-2 1.) 
    Set Switch 1 on the Tl cards. (See Step 5 on page 4-22.) 
    Install a Tl card in each “ECYTRK” slot. 
    Connect the Clock Sync Cable from .CN4 on the master-cabinet Tl to CN5 
    on the slave-cabinet 
    Tl , as shown in Figure 4-10. 
    Note: Part Number VB-43564 is used for the Clock Sync Cable when Tls are 
    installed in the master and slave cabinets. 
    At the master cabinet, connect the Sync Cable from CN 1 on the Sync Unit to 
    CN5 on the Tl card (Figure 4-10). 
    At each cabinet, connect the cable attached to CN3 on the Tl MDF card to 
    CN3 on the Tl 
    card (Figure 4-8). 
    Using an RJ48 cable, connect CN 1 of each Tl MDF card to a CSU. (See 
    Figure 4-7 on page 4-23 for RJ48 pinouts.) 
    10. For both cabinets, connect the ground cable from the Tl MDF card as shown 
    in Figure 4-8 on page 4-24. 
    4-27  
    						
    							Installation, Section 300 
    Issue 2 
    Fieure 4-10. Clock svnc cable and svnc cable connections. double-cabinet installation 
    Trunks and Lines 
    August 16, 1993 
    f :. 
    Label Card  
    Card Label 
     
    Master Cabinet 
    note: me number 01 analog trunks that ran be 
    s.led depends on how many Tl channels are 
    f 
    4-28  
    						
    							i \: 
    Installation, Section 300 
    Issue 2 
    Lines 
    Trunks and Lines 
    August 16, 1993 
    Extension Connectors 
    The number of extension ports that can be connected to your system depends on 
    the type of system you have. Figure 4- 11 shows the maximum number of 
    extensions that can be connected to each system when the extension expansion 
    connector is used. 
    Table 4-l summarizes the number of ports that can be used without the 
    extension expansion connector. Chapter 6 includes extension maximums for 
    two-cabinet systems. 
    igure d-11. DBS extension connections 
    Extension Expansion Connedof 
    j=- MDF 
    I To CNl on tba Extension Expansion Connedor 
    To 
    CN12 
    To CN13 
    To Extension 32 
    Extension 1 
    Extension 24 
    Extension 25 
    Extension 48 
    Extension 49 
    Extension 72 D&i 72 
    3. 
    and 96 
    3 
    DES 96 
    only 
    4-29  
    						