Have a look at the manual Panasonic Digital Business System Section 300 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 3. Attach the Sync Unit to the CPC-B card. Note: Before attaching the Sync Unit, insert the three spacers provided with the unit and remove the jumpers from CN2 of the CPC-B card. Figure 4-4. TI Sync Unit instuilan’on BPU Chip (Version 1.3 or higher) f 4-20
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 F 4. Install the Tl MDF (main distribution frame) card in the top of the cabinet as shown in Figure 4-5. re 4-5. TI MI)F card installation To Ground Screw 4-21
Installation, Section 300 Issue 2 Trunks and Lines August- 16, 1993 5. Set SW 1 on the Tl card according to the following table. These switch settings correspond to the distance between the DBS and the CSU. To turn a switch on, flip it to the “up” position_ Table 4-18. Switch seaings for S WI on the Tl card Fi SW 1 SW1 I+ 1 SW6 0 to 150 ft. Distancefiom the DBS to the CSV I 150-450 ft. 1 450-655 ft. On Off Off Off On Off Off Off On Off On Off Off Off On Off On Off Off Not used Not used Off On Not used 6. Install the Tl card in the “ECmRK” slot f 7. Connect the Sync Cable from CNl on the Sync Unit to CN5 on the Tl card. re 4-6. Sync Unit and Tl connection, single-cabinet instalbtion 8. Connect the cable attached to CN3 on the Tl MDF card to CN3 on the Tl card (Figure 4-8). 4-22
Installation, Section 300 Trunks and Lines Issue 2 August 16, 1993 9. Using an RJ48 cable, connect CNI on the Tl MDF card to the CSU (Figure 4-8).?‘he following illustration shows CN 1 pinouts. Figure 4-7 RJ48 pin uts, CNI connector . 0 0 0 0 l-b1 Rlna NC FG 0 0 0 0 Ring 1 NC nP FG CN 1 (RJ48) 4-23
Installation, Section 300 issue 2 Trunks and Lines August 16,1993 10. Connect the ground cable from the TI MDF card to the cabinet as shdwn in Figure 4-8. [gum 4-8. TI cabinet connecdons, single-cabinet instihtion I RKtTlwRut9E!ztEc2Et3Ec4EcsEc6Ec7EcaEmrsx/mNlx T-l Line Q csu - Sync Unit ____ -0 ’ CN3 . CNl y T-l Card - CNS -Sync Cable f 4-24
Installation, Section 300 Trunks and Lines Issue 2 August 16, 1993 Installing Tl in a Double Cabinet with the Tl in the Slave 1. Before beginning Tl installation, perform the “New Function Reset” command (FFl 8# l# (0- I)#). This command must be issued before the Tl can be installed properly. 2. 3. 4. 5. 6. 7. 8. 9. Install the Sync Unit in the master cabinet as described in Steps 2 and 3 under “Installation for a Single Tl.” install a Tl MDF card in the slave cabinet. (See Step 4 on page 4-21.) Set Switch 1 on the Tl card. (See Step 5 on page 4-22.) install a Tl card in the “EC/TRK” slot of the slave cabinet. Connect the Sync Cable from CNl on the Sync Unit to CN5 on the Tl card (Figure 4-9). Note: Part Number VB-43564 is used for the Sync Cable when a Tl is installed only in the slave cabinet of a two-cabinet system. At the slave cabinet, connect the cable attached to CN3 on the Tl MDF card to CN3 on the Tl card (Figure 4-8). Using an RJ48 cable, connect CNl of the Tl MDF card to the CSU. (See Figure 4-7 on page 4-23 for RJ48 pinouts.) At the slave cabinet, connect the ground cable on the Tl MDF card as shown in Figure 4-8 on page 4-24. 4-25
Installation, Section 300 Issue 2 Trunks and Lines August 16,1993 gure 4-9. Sync cable connections, double-cabinet with a Tl in the slave Card Labe’ Guide < I Slave Cabinet /T-l MDF Master Cabinet Card Labe lots: The number of analog trunks thst can ba installed depends on how msny 11 chsnneIr us used. 43 CN5 nterconnection Cables 4-26
Installation, Section 300 issue 2 , Installing Tl in a Double Cabinet with Tls in the Master and Slave 1. 2. 3. 4. 5. 6. 7. 8. 9. Before beginning Tl installation, perform the “New Function Reset” command (FFI 8# l# (0-I)#). This command must be issued before the Tl can be installed properly. Install the Sync Unit in the master cabinet as described in Steps 2 and 3 under “Installation for a Single Tl.” install a Tl MDF card in each cabinet. (See Step 4 on page 4-2 1.) Set Switch 1 on the Tl cards. (See Step 5 on page 4-22.) Install a Tl card in each “ECYTRK” slot. Connect the Clock Sync Cable from .CN4 on the master-cabinet Tl to CN5 on the slave-cabinet Tl , as shown in Figure 4-10. Note: Part Number VB-43564 is used for the Clock Sync Cable when Tls are installed in the master and slave cabinets. At the master cabinet, connect the Sync Cable from CN 1 on the Sync Unit to CN5 on the Tl card (Figure 4-10). At each cabinet, connect the cable attached to CN3 on the Tl MDF card to CN3 on the Tl card (Figure 4-8). Using an RJ48 cable, connect CN 1 of each Tl MDF card to a CSU. (See Figure 4-7 on page 4-23 for RJ48 pinouts.) 10. For both cabinets, connect the ground cable from the Tl MDF card as shown in Figure 4-8 on page 4-24. 4-27
Installation, Section 300 Issue 2 Fieure 4-10. Clock svnc cable and svnc cable connections. double-cabinet installation Trunks and Lines August 16, 1993 f :. Label Card Card Label Master Cabinet note: me number 01 analog trunks that ran be s.led depends on how many Tl channels are f 4-28
i \: Installation, Section 300 Issue 2 Lines Trunks and Lines August 16, 1993 Extension Connectors The number of extension ports that can be connected to your system depends on the type of system you have. Figure 4- 11 shows the maximum number of extensions that can be connected to each system when the extension expansion connector is used. Table 4-l summarizes the number of ports that can be used without the extension expansion connector. Chapter 6 includes extension maximums for two-cabinet systems. igure d-11. DBS extension connections Extension Expansion Connedof j=- MDF I To CNl on tba Extension Expansion Connedor To CN12 To CN13 To Extension 32 Extension 1 Extension 24 Extension 25 Extension 48 Extension 49 Extension 72 D&i 72 3. and 96 3 DES 96 only 4-29