    Have a look at the manual Panasonic Digital Business System Section 300 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 790
    							installation, Section 300 
    Double-Cabinet Systems 
    Issue 2 
    August 
    l&1993 
    Guidelines 
    Two DBS cabinets can be connected to increase linesize. The maximum 
    linesize consists of two DBS 96 cabinets, which provide 192 ports. 
    CPC-B and SCC-B are required for two-cabinet systems. 
    If ground start or DID trunks are used in both cabinets, separate -48V 
    supplies must be supplied for each cabinet. If SLTs are used in both cabinets, 
    separate SLT ringer boxes must be supplied for each cabinet. 
    The following table shows the acceptable combinations of system types 
    Table 6-1. Trunk and extension port maximums for double-cabinet systems 
    Expansion Ports 
    k lines or exten- 
    Notes: 
    1. The slave cabinet must be used for expansion ports. 
    2. When a DBS72 and DBS40 are connected, expansion ports cannot be used. 
    l Figures 6- 1 through 6-6 shows slot usage for two-cabinet combinations. 
    6-3  
    						
    							Installation, Section 300 Double-Cabinet Systems 
    Issue 2 
    August 16, 1993 
    i 
    Figure 6-I. Slot usage for two-cabinet systems, DBS 40 + DBS 40 
    DBS 40 (Slave) 
    TRKl EC1 EC2 EC3 EC/TRK SCC CPC AUXl AUX2 
    5 
    DBS 40 (Master) 
    *See “Tl Interface” on page 4-9 for EC/TRK port numbers for Tl. 
    #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit 
    Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave 
    AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in 
    the CPC slot and one in AUX 1. (When two MFR cards are used, Strap S3 on the second card 
    must be cut.) 
    6-4  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet Systems 
    August 
    16,1993 
    Figure 6-2. Slot usage for two-cabinet systems, DBS 72 + DBS 40 
    DBS 40 (Slave) 
    TRKl EC1 EC2 EC3 EC/TRK SCC CPC AUXI AUX2 
    xl 
    G + G Y 
    8 
    z t- s; 
    z 
    ik ir 9 
    f t: ii ; $ 
    ? ii 
    z 
    2% 0 
    Notes: DBS 72 (Master) 
    TRK 
    EC5 EC6 
    I I 
    EC/ 
    TRK 
    *A maximum of two MFR cards can be installed in a two-cabinet system.Wlth Cable Kit 
    Version 1.1, one MFR is installed in the 
    Master AUXl, and one MFR is installed in the Slave 
    AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in 
    the CPC slot and one in AUXI. (When two MFR cards are used, Strap S3 on the second card 
    must be cut) 
    6-5  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet 
    Systems 
    August 1.6, 1993 
    Figure 6-3. Slot usage for two-cabinet systems, DBS 72 + DBS 72 
    DBS 72 (Slave) 
    DBS 72 (Master) 
    TRK1 TRK2 EC1 EC2 EC3 EC4 EC5 EC6 EC/TRK SCC CPC AUXl AUX2 
    Notes: 
    YSee 
    “Tl Interface” on page 4-9 for EC/TRK port numbers for Tl. 
    Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for trunks 
    or lines. Prior to CPC-B Version 4, this slot could only be used for lines. 
    ,‘A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit 
    Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave 
    AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in 
    the CPC slot and one in AUX 1. (When two MFR cards are used, Strap S3 on the second card 
    must be cut) 
    6-6  
    						
    							installation, Section 300 Double-Cabinet Systems 
    Issue 2 August 16,1993 
    Figure 64. Slot usage for two-cabinet systems, DBS 96 + DBS 40 
    DBS 40 (Slavej 
    DBS 96 (Master) 
    *See “Tl Interface*’ on page 4-9 for EC/IRK port numbers for Tl. 
    “A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit 
    Version 1.1, one MFR is installed in the Master AUX 1, and one MFR is installed in the Slave 
    AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in 
    the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card 
    must be cut) 
    6-7  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet Systems 
    August 16,1993 
    Figure 6-5. Slot usage for two-cabinet systems, DBS 96 + DBS 72 
    DBS 72 (Slave) 
    TRKl TRKZ EC1 EC2 EC3 EC4 EC5 EC6 EC/TRK SCC CPC AUXl AUX2 
    DBS 96 (Master) 
    TRKl TRK2 TRK3 EC1 EC2 EC3 EC4 EC5 EC6 EC7 EC8 EC/TRK SCC CPC AUXl AUX2 
    b 
    *See “Tl Interface” on page 4-9 for EC/IRK port numbers for Tl. 
    #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit 
    Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave 
    AUX 1. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in 
    the CPC slot and one in 
    AUXl . (When two MFR cards are used, Strap S3 on the second card 
    must be cut) 
    6-8  
    						
    							I 
    EXT l-8 
    EXT 17-24 
    F EXT 25-32 
    TRK 25-32* or 
    CBL-M TRK 
    33-40 
    I I  5;1 
    x 
    EXT 81-88 g I I N 
    EXT89-96 8 
    cd 
    EXT 97-l 04 
    B 
    EXT 105-112 ; 
    EXT 113-120 % 
    Q, 
    EXT 121-128 $ 
    EXT 129-136 ; 
    TRK 57-64* or 5 
    ,,,,  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet Systems 
    August 16,1993 
    Installation 
    1. Install the trunk and extension cards according to the layouts shown in the 
    Figures 6- 1 through 6-6. 
    Note that the port numbers for each slot are fixed. 
    2. If you’re using two MFR cards, cut Strap S3 on the second card. 
    Figure 6-7. Strap 3, MFR card 
    i 
    3. Using the cables provided, connect the CBL-M card in the master cabinet to 
    the CBL-S card installed in the slave cabinet. 
    ( 
    Note: The EM1 filter must be instalkd less than 3/S inches from the right 
    sides of both the master and slave CBL cards. 
    6-10  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet Systems 
    August 16,1993 
    Figure 6-8. Double-cabinet installation 
    Digital Deskset 
    Pmgramming ~01-10 
    Stave Cabinet 
    SMDR Printer 
    Master Cabinet 
    4. Connect two 24V power supply cords from the CE3L-S card to the 24V and 
    GND terminals on CN2 of the Connector Panel of the slave cabinet. 
    Figure 6-9. CBL-S to Connector Panel connection, slave cabinet 
    CBL-S 
    CARD 
    6-l 1  
    						
    							Installation, Section 300 
    Issue 2 Double-Cabinet Systems 
    August 16,1993 
    5. Set SW 1 on the CBL-M card according to the following table. 
    Table 6-2. CBL-M switch settings 
    System Combinations 
    Switch Settings 
    Master Slave 1 2 3 4 5 6 7 8 
    DBS40 DBS40 
    ON ON ON ON ON ON OFF ON 
    DBS72 DBS40 
    ON OFF ON ON ON ON OFF OF@ 
    DBS72 DBS72 ON OFF ON OFF ON OFF ON OFF 
    DBS96 DBS40 OFF ON OFF ON ON OFF OFF OFF 
    DBS96 DBS72 OFF ON OFF ON ON OFF OFF OFF 
    DBS96 DBS96 OFF ON OFF ON ON OFF OFF OFF 
    f- 
    6-l 2  
    						