Home > NEC > Communications System > NEC Neax2000 Ivs Feature Programming Manual

NEC Neax2000 Ivs Feature Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax2000 Ivs Feature Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 479
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 4
    Revision 2.0
    ANNOUNCEMENT SERVICE
    To provide an Internal Recorded Message from a Digital Announcement Trunk (PN-2DATA) in place of Music On
    Hold:
    DESCRIPTION DATA
    Assign a Digital Announcement Trunk Circuit 
    No. to the required LEN.
    Note:The Digital Announcement Trunk
    Circuit No. must be assigned to the
    first LEN (Level 0) and/or the third
    LEN (Level 2) of each LT slot.(1) LEN (0000-0511) 
    (2) EB000-EB127:  Digital Announcement 
    Trunk Circuit No.
    For PIM0/1: EB000-EB031 
    For PIM2/3: EB032-EB063
    For PIM4/5: EB064-EB095
    For PIM6/7: EB096-EB127 
    Define the type of call to be provided with 
    Hold Message. •Y = 0
    (1) 00:  C.O. Line Call 
    01:  Tie Line Call 
    02:  Internal Call
    (2) 0500:  Hold Message
    Assign the function of the Digital 
    Announcement Trunk to Hold Message 
    Service.• YY = 00
    (1) 000-127 : Digital Announcement Trunk 
    Circuit No. assigned by CM10 (EB000-
    EB127)
    (2) 05XX
     :  For Hold Message Service 
    *a: Message No. (00-63) 
    • YY = 05
    (1) 00-63: Tenant No. 
    (2) 00-63: Message No. assigned by YY = 
    00
    To record, replay, or delete a message, assign 
    the respective Digital Announcement Trunk 
    access code. • Y = 0-3 (Number Plan Group 0-3)
    (1) X-XXX (Access Code) 
    (2) A00:  Record 
    A01:  Replay 
    A02:  Delete 
    CM10 START
    END
    CM48
    CM49
    CM20
    *a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 35
    Revision 2.0
    ANNOUNCEMENT SERVICE
    Note 6:A voice message in place of Music-On-Hold can be provided when a call has been placed on hold.
    -Different messages can be programmed on a tenant basis.
    - Different messages can be programmed, depending on the type of line (CO line, Tie line or station) on
    Hold.
    - More than one connection can be made to a Digital Announcement Trunk Circuit. Only the first connec-
    tion can be assured of hearing the message from the beginning.
    - Announcements will be repeated until the call is removed from hold. 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 6
    Revision 2.0
    ANNOUNCEMENT SERVICE
    To provide the Night Announcement by Digital Announcement Trunk (PN-2DATA)
    DESCRIPTION DATA
    Assign each Digital Announcement Trunk 
    Circuit No. to the required LEN.
    Note:The Digital Announcement Trunk
    Circuit No. must be assigned to the
    first LEN (Level 0) and/or the third
    LEN (Level 2) of each LT slot.(1) LEN (0000-0511)
    (2) EB000-EB127:  Digital Announcement 
    Trunk Circuit No.
    For PIM0/1: EB000-EB031
    For PIM2/3: EB032-EB063 
    For PIM4/5: EB064-EB095 
    For PIM6/7: EB096-EB127 
    Assign the Digital Announcement Trunk 
    Circuit No. to each incoming trunk.• YY = 03
    (1) 000-255:  Trunk No.
    (2) 04:  Direct-In Termination
    • YY = 05
    (1) 000-255 : Trunk No.
    (2) EB000-EB127 : Digital Announcement 
    Trunk Circuit No. assigned by CM10.
    Assign the function of the Digital 
    Announcement Trunk to Night 
    Announcement.• YY = 00
    (1) 000-127 : Digital Announcement Trunk 
    Circuit No. assigned by CM10. (EB000-
    EB127)
    (2) 03000 : For Night Announcement Ser-
    vice
    Specify the duration of a Night 
    Announcement.•Y = 0
    (1) 45
    (2) 01-99: 4 -396 sec. in 4sec. increments
    If no data is set, the default setting is 60-64 
    seconds.
    To record, replay, or delete a message, assign 
    the respective Digital Announcement Trunk 
    Circuit access code. • Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code
    (2) A00:  Record 
    A01:  Replay 
    A02:  Delete 
    CM10 START
    END
    CM30
    CM49
    CM41
    CM20 
    						
    							ND-45670 (E) CHAPTER 2
    Page 37
    Revision 2.0
    ANNOUNCEMENT SERVICE
    Note 7:A voice message can be sent to incoming C.O. lines during night mode. 
    - Different messages can be programmed on each C.O. line.
    - The voice message can be programmed for day/night. 
    - More than one connection can be made to a Digital Announcement Trunk Circuit. Only the first con-
    nection can be assured of hearing the message from the beginning.
    - Announcements may be programmed to be repeated from 4 to 120 seconds in four-second increments.
    HARDWARE REQUIRED 
    Digital Announcement Trunk (PN-2DATA). 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 8
    Revision 2.0
    ANSWER KEY
    PROGRAMMING
    Note:An ANSWER key is initially assigned on each Multiline Terminal. 
    HARDWARE REQUIRED 
    ETJ-8-1/ETJ-16DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/PN-4DLCA card.
    DESCRIPTION DATA
    Assign the Class of Service for this feature to 
    the required Multiline Terminals. • CM12 YY = 02 
    (1) X-XXXX:  Primary Extension No. 
    (2) XX XX
     
    *a: Service Restriction Class (B):  00-
    15
    • CM15 YY = 72 
    (1) XX : Service Restriction Class (B) as-
    signed by CM12 YY = 02
    (2) 0 : Allowed
    START
    END
    CM12
    CM15*a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 39
    Revision 2.0
    ATTENDANT-ASSISTED CALLING
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Access code for an operator call. • Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code (0) 
    (2) 800 
    Allocate the ATTCON Group No. to each 
    SN610 ATTCON. • YY = 00
    (1) 0-7:  ATTCON No. assigned by CM10. 
    (2) 0-3:  ATTCON Group No. 
    Assign the Master ATTCON within the 
    ATTCON Group. • YY = 01
    (1) 0-7:  ATTCON No.
    (2) 0/1 :  Master/Sub
    Specify the tenants to be handled by each ATT 
    Group.• Y = 0-3 (ATTCON Group No.0-3 as-
    signed by CM60 YY = 00)
    (1) 00-63 : Tenant No. 
    (2) 0 : To be handled
    Specify the Attendant access (ATTCON No. 
    0) capability provided from the stations 
    belonging to a tenant with no SN610 
    ATTCON.(1) 142 
    (2) 0/1 :  Allowed/Restricted 
    Provide the system with Passing Dial Tone. (1) 048 
    (2) 1 :  To be provided
    Provide the system with Attendant Night 
    Transfer, if required.(1) 018 
    (2) 0/1 :  Not to be provided/Provided 
    Specify the Individual Attendant access 
    capability provided from a station belonging 
    to a different tenant. (1) 143 
    (2) 0/1 :  Restricted/AllowedCM20 START
    END
    CM60
    CM62
    CM08
    INITIAL
    INITIAL 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 0
    Revision 2.0
    ATTENDANT CAMP-ON
    PROGRAMMING
    To reenter a Camped-On trunk from an Attendant before Automatic Recall (1200 Series Enhancement):
    To display the busy station number and name on an Attendant Console when reentering a Camped-On trunk by de-
    pressing the loop key (1200 Series Enhancement):
    DESCRIPTION DATA
    Specify the Camp-On Tone sent to busy 
    station.(1) 068 
    (2) 0 : Camp-on Tone is sent out only once.
    1  :  Camp-on Tone is repeated at an 
    interval of 4 seconds.
    Specify the recall timing of Camp-On. • Y = 0 
    (1) 00
    (2) 01-14: 2.4-33.6 sec. in 2.4 sec. 
    increments
    15-24: 38.4-124.8 sec. in 9.6 sec. 
    increments
    If no data is set, the default setting is 31.2-33.6 
    seconds.
    DESCRIPTION DATA
    Assign the access code for Call Pickup - 
    Direct.• Y=0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 021: Call Pickup - Direct
    DESCRIPTION DATA
    Provide the SN610 ATTCON with the busy 
    station number/name display when reentering 
    a Camped-On trunk.(1) 441
    (2) 0: To be provided
    1 : Not to be provided
    START
    END
    CM08
    CM41
    START
    END
    CM20
    START
    END
    CM08 
    						
    							ND-45670 (E) CHAPTER 2
    Page 41
    Revision 2.0
    ATTENDANT CONSOLE (SN610 ATTCON)
    PROGRAMMING
    DESCRIPTION DATA
    Assign the card number of the interface circuit 
    for the SN610 ATTCON to its associated 
    LEN. (1) 0000-0511 : LEN No.
    (2) E000-E007 : ATTCON No.
    Set the terminating system for the incoming 
    calls to SN610 ATTCON.• YY = 02 (Day mode), YY = 03 (Night 
    mode)
    (1) Trunk No. (000-255)
    (2) 14:  Termination to SN610 ATTCON
    Assign the required Attendant Call Selection 
    keys and ATTCON Function keys to each 
    SN610 ATTCON.
    If no data is set, the default setting is as 
    follows (Refer to MULTI-FUNCTION KEY 
    for assignment of Multi-Function Keys).• YY = 00
    (1) ATTCON No. (E000-E007) +   + Key 
    No. 
    (2) F6000-F6067: Type of Calls to be as-
    signed
    F6100-F6245: Functions to be assigned CM10
    CM30 START
    A
    CM90
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 2
    Revision 2.0
    ATTENDANT CONSOLE (SN610 ATTCON)
    DESCRIPTION DATA
    Note:
    ANS or RLS keys can be assigned on
    either 25 or 26 by CM60 YY = 15. 
    Allocate the ATT Group No. to each SN610 
    ATTCON.• YY = 00
    (1) ATTCON No. (0-7)
    (2) 0:  ATT GROUP 0
    3:  ATT GROUP 3
    Specify the Master SN610 ATTCON within 
    the ATT Group assigned by YY = 00. • YY = 01
    (1) ATTCON No. (0-7) 
    (2) 0/1 :  Master/Sub
    Specify the location of Answer (ANS) and 
    Release (RLS) key. • YY = 15
    (1) ATTCON No. (0-7)
    (2) 0 : Key No.25-Release, Key No.26-An-
    swer
    1 : Key No.25-Release, Key No.26-
    Answer
    Specify the tenants to be handled by each ATT 
    Group.•Y = 0-3
    (1) Tenant No. (00-63)
    (2) 0/1 :  To be handled/Not to be handled
    END
    A
    CM62
    CM60
    Key  No.DataDescription                  
    01 F6110 Mode (MODE)
    02 F6111 Programming (PROG) 
    07-12 F6240-F6245 Loop 1-Loop 6 
    16 F6061 Re-Call (RCL)
    17 F6060 Operator Call (ATND)
    18 F6000 C.O. Incoming 0 
    (LDN0)
    19 F6200 Source (SRC)
    20 F6201 Destination (DEST) 
    23 F6204 Hold (HOLD)
    24 F6202 Cancel (CANCEL) 
    25
    NoteAnswer (ANS) 
    26 
    Note Release (RLS)
    LOOP1LOOP2LOOP3LOOP4LOOP5LOOP6
    01
    AN S
    25RLS
    26
    123
    456
    78 9
    *0#SRC DEST
    H O LD C ANC EL MODE PROG
    13 1 4
    15 1 6
    17 1 819 20
    21 22
    23 24
    07
    0203040506
    08
    09101112
    AB C D E F
    JKL M NO GHI
    TUV WX Y PRS
    OPER
    ||
    INITIAL
    INITIAL 
    						
    							ND-45670 (E) CHAPTER 2
    Page 43
    Revision 2.0
    ATTENDANT CONSOLE (SN610): ATTENDANT CALLED/CALLING NAME DISPLAY
    PROGRAMMING 
    DESCRIPTION DATA
    Provide the system with the Name Display 
    Service. (1) 255 
    (2) 1 :  To be provided
    Assign the access code for station user name 
    entry, used from individual stations.• Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code (62) 
    (2) A10 
    Assign a Trunk Name Number to each Trunk 
    Route. • YY = 03
    (1) 00-63 : (Trunk Route No.) 
    (2) 00 : Trunk Name No. 00
    14 : Trunk Name No. 14 
    15  : Kind of Trunk Route assigned by 
    CM35 YY = 00 is displayed 
    16 : Trunk Name No. 16
    63 : Trunk Name No. 63
    Assign the desired station user name to each 
    station number by Y = 0 or Y = 1.• Y = 0 (By Character Code)
    (1) X-XXXX:  Station No. 
    (2) Character Code
    (20-7F: See Character Code Table) Max. 
    16 digits
    • Y = 1 (By Character) 
    (1) X-XXXX:  Station No. 
    (2) Character (A-Z, 0-9)
    Max. 8 characters 
    Assign the desired trunk name to each trunk 
    route by Y = 2 or Y = 3.• Y = 2 (By Character Code)
    (1) 00-14, 16-63 (Trunk Name No. assigned 
    by CM35 YY = 03.)
    (2) Character Code
    (20-7F: See Character Code Table) 
    Max. 8 digits
    • Y = 3 (By Character) 
    (1) 00-14, 16-63 (Trunk Name No. assigned 
    by CM35 YY = 03.)
    (2) Character Code (A-Z, 0-9) 
    Max. 4 characters
    START
    END
    CM20
    CM35
    CM77
    CM08
    CM77
    ||
    || 
    						
    All NEC manuals Comments (0)