CHAPTER 2 ND-45670 (E) Pag e 4 22 Revision 2.0 UNIFORM NUMBERING-VOICE & DATA DESCRIPTION DATA To delete the designated digit of an area code: • YYY = 500-755 (1) 153 (Designation of digit to be deleted) (2) 00: No digits deleted 01: First digit deleted 10: First 10 digits deleted CCC: No digits deleted Assign the digits to be added when adding digits to those sent to a distant office. • YYY = 500-755 (1) 100 (Designation of digit Addition Pat- tern No.) (2) 00-49 (Digit Addition Pattern No. 00-49) CCC: No digits added • YYY = 900-949 (Digit Addition Pattern No. 00-49) (1) 0 (2) X-X...X [Digits to be added (Max. 32 digits)] X = 0-9, A (*), B (#), C (Fixed Pause) Assign the digit to be added to the required trunk routes when adding digits to those re- ceived from a distant office. • YY = 17 (1) 00-63 (Trunk Route No.) (2) 00: Add 0 01: Add 1 02: Add 2 03: Add 3 04: Add 4 05: Add 5 06: Add 6 07: Add 7 08: Add 8 09: Add 9 10: Add 2 digits per CM50 Assign the data for digit deletion to re- quired trunk routes for deleting the first one or two digits received from a distant office.• YY = 17 (1) 00-63 (Trunk Route No.) (2) 11: Delete first digit 12: Delete first two digits If two digit addition is required, assign the digits to be added (See CM35 YY=17, 2nd data = 10). • YY = 00 (1) 0 (2) XX (Digits to be added) A CM35 CM8A END CM50||
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 423 Revision 2.0 UNIFORM NUMBERING-VOICE & DATA Example 1: When the PBX is an end office in a network employing a Closed Numbering System. Programming for Example 1: COMMAND CODE 1ST DATA 2ND DATA REMARKS 20 Y = 0 20 Y = 0 8A YYY = A007 8 0A29 A29 5Assignment of Access Code (7, 8) to LCR Group 3. Assignment of Area Code Development Pattern No. 5. 8A YYY = 405 8A YYY = 405 8A YYY = 405 8A YYY = 405 72 73 8 715000 000 000 804Assignment of Route Pattern No. 00 to Area Code (72, 73, & 74). Assignment of the 4-digit Intra-Office Station to the Area Code 715. 8A YYY = 000 1 00000 Assignment of the order of LCR selec- tion (1st) for Route Pattern No. assigned by YYY = 405. 73XX OFFICE B OFFICE C OFFICE A 72XX 714X 72XX/73XX/ 8XXX 8XXX Trunk Route to Office A: Area Code of Office A: Area Code of Office B: Area Code of Office C: Area Code of Intra-Office Station: Numbering Plan Group: PBX 715X 00 72 73 8 715 0
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 24 Revision 2.0 UNIFORM NUMBERING-VOICE & DATA Example 2: When the PBX is a Tandem Office in the network. Programming for Example 2: COMMAND CODE 1ST DATA 2ND DATA REMARKS 20 Y= 0 7 A29 Assignment of Access Code 7 of LCR Group 3. 8A YYY= A00 3 5 Assignment of Area Code Development Pattern No. 5. 8A YYY= 405 740 001 Assignment of Route Pattern No. 01 to Area Code 740 of Office B. 8A YYY= 405 735 804 Assignment of the 4-digit Intra-Office Station to the Area Code 735. 8A YYY= 000 1 00001 Assignment of the order of LCR selec- tion (1st) for Route Pattern No. assigned by YYY = 405. OFFICE BOFFICE A Trunk Route to Office B: Area Code of Office B: Area Code of Intra-Office Station: Numbering Plan Group: PBX DIAL NO. 7400/7350 TRUNK ROUTE 017350 7350 7400 7400/7350 7400 01 740 735 0
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 425 Revision 2.0 VARIABLE TIMING PARAMETERS PROGRAMMING DESCRIPTION DATA Specify the required Timing Parameters ac- cording to the user’s requirements. If no data is set (Displayed “NONE”) the Standard tim- ing which is initially set is applied.•Y = 0-2 (1) XX (2) XX START CM41 END See the Command Manual.
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Page 425-1 Addendum-001 Revision 2.1 JULY, 1998 VOICE GUIDE (1900 Series Enhancement) PROGRAMMING To provide the message that is sent when a station goes off hook while Message Waiting/Call Forwarding-All Calls/ No No Disturb service is set to the station: DESCRIPTION DATA Specify the Multi-Connection of the Dig- ital Announcement Trunk (PN-2DATA) on Announcement Service. (1) 124 (2) 0/1 : Available/Not Available (Sin- gle Connection) Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note: The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot.(1) LEN (0000-0511) (2) EB000-EB127: Digital Announcement Trunk Circuit No. For PIM0/1: EB000-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 Assign the Class of Service for An- nouncement Service to the required sta- tions. • CM12 YY = 02 (1) X-XXXX: Primary Extension No. (2) XX XX *a: Service Restriction Class (A): 00- 15 • CM15 YY = 34 (Group 0) • CM15 YY = 35 (Group 1) • CM15 YY = 36 (Group 2) • CM15 YY = 37 (Group 3) • CM15 YY = 38 (Group 4) • CM15 YY = 39 [Recording for An- nouncement Service (Group 0-4)] (1) 00-15 : Service Restriction Class (A) assigned by CM12 YY = 02 (2) 1 : Allowed Assign access codes for Announcement Service. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) A03: Recording message (Group 0-4) A04: Replaying message (Group 0) A05: Replaying message (Group 1) A06: Replaying message (Group 2) A07: Replaying message (Group 3) A08: Replaying message (Group 4) A09: Deleting message (Group 0-4) CM08 CM10 START A CM20 CM12 CM15*a
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Addendum-001 Page 425-2 JULY, 1998 Revision 2.1 VOICE GUIDE (1900 Series Enhancement) Note 1:While both Message Waiting and Call Forwarding-All Calls/Do Not Disturb Service are set to the station, the message assigned by CM49 YY=13 1st data 00 is sent. Note 2:While Message Reminder (from STA/ATT) Service is set to the station, the message assigned by CM49 YY=13 1st data 00 is sent. Note 3:While Split Call Forwarding-All Calls Service is set to the station, the message assigned by CM49 YY=13 1st data 03 is sent. DESCRIPTION DATA Specify the dial tone, which is sent when a sta- tion goes off hook while the service is set for the station, as Special Dial Tone.•Y=2 (1) 12 (Dial Tone on Setting Message Wait- ing) 13 (Dial Tone on Setting Call Forward- ing-All Calls) 14 (Dial Tone on Setting Do Not Dis- turb) (2) 0: Special Dial Tone Validate the data set by CM48 Y=2 first data 12, 13, 14.• YYY=116 (1) 00-15: Service Restriction Class A (2) 1 : Valid Assign the function for each Digital An- nouncement Trunk Circuit.• YY=00 (1) 000-127: Digital Announcement Trunk Circuit No. assigned by CM10 (EB000-EB127) (2) 17XX : Voice Guide Message No. used for this feature (00-63) Assign the Message sent when the station goes off hook.• YY=13 (1) 00 (Message sent when Message Waiting is set) 03 (Message sent when Call Forwarding- All Calls/Do Not Disturb is set) (2) Message No. (00-63) END CM49 CM48 CM15 A
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Page 425-3 Addendum-001 Revision 2.1 JULY, 1998 VOICE GUIDE (1900 Series Enhancement) To provide the Message which is sent when the service feature setting to the station is completed or cancelled: HARDWARE REQUIRED Digital Announcement Trunk (PN-2DATA) DESCRIPTION DATA Assign the function for each Digital An- nouncement Trunk Circuit.• YY=00 (1) 000-127: Digital Announcement Trunk Circuit No. assigned by CM10 (EB000-EB127) (2) 17XX : Voice Guide Message No. used for this feature (00-63) Assign the Message No. when service setting is completed or cancelled to station.• YY=13 (1) 01 (Message sent when service is set) 02 (Message sent when service is can- celled) (2) Message No. (00-63) Message Replay Timer for Announcement Service.•Y=0 (1) 53 (2) 01-99 (4 sec.-396 sec.) If no data is set, the default setting is 60-64 sec. START END CM49 CM41
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Addendum-001 Page 425-4 JULY, 1998 Revision 2.1 This page is for your notes.
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 26 Revision 2.0 VOICE MAIL INTEGRATION (IN BAND) PROGRAMMING In addition to the programming of CALL FORWARDING-ALL CALLS/BUSY LINE/NO ANSWER, do the fol- lowing programming. DESCRIPTION DATA Specify whether Ringing Transfer to an At- tendant via VMS is available.(1) 063 (2) 0/1 : Available/Not Available Specify the sending of the Mail Box No. to the VMS when the VMS is recalled after transfer- ring a call to an unanswered station.(1) 333 (2) 0: To be sent 1 : Not to be sent Provide Message Waiting service for a station with MW lamp. • YY = 03 (1) X-XXXX: (Station No.) (2) 0: To be provided Provide VMS service for a station port inter- faced with the VMS (VMS station).• YY = 10 (1) X-XXXX: (Station No.) (2) 0: To be provided Provide Message Waiting service for a VMS station port.• YY = 13 (1) X-XXXX: (Station No.) (2) 0: To be provided Assign the Class of Service for Message Wait- ing to a station with a MW lamp and a VMS station port.• CM12 YY = 02 (1) X-XXXX: (Station No.) (2) XX XX *a *a: Service Restriction Class (A) (00-15 ) • CM15 YY = 24 (Station with MW lamp) YY = 40 (VMS Station) (1) XX: Service Restriction Class (A) as- signed by CM12 YY = 02 (2) 1 : Allowed Assign the access code for MW lamp set/can- cel from a VMS station port.• YY = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access code (2) 040: Set 041: Cancel Assign the access code to retrieve a message from the VMS and search Message Reminder/ Message Waiting.• YY = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access code (2) A46: Search A47: Retrieve START CM08 CM13 CM12 CM15 A
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Addendum-002 Page 427 JANUARY, 1999 Revision 2.2 VOICE MAIL INTEGRATION (IN BAND) DESCRIPTION DATA Assign the access code to be sent out to a VMS after/before a Mail Box Number, if re- quired. Note 1:“C” or “D” should not be assigned as the first digit of an access code, to insert prepause timing. Prepause timing is assigned by CM41 Y = 0, Function No. 44. Note 2:If “C” is inserted in the access code, it can be used as a pause (1.5 sec.). To provide a programmable pause, insert “D” instead of “C” (Pro- grammable Pause:CM41 Y = 0, Function No. 38).• YY = 00 (1) 3: Access Code to be sent out before a Mail Box No. Note 1 4: Access Code to be sent out after a Mail Box No. (2) X: Access code to be sent out to a VMS XXXX: X: 0-9, A (*), B (#), C/ D (Pause) Note 2 NONE : Available/Not Available Specify the prepause timing, DTMF Signal Width, and Inter-digital Pause for VMS.•Y = 0 (1) 44 (Prepause Timing) (2) 00-12, 13: 0-12 sec. in 1 sec increments, 0.5 sec. If no data is set, the default setting is 1 second. Specify the DTMF signal width for VMS. • Y = 0 (1) 48 (2) 00/01: 64 msec/128 msec If no data is set, default setting is 128 msec. Specify the DTMF inter-digital pause for VMS.•Y = 0 (1) 49 (2) 00: 32 msec. 04: 128 msec 01: 64 msec. 05: 160 msec. 02: 80 msec. 06: 192 msec. 03: 96 msec. 07: 240 msec. If no data is set, default setting is 160 msec. Assign VMS display, if required. • Y = 0 (By Character Code) (1) X-XXXX: Station No. (2) 564D53 (VMS character code) • Y = 1 (By Character) (1) X-XXXX: Station No. (2) VMS (Character) CM50 CM77 CM41 B A