    DESCRIPTION DATA
    To delete the designated digit of an area code:  • YYY = 500-755
    (1) 153 (Designation of digit to be deleted) 
    (2) 00: No digits deleted 
    01: First digit deleted 
    10: First 10 digits deleted 
    CCC: No digits deleted
    Assign the digits to be added when adding 
    digits to those sent to a distant office. • YYY = 500-755
    (1) 100 (Designation of digit Addition Pat-
    tern No.)
    (2) 00-49 (Digit Addition Pattern No. 00-49)
    CCC: No digits added 
    • YYY = 900-949 (Digit Addition Pattern 
    No. 00-49) 
    (1) 0 
    (2) X-X...X [Digits to be added (Max. 32 
    digits)] 
    X = 0-9, A (*), B (#), C (Fixed Pause) 
    Assign the digit to be added to the required 
    trunk routes when adding digits to those re-
    ceived from a distant office. • YY = 17
    (1) 00-63 (Trunk Route No.)
    (2) 00: Add 0
    01: Add 1
    02: Add 2
    03: Add 3
    04: Add 4
    05: Add 5
    06: Add 6
    07: Add 7
    08: Add 8
    09: Add 9
    10: Add 2 digits per CM50
    Assign the data for digit deletion to re-
    quired trunk routes for deleting the first
    one or two digits received from a distant
    office.• YY = 17 
    (1) 00-63 (Trunk Route No.) 
    (2) 11: Delete first digit 
    12: Delete first two digits
    If two digit addition is required, assign the
    digits to be added (See CM35 YY=17,
    2nd data = 10). • YY = 00
    (1) 0 
    (2) XX (Digits to be added) 
    A
    CM35
    CM8A
    END
    CM50|| 
    						
    							ND-45670 (E) CHAPTER 2
    Page 423
    Revision 2.0
    UNIFORM NUMBERING-VOICE & DATA
    Example 1:
     When the PBX is an end office in a network employing a Closed Numbering System. 
    Programming for Example 1:
    COMMAND CODE 1ST DATA 2ND DATA REMARKS
    20 Y = 0
    20 Y = 0
    8A YYY = A007
    8
    0A29
    A29
    5Assignment of Access Code (7, 8) to
    LCR Group 3.
    Assignment of Area Code Development
    Pattern No. 5. 
    8A YYY = 405 
    8A YYY = 405 
    8A YYY = 405 
    8A YYY = 405 72
    73
    8
    715000
    000
    000
    804Assignment of Route Pattern No. 00 to
    Area Code (72, 73, & 74).
    Assignment of the 4-digit Intra-Office
    Station to the Area Code 715. 
    8A YYY = 000 1 00000 Assignment of the order of LCR selec-
    tion (1st) for Route Pattern No. assigned
    by YYY = 405. 
    73XX
    OFFICE
    B
    OFFICE
    C OFFICE
    A 72XX
    714X
    72XX/73XX/
    8XXX
    8XXX
    Trunk Route to Office A:                  
    Area Code of Office A:                     
    Area Code of Office B:                     
    Area Code of Office C:                       
    Area Code of Intra-Office Station:   
    Numbering Plan Group:                      
    PBX
    715X
    00
    72
    73
    8
    715
    0 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 24
    Revision 2.0
    UNIFORM NUMBERING-VOICE & DATA
    Example 2:
     When the PBX is a Tandem Office in the network.
    Programming for Example 2:
    COMMAND CODE 1ST DATA 2ND DATA REMARKS
    20 Y= 0 7 A29 Assignment of Access Code 7 of LCR
    Group 3. 
    8A YYY= A00 3 5 Assignment  of  Area Code Development
    Pattern No. 5. 
    8A YYY= 405 740 001 Assignment of Route Pattern No. 01 to
    Area Code 740 of Office B. 
    8A YYY= 405 735 804 Assignment  of  the  4-digit  Intra-Office
    Station to the Area Code 735. 
    8A YYY= 000 1 00001 Assignment of the order of LCR selec-
    tion (1st) for Route Pattern No. assigned
    by YYY = 405. 
    OFFICE
    BOFFICE
    A
    Trunk Route to Office B:        
    Area Code of Office B:           
    Area Code of Intra-Office Station:  
    Numbering Plan Group:             
    PBX
    DIAL NO.
    7400/7350
    TRUNK ROUTE 017350
    7350
    7400 7400/7350
    7400
    01
    740
    735
    0 
    						
    							ND-45670 (E) CHAPTER 2
    Page 425
    Revision 2.0
    VARIABLE TIMING PARAMETERS
    PROGRAMMING
    DESCRIPTION DATA
    Specify the required Timing Parameters ac-
    cording to the user’s requirements. If no data 
    is set (Displayed “NONE”) the Standard tim-
    ing which is initially set is applied.•Y = 0-2
    (1) XX  
    (2) XX 
    START
    CM41
    END
    See the Command Manual. 
    						
    							CHAPTER 2 ND-45670 (E)
    Page 425-1 Addendum-001
    Revision 2.1 JULY, 1998
    VOICE GUIDE (1900 Series Enhancement)
    PROGRAMMING
    To provide the message that is sent when a station goes off hook while Message Waiting/Call Forwarding-All Calls/
    No No Disturb service is set to the station:
    DESCRIPTION DATA
    Specify the Multi-Connection of the Dig-
    ital Announcement Trunk (PN-2DATA)
    on Announcement Service. (1) 124 
    (2) 0/1 : Available/Not Available (Sin-
    gle Connection)
    Assign a Digital Announcement Trunk
    Circuit No. to the required LEN.
    Note:
       The Digital Announcement Trunk 
    Circuit No. must be assigned to the 
    first LEN (Level 0) and/or the third 
    LEN (Level 2) of each LT slot.(1) LEN (0000-0511) 
    (2) EB000-EB127: Digital Announcement 
    Trunk Circuit No. 
    For PIM0/1: EB000-EB031 
    For PIM2/3: EB032-EB063 
    For PIM4/5: EB064-EB095 
    For PIM6/7: EB096-EB127 
    Assign the Class of Service for An-
    nouncement Service to the required sta-
    tions. •  CM12 YY = 02
    (1)  X-XXXX:  Primary Extension No.
    (2) XX
     XX 
    *a: Service Restriction Class (A):  00-
    15
    •  CM15 YY = 34 (Group 0) 
    •  CM15 YY = 35 (Group 1) 
    •  CM15 YY = 36 (Group 2) 
    •  CM15 YY = 37 (Group 3) 
    •  CM15 YY = 38 (Group 4) 
    •  CM15 YY = 39 [Recording for An-
    nouncement Service (Group 0-4)] 
    (1)  00-15 : Service Restriction Class (A) 
    assigned by CM12 YY = 02 
    (2) 1 : Allowed 
    Assign access codes for Announcement
    Service. •  Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code 
    (2)  A03:  Recording message (Group 0-4) 
    A04:  Replaying message (Group 0)
    A05:  Replaying message (Group 1)
    A06:  Replaying message (Group 2) 
    A07:  Replaying message (Group 3)
    A08:  Replaying message (Group 4)
    A09:  Deleting message (Group 0-4) 
    CM08
    CM10 START
    A
    CM20
    CM12
    CM15*a 
    						
    							ND-45670 (E) CHAPTER 2
    Addendum-001 Page 425-2
    JULY, 1998 Revision 2.1
    VOICE GUIDE (1900 Series Enhancement)
    Note 1:While both Message Waiting and Call Forwarding-All Calls/Do Not Disturb Service are set to the station,
    the message assigned by CM49 YY=13 1st data 00 is sent.
    Note 2:While Message Reminder (from STA/ATT) Service is set to the station, the message assigned by CM49
    YY=13 1st data 00 is sent.
    Note 3:While Split Call Forwarding-All Calls Service is set to the station, the message assigned by CM49 YY=13
    1st data 03 is sent.
    DESCRIPTION DATA
    Specify the dial tone, which is sent when a sta-
    tion goes off hook while the service is set for
    the station, as Special Dial Tone.•Y=2
    (1) 12 (Dial Tone on Setting Message Wait-
    ing)
    13 (Dial Tone on Setting Call Forward-
    ing-All Calls)
    14 (Dial Tone on Setting Do Not Dis-
    turb)
    (2) 0: Special Dial Tone
    Validate the data set by CM48 Y=2 first data
    12, 13, 14.• YYY=116
    (1) 00-15: Service Restriction Class A
    (2) 1 : Valid
    Assign the function for each Digital An-
    nouncement Trunk Circuit.• YY=00
    (1) 000-127: Digital Announcement Trunk 
    Circuit No. assigned by CM10 
    (EB000-EB127)
    (2) 17XX
    : Voice Guide
    Message No. used for this feature 
    (00-63)
    Assign the Message sent when the station
    goes off hook.• YY=13
    (1) 00 (Message sent when Message Waiting 
    is set)
    03 (Message sent when Call Forwarding-
    All Calls/Do Not Disturb is set)
    (2) Message No. (00-63)
    END
    CM49
    CM48
    CM15
    A 
    						
    							CHAPTER 2 ND-45670 (E)
    Page 425-3 Addendum-001
    Revision 2.1 JULY, 1998
    VOICE GUIDE (1900 Series Enhancement)
    To provide the Message which is sent when the service feature setting to the station is completed or cancelled:
    HARDWARE REQUIRED
    Digital Announcement Trunk (PN-2DATA)
    DESCRIPTION DATA
    Assign the function for each Digital An-
    nouncement Trunk Circuit.• YY=00
    (1) 000-127: Digital Announcement Trunk 
    Circuit No. assigned by CM10 
    (EB000-EB127)
    (2) 17XX
    : Voice Guide
    Message No. used for this feature 
    (00-63)
    Assign the Message No. when service setting
    is completed or cancelled to station.• YY=13
    (1) 01 (Message sent when service is set)
    02 (Message sent when service is can-
    celled)
    (2) Message No. (00-63)
    Message Replay Timer for Announcement
    Service.•Y=0
    (1) 53
    (2) 01-99 (4 sec.-396 sec.)
    If no data is set, the default setting is 60-64
    sec.
    START
    END
    CM49
    CM41 
    						
    							ND-45670 (E) CHAPTER 2
    Addendum-001 Page 425-4
    JULY, 1998 Revision 2.1
    This page is for your notes. 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 26
    Revision 2.0
    VOICE MAIL INTEGRATION (IN BAND)
    PROGRAMMING 
    In addition to the programming of CALL FORWARDING-ALL CALLS/BUSY LINE/NO ANSWER, do the fol-
    lowing programming.
    DESCRIPTION DATA
    Specify whether Ringing Transfer to an At-
    tendant via VMS is available.(1) 063
    (2) 0/1 : Available/Not Available
    Specify the sending of the Mail Box No. to the 
    VMS when the VMS is recalled after transfer-
    ring a call to an unanswered station.(1) 333
    (2) 0: To be sent
    1 : Not to be sent
    Provide Message Waiting service for a station 
    with MW lamp. • YY = 03
    (1) X-XXXX: (Station No.)
    (2) 0: To be provided
    Provide VMS service for a station port inter-
    faced with the VMS (VMS station).• YY = 10
    (1) X-XXXX: (Station No.)
    (2) 0: To be provided
    Provide Message Waiting service for a VMS 
    station port.• YY = 13
    (1) X-XXXX: (Station No.)
    (2) 0: To be provided
    Assign the Class of Service for Message Wait-
    ing to a station with a MW lamp and a VMS 
    station port.• CM12 YY = 02
    (1) X-XXXX: (Station No.)
    (2) XX
    XX
     *a
    *a: Service Restriction Class (A)
    (00-15 )
    • CM15
    YY = 24 (Station with MW lamp)
    YY = 40 (VMS Station)
    (1) XX: Service Restriction Class (A) as-
    signed by CM12 YY = 02 
    (2) 1 : Allowed
    Assign the access code for MW lamp set/can-
    cel from a VMS station port.• YY = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access code
    (2) 040: Set
    041: Cancel
    Assign the access code to retrieve a message 
    from the VMS and search Message Reminder/
    Message Waiting.• YY = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access code
    (2) A46: Search
    A47: Retrieve
    START
    CM08
    CM13
    CM12
    CM15
    A 
    						
    							ND-45670 (E) CHAPTER 2
    Addendum-002 Page 427
    JANUARY, 1999 Revision 2.2
    VOICE MAIL INTEGRATION (IN BAND)
    DESCRIPTION DATA
    Assign the access code to be sent out to a 
    VMS after/before a Mail Box Number, if re-
    quired.
    Note 1:“C” or “D” should not be assigned
    as the first digit of an access code, to
    insert prepause timing. Prepause
    timing is assigned by CM41 Y = 0,
    Function No. 44. 
    Note 2:If “C” is inserted in the access code,
    it can be used as a pause (1.5 sec.).
    To provide a programmable pause,
    insert “D” instead of “C” (Pro-
    grammable Pause:CM41 Y = 0,
    Function No. 38).• YY = 00
    (1) 3: Access Code to be sent out before a 
    Mail Box No. Note 1 
    4: Access Code to be sent out after a 
    Mail Box No. 
    (2) X: Access code to be sent out to 
    a VMS
    XXXX: X: 0-9, A (*), B (#), C/
    D (Pause) Note 2
    NONE : Available/Not Available
    Specify the prepause timing, DTMF Signal 
    Width, and Inter-digital Pause for VMS.•Y = 0
    (1) 44 (Prepause Timing)
    (2) 00-12, 13: 0-12 sec. in 1 sec increments, 
    0.5 sec.
    If no data is set, the default setting is 1 second.
    Specify the DTMF signal width for VMS. • Y = 0
    (1) 48
    (2) 00/01: 64 msec/128 msec
    If no data is set, default setting is 128 msec.
    Specify the DTMF inter-digital pause for 
    VMS.•Y = 0
    (1) 49
    (2) 00: 32 msec. 04: 128 msec
    01: 64 msec. 05: 160 msec.
    02: 80 msec. 06: 192 msec.
    03: 96 msec. 07: 240 msec.
    If no data is set, default setting is 160 msec.
    Assign VMS display, if required. • Y = 0 (By Character Code)
    (1) X-XXXX: Station No.
    (2) 564D53 (VMS character code)
    • Y = 1 (By Character)
    (1) X-XXXX: Station No.
    (2) VMS (Character)
    CM50