CHAPTER 2 ND-45670 (E) Pag e 2 4 Revision 2.0 ALPHANUMERIC DISPLAY PROGRAMMING DESCRIPTION DATA Provide the system with the Name Display Service. (1) 255 (2) 1 : To be provided Station number and number display provided when an incoming call terminates to a Prime Line and a Primary Extension.(1) 335 (2) 1 : To be provided Assign the access code for station user name entry (used from individual stations).• Y= 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (62) (2) A10 Assign a Trunk Name Number to each Trunk Route.• YY = 03 (1) 00-63 : Trunk Route No. (2) 00 : Trunk Name No. 00 14 : Trunk Name No. 14 15 : Kind of Trunk Route assigned by CM35 YY = 00 is displayed 16 : Trunk Name No.16 63 : Trunk Name No. 63 Assign the desired station user’s name to each station number by Y = 0 or Y = 1.• Y = 0 (By Character Code) (1) X-XXXX: Station No. (2) Character Code (20-7F:See Character Code Table Max. 16 digits) • Y = 1 (By Character) (1) X-XXXX: Station No. (2) Character (A-Z, 0-9) Max. 8 charactersCM08 CM20 START A CM35 CM77
ND-45670 (E) CHAPTER 2 Page 25 Revision 2.0 ALPHANUMERIC DISPLAY Note 1:The maximum number of stations that can be provided with the user’s name display is 384. The maximum number of characters per name is eight, including spaces. The Maintenance Administration Terminal (MAT) or Customer Administration Terminal (CAT) can be used to register or change a name. A Multiline Terminal can register or change the name assignment of that individual Multiline Terminal. Note 2:User names can be assigned to stations that do not have an LCD. Note 3:The trunk name display is provided on a trunk-route basis. The maximum amount of characters in the trunk name display is four. The maximum number of trunk routes assignable is 16. The MAT or CAT can be used to register or change a trunk name display. Note 4:There are two ways to change a name that is currently programmed. (1) by overwriting with a new name, or (2) by inserting a blank space as the first character to cancel the existing name. DESCRIPTION DATA Assign the desired trunk name to each trunk route by Y = 2 or Y = 3.• Y = 2 (By Character Code) (1) 00-14, 16-63:Trunk Name No. assigned by CM35 YY = 03. (2) Character Code 20-7F: See Character Code Table Max. 8 digits • Y = 3 (By Character) (1) 00-14, 16-63: Trunk Name No. assigned by CM35 YY = 03. (2) Character Code (A-Z, 0-9) Max. 4 char- acters END CM77 A
CHAPTER 2 ND-45670 (E) Pag e 2 6 Revision 2.0 ALPHANUMERIC DISPLAY Character Code Table 234567 0 0@P \ p 1!1AQaq 2”2BRb r 3#3CSc s 4$4DTd t 5%5 EU e u 6&6 FV f v 7’7GWgw 8(8HXhx 9)9IYiy A*: JZjz B+;K[k{ C,N^n® F/?O_o¬ 1ST 2ND
ND-45670 (E) CHAPTER 2 Page 27 Revision 2.0 ANALOG PORT ADAPTER (1200 Series Enhancement) PROGRAMMING To assign the Single Port Mode: To assign the Dual Port Mode: 1. Data Assignment for Multiline Terminal accommodates the Analog Port Adapter. DESCRIPTION DATA Provide the Analog Port Adapter to the required stations.• YY=32 (1) X-XXXX: Primary Extension No. (2) 0: To be provided Assign the Single Port Mode to the required stations.• YY=33 (1) X-XXXX: Primary Extension No. (2) 1 : Single Port Mode Specify whether a ringing signal is sent to the Analog terminal.• YY=35 (1) X-XXXX: Primary Extension No. (2) 0/1 : Not to be sent/To be sent DESCRIPTION DATA Provide the Analog Port Adapter to the required stations.• YY=32 (1) X-XXXX: Primary Extension No. (2) 0: To be provided Assign the Dual Port Mode to the required stations.• YY=33 (1) X-XXXX: Primary Extension No. (2) 0: Dual Port Mode START CM13 END START CM13 END INITIAL
CHAPTER 2 ND-45670 (E) Pag e 2 8 Revision 2.0 ANALOG PORT ADAPTER (1200 Series Enhancement) 2. Data Assignment for Analog Terminal connected to the Analog Port Adapter. . DESCRIPTION DATA Assign an Analog Terminal Station No. to the required LEN.(1) LEN (0000-0511) (2) FX-FXXXX: Analog Terminal Station No. Note:The Analog Terminal Station No. must be assigned to the LEN of right side LT slot to the LT slot for DLC. Example: When the DLC card is mounted in the LT01 slot and LT03 slot. Assignment Example: CM 10 - LEN 0000 = F 200 for D term Primary Extension LEN 0004 = F 300 for Analog Terminal If level 0 of the LEN is used for the D term, the adjacent level 0 must be used. START A CM10 LT00 LT01LT02 LT03LT04 D L CD L C LT slot for assigning an Analog Terminal Station No. (The DLC card is not mounted in this slot.)
ND-45670 (E) CHAPTER 2 Page 29 Revision 2.0 ANALOG PORT ADAPTER (1200 Series Enhancement) DESCRIPTION DATA Assign a key for Analog Terminal. • YY=00 (1) Analog Terminal Station No. + + Key No. (2) X-XXXX: Analog Terminal Station No. assigned by CM10. Assign an Analog Terminal Station No. as Prime Line.(1) X-XXXX: Analog Terminal Station No. (2) X-XXXX: Analog Terminal Station No. Provide the Analog Port Adapter to the required station.• YY=34 (1) X-XXXX: Analog Terminal Station No. (2) 0: To be provided Specify whether a ringing signal is sent to the Analog Terminal.• YY=35 (1) X-XXXX: Primary Extension No. (2) 0/1 : Not to be sent/To be sent Specify the PAD control of the Analog Terminal.• YY=09 (1) X-XXXX: Analog Terminal Station No. (2) 0/1 : Not Available/AvailableCM90 CM93 CM13 END A ,
CHAPTER 2 ND-45670 (E) Pag e 3 0 Revision 2.0 ANNOUNCEMENT SERVICE PROGRAMMING DESCRIPTION DATA Specify the Multi-Connection of the Digital Announcement Trunk (PN-2DATA) on Announcement Service. (1) 124 (2) 0/1 : Available/Not Available (Single Connection) Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot.(1) LEN (0000-0511) (2) EB000-EB127: Digital Announcement Trunk Circuit No. For PIM0/1: EB000-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 • CM12 YY = 02 (1) X-XXXX: Primary Extension No. (2) XX XX *a: Service Restriction Class (A): 00-15 • CM15 YY = 34 (Group 0) • CM15 YY = 35 (Group 1) • CM15 YY = 36 (Group 2) • CM15 YY = 37 (Group 3) • CM15 YY = 38 (Group 4) • CM15 YY = 39 [Recording for An- nouncement Service (Group 0-4)] (1) 00-15 : Service Restriction Class (A) assigned by CM12 YY = 02 (2) 1 : Allowed Assign access codes for Announcement Service. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) A03: Recording message (Group 0-4) A04: Replaying message (Group 0) A05: Replaying message (Group 1) A06: Replaying message (Group 2) A07: Replaying message (Group 3) A08: Replaying message (Group 4) A09: Deleting message (Group 0-4) CM08 CM10 START A CM20 CM12 CM15*a
ND-45670 (E) CHAPTER 2 Page 31 Revision 2.0 ANNOUNCEMENT SERVICE Note 1:A maximum of five different announcements can be accessed. There is a limit of 10 Digital Announcement Trunk Circuit for each of the five different announcements. When recording an announcement, each Digital Announcement Trunk Circuit must be recorded individually. Note 2:Each time a station is connected to a Digital Announcement Trunk Circuit, the message will be repeated three times. The station will then be disconnected. Note 3:For the single connection of a Digital Announcement Trunk Circuit, the duration of an announcement is limited to 60 seconds. Note 4:For the multi-connection of a Digital Announcement Trunk Circuit, the duration of replay for an announce- ment is programmable from 4 to 396 seconds. DESCRIPTION DATA When multi-connection is provided (CM08124 = 0), specify the duration of message replay for Announcement Service.•Y = 0 (1) 53 (2) 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 60-64 seconds. Assign the function for each Digital Announcement Trunk.• YY = 00 (1) 000-127: Digital Announcement Trunk Circuit No. assigned by CM10 (EB000-EB127) (2) 04X X *a: Group No. (0-4) *b: Message No. (0-9) To provide a Tie Line party with this service, assign the Announcement Service Group 0-4 to the required Trunk Routes.• YY = 69 (Group 0) • YY = 70 (Group 1) • YY = 71 (Group 2) • YY = 72 (Group 3) • YY = 73 (Group 4) (1) 00-63 : Trunk Route No. (2) 1 : Allowed END CM41 A CM49 CM35*b *a
CHAPTER 2 ND-45670 (E) Pag e 3 2 Revision 2.0 ANNOUNCEMENT SERVICE To provide a voice message when an incoming C.O. line/Tie line call has been transferred and encounters a busy or no answer condition: DESCRIPTION DATA Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot.(1) LEN (0000-0511) (2) EB000-EB127: Digital Announcement Trunk Circuit No. For PIM0/1: EB000-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 Assign the feature for a voice message connection to a transferred trunk when the transferred destination does not answer or the transferred destination is busy to the required tenant. • YY = 50 (No Answer) (1) 00-63: Tenant No. (2) 0 • YY = 51 (Busy) (1) 00-63: Tenant No. (2) 0 Assign the function for each Digital Announcement Trunk.• YY = 00 (1) 000-127: Digital Announcement Trunk Circuit No. assigned by CM10 (EB000-EB127) (2) 06XX : No Answer *a: Message No. (00-63) 07XX : Busy *a: Message No. (00-63) • YY = 06 (No Answer) • YY = 07 (Busy) (1) 00-63: Tenant No. of transferring station (2) 00-63: Message No. assigned by YY = 00 To record, replay, or delete a message, assign the respective Digital Announcement Trunk access code. • Y = 0-3 (Number Plan Group 0-3) (1) X-XXX: Access Code (2) A00: Record A01: Replay A02: Delete CM10 START END CM65 CM49 CM20 *a *a
ND-45670 (E) CHAPTER 2 Page 33 Revision 2.0 ANNOUNCEMENT SERVICE Note 5:Announcement Service can be used to provide a voice message when an incoming C.O. line/Tie line call has been transferred and encounters a busy or no answer condition. After the voice message is given, nor- mal call processing continues. -This application can be programmed on a tenant basis. - Only one (1) message of up to 60 seconds can be recorded on an individual Digital Announcement Trunk Circuit. - In this application, a minimum of two digital announcement Trunk Circuits are needed, one for busy condition, and one for no answer. - More than one Digital Announcement Trunk Circuit can be used, depending on traffic conditions. - System programming can be set to, wait until circuit(s) become free or immediately follow prepro- grammed normal call handling, if a busy condition is encountered. - Digital Announcement Trunk Circuits can be shared among tenants. - This feature does not function on Attendant transferred calls.