    							CHAPTER 2 ND-45670 (E)
    Pag e 2 4
    Revision 2.0
    ALPHANUMERIC DISPLAY
    PROGRAMMING
    DESCRIPTION DATA
    Provide the system with the Name Display 
    Service. (1) 255 
    (2) 1 :  To be provided
    Station number and number display provided 
    when an incoming call terminates to a Prime 
    Line and a Primary Extension.(1) 335 
    (2) 1 :  To be provided 
    Assign the access code for station user name 
    entry (used from individual stations).• Y= 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code (62)
    (2) A10 
    Assign a Trunk Name Number to each Trunk 
    Route.• YY = 03
    (1) 00-63 : Trunk Route No.
    (2) 00 : Trunk Name No. 00
    14 : Trunk Name No. 14
    15 : Kind of Trunk Route assigned 
    by CM35 YY = 00 is displayed 
    16 : Trunk Name No.16
    63 : Trunk Name No. 63
    Assign the desired station user’s name to each 
    station number by Y = 0 or Y = 1.• Y = 0 (By Character Code)
    (1) X-XXXX:  Station No. 
    (2) Character Code
    (20-7F:See Character Code Table Max. 
    16 digits)
    • Y = 1 (By Character) 
    (1) X-XXXX:  Station No. 
    (2) Character (A-Z, 0-9) Max. 8 charactersCM08
    CM20 START
    A
    CM35
    CM77 
    						
    							ND-45670 (E) CHAPTER 2
    Page 25
    Revision 2.0
    ALPHANUMERIC DISPLAY
    Note 1:The maximum number of stations that can be provided with the user’s name display is 384. The maximum
    number of characters per name is eight, including spaces. The Maintenance Administration Terminal
    (MAT) or Customer Administration Terminal (CAT) can be used to register or change a name. A Multiline
    Terminal can register or change the name assignment of that individual Multiline Terminal.
    Note 2:User names can be assigned to stations that do not have an LCD. 
    Note 3:The trunk name display is provided on a trunk-route basis. The maximum amount of characters in the trunk
    name display is four. The maximum number of trunk routes assignable is 16. The MAT or CAT can be used
    to register or change a trunk name display.
    Note 4:There are two ways to change a name that is currently programmed. (1) by overwriting with a new name,
    or (2) by inserting a blank space as the first character to cancel the existing name. 
    DESCRIPTION DATA
    Assign the desired trunk name to each trunk 
    route by Y = 2 or Y = 3.• Y = 2 (By Character Code)
    (1) 00-14, 16-63:Trunk Name No. assigned 
    by CM35 YY = 03. 
    (2) Character Code 
    20-7F: See Character Code Table  Max. 8 
    digits 
    • Y = 3 (By Character) 
    (1) 00-14,  16-63: Trunk Name No. assigned 
    by CM35 YY = 03. 
    (2) Character Code (A-Z, 0-9) Max. 4 char-
    acters 
    END
    CM77
    A 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 6
    Revision 2.0
    ALPHANUMERIC DISPLAY
    Character Code Table
    234567
    0
    0@P \ p
    1!1AQaq
    2”2BRb r
    3#3CSc s
    4$4DTd t
    5%5 EU e u
    6&6 FV f v
    7’7GWgw
    8(8HXhx
    9)9IYiy
    A*: JZjz
    B+;K[k{
    C,N^n®
    F/?O_o¬
    1ST
    2ND 
    						
    							ND-45670 (E) CHAPTER 2
    Page 27
    Revision 2.0
    ANALOG PORT ADAPTER (1200 Series Enhancement)
    PROGRAMMING
    To assign the Single Port Mode:
    To assign the Dual Port Mode:
    1. Data Assignment for Multiline Terminal accommodates the Analog Port Adapter.
    DESCRIPTION DATA
    Provide the Analog Port Adapter to the 
    required stations.• YY=32
    (1) X-XXXX: Primary Extension No.
    (2) 0: To be provided
    Assign the Single Port Mode to the required 
    stations.• YY=33
    (1) X-XXXX: Primary Extension No.
    (2) 1 : Single Port Mode
    Specify whether a ringing signal is sent to the 
    Analog terminal.• YY=35
    (1) X-XXXX: Primary Extension No.
    (2) 0/1 : Not to be sent/To be sent
    DESCRIPTION DATA
    Provide the Analog Port Adapter to the 
    required stations.• YY=32
    (1) X-XXXX: Primary Extension No.
    (2) 0: To be provided
    Assign the Dual Port Mode to the required 
    stations.• YY=33
    (1) X-XXXX: Primary Extension No.
    (2) 0: Dual Port Mode
    START
    CM13
    END
    START
    CM13
    END
    INITIAL 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 8
    Revision 2.0
    ANALOG PORT ADAPTER (1200 Series Enhancement)
    2. Data Assignment for Analog Terminal connected to the Analog Port Adapter.
    .
    DESCRIPTION DATA
    Assign an Analog Terminal Station No. to the 
    required LEN.(1) LEN (0000-0511)
    (2) FX-FXXXX: Analog Terminal Station 
    No.
    Note:The Analog Terminal Station No.
    must be assigned to the LEN of right
    side LT slot to the LT slot for DLC.
    Example: When the DLC card is
    mounted in the LT01 slot and LT03
    slot.
    Assignment Example:
    CM 10 - LEN 0000 = F 200 for D
    term Primary
    Extension
    LEN 0004 = F 300 for Analog 
    Terminal
    If level 0 of the LEN is used for the D
    term, 
    the adjacent level 0 must be used.
    START
    A
    CM10
    LT00 LT01LT02
    LT03LT04
    D
    L
    CD
    L
    C
    LT slot for assigning
    an Analog Terminal
    Station No.
    (The DLC card is not
    mounted in this slot.) 
    						
    							ND-45670 (E) CHAPTER 2
    Page 29
    Revision 2.0
    ANALOG PORT ADAPTER (1200 Series Enhancement)
    DESCRIPTION DATA
    Assign a key for Analog Terminal. • YY=00
    (1) Analog Terminal Station No. + + Key 
    No.
    (2) X-XXXX: Analog Terminal Station No. 
    assigned by CM10.
    Assign an Analog Terminal Station No. as 
    Prime Line.(1) X-XXXX: Analog Terminal Station No.
    (2) X-XXXX: Analog Terminal Station No.
    Provide the Analog Port Adapter to the 
    required station.• YY=34
    (1) X-XXXX: Analog Terminal Station No.
    (2) 0: To be provided
    Specify whether a ringing signal is sent to the 
    Analog Terminal.• YY=35
    (1) X-XXXX: Primary Extension No.
    (2) 0/1 : Not to be sent/To be sent
    Specify the PAD control of the Analog 
    Terminal.• YY=09
    (1) X-XXXX: Analog Terminal Station No.
    (2) 0/1 : Not Available/AvailableCM90
    CM93
    CM13
    END
    A
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 0
    Revision 2.0
    ANNOUNCEMENT SERVICE
    PROGRAMMING
    DESCRIPTION DATA
    Specify the Multi-Connection of the Digital 
    Announcement Trunk (PN-2DATA) on 
    Announcement Service. (1) 124 
    (2) 0/1 : Available/Not Available (Single 
    Connection)
    Assign a Digital Announcement Trunk Circuit 
    No. to the required LEN.
    Note:The Digital Announcement Trunk
    Circuit No. must be assigned to the
    first LEN (Level 0) and/or the third
    LEN (Level 2) of each LT slot.(1) LEN (0000-0511) 
    (2) EB000-EB127: Digital Announcement 
    Trunk Circuit No. 
    For PIM0/1: EB000-EB031 
    For PIM2/3: EB032-EB063 
    For PIM4/5: EB064-EB095 
    For PIM6/7: EB096-EB127 
    • CM12 YY = 02
    (1) X-XXXX:  Primary Extension No.
    (2) XX
     XX 
    *a: Service Restriction Class (A):  
    00-15
    • CM15 YY = 34 (Group 0) 
    • CM15 YY = 35 (Group 1) 
    • CM15 YY = 36 (Group 2) 
    • CM15 YY = 37 (Group 3) 
    • CM15 YY = 38 (Group 4) 
    • CM15 YY = 39 [Recording for An-
    nouncement Service (Group 0-4)] 
    (1) 00-15 : Service Restriction Class (A) 
    assigned by CM12 YY = 02 
    (2) 1 : Allowed 
    Assign access codes for Announcement 
    Service. • Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:  Access Code 
    (2) A03:  Recording message (Group 0-4) 
    A04:  Replaying message (Group 0)
    A05:  Replaying message (Group 1)
    A06:  Replaying message (Group 2) 
    A07:  Replaying message (Group 3)
    A08:  Replaying message (Group 4)
    A09:  Deleting message (Group 0-4) 
    CM08
    CM10 START
    A
    CM20
    CM12
    CM15*a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 31
    Revision 2.0
    ANNOUNCEMENT SERVICE
    Note 1:A maximum of five different announcements can be accessed. There is a limit of 10 Digital Announcement
    Trunk Circuit for each of the five different announcements. When recording an announcement, each Digital
    Announcement Trunk Circuit must be recorded individually.
    Note 2:Each time a station is connected to a Digital Announcement Trunk Circuit, the message will be repeated
    three times. The station will then be disconnected.
    Note 3:For the single connection of a Digital Announcement Trunk Circuit, the duration of an announcement is
    limited to 60 seconds. 
    Note 4:For the multi-connection of a Digital Announcement Trunk Circuit, the duration of replay for an announce-
    ment is programmable from 4 to 396 seconds.
    DESCRIPTION DATA
    When multi-connection is provided 
    (CM08124 = 0), specify the duration of 
    message replay for Announcement Service.•Y = 0 
    (1) 53
    (2) 01-99: 4-396 sec. in 4 sec. increments 
    If no data is set, the default setting is 60-64 
    seconds.
    Assign the function for each Digital 
    Announcement Trunk.• YY = 00
    (1) 000-127: Digital Announcement Trunk 
    Circuit No. assigned by CM10 
    (EB000-EB127)
    (2) 04X
     X
    *a: Group No. (0-4)
    *b: Message No. (0-9)
    To provide a Tie Line party with this service, 
    assign the Announcement Service Group 0-4 
    to the required Trunk Routes.• YY = 69 (Group 0)
    • YY = 70 (Group 1)
    • YY = 71 (Group 2)
    • YY = 72 (Group 3)
    • YY = 73 (Group 4)
    (1) 00-63 : Trunk Route No.
    (2) 1 : Allowed
    END
    CM41
    A
    CM49
    CM35*b *a 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 2
    Revision 2.0
    ANNOUNCEMENT SERVICE
    To provide a voice message when an incoming C.O. line/Tie line call has been transferred and encounters a busy or
    no answer condition:
    DESCRIPTION DATA
    Assign a Digital Announcement Trunk Circuit 
    No. to the required LEN.
    Note:The Digital Announcement Trunk
    Circuit No. must be assigned to the
    first LEN (Level 0) and/or the third
    LEN (Level 2) of each LT slot.(1) LEN (0000-0511) 
    (2) EB000-EB127: Digital Announcement 
    Trunk Circuit No. 
    For PIM0/1:  EB000-EB031 
    For PIM2/3:  EB032-EB063 
    For PIM4/5:  EB064-EB095 
    For PIM6/7:  EB096-EB127 
    Assign the feature for a voice message 
    connection to a transferred trunk when the 
    transferred destination does not answer or the 
    transferred destination is busy to the required 
    tenant. • YY = 50 (No Answer)
    (1) 00-63:  Tenant No. 
    (2) 0 
    • YY = 51 (Busy) 
    (1) 00-63:  Tenant No. 
    (2) 0 
    Assign the function for each Digital 
    Announcement Trunk.• YY = 00
    (1) 000-127: Digital Announcement Trunk 
    Circuit No. assigned by CM10 
    (EB000-EB127)
    (2) 06XX
    :  No Answer 
    *a: Message No. (00-63)
    07XX
    :  Busy
    *a: Message No. (00-63)
    • YY = 06 (No Answer)
    • YY = 07 (Busy) 
    (1) 00-63: Tenant No. of transferring station 
    (2) 00-63: Message No. assigned by YY = 
    00
    To record, replay, or delete a message, assign 
    the respective Digital Announcement Trunk 
    access code. • Y = 0-3 (Number Plan Group 0-3) 
    (1) X-XXX:  Access Code 
    (2) A00:  Record 
    A01:  Replay 
    A02:  Delete 
    CM10 START
    END
    CM65
    CM49
    CM20
    *a
    *a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 33
    Revision 2.0
    ANNOUNCEMENT SERVICE
    Note 5:Announcement Service can be used to provide a voice message when an incoming C.O. line/Tie line call
    has been transferred and encounters a busy or no answer condition. After the voice message is given, nor-
    mal call processing continues. 
    -This application can be programmed on a tenant basis.
    - Only one (1) message of up to 60 seconds can be recorded on an individual Digital Announcement Trunk
    Circuit. 
    - In this application, a minimum of two digital announcement Trunk Circuits are needed, one for busy
    condition, and one for no answer.
    - More than one Digital Announcement Trunk Circuit can be used, depending on traffic conditions.
    - System programming can be set to, wait until circuit(s) become free or immediately follow prepro-
    grammed normal call handling, if a busy condition is encountered.
    - Digital Announcement Trunk Circuits can be shared among tenants.
    - This feature does not function on Attendant transferred calls. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax2000 Ivs Feature Programming Manual