    							CHAPTER 2 ND-45670 (E)
    Pag e 1 54
    Revision 2.0
    CALL PICKUP-DIRECT
    PROGRAMMING
    DESCRIPTION DATA
    Assign Service Restriction Class (A) to each 
    station.• YY = 02
    (1) X-XXXX: Station Number
    (2) XX
     XX
    *a: Service Restriction Class (A)
    (00-15 )
    Assign this feature to Service Restriction 
    Class (A) assigned by CM12 YY = 02.• YY = 14
    (1) XX: Service Rest. Class (A) assigned 
    by CM12 YY = 02.
    (2) 1 : Allowed
    Assign the access code for Call Pickup-
    Direct.• Y = 0-3 ( Numbering Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 021: Call Pickup-Direct
    Assign a Call Pickup-Direct key to Multiline 
    Terminal, if required.• YY = 00
    (1) Primary Extension No. +   + Key No. 
    (2) F0021: Call Pickup-Direct
    START
    CM90
    CM12
    END
    CM15
    CM20
    *a
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 155
    Revision 2.0
    CALL PICKUP-GROUP
    PROGRAMMING
    Note 1:There is no limit to the amount of Call Pickup Groups.
    Note 2::
    The maximum number of stations within a group is 60. Individual stations can be assigned to only one Call
    Pickup Group.
    DESCRIPTION DATA
    Assign each Call Pickup Group, by assigning 
    station numbers within a group one by one 
    with the following operation:
    Example:
      For assigning Stations 300, 301 
    and 302 to the same Call Pickup 
    Group:
    1st Operation (1) 300
    (2) 301
    2nd Operation  (1) 301
    (2) 302
    3rd Operation  (1) 302
    (2) 300•Y = 0
    (1) X-XXXX:Station No. to be included in 
    the Call Pickup Group. 
    (2) X-XXXX:Another Station No. to be
    included in the same group.
    Assign the access code for Call Pickup-
    Group.• Y = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX:Access Code
    (2) 020 : Call Pickup-Group
    Assign a Call Pickup-Group key to each 
    Multiline Terminal, as required.• YY = 00
    (1) Primary Extension No. +   + Key No. 
    (2) F0020
    START
    CM16
    END
    CM20
    CM90
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 56
    Revision 2.0
    CALL PICKUP-DESIGNATED GROUP
    PROGRAMMING
    Note 1:There is no limit to the amount of Call Pickup Groups.
    Note 2:The maximum number of stations within a group is 60. Individual stations can be assigned to only one Call
    Pickup Group.
    DESCRIPTION DATA
    Assign each Call Pickup Group, by assigning 
    station numbers within a group one by one 
    with the following operation: 
    Example:
    For assigning Stations 300, 301 
    and 302 to the same Call Pickup 
    Group:
    1st Operation (1) 300 
    (2) 301 
    2nd Operation (1) 301
    (2) 302 
    3rd Operation (1) 302
    (2) 300•Y = 0
    (1) X-XXXX: Station No. to be included in 
    the Call Pickup Group.
    (2) X-XXXX: Another Station No. to be in-
    cluded in the same group. 
    Assign the Service Restriction Class (A) to 
    each station. • YY = 02
    (1) X-XXXX: Station Number
    (2) XX
     XX
    *a: Service Restriction Class (A) 
    (00-15 ) 
    Assign the Call Pickup-Direct feature to 
    Service Restriction Class (A) assigned by 
    CM12 YY = 02.• YY = 14
    (1) XX:Service Rest. Class (A) assigned by 
    CM12 YY = 02. 
    (2) 1 : Allowed 
    Assign an access code for Call Pickup-
    Designated Group.• Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX:Access Code (75)
    (2) 037 : Call Pickup-Designated Group 
    CM16
    CM15 START
    CM20
    END
    CM12
    *a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 157
    Revision 2.0
    CALL REDIRECT
    (1800 Series Enhancement)
    PROGRAMMING
    DESCRIPTION DATA
    Provide the Multiline Terminal with a Call 
    Redirect key for transferring a call to a 
    destination station or VMS.• YY=00
    (1) Primary Extension No. +   + Key No. 
    (2) F5011: Call Redirect 0
    (For transferring to a station as-
    signed by CM51 YY=22)
    F5012: Call Redirect 1
    (For transferring to a VMS as-
    signed by CM51 YY=18)
    Specify the destination VMS station of Call 
    Redirect, to each tenant.• YY=18
    (1) Tenant No. (00-63)
    (2) X-XXXX: VMS Station No.
    Specify the destination station of Call 
    Redirect,to each tenant.• YY=22
    (1) Tenant No. (00-63)
    (2) X-XXXX: Station No.CM90
    END
    CM51 START
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 58
    Revision 2.0
    CALL TRANSFER-ATTENDANT
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Access code for operator calls. • Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX: Access Code (0) 
    (2) 800 
    Specify the tenants to be handled by each 
    ATT Group.• Y =0-3 (ATT Group 0-3 assigned by 
    CM60 YY = 00) 
    (1) 00-63 (Tenant No.)
    (2) 0: To be handled
    Specify Call Transfer from a station before 
    the called SN610 ATTCON answers.(1) 063 
    (2) 0/1  Available/Not Available
    CM08 START
    END
    CM62
    CM20
    INITIAL 
    						
    							ND-45670 (E) CHAPTER 2
    Page 159
    Revision 2.0
    CAMP-ON
    PROGRAMMING
    Camp-On (Transfer Method)
    DESCRIPTION DATA
    Provide the system with the Camp-On by 
    Station feature. (1) 146 : Automatic Camp-On
    (2) 0 : Available
    (1) 147 : Manual Camp-On (Result of 
    Switch Hook-Flash while hearing 
    Busy Tone.)
    (2) 0 : Special Dial Tone allowing use of 
    Camp-On by Station access code.
    Assign the Class of Service for Camp-On to 
    the required stations.• CM12 YY = 02 
    [Service Rest. Class (A) (00-15 )]
    • CM15 YY = 16 (Transfer Method)
    (1) Service Rest. Class (A) (00-15) assigned 
    by CM12 YY = 02
    (2) 1  Allowed
    Specify the Camp-On Tone sent to a busy 
    station by Camp-On Transfer Method.(1) 068 
    (2) 0/1  Only once/Every 4 sec.
    Specify the timing for the Camp-On Recall 
    Tim er.•Y = 0
    (1) 26
    (2) 01-15: 8-120 sec. in 8 sec. increments
    If no data is set, the default setting is 24-
    32 seconds.
    Assign an access code for Camp-On by 
    Station (Transfer method).• Y = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access Code (*2)
    (2) 007: Camp-On by Station (Transfer 
    method)CM08 START
    END
    CM08
    CM41
    CM20
    CM12
    CM15 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 60
    Revision 2.0
    CAMP-ON
    Camp-On (Call Waiting Method)
    Note:For the data assignment of the ANS key to answer a Camp-On call from a Multiline Terminal, refer to the
    ANSWER Key. 
    DESCRIPTION DATA
    Provide the system with the Camp-On by 
    Station feature. (1) 146:Automatic Camp-On
    (2) 0 : Available
    (1) 147 : Manual Camp-On (Result of 
    Switch Hook Flash while hearing 
    Busy Tone.) 
    (2) 0 : Special Dial Tone allowing use of 
    Camp-On by access code.
    Assign the Class of Service for Camp-On to 
    the required stations. • CM12 YY = 02 
    [Service Rest. Class (A) (00-15 )] 
    • CM15 
    YY = 43 (Call Waiting Method - Set 
    from calling side) 
    YY = 44 (Call Waiting Method - An-
    swer from called side) 
    (1) Service Rest. Class (A) (00-15) as-
    signed by CM12 YY = 02
    (2) 1  Allowed
    Assign the access code for Camp-On by 
    Station (Call Waiting Method).• Y = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX:Access Code (#2)
    (2) A25 : Camp-On by Station (Call Wait-
    ing Method)CM08 START
    END
    CM20
    CM12
    CM15 
    						
    							ND-45670 (E) CHAPTER 2
    Page 161
    Revision 2.0
    CAMP-ON
    When using a Single-Digit Feature-Access Code for Camp-On, add the following system data.
    DESCRIPTION DATA
    To activate the Single Digit Feature Access 
    Code, set the data for 050, 051, 069 and 148 
    to “1”.(1) 050: * Button as Switch Hook Flash
    (2) 1  Ineffective
    (1) 051: # Button as Switch Hook Flash
    (2) 1  Ineffective
    (1) 069:Single Digit Dialing on BT Con-
    nection
    (2) 1  Step Call
    (1) 148:Same Last Digit Redialing on BT 
    Connection 
    (2) 1  Ineffective
    Provide the System with the Single Digit 
    Feature Access Code on BT Connection.(1) 208 
    (2) 0: AvailableCM08 START
    END 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 62
    Revision 2.0
    CCSA ACCESS
    PROGRAMMING
    In addition to the programming of E&M Tie Line Access, assign CCSA line to the required routes, as shown below.
    HARDWARE REQUIRED 
    PN-2ODT card ´ n
    DESCRIPTION DATA
    Assign CCSA line to required routes. • YY = 00
    (1) 00-63 (Trunk Route No.) (06)
    (2) 03: CCSA line
    Specify the ICI key, for the ATTCON, to 
    which a CCSA incoming call from the CCSA 
    network will terminate.• YY = 15
    (1) Trunk Route No. (00-63) 
    (2) ICI key 
    30: CCSA Incoming Call 0
    37: CCSA Incoming Call 7
    Assign the ICI key to the ATTCON, to which 
    a CCSA incoming call will terminate. • YY = 00
    (1) ATTCON No. +  + key No.
    (2) ICI key 
    F6030: Call Termination from CCSA 
    Line 0 
    F6037: Call Termination from CCSA 
    Line 7 
    Assign the CCSA access code. • Y = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access Code (85)
    (2) 100-163: Trunk Route 00-63 (06)CM35 START
    END
    CM90
    CM20
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 163
    Revision 2.0
    CENTREX COMPATIBILITY
    PROGRAMMING
    In addition to the programming of DIRECT OUTWARD DIALING (DOD), do the following programming.
    DESCRIPTION DATA
    Assign the Centrex Trunk function to the 
    required trunk routes. • YY = 86
    (1) Trunk Route No. (00-63) 
    (2) 0: Centrex Trunk
    Provide the capability for sending a 
    hookflash signal to the Centrex. • YY = 16
    (1) Trunk Route No. (00-63) 
    (2) 1  Sending
    Assign the access code for sending a 
    hookflash signal to the Centrex Line from a 
    PB Single-Line Telephone.• Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX: Access Code
    (2) A58 
    Assign the Centrex Trunk as a Prime Line to 
    the desired Multiline Terminal extension. (1) (1)X-XXXX (Primary Extension No.)
    (2) D XXX
     (Trunk No.) 
    *a: 000-255 
    CM35
    CM93 START
    END
    CM20