    							CHAPTER 2 ND-45670 (E)
    Pag e 3 20
    Revision 2.0
    NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
    PROGRAMMING 
    DESCRIPTION DATA
    Assign a Trunk Restriction Class to each 
    station. •  YY = 01
     (1)  X-XXXX (Station No.) 
     (2)  XX
    *a: Trunk Restriction Class in Night 
    Mode (1-7) 
    1 : Unrestricted (RCA) 
    2: Non-Restricted 1 (RCB) 
    3: Non-Restricted 2 (RCC) 
    4: Semi-Restricted 1 (RCD) 
    5: Semi-Restricted 2 (RCE) 
    6: Restricted 1 (RCF) 
    7: Restricted 2 (RCG) 
    Assign the Class of Service for TAS to the 
    required stations. •  CM12 YY = 02 
    Service Restriction Class B (00-15 ) 
    •  CMI5 YY = 53 
     (1)  Service Restriction Class B (00-15) as-
    signed by CM12 YY = 02
     (2)  1 : Allowed 
    Assign TAS as the terminating system in 
    Night Mode for the required trunks. •  YY = 03
     (1)  000-255 (Trunk No.) 
     (2)  13: TAS 
    Assign the TAS Group No. to the trunks 
    assigned by YY = 03. •  YY = 17
     (1)  000-255 (Trunk No.) 
     (2)  00-63 (TAS Group No.) 
    CM12 START
    A
    CM30
    CM12
    CM15
    *a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 321
    Revision 2.0
    NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
    DESCRIPTION DATA
    Specify the function of each type of TAS 
    within a system.•  Y = 0-4 (TAS Answer A-E) 
     (1)  Type of Call
    1: C.O. Incoming Call 
    2: Tie Line/DID 
    3: C.O. Incoming Call in Night Mode 
    4: Overflowed DIT Call
     (2)  0/1 : Cannot be answered/Can be an-
    swered 
     (1)  7: A call terminated to a different ten-
    ant.
     (2)  0/1 : Can be answered 
    Assign the access code for each type of TAS 
    (TAS Answer A-E) assigned by CM53. •  Y = 0-3 (Numbering Plan Group 0-3) 
     (1)  X-XXX: Access Code (72) 
     (2)  047: TAS Answer A 
    048: TAS Answer B 
    049: TAS Answer C 
    050: TAS Answer D 
    051: TAS Answer E 
    Specify the Tenants allowing TAS Answer 
    between them. • Y = 0
     (1)  XX
     XX
    *a: 00-63 (Tenant No. of TAS Answer 
    station) 
    *b: 00-63 (Tenant No. of Trunk) 
     (2)  0/1 : Allowed/Restricted 
    END
    CM53
    A
    CM20
    CM63
    0
    1
    2
    3
    4
    01347 (1)
    Y
    0/1
    0/1
    0/1
    0/1
    0/1
    0/1
    0/1
    0/1
    0/1
    0/10/1
    0/1
    0/1
    0/1
    0/10/1
    0/1
    0/1
    0/1
    0/10/1
    0/1
    0/1
    0/1
    0/1TAS
    Answer A
    TAS
    Answer B
    TAS
    Answer C
    TAS
    Answer D
    TAS
    Answer E
    *b *a 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 22
    Revision 2.0
    NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
    To provide the External TAS Indicator using the PN-DK00 card:
    To provide the Telephone set for TAS Indication using the PN-4LC card:DESCRIPTION
    DATA
    Assign the PN-DK00 card No. to the required 
    LEN. (1)  LEN (0000-0511) 
     (2)  E800-831 (PN-DK00 Card No.) 
    For PIM0/1: E800-E807 
    For PIM2/3: E808-E815 
    For PIM4/5: E816-E823 
    For PIM6/7: E824-E831 
    Assign the TAS Group No. assigned by 
    CM30 YY = 17 to the circuit No. of the PN-
    DK00 card.  (1)  XX
     X (Circuit No.) 
    *a: Card No. (00-31) assigned by CM10 
    (E800-E831) 
    *b: Circuit No. (0-3) 
     (2)  13XX
    *a: 00-63 (TAS Group No.00-63 as-
    signed by CM30 YY = 17) 
    Specify the indication pattern on the External 
    TAS Indicator.  (1)  00
     (2)  01 : 30 IPM (1 sec. ON/OFF) 
    02: 60 IPM (0.5 sec. ON/OFF) 
    03: 120 IPM (0.25 sec. ON/OFF) 
    07: Steadily on.
    DESCRIPTION DATA
    Assign the TAS Buzzer No. (Telephone set for 
    TAS Indication) to the required LEN.
    The TAS Buzzer No. must correspond to the 
    TAS Group No. assigned by CM30 YY = 17.
    E600®TAS Group 00
    E663®TAS  Group 63 (1)  LEN (0000-0511) 
     (2)  E600-E663 (TAS Buzzer No.)
    CM10 START
    CM59
    END
    CM44*b *a
    *a
    CM10 START
    END 
    						
    							ND-45670 (E) CHAPTER 2
    Page 323
    Revision 2.0
    NIGHT SERVICE: TRUNK ANSWER ANY STATION (TAS)
    HARDWARE REQUIRED 
    To provide the External TAS Indicator: 
    • PN-DK00
    • Indicator 
    Requirement for External Indicator
    Control Method: Ground/Battery (-24 V) (Max.125 mA) 
    Type:  Visual and/or Audible type with volume control
    Make the following connections at the MDF according to the type of the indicator. For details, refer to the MDF
    cross connection for a TAS Indicator in the INSTALLATION PROCEDURE MANUAL.
    To provide the Telephone set for TAS Indication: 
    • PN-4LC card (Four telephone sets per card can be equipped.) 
    • Conventional telephone sets 
    PBX
    PN-DK00 CARD
    PZ-PW86 CARD
    G
    PBX
    PN-DK00 CARDMDF
    MDFEXTERNAL INDICATOR
    WITH BATTERY
    EXTERNAL INDICATOR WITH
    BATTERY (GROUND START)IND
    IND
    G 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 24
    Revision 2.0
    OFF-HOOK ALARM
    PROGRAMMING
    DESCRIPTION DATA
    Provide this feature for the required stations.  •  YY = 02
    (1) X-XXX (Station No.) 
    (2)  0: To be provided 
    Assign the destination for Off-Hook Alarm 
    to a Station or SN610 ATTCON. •  YY = 12 
    (1)  Tenant No. (00-63) 
    (2) X-XXXX (Station No.) 
    E000: SN610 ATTCON
    If the Attendant Console is designated as the 
    destination of Off-Hook Alarm by CM51 YY 
    = 12, assign an EMG key for the Off-Hook 
    Alarm to any Key. •  YY = 00
    (1)  ATTCON No. +   + Key No.
    (2)  F6056: Emergency Call 
    Specify the timing for Off-Hook Alarm. •  Y = 0 
    (1) 22
    (2)  01-08: 4-32 sec. in 4 sec. increments
    If no data is set, default setting is 28-32 sec-
    onds.
    Specify the service to be applied for an Off-
    Hook Alarm Call to a busy destination.•  CM12 YY = 07 
    (1)  X-XXXX (Station No. of destination) 
    (2)  Service Rest. Class C (00-15 )
    •  CM15 YY = 97, YY = 98 
    (1)  Service Rest. Class C (00-15) assigned 
    by CM12 YY = 07.
    (2) See left column.CM13 START
    CM41
    CM12
    CM15
    END
    CM90
    CM51
    ,
    YY
    MEANING OF DATA
    97 98
    00Call Waiting (When UCD Pilot 
    Station and CM08-212 = 0)
    01UCD (When UCD Pilot 
    Station and CM08-212 = 1)
    10Call Waiting (For Ordinary 
    Station)
    1 1 Hunting (For Ordinary Station) 
    						
    							ND-45670 (E) CHAPTER 2
    Page 325
    Revision 2.0
    OFF PREMISES EXTENSION
    PROGRAMMING 
    HARDWARE REQUIRED 
    PN-AUCA card
    DESCRIPTION DATA
    Remove the PAD on Off Premises Extension.  •  YY  =  09
     (1)  X-XXXX (Station Number) 
     (2)  0: No PAD (6 dB) CM13 START
    END 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 26
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    PROGRAMMING
    1. In case of a system with AP card (PN-AP01):
    DESCRIPTION DATA
    Assign the slot number to AP card
    Note:Set SENSE switch on the card to the
    slot number assigned(1) Slot No. (04-15)
    (2) 07: PN-AP01 card
    Designate the AP card for Authorization 
    Code.(1) 216:Designation of Processor for Autho-
    rization Code
    (2) 1 : AP (PN-AP01)
    Specify the Service Set Tone after dialling the 
    access code for Authorization Code.(1) 362:Provision of Service Set Tone after 
    dialling the access code
    (2) 1 : To be provided
    Set the data for 281 to 1. (Maid ID Code is not 
    used.)(1) 281
    (2) 1 : Not available
    Assign the Service Restriction Class (A) 
    allowed for Authorization Code feature.• YY=31 (Authorization Code)
    (1) Service Restriction Class (A) (00-15)
    (2) 1 : Allowed
    Assign allowed class and restricted class for 
    Maid Status feature.• YY=75 (Maid Status)
    (1) Service Restriction Class (B) (00-15)
    (2) 0: Restricted
    1 : Allowed
    To the station that uses PAD LOCK feature, 
    assign the Service Restriction Class (A) 
    allowed for Authorization Code feature. 
    Moreover, to all the station, assign the Service 
    Restriction Class (B) restricted for Maid 
    Status feature.• YY=02
    (1) X-XXXX: Station No.
    (2) XX
     XX
    Service Restriction Class (A)
    Service Restriction Class (B)
    Assign the access code for Authorization 
    Code.• Y=0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 086: Authorization Code
    CM05
    CM08
    CM15
    CM12
    CM20
    A START
    INITIAL 
    						
    							ND-45670 (E) CHAPTER 2
    Page 327
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    Specify the maximum number of digits for 
    Authorization Code.(1) 11:Authorization Code Max. digits
    (2) Max. number of digits
    01: 1 digit
    08: 8 digits
    NONE : 8 digits
    Specify the conditions for adding Check Code 
    to each Authorization Code.
    Check Code consists of 2 digits: 1st and 2nd 
    Check Code which are generated by the AP 
    according to the conditions specified by Y=0 
    and Y=1.
    Authorization Code:
    X
    1 X2 X3 X4 X5 X6 X7 X8 C1 C2
    X: Significant Digit for Check Code• Y=0 (Designation of Significant 
    digit for Check Code)
    (1) 0: For 1st Check Code
    1: For 2nd Check Code
    (2) 00 X
     X: Significant digit designation
    5th-8th digit (0-F)
    1st-4th digit (0-F)
    (See left column)
    If no Check Code is required, set 
    data=0000 to both 1st and 2nd 
    Check Code.
    • Y=1 (Setting of Check Sum Data for 
    generating Check Code)
    (1) 0:For 1st Check Code
    (2) 1: For 2nd Check Code
    0-9: Check Sum Data (Enter 
    desired value)
    CM42
    CMD5
    A
    B
    ~
    ~
    ID Code programmedCheck Code
    X1X2X3X4
    X5X6X7X8
    0 No Check Code
    1X
    2X
    3XX
    4X
    5XX
    6XX
    7 XXX
    8X
    9X X
    AXX
    BXXX
    CXX
    DXXX
    EXXX
    F XXXX
    DIGIT
    DATA 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 28
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    Set the Authorization Code and the Temporary
    Service Class given by CM15. 
    Service Restriction Class (B) of the Temporary
    Service Class should be set to the allowed class
    for Maid Status.
    • Temporary Service Class.
    2 X
    2 X3 X4 X5 X6 X7 X8 X9
    •
    (1)
    (2)Y=3
    X-X...X: Authorization Code
    2 X
    2 ...X9 (9 digits)
    (See column below)
    2: Type of Temporary Service Class as per 
    X
    2...X9 
    Trunk Restriction Class (01-08)
    Service Restriction Class (A) (01-15)
    Service Restriction Class (B) (01-15)
    (Allowed class for Maid Status)
    Service Restriction Class (C) (01-15)
    Assign the access code for Maid Status. •
    (1)
    (2)YY=0-3 (Numbering Plan Group 0-3)
    X-XXX (Access Code)
    029
    Assign the Class of Service for Maid Status. (1)
    (2)X-XXXX: Station No.
    Service Class No. (0-15)
    Assign the Maid Status Processing to the 
    Service Class assigned by CMD015.(1)
    (2)XX
     06
    Service Class No. assigned by
    CMD015
    1: Yes
    CMD5
    CM20
    C
    CMD015
    CMD016
    B 
    						
    							ND-45670 (E) CHAPTER 2
    Page 329
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    Allow each Status Number (Restricted/
    Normal) to change the Status Number from 
    the station.
    Note:Desired number can be assigned for
    the Status Number of each status.(1) 1
     31
    Status No. (Restricted) Note
    Allowed to change the Status
    No. from the station
    (2) 1: Yes
    (1) 2
     31
    Status No. (Normal) Note
    Allowed to change the Status
    No. from the station.
    (2) 1: Yes
    Assign the originating function, the incoming 
    call function, and the other function to each 
    Status Number as following table.(1) 1
     00
    Status No. (Restricted)
    No originating allowed (Room
    Cut Off)
    (2) 1: Yes
    (1) 1
     01
    Status No. (Restricted)
    Originating allowed (Room Cut
    Off Reset)
    (2) 0 : No
    (1) 2
     00
    Status No. (Normal)
    No originating allowed (Room
    Cut Off)
    (2) 0 : No
    (1) 2
     01
    Status No. (Normal)
    Originating allowed (Room Cut
    Off Reset)
    (2) 1: Yes
    CMD031
    D
    C
    ROOM 
    STATUS No.FUNCTION
    00 01 02 03 04 05 06 07
    1 
    (Restricted)100/10/10000
    2 
    (Normal)010/10/10000 
    						
    All NEC manuals Comments (0)