Home > NEC > Communications System > NEC Neax2000 Ivs Feature Programming Manual

NEC Neax2000 Ivs Feature Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax2000 Ivs Feature Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 479
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 04
    Revision 2.0
    DIRECT INWARD SYSTEM ACCESS (DISA)
    Note 1:Up to 1,000 Direct Inward System Access (DISA) codes combined with Authorization Codes and Forced
    Account Codes can be defined. 
    Note 2:When deleting all ID codes stored in the PN-AP01 card at one time, do the following operation:
     + D60 +   + 0000 +   + CCC +  
    HARDWARE REQUIRED 
    PN-AP01 card ´ 1 (If 1,000 codes and/or Check Code is provided.)
    PN-2DATA card x n (n = 1-128) (If a Digital Announcement Trunk is required for the DISA.) ST
    DEDEEXE 
    						
    							ND-45670 (E) CHAPTER 2
    Page 205
    Revision 2.0
    DIRECT INWARD TERMINATION (DIT)
    PROGRAMMING 
    DESCRIPTION DATA
    Assign the data for terminating system in Day 
    Mode and Night Mode, to each Loop/Ground 
    Start trunk, respectively. • YY = 02 (Day Mode)/YY = 03 (Night 
    Mode)
    (1) Trunk No. (000-255)
    (2) 04: Direct-In Termination
    Assign the station number to be terminated by 
    DIT in Day Mode and Night Mode 
    respectively.• YY = 04 (Day Mode)/YY = 05 (Night 
    Mode)
    (1) Trunk No. (000-255)
    (2) X-XXXX: Station No.
    Assign the destination to be rerouted when the 
    DIT Station is busy/not available in Day Mode 
    and Night Mode respectively.• YY = 13 (Day Mode)/YY = 14 (Night 
    Mode)
    (1) Trunk No. (000-255)
    (2) 01: TAS BUZZER 
    04: SN610 ATTCON
    06: Automatic Camp-On 
    15: Waiting until the DIT Station 
    becomes idle.
    Assign the transfer destination for an 
    unanswered DIT call in the Day Mode and 
    Night Mode, respectively.• YY = 15 (Day)/YY = 16 (Night)
    (1) Trunk No. (000-255)
    (2) 01: SN610 ATTCON
    03: TAS
    15: To be continued DIT
    Specify the timing for an unanswered call to a 
    DIT destination.•Y = 0
    (1) 01
    (2) 01-30: 4-120 sec. in 4 sec. increments
    If no data is set, the default setting is 32-
    36 seconds.
    Set the ring rate on a DIT call. (1) 179 
    (2) 0/1: As per the data assigned by 
    CM35 YY = 33/0.4 sec. ON, 0.2 
    sec. OFF, 0.4 sec. ON, 2 sec. OFF.CM30
    END
    START
    CM41
    CM08 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 06
    Revision 2.0
    DIRECT OUTWARD DIALING (DOD)
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Trunk Numbers to the required 
    LENs.(1) LEN (0000-0511) 
    (2) Trunk No. (D000-D255)
    Assign the data for Direct Outward Dialing to 
    the Trunk No. assigned by CM10. 
    Note:For Resident System Program, refer
    to the Command Manual. • YY = 00 (Trunk Route Allocation) 
    (1) Trunk No. (000-255)
    (2) Route No. (00-63) Note
     
    • YY = 01 (Tenant Allocation)
    (1) Trunk No. (000-255)
    (2) Tenant No. (00-63) (01)
    • YY = 08 (Restriction on Night Mode)
    (1) Trunk No. (000-255)
    (2) 0/1 : Restricted/Allowed
    CM10
    CM30 START
    A 
    						
    							ND-45670 (E) CHAPTER 2
    Page 207
    Revision 2.0
    DIRECT OUTWARD DIALING (DOD)
    DESCRIPTION DATA
    Assign the data for Direct Outward Dialing to 
    the Route No. assigned by CM30 YY = 00. 
    Note:For Resident System Program, refer
    to the Command Manual. • YY = 00 (Kind of Route)
    (1) Trunk Route No. (00-63)
    (2) 00: DDD 
    01: FX
    02: WATS
    03: CCSA
    • YY = 01 (Type of Signal) 
    (1) Trunk Route No. (00-63) 
    (2) 2: DP
    4: DTMF 
    • YY = 02 (OG/IC) 
    (1) Trunk Route No. (00-63)
    (2) 2 : Outgoing 
    3:Bothway 
    • YY = 04 (Answer Signal Condition)
    (1) Trunk Route No. (00-63)
    (2) 1 : Answer Signal by Polarity Re-
    versal 
    7:No Answer Signal 
    In case of no Answer Signal, system recog-
    nizes the answer in timing set by CM41-03. 
    • YY = 05 (Release Signal Condition) 
    (1) Trunk Route No. (00-63)
    (2) 0 : No Release Signal from C.O.
    1:Release Signal from C.O. 
    • YY = 08 (Dial Pulse Sending) 
    (1) Trunk Route No. (00-63) 
    (2) 3: To be sent
    • YY = 09 (Incoming Connection Signal-
    ling) 
    (1) Trunk Route No. (00-63) 
    (2) 01 : Ring Down (Ground Start) 
    15:Ring Down (Loop Start)
    CM35
    B
    A 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 08
    Revision 2.0
    DIRECT OUTWARD DIALING (DOD)
    Note:For the Trunk Restriction Class, refer to Class of Service Individual.
    DESCRIPTION DATA
    According to the characteristics of each C.O. 
    line, assign the data for DP/DTMF Sender to 
    each route. 
    For the details of the command, refer to the 
    Command Manual.
    Note:For Resident System Program, refer
    to the Command Manual. • YY = 20 (Sender Start Condition) 
    • YY = 21 (Sender Prepause Timing) 
    • YY = 23 (DP-Inter Digital Pause) 
    • YY = 24 (DTMF-Inter Digital Pause) 
    • YY = 25 (DP-Make Ratio)
    • YY = 26 (DTMF Signal Width)
    • YY = 45 (DP Sender Release Timing) 
    • YY = 46 (DTMF Sender Release 
    Timing) 
    Specify the timing for Interdigital Pause on 
    outgoing C.O. call.•Y = 0
    (1) 27
    (2) 01-14: 1-14 sec. in 1 sec. increments
    If no data is set, the default setting is 7 
    seconds.
    Assign the access code to each route.  • Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX: Access Code
    (2) 100-163: Route No. (00-63)
    Assign the trunk appearance line key on a 
    Multiline Terminal, if provided.• YY = 00
    (1) Primary Extension No. +    + Key No.
    (2) DXXX (Trunk No. 000-255)
    CM35
    B
    END
    CM20
    CM90
    CM41
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 209
    Revision 2.0
    DIRECT STATION SELECTION/BUSY LAMP FIELD (DSS/BLF) CONSOLE
    PROGRAMMING
    HARDWARE REQUIRED 
    DSS Console 
    PN-2DLCB/4DLCA card (Two or four DSS Consoles can be accommodated per card) 
    DESCRIPTION DATA
    Assign the DSS Console Number to its 
    associated LEN.(1) 0000-0511 (LEN)
    (2) DSS Console No. 
    E100-E107: For PIM0/1 
    E108-E115: For PIM2/3 
    E116-E123: For PIM4/5 
    E124-E131: For PIM6/7 
    Assign a single-line station, Multiline 
    Terminal, or SN610 ATTCON to work in 
    conjunction with the DSS Console.(1) 00-31 (DSS Console Number: Last two 
    digits of E100-E131 assigned by 
    CM10) 
    (2) X-XXXX (Station Number/Primary 
    Extension No. of Multiline Terminal)
    E000-E007 (SN610 ATTCON No.) 
    Assign the station and trunk numbers, as 
    needed, to the keys on each DSS Console. (1) 00-31 (DSS Console Number) +   
    + DSS Key Number (00-59)
    (2) X-XXXX (Station Number)
    D XXX
    *a: 000-255 (Trunk Number)
    Assign a Do Not Disturb and Message 
    waiting function key, if needed, on each DSS 
    Console. (1) 00-31 (DSS Console Number) +   + 
    Function key No. (57-59)
    (2) F1049: Message Waiting Set/Reset
    F1053: Do Not Disturb Set/Reset 
    When providing Do Not Disturb or Message 
    Waiting function key, assign a changing 
    Function key on each DSS Console.(1) 00-31 (DSS Console Number) +    + 
    Function key No. (56) 
    (2) F1052: Changing Function 
    Specify the type of busy indication on the 
    BLF of the DSS Console as Station Base or 
    Extension Base.(1) 269
    (2) 0/1: Station Base/Extension Base 
    CM10
    END
    START
    CM97
    CM08
    CM96
    ,
    *a
    ,
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 10
    Revision 2.0
    DISTINCTIVE RINGING
    PROGRAMMING
    DESCRIPTION DATA
    Select the ringing pattern on an internal and 
    Direct-In Termination Call, Direct Inward 
    Dialing, DISA, and Automated Attendant. (1) 138 (For Internal)
    (2) 0/1: 2 sec. ON, 4 sec. OFF/1 sec. 
    ON, 2 sec. OFF. 
    (1) 179 (For DIT Call)
    (2) 0/1: As per CM35 YY = 33/0.4 sec. 
    ON, 0.2 sec. OFF, 0.4 sec. ON, 2 
    sec. OFF. 
    (1) 180 (For DID, DISA and Automated 
    Attendant) 
    (2) 0/1:0.2 sec. ON, 0.2 sec. OFF, 0.2 
    sec. ON, 0.2 sec. OFF, 0.2 sec. 
    ON, 0.2 sec. OFF/As per the 
    data CM35 YY = 33 
    Select the ringing pattern on an external call. 
    Note:For incoming calls to a Direct Trunk
    Appearance key on Multiline Termi-
    nals, the special ringing, 0.2 sec. ON,
    0.2 sec. OFF, 0.2 sec. ON, 0.2 sec.
    OFF, will be applied.
    • YY = 33
    (1) Trunk Route No. (00-63)
    (2) 0 : 0.4 sec. ON, 0.2 sec. OFF 
    Note 
    0.4 sec. ON, 2.0 sec. OFF 
    Note
    1 : 0.4 sec. ON, 0.2 sec. OFF
    0.4 sec. ON, 2.0 sec. OFF 
    2 : 1 sec. ON, 2 sec. OFF
    3:2 sec. ON, 4 sec. OFF
    Select the ringing pattern on station calls 
    with a trunk line placed in Consultation Hold.(1) 137 
    (2) 0: Change from Internal Ringing 
    (CM08-138) to External Ringing 
    (CM35 YY = 33) when transfer-
    ring a call
    1: External Ringing (CM35 YY = 
    33)
    CM08
    END
    START
    CM35
    CM08 
    						
    							ND-45670 (E) CHAPTER 2
    Page 211
    Revision 2.0
    DISTINCTIVE RINGING
    To provide a distinctive lamp indication for Multiline Terminals during a call termination, do the following program-
    ming:
    DESCRIPTION DATA
    Specify the lamp color for an incoming 
    external call. 
    Note:The lamp color for incoming inter-
    nal calls is red (120 IPM flashing).
    For indicating the termination of a
    transferred external incoming call,
    the flashing lamp color depends on
    CM08-137. • YY = 32
    (1) Trunk route number (00-63) 
    (2) 0/1: Green/Red 
    END
    START
    CM35 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 2 12
    Revision 2.0
    DO NOT DISTURB
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Class of Service for Do Not 
    Disturb to the required stations.• CM12 YY=02: Service Rest. Class (A)
    (00-15t)
    • CM15 YY=19
    (1) Service Rest. Class (A) (00-15) assigned 
    by CM12 YY=02
    (2) 1 : Allowed
    Assign the group of stations in Do Not 
    Disturb. Do Not Disturb is set to these stations 
    (assigned by this command) simultaneously 
    by operation from an Attendant Console.• YY=00
    (1) X-XXXX (Station No.)
    (2) 0: To be provided
    Assign the access code for Do Not Disturb 
    Set/Cancel.• Y=0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX: Access Code (*8, #8) 
    (2) 022: Set 
    023: Cancel
    Assign the destination to which a call is 
    transferred when the called station is set to Do 
    Not Disturb.• YY=10 
    (1) 00-63 (Tenant No.) 
    (2) X-XXXX (Station No.) 
    E000 (SN610 ATTCON)
    Assign a DND function key to a Multiline 
    Terminal, if needed.• YY=00 
    (1) Primary Extension No. +   + Key No. 
    (2) F0022: Do Not Disturb Set/Reset
    Assign DND and DNDOVR function keys to 
    the SN610 ATTCON.
    Note:By Resident System Program, a DN-
    DOVR key is assigned as a soft key,
    on the SN610 ATTCON.• YY=00 
    (1) ATTCON No. +   + Key No. 
    (2) F6102: DND 
    F6103: DND Override
    F6104: RESET
    CM12
    CM15
    CM20
    CM51
    A
    CM90 START
    CM13
    ,
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 213
    Revision 2.0
    DO NOT DISTURB
    DESCRIPTION DATA
    Specify the Call Forwarding-Busy Line/
    Station Hunting for a station set for Do Not 
    Disturb.240 
    0: Available 
    1 : Not Available
    For a system using multiple tenants, specify 
    for which tenant (the calling or called station) 
    the assignment refers to CM51 YY=10. CM51 
    YY=10 determines the destination to which a 
    call is transferred when the called station is in 
    Do Not Disturb.241 
    0:  Tenant of called station 
    1 :  Tenant of calling station
    Select the Dial Tone on Setting Do Not 
    Disturb. (1300 Series Enhancement)Y=2 
    14 (Dial Tone on Setting Do Not Disturb) 
    0:  Special Dial Tone (Stutter Dial Tone)
    1 : Dial ToneCM08
    A
    CM48
    END
    INITIAL 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax2000 Ivs Feature Programming Manual