    							CHAPTER 2 ND-45670 (E)
    Pag e 4 02
    Revision 2.0
    TRUNK-TO-TRUNK CONNECTION
    DESCRIPTION DATA
    Assign the Service Restriction Class C to each 
    station.• YY = 07
    (1) X-XXXX:Primary Extension No.
    (2) XX:Service Restriction Class C (00-15)
    Provide the switch hook flash capability dur-
    ing C.O. line connection, to the required sta-
    tions.• YY = 90, 91
    (1) 00-15:Service Restriction Class C
    (2) 1 :Allowed
    Specify the combination of trunk routes al-
    lowing the Trunk to Trunk Connection.(1) XX
     XX
    Incoming trunk route 00-63
    Outgoing trunk route 00-63
    (2) 0/1 : Allowed/Restricted
    Provide the system with Ring Transfer for 
    Call Transfer-All Calls to a trunk when a sta-
    tion holds another station or trunk.(1) 253
    (2) 0: Allowed
    Provide the system with forced disconnection 
    when a tandem call duration passes a predeter-
    mined time.(1) 029
    (2) 0/1 : Available/Not available
    Allow or restrict forced disconnection of tan-
    dem connection for the incoming trunk route.
    This data is available when CM08-029 is set 
    to 0.• YYY = 119
    (1) 00-63:Trunk route No.
    (2) 0/1 :Allowed/Restricted
    Specify the forced disconnection timing for 
    tandem call.•Y = 0
    (1) 54
    (2) 01-06:64-224 min.
    (32 min. increments)
    If no data is set, the default setting is 128 min.
    CM12
    A
    CM08
    CM35
    CM15
    CM36
    CM41 START 
    						
    							ND-45670 (E) CHAPTER 2
    Page 403
    Revision 2.0
    TRUNK-TO-TRUNK CONNECTION
    DESCRIPTION DATA
    Provide the system with Trunk to Trunk Con-
    nection when no release signal arrives from 
    the incoming trunk route and answer signal ar-
    rives from the outgoing trunk route.(1) 324
    (2) 0/1 :Available/Not available
    Provide the system with Trunk to Trunk Con-
    nection transferred by a station or an atten-
    dant, when no answer signal arrives and 
    release signal arrives from the outgoing trunk 
    route.(1) 028
    (2) 0/1 :Available/Not available
    Specify the forced disconnection timing for 
    tandem connection when the called party does 
    not answer.
    This data is available when no release signal 
    arrives from incoming trunk route.•Y = 0
    (1) 55
    (2) 01-13:12-60 sec.
    (4 sec. increments)
    If no data is set, the default setting is 20-24 
    sec.
    CM41
    END
    CM08
    A 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 04
    Revision 2.0
    TRUNK-TO-TRUNK CONNECTION
    To provide the AMP trunk for Trunk-to-Trunk Connection (1500 Series Enhancement):
    DESCRIPTION DATA
    Assign the Card Number of the AMP trunk 
    (PN-2AMP).
    Maximum of two digits are available.
    Note:The AMP card number must be
    assigned to both of the first LEN
    (Level 0) and the third LEN (Level 2)
    of each slot.(1) LEN (0000-0511)
    (2) Card No. of AMP trunk
    C100-C115 : For PIM0/1
    C116-C131 : For PIM2/3
    C132-C147 : For PIM4/5
    C148-C163 : For PIM6/7
    Assign the AMP patterns to each combination 
    of the trunk routes.• YY = 00
    (1) XX
     XX
    Incoming trunk route 00-63
    Outgoing trunk route 00-63
    (2) 00-14:AMP pattern No. 00-14
    15 :  Not use the AMP trunk
    Assign the gain value of each AMP pattern. • YY = 01
    (1) 00-14: AMP pattern No. 00-14
    (2) X
     X
    Fixed gain
    0 : 12 dB
    1 : 8 dB
    2 : 4 dB
    3 : 0 dB
    AGC (Automatic Gain Control)
    0 : 0 dBr
    1:+4 dBr
    2 : –4 dBr
    3  : Through (assigned by
    Fixed Gain)
    Assign the Echo Canceller function to each 
    AMP pattern.• YY = 02
    (1) 00-14:AMP pattern No. 00-14
    (2) 0:Through
    1 : Normal
    Assign the Gain Controller of Echo Canceller 
    to each AMP pattern.• YY = 03
    (1) 00-14: AMP pattern No. 00-14
    (2) 0 :ON
    1:OFF
    CM10
    A
    CM38 START 
    						
    							ND-45670 (E) CHAPTER 2
    Page 405
    Revision 2.0
    TRUNK-TO-TRUNK CONNECTION
    DESCRIPTION DATA
    Select the Tone Disabler’s mode on each AMP 
    pattern.• YY=04
    (1) 00-14: AMP pattern No. 00-14
    (2) 0:G164
    1 : G165
    Specify the Detect Timing of Tone Disabler on 
    each AMP pattern.• YY=05
    (1) 00-14: AMP pattern No. 00-14
    (2) 0:0 sec.
    1 : 2 sec.
    Specify the channels connected to each AMP 
    pattern.• YY=06
    (1) 00-14: AMP pattern No. 00-14
    (2) 0:Incoming route: Tie Line
    Outgoing route: C.O. Line
    1 :Incoming route: C.O. Line
    Outgoing route: Tie Line
    Specify the Timing of AMP trunk connection 
    on each AMP pattern.• YY=07
    (1) 00-14: AMP pattern No. 00-14
    (2) 0:When dialing is finished
    1 :When answering
    CM38
    C
    END 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 06
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    PROGRAMMING
    To activate UCD:
    DESCRIPTION DATA
    For each UCD Group, assign station numbers, 
    one by one, in the order of hunting. 
    Note:Up to 60 stations can be assigned
    into a single UCD group.
    Example:
     For setting Station Numbers 200, 
    201, 202 into one UCD Group. 
    1st Operation (1) 200 
    (2) 200
    2nd Operation(1) 201
    (2) 202
    3rd Operation (1) 202
    (2) 200•Y = 0
    (1) X-XXXX (Station No.)
    (2) X-XXXX (Another Station No. to be 
    linked) 
    Assign the Pilot Station and Member Station. • Y = 1
    (1) X-XXXX (UCD Station No.) 
    (2) 1/0 : Pilot Station/Member Station 
    Assign the UCD Group Number. • Y = 2
    (1) X-XXXX (UCD Station No.) 
    (2) 00-15 (UCD Group 00-15)
    Specify the UCD service for each type of call. • Y = 4 (Internal Call: from station/AT-
    TCON) 
    (1) X-XXXX (Pilot Station No. of the UCD 
    Group)
    (2) 0/1 : Not to be provided/To be provid-
    ed 
    • Y = 5 (C.O. Incoming Call: DDD: FX/
    WATS) 
    (1) X-XXXX (Pilot Station No. of the UCD 
    Group)
    (2) 0/1 : Not to be provided/To be provid-
    ed
    CM17 START
    A
    3rd 1st
    2nd 200
    202 201 
    						
    							ND-45670 (E) CHAPTER 2
    Page 407
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    DESCRIPTION DATA
    • Y = 6 (Tie Line Incoming Call) 
    (1) X-XXXX (Pilot Station No. of the UCD 
    Group)
    (2) 0/1 : Not to be provided/To be provid-
    ed 
    • Y = 7 (DID Call) 
    (1) X-XXXX (Pilot Station No. of the UCD 
    Group)
    (2) 0/1 :Not to be provided/To be 
    provided
    • Y=B (Designation of the number of 
    queuing in each UCD group)
    (1) X-XXXX (Pilot Station No. of the UCD 
    Group)
    (2) 0/1 : To be provided (See CM42-16)/
    Not to be provided
    Specify the maximum number of queuing in 
    each UCD group.(1) 16
    (2) 01-99 (Number of queuing in each UCD 
    group)
    Specify the basic call answer delay time for 
    use in PEG Count analysis.•Y = 0
    (1) 16
    (2) 01-30 : 4-120 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36
    seconds.
    Assign the access code for UCD Station Busy-
    Out Set and Reset.• Y = 0-3 (Numbering Plan Group 0-3)
    (1) X-XXX (Access Code)
    (2) 044: Busy-Out Set
    045: Busy-Out Reset
    Assign the UCD Busy-Out key on the 
    Multiline Terminal, if required.• YY = 00
    (1) Primary Extension No. +    + Key No. 
    (2) F0044: UCD Busy-Out
    Assign the Release key on the Multiline 
    Terminal, if required.• YY = 00
    (1) Primary Extension No. +   + Key No. 
    (2) F1020: Release 
    B
    A
    CM41
    CM20
    CM90
    CM17
    CM42
    ,
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 08
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    DESCRIPTION DATA
    Specify the processing for an incoming call 
    when all UCD Stations are busy.(1) 212 
    (2) 0/1 :Busy Tone Connection /Queuing
    Specify the processing for a held call after set-
    ting the UCD Busy-Out.(1) 214 (For the held Call from Tie Line)
    (2) 0/1 :Reconnected by Switch Hook 
    Flash/Disconnected 
    (1) 215 (For the held call from C.O. Line)
    (2) 0/1 :Reconnected by Switch Hook 
    Flash/Disconnected
    Specify that the transferred C.O. call from a 
    station or SN610 ATTCON is placed into 
    queuing mode when all UCD stations are 
    busy.
    Note:This data is only effective when
    CM08-212 is set to 1. (1) 227 
    (2) 0: The call is placed into queuing mode. 
    Note
    1 : Recall to the transferring station 
    (when the call is transferred from 
    station) or attendant Camp-On is 
    set (when the call is transferred 
    from ATTCON).
    Enable the UCD Busy-Out set and reset from 
    the secondary extension.
    (1200 Series Enhancement)(1) 442 
    (2) 0/1 : Available/Not Available
    B
    END
    CM08 
    						
    							ND-45670 (E) CHAPTER 2
    Page 409
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    To provide the delay announcement for UCD:
    DESCRIPTION DATA
    Assign a Digital Announcement Trunk Cir-
    cuit No. to each LEN No.(1) 0000-0511 (LEN No.)
    (2) EB000-EB127 (Digital Announcement 
    Trunk Circuit No.)
    Assign the Class of Service for Digital An-
    nouncement Trunk Access (Record/Replay/
    Delete) to the required station.• CM12 YY=02
    (1) X-XXXX: Station No.
    (2) XX
    XX
    *a 
    *a: Service Restriction Class (A)
    (00-15 )
    • CM15 YY=33
    (1) XX: Service Restriction Class (A) 
    assigned by CM12 YY=02
    (2) 1 : Allowed
    Specify the pattern of the message sent to 
    each UCD group.•Y = A
    (1) X-XXXX: Pilot Station number of the 
    UCD Group
    (2) 0: To be sent periodically
    1 : To be sent only once.
    If the data for CM17 Y = A is “0”, set the in-
    terval time for UCD Delay Announcement.•Y = 0
    (1) 47
    (2) 01-30 : 4-120 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36 sec-
    onds.
    Define the maximum waiting time of a UCD 
    Call for the UCD PEG Count. This timing is 
    also applied to the duration of Ringback 
    Tone after a call arrives before the first Delay 
    Announcement answers the call.•Y = 0
    (1) 16
    (2) 01-30 : 4-120 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36 sec-
    onds.
    Assign the UCD Delay Announcement func-
    tion to the required Digital Announcement 
    Trunk Circuit.• YY = 00
    (1) 000-127 (Digital Announcement Trunk 
    Circuit No.)
    (2) 0B0XX
    : UCD Delay Announcement
    11XX
    : UCD Second Delay Announcment
    *a: UCD Group No. (00-15)-
    START
    CM10
    CM17
    CM41
    CM49
    CM12
    CM15
    A
    *a
    *a 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 4 10
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    DESCRIPTION DATA
    Assign an access code to record, replay, and 
    delete the Digital Announcement Trunk.• Y=0-3 (Numbering Plan Group 0-3)
    (1) X-XXXX: Access code
    (2) A00: Record
    A01: Replay
    A02: Delete
    When transferring the call to an extension or 
    Attendant after the 1st interval time of UCD 
    Delay Announcement, assign the destination.
    Note:This command is only effective when
    CM17, Y=A is set to 0 (to be sent pe-
    riodically).•Y=17
    (1) 00-63: Tenant No.
    (2) Destination: 
    X-XXXX: Station No. or E000: SN610
    ATTCON
    Specify a diversion display on a transferred 
    destination (Multiline Terminal or SN610 AT-
    TCON).(1) 357
    (2) 0/1 : Available/Not Available
    CM20
    A
    END
    CM51
    CM08 
    						
    							ND-45670 (E) CHAPTER 2
    Page 411
    Revision 2.0
    UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
    To monitor a UCD call, with or without a Warning Tone:
    DESCRIPTION DATA
    Specify the warning tone sent to connected 
    parties (in two-way calling) when monitoring.(1) 259 
    (2) 0: No Tone
    1 : One Warning Tone 
    Assign the Class of Service for monitoring 
    stations. • CM12 YY = 02 
    (1) X-XXXX: Station number
    (2) XX
    XX
    *a: Service Restriction Class (A) (00-
    15 )
    • CM15 YYY = 103 
    (1) XX: [Service Restriction Class (A) 00-
    15] assigned by CM12 YY = 02 
    (2) 1 : Allowed
    Assign the Class of Service for monitored sta-
    tions. 
    Note:Monitoring telephone conversations
    may be illegal under certain circum-
    stances and laws. Consult a legal ad-
    visor before implementing the
    monitoring of telephone conversa-
    tions. Some federal and state laws re-
    quire a party monitoring a telephone
    conversation to use beep-tone(s), to
    notify all parties to the telephone
    conversation, and/or obtain consent
    from all parties to the telephone con-
    versation. Some of these laws pro-
    vide strict penalties for illegal
    monitoring of telephone conversa-
    tions.• CM12 YY = 02 
    (1) X-XXXX: Station number 
    (2) XX
    XX 
    *a: Service Restriction Class (A) (00-
    15 ) 
    • CM15 YYY = 104 
    (1) XX: [Service Restriction Class (A) 00-
    15] assigned by CM12 YY = 02
    (2) 1 : Allowed
    Assign the access code for monitoring, if re-
    quired. • Y = 0-3 (Number Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 033: Monitor
    Assign a monitoring function key to the re-
    quired multiline terminals. • YY = 00
    (1) X-XXX: (Primary Ext. No.) + + Key 
    No. (01-16) 
    (2) F0033: Monitor
    START
    CM08
    CM20
    CM90
    CM12
    CM15
    CM12
    CM15
    END
    *a
    *a
    , 
    						
    All NEC manuals Comments (0)