CHAPTER 2 ND-45670 (E) Pag e 4 02 Revision 2.0 TRUNK-TO-TRUNK CONNECTION DESCRIPTION DATA Assign the Service Restriction Class C to each station.• YY = 07 (1) X-XXXX:Primary Extension No. (2) XX:Service Restriction Class C (00-15) Provide the switch hook flash capability dur- ing C.O. line connection, to the required sta- tions.• YY = 90, 91 (1) 00-15:Service Restriction Class C (2) 1 :Allowed Specify the combination of trunk routes al- lowing the Trunk to Trunk Connection.(1) XX XX Incoming trunk route 00-63 Outgoing trunk route 00-63 (2) 0/1 : Allowed/Restricted Provide the system with Ring Transfer for Call Transfer-All Calls to a trunk when a sta- tion holds another station or trunk.(1) 253 (2) 0: Allowed Provide the system with forced disconnection when a tandem call duration passes a predeter- mined time.(1) 029 (2) 0/1 : Available/Not available Allow or restrict forced disconnection of tan- dem connection for the incoming trunk route. This data is available when CM08-029 is set to 0.• YYY = 119 (1) 00-63:Trunk route No. (2) 0/1 :Allowed/Restricted Specify the forced disconnection timing for tandem call.•Y = 0 (1) 54 (2) 01-06:64-224 min. (32 min. increments) If no data is set, the default setting is 128 min. CM12 A CM08 CM35 CM15 CM36 CM41 START
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 403 Revision 2.0 TRUNK-TO-TRUNK CONNECTION DESCRIPTION DATA Provide the system with Trunk to Trunk Con- nection when no release signal arrives from the incoming trunk route and answer signal ar- rives from the outgoing trunk route.(1) 324 (2) 0/1 :Available/Not available Provide the system with Trunk to Trunk Con- nection transferred by a station or an atten- dant, when no answer signal arrives and release signal arrives from the outgoing trunk route.(1) 028 (2) 0/1 :Available/Not available Specify the forced disconnection timing for tandem connection when the called party does not answer. This data is available when no release signal arrives from incoming trunk route.•Y = 0 (1) 55 (2) 01-13:12-60 sec. (4 sec. increments) If no data is set, the default setting is 20-24 sec. CM41 END CM08 A
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 04 Revision 2.0 TRUNK-TO-TRUNK CONNECTION To provide the AMP trunk for Trunk-to-Trunk Connection (1500 Series Enhancement): DESCRIPTION DATA Assign the Card Number of the AMP trunk (PN-2AMP). Maximum of two digits are available. Note:The AMP card number must be assigned to both of the first LEN (Level 0) and the third LEN (Level 2) of each slot.(1) LEN (0000-0511) (2) Card No. of AMP trunk C100-C115 : For PIM0/1 C116-C131 : For PIM2/3 C132-C147 : For PIM4/5 C148-C163 : For PIM6/7 Assign the AMP patterns to each combination of the trunk routes.• YY = 00 (1) XX XX Incoming trunk route 00-63 Outgoing trunk route 00-63 (2) 00-14:AMP pattern No. 00-14 15 : Not use the AMP trunk Assign the gain value of each AMP pattern. • YY = 01 (1) 00-14: AMP pattern No. 00-14 (2) X X Fixed gain 0 : 12 dB 1 : 8 dB 2 : 4 dB 3 : 0 dB AGC (Automatic Gain Control) 0 : 0 dBr 1:+4 dBr 2 : –4 dBr 3 : Through (assigned by Fixed Gain) Assign the Echo Canceller function to each AMP pattern.• YY = 02 (1) 00-14:AMP pattern No. 00-14 (2) 0:Through 1 : Normal Assign the Gain Controller of Echo Canceller to each AMP pattern.• YY = 03 (1) 00-14: AMP pattern No. 00-14 (2) 0 :ON 1:OFF CM10 A CM38 START
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 405 Revision 2.0 TRUNK-TO-TRUNK CONNECTION DESCRIPTION DATA Select the Tone Disabler’s mode on each AMP pattern.• YY=04 (1) 00-14: AMP pattern No. 00-14 (2) 0:G164 1 : G165 Specify the Detect Timing of Tone Disabler on each AMP pattern.• YY=05 (1) 00-14: AMP pattern No. 00-14 (2) 0:0 sec. 1 : 2 sec. Specify the channels connected to each AMP pattern.• YY=06 (1) 00-14: AMP pattern No. 00-14 (2) 0:Incoming route: Tie Line Outgoing route: C.O. Line 1 :Incoming route: C.O. Line Outgoing route: Tie Line Specify the Timing of AMP trunk connection on each AMP pattern.• YY=07 (1) 00-14: AMP pattern No. 00-14 (2) 0:When dialing is finished 1 :When answering CM38 C END
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 06 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW PROGRAMMING To activate UCD: DESCRIPTION DATA For each UCD Group, assign station numbers, one by one, in the order of hunting. Note:Up to 60 stations can be assigned into a single UCD group. Example: For setting Station Numbers 200, 201, 202 into one UCD Group. 1st Operation (1) 200 (2) 200 2nd Operation(1) 201 (2) 202 3rd Operation (1) 202 (2) 200•Y = 0 (1) X-XXXX (Station No.) (2) X-XXXX (Another Station No. to be linked) Assign the Pilot Station and Member Station. • Y = 1 (1) X-XXXX (UCD Station No.) (2) 1/0 : Pilot Station/Member Station Assign the UCD Group Number. • Y = 2 (1) X-XXXX (UCD Station No.) (2) 00-15 (UCD Group 00-15) Specify the UCD service for each type of call. • Y = 4 (Internal Call: from station/AT- TCON) (1) X-XXXX (Pilot Station No. of the UCD Group) (2) 0/1 : Not to be provided/To be provid- ed • Y = 5 (C.O. Incoming Call: DDD: FX/ WATS) (1) X-XXXX (Pilot Station No. of the UCD Group) (2) 0/1 : Not to be provided/To be provid- ed CM17 START A 3rd 1st 2nd 200 202 201
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 407 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW DESCRIPTION DATA • Y = 6 (Tie Line Incoming Call) (1) X-XXXX (Pilot Station No. of the UCD Group) (2) 0/1 : Not to be provided/To be provid- ed • Y = 7 (DID Call) (1) X-XXXX (Pilot Station No. of the UCD Group) (2) 0/1 :Not to be provided/To be provided • Y=B (Designation of the number of queuing in each UCD group) (1) X-XXXX (Pilot Station No. of the UCD Group) (2) 0/1 : To be provided (See CM42-16)/ Not to be provided Specify the maximum number of queuing in each UCD group.(1) 16 (2) 01-99 (Number of queuing in each UCD group) Specify the basic call answer delay time for use in PEG Count analysis.•Y = 0 (1) 16 (2) 01-30 : 4-120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 seconds. Assign the access code for UCD Station Busy- Out Set and Reset.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX (Access Code) (2) 044: Busy-Out Set 045: Busy-Out Reset Assign the UCD Busy-Out key on the Multiline Terminal, if required.• YY = 00 (1) Primary Extension No. + + Key No. (2) F0044: UCD Busy-Out Assign the Release key on the Multiline Terminal, if required.• YY = 00 (1) Primary Extension No. + + Key No. (2) F1020: Release B A CM41 CM20 CM90 CM17 CM42 , ,
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 08 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW DESCRIPTION DATA Specify the processing for an incoming call when all UCD Stations are busy.(1) 212 (2) 0/1 :Busy Tone Connection /Queuing Specify the processing for a held call after set- ting the UCD Busy-Out.(1) 214 (For the held Call from Tie Line) (2) 0/1 :Reconnected by Switch Hook Flash/Disconnected (1) 215 (For the held call from C.O. Line) (2) 0/1 :Reconnected by Switch Hook Flash/Disconnected Specify that the transferred C.O. call from a station or SN610 ATTCON is placed into queuing mode when all UCD stations are busy. Note:This data is only effective when CM08-212 is set to 1. (1) 227 (2) 0: The call is placed into queuing mode. Note 1 : Recall to the transferring station (when the call is transferred from station) or attendant Camp-On is set (when the call is transferred from ATTCON). Enable the UCD Busy-Out set and reset from the secondary extension. (1200 Series Enhancement)(1) 442 (2) 0/1 : Available/Not Available B END CM08
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 409 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW To provide the delay announcement for UCD: DESCRIPTION DATA Assign a Digital Announcement Trunk Cir- cuit No. to each LEN No.(1) 0000-0511 (LEN No.) (2) EB000-EB127 (Digital Announcement Trunk Circuit No.) Assign the Class of Service for Digital An- nouncement Trunk Access (Record/Replay/ Delete) to the required station.• CM12 YY=02 (1) X-XXXX: Station No. (2) XX XX *a *a: Service Restriction Class (A) (00-15 ) • CM15 YY=33 (1) XX: Service Restriction Class (A) assigned by CM12 YY=02 (2) 1 : Allowed Specify the pattern of the message sent to each UCD group.•Y = A (1) X-XXXX: Pilot Station number of the UCD Group (2) 0: To be sent periodically 1 : To be sent only once. If the data for CM17 Y = A is “0”, set the in- terval time for UCD Delay Announcement.•Y = 0 (1) 47 (2) 01-30 : 4-120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 sec- onds. Define the maximum waiting time of a UCD Call for the UCD PEG Count. This timing is also applied to the duration of Ringback Tone after a call arrives before the first Delay Announcement answers the call.•Y = 0 (1) 16 (2) 01-30 : 4-120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 sec- onds. Assign the UCD Delay Announcement func- tion to the required Digital Announcement Trunk Circuit.• YY = 00 (1) 000-127 (Digital Announcement Trunk Circuit No.) (2) 0B0XX : UCD Delay Announcement 11XX : UCD Second Delay Announcment *a: UCD Group No. (00-15)- START CM10 CM17 CM41 CM49 CM12 CM15 A *a *a
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 4 10 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW DESCRIPTION DATA Assign an access code to record, replay, and delete the Digital Announcement Trunk.• Y=0-3 (Numbering Plan Group 0-3) (1) X-XXXX: Access code (2) A00: Record A01: Replay A02: Delete When transferring the call to an extension or Attendant after the 1st interval time of UCD Delay Announcement, assign the destination. Note:This command is only effective when CM17, Y=A is set to 0 (to be sent pe- riodically).•Y=17 (1) 00-63: Tenant No. (2) Destination: X-XXXX: Station No. or E000: SN610 ATTCON Specify a diversion display on a transferred destination (Multiline Terminal or SN610 AT- TCON).(1) 357 (2) 0/1 : Available/Not Available CM20 A END CM51 CM08
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 411 Revision 2.0 UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW To monitor a UCD call, with or without a Warning Tone: DESCRIPTION DATA Specify the warning tone sent to connected parties (in two-way calling) when monitoring.(1) 259 (2) 0: No Tone 1 : One Warning Tone Assign the Class of Service for monitoring stations. • CM12 YY = 02 (1) X-XXXX: Station number (2) XX XX *a: Service Restriction Class (A) (00- 15 ) • CM15 YYY = 103 (1) XX: [Service Restriction Class (A) 00- 15] assigned by CM12 YY = 02 (2) 1 : Allowed Assign the Class of Service for monitored sta- tions. Note:Monitoring telephone conversations may be illegal under certain circum- stances and laws. Consult a legal ad- visor before implementing the monitoring of telephone conversa- tions. Some federal and state laws re- quire a party monitoring a telephone conversation to use beep-tone(s), to notify all parties to the telephone conversation, and/or obtain consent from all parties to the telephone con- versation. Some of these laws pro- vide strict penalties for illegal monitoring of telephone conversa- tions.• CM12 YY = 02 (1) X-XXXX: Station number (2) XX XX *a: Service Restriction Class (A) (00- 15 ) • CM15 YYY = 104 (1) XX: [Service Restriction Class (A) 00- 15] assigned by CM12 YY = 02 (2) 1 : Allowed Assign the access code for monitoring, if re- quired. • Y = 0-3 (Number Plan Group 0-3) (1) X-XXX: Access Code (2) 033: Monitor Assign a monitoring function key to the re- quired multiline terminals. • YY = 00 (1) X-XXX: (Primary Ext. No.) + + Key No. (01-16) (2) F0033: Monitor START CM08 CM20 CM90 CM12 CM15 CM12 CM15 END *a *a ,