CHAPTER 2 ND-45670 (E) Pag e 2 14 Revision 2.0 DUAL HOLD PROGRAMMING DESCRIPTION DATA Assign the Class of Service for this feature to the required station. • CM12 YY = 02 (1) X-XXXX: Station Number (2) XX XX *a: Service Restriction Class B (00- 15 ) • CM15 YY = 64 (1) XX Service Restriction Class B (00- 15) assigned by CM12 YY = 02. (2) 1 : Allowed CM12 START CM15 END *a
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 215 Revision 2.0 E & M TIE LINE ACCESS PROGRAMMING DESCRIPTION DATA Assign a Trunk Number for the PN-2ODT card to the required LENs. Note:The trunk number must be assigned to the first LEN (Level 0) and/or the second LEN (Level 1) of each LT slot. (1) LEN (0000-0511) (2) D000-D255 (Trunk No.) Assign a Trunk Route access code to each Tie Line Trunk route.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (81/82) (2) 100-163: Trunk Route 00-63 (01/02) Assign a Trunk Route and Tenant number to each Trunk.• YY = 00 (1) Trunk No. (000-255) (2) Trunk Route No. (00-63) (01/02) • YY = 01 (1) Trunk No. (000-255) (2) Tenant No. (00-63) (00/00) Assign Trunk Route data to the Trunk Route Number assigned by CM30 YY = 00. Note:Both circuit must be set to same pur- pose (2-wire or 4-wire) on one PN- 2ODT card.• YYY =105 (2-wire E & M/4-wire E & M Trunk) (1) Trunk Route No. (00-63) (2) 0 : 2-wire E & M Trunk 1 : 4-wire E & M Trunk • YYY = 104 (Polarity of E & M Trunk) (1) Trunk Route No. (00-63) (2) 1 : E wire (Open), M wire (Open) 2 : E wire (Ground), M wire (Battery) 3 : E wire (Ground), M wire (Ground) CM10 START A CM20 CM30 CM35
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 2 16 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Assign Trunk Route data to the Trunk Route Number assigned by CM30 YY = 00. • YY = 00 (Kind of Trunk Route) (1) Trunk Route No. (00-63) (01/02) (2) 04 (Tie Line) • YY = 01 (1) Trunk Route No. (00-63) (01/02) (2) < Incoming > < Outgoing > 2 : DP-10PPS DP 10PPS 4 : DTMF DTMF 7 : DTMF/DP DTMF • YY = 02 (IC/OG) (1) Trunk Route No. (00-63) (01/02) (2) 1 : Incoming Trunk 2 : Outgoing Trunk 3 : Bothway Trunk • YY = 04 (Answer Signal from Distant Office) (1) Trunk Route No. (00-63) (01/02) (2) 2/7 : Arrive/Not Arrive • YY = 05 (Release Signal from Distant Office) (1) Trunk Route No. (00-63) (01/02) (2) 1 : Arrive • YY = 08 (Sending of Dial Pulse) (1) Trunk Route No. (00-63) (01/02) (2) 3 : Send • YY = 09 (Incoming Connection Sig- nalling) (1) Trunk Route No. (00-63) (01/02) (2) 03: Wink Start 04: Delay Dial 05: Immediate Start 06: 2nd Dial Tone/Timing Start • YY = 10 (When YY = 09 is 06) (1) Trunk Route No. (00-63) (01/02) (2) 0/1 : No Tone/2nd Dial Tone CM35 B A
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 217 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA • YY = 13 (Maximum Number of Send- ing Digits) (1) Trunk Route No. (00-63) (2) 001-031: 1 -31 digits If no data is set, sender is released when time out occurs or the called station answers. Assign the appropriate data for the characteristic of the distant PBX.• YY = 20 (Sender Start Condition) (1) Trunk Route No. (00-63) (01/02) (2) 00: Wink Start 01: Delay Dial 15: Timing Start (As per YY = 21) The above data should be set to each route ac- cording to the data for YY = 09, as shown be- low. Data for YY = 09 Data for YY = 20 03 ®00 04 ®01 05® 15 06® 15 • YY = 21 (Sender Start Timing) (1) Trunk Route No. (00-63) (2) 00: 0 sec 08 : 6.0 sec 01: 0.5 sec 09 : 7.0 sec 02: 1.0 sec 10 : 8.0 sec 03: 1.5 sec 11 : 9.0 sec 04: 2.0 sec 12 : 10.0 sec 05: 2.5 sec 13 : 11.0 sec 06: 4.0 sec 14 : 12.0 sec 07: 5.0 sec 15 : 3.0 sec CM35 C B
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 2 18 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA When YY = 01 is 2, assign the data for the DP Sender Characteristics. • YY = 23 (DP Sender Inter Digital Pause) (1) Trunk Route No. (00-63) (2) 0 : 300 ms 1 : 400 ms 2 : 500 ms 3 : 600 ms 4 : 700 ms 5 : 900 ms 6 : 1100 ms 7 : 800 ms • YY = 25 (DP Sender Make Ratio) (1) Trunk Route No. (00-63) (2) 0/1 : 33% Make Ratio/39% Make Ratio • YY = 45 (DP Sender Release Timing) (1) Trunk Route No. (00-63) (2) 0 : 2 sec 1 : 4 sec 2 : 6 sec 3 : 8 sec 4 : 12 sec 5 : 14 sec 6 : 16 sec 7 : 10 sec When YY = 01 is 4, assign data for the DTMF Sender Characteristics.• YY = 24 (DTMF Sender Inter Digital Pause) (1) Trunk Route No. (00-63) (2) 0 : 32 ms 1 : 64 ms 2 : 80 ms 3 : 96 ms 4 : 160 ms 5 : 192 ms 6 : 240 ms 7 : 96 ms • YY = 26 (DTMF Sender Signal Width) (1) Trunk Route No. (00-63) (2) 0/1 : 64 ms/128 ms CM35 D C
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 219 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA • YY = 46 (DTMF Sender Release Tim- ing) (1) Trunk Route No. (00-63) (2) 0 : 2 sec 1: 4 sec 2: 6 sec 3: 8 sec 4 : 12 sec 5 : 14 sec 6 : 16 sec 7 : 10 sec Specify the desired Station Ringing Cadence and Multiline Terminal Tone Ringer. • YY = 33 (Ringing Cadence) (1) Trunk Route No. (00-63) (2) 2 : 1 sec ON, 2 sec OFF 3 : 2 sec ON, 4 sec OFF To make this data assignment effective enter the data “1” for CM08-180 • YY = 34 (Multiline Terminal Tone Ringer) (1) Trunk Route No. (00-63) (2) 0 : 1024+1285´16 (Hz) 1 : 480+606´8 (Hz) 2 : 600+700 (Hz) 3 : 480+606´16 (Hz) CM35 E D
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 2 20 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Specify the value of the Tie Line Pad of PN-2ODT. • YY = 19 (1) Trunk Route No. (00-63) (2) 0 1 2 3 4 5 6 7 When using the programmable PAD (CM35 YY = 19, 2nd data = 0-3), assign the PAD data. (1) 50-65 (See the following Table) (2) 00-15 (See the following Table) CM35 F E CM42 T/R : Transmit/Receive CONNECTION PATTERNS (A-B)PAD DATA OF B TRUNK D ATA = 4 ( T / R ) D ATA = 5 ( T / R ) D ATA = 6 ( T / R ) D ATA = 7 ( T / R ) Station-ODT3/3 3/3 Tone-ODT 0/0 0/0 COT-ODT 2/2 0/0 ODT-ODT 0/0 0/0 DTI-ODT 0/0 0/0 Programmable PAD (See CM42) Fixed PAD (See the follow- ing Table) PATTERN 1ST DATA (1)PAD DATA PATTERNS CONNECTING PATTERNS (A-B) CM35 YY=19 2ND DATA=0CM35 YY=19 2ND DATA=0CM35 YY=19 2ND DATA=0CM35 YY=19 2ND DATA=0 50 | 6550 54 58 62 STA-ODT 51 55 59 63 TONE-ODT 52 56 60 64 COT-ODT 53 57 61 65 ODT/DTI-ODT
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 221 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Specify the restriction of incoming call termination to different Tenants.• Y = 2 (1) XX XX *a: Tenant No. of called station *b: Tenant No. of Trunk Route (2) 0/1 : Restricted/Allowed Provide DTMF Receivers for Tie Line incoming calls, if required.• Y = 1 (1) XX X *a: Card No. (00-15) assigned by CM10 (E200-E215) *b: Circuit No. (0-3) (2) 0 : Only for Tie Line CM42 F END CM63 CM45 T/R : Transmit/Receive PATTERN 2ND DATA (2)PAD DATA OF B TRUNK (T/R) [dB] REMARKS ODT 00 | 1500 0/0 01 0/0 02 0/0 03 2/2 04 3/3 05 12/11 06 16/11 07 6/6 08 | 15Not Used *b *a *b *a
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 2 22 Revision 2.0 ENHANCED 911 PROGRAMMING DESCRIPTION DATA Assign a slot number to 911 Sender trunk. The slot number is given by the SENSE switch on the 911 Sender trunk. Assign 911 Sender trunk number to each 911 Sender trunk.(1) Slot No. (04-15) (2) 19 (PN-ME00 card) • YY=04 (1) XX: 911 Sender trunk No. (00-15) (2) XX X Provide the system with Enhanced 911. (3) 474 (Enhanced 911) (4) 0: Provided Specify whether the Sender Tone will be sent when a call originated, or not. Provide the System with Enhanced 911. Specify that all circuits on the 911 Sender trunk are used as sender. Note:The AP Number 0-3 correspond to the Slot Numbers assigned by CM05 (00-15) as shown below: AP Number 0: Slot Number X AP Number 1: Slot Number Y AP Number 2: Slot Number Z AP Number 3: Slot Number W (X
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 223 Revision 2.0 ENHANCED 911 DESCRIPTION DATA Set the trunk route that no answer signal arrives from the distant office for outgoing connection.• YY=04 (Answer Signal from distant of- fice. (1) Trunk Route No. (00-63 (2) 3: No Answer signal (Polarity Reversal is ignored) Specify incoming connection signaling. Note:PN-24DTA must be set to Wink Start. PN-20DT and AN-4COT must be set to Ring Down. Enhanced 911 will not function if PN-20DT is set to Wink Start.• YY=09 (Incoming connection signal- ing) (1) Trunk Route No. (00-63) (2) 03: Wink Start 15: Ring Down Provide SMDR/Centralized Billing for outgoing.• YY=14 (SMDR for outgoing call) (1) Trunk Route No. (00-63) (2) 1 : Provided (3) Specify sender start condition to Wink Start. Note:Digital and Analog Tie Lines are set to Wink Start. Analog Loop Start Lines are set to Timing Start.• YY=20 (Sender start condition) (1) Trunk Route No. (00-63) (2) 00: Wink Start 15: Timing Start Specify the trunk seizure pattern. • YY=36 (Trunk seizure pattern) (1) Trunk Route No. (00-63) 0: After dialing maximum number of digits Provide the trunk route with Enhanced 911. • YY=38 (Enhanced 911) (1) Trunk Route No. (00-63) (2) 3: Enhanced 911 Specify the sending method of calling number to the 911 Sender trunk.• YYY=129 (Sending method of calling number) (1) Trunk Route No. (00-63) (2) 3: Enhanced 911 Assign the Area Code Development Pattern number for maximum digit analysis.• YY=76 (Area Code Development Pat- tern) (1) Trunk Route No. (00-63) 00-07: Area Code Development Pattern No. 0-7 Define the maximum number of digits which can be sent to the network.• Y=0-7 (Area Code Development Pat- tern No. 0-7) (1) X-XXX... : Area Code/Office Code or its part (Max. 8 digits) (2) 01-79: 1-79 digits Assign the access code for LCR Group 0-3. • Y=0-3 (Numbering Group No. 0-3) (1) X-XXXX: Access Code (Max. 4 digits) (1) A26-A28: Access Code for LCR Group 0-3 CM35 CM85 B A CM20