    							CHAPTER 2 ND-45670 (E)
    Pag e 1 84
    Revision 2.0
    CUSTOMER ADMINISTRATION TERMINAL (CAT)
    PROGRAMMING
    DESCRIPTION DATA
    Assign the class of service for CAT to the 
    required Multiline Terminals.• CM12 YY = 02 
    (1) X-XXXX (Primary Extension No.)
    (2) XX XX
     
    *a: Service Restriction Class (B) 
    (00-15 )
    • CM15 YY = 56 
    (1) XX: [Service Restriction Class (B) 
    (00-15)] assigned by CM12 YY 
    = 02.
    (2) 1  Allowed
    Specify the command codes accessible to 
    each Password Level.• YY = 00: Password Level 0-6
    • YY = 01: Password Level 1-6
    • YY = 02: Password Level 2-6
    • YY = 03: Password Level 3-6
    • YY = 04: Password Level 4-6
    • YY = 05: Password Level 5-6
    • YY = 06: Password Level 6
    • YY = 10: Password Level 0
    • YY = 11: Password Level 1
    • YY = 12: Password Level 2
    • YY = 13: Password Level 3
    • YY = 14: Password Level 4
    • YY = 15: Password Level 5
    • YY = 16: Password Level 6
    (1) XX
    *a: 00-FF (Command Codes exclu-
    sive of 03, E7, E9) 
    (2) 0/1  Allowed/Restricted 
    A
    CM12
    CM15
    CME7 START
    *a
    *a 
    						
    							ND-45670 (E) CHAPTER 2
    Page 185
    Revision 2.0
    CUSTOMER ADMINISTRATION TERMINAL (CAT)
    Note 1:If the system data all clear or system data partial clear is required before programming from a CAT, per-
    form the following operations:
    1. Plug the PN-2DLCB/4DLCA card into LT00 Slot of PIM0 
    2. Connect the CAT to LEN0000 at the MDF
    3. Set SW3 on the MP card to “B”
    4. Press SW1 (RESET Switch) on the MP card (System Data All Clear/Partial Clear)
    5. Set SW3 to “0” and press SW1.
    6. Set the Multiline Terminal to CAT mode (Station Number 300 is automatically assigned to the Multi-
    line Terminal). 
    Note 2:If Password Service is activated, enter the predetermined password by CM03 before programming from a
    CAT. 
     + 03 +   + Password Level No. (0-7)+   +Password+  
    - “OK” will be displayed, if accepted.
    - “DATA ERROR” will be displayed if the password is incorrect.
    DESCRIPTION DATA
    Enable the system to change the password.  (1) 8 
    (2) 0
    : Allowed
    Assign a password to each Password Level.  (1) 0-7 (Password Level 0-7)
    (2) X-X...X (Max. 8 digits Password Code)
    A password code for Password Level 7
    must be assigned prior to providing the
    password service by Function No. 9 of
    CME9. 
    The following passwords are not available.
    “CCCCCCCC”
    “FFFFFFFF”
    Provide the system with Password service. 
    After setting this data, access to system 
    programming will be available with 
    password entry only.(1) 9 
    (2) 0: Provided 
    END
    A
    CME9
    STDEDEEXE 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 86
    Revision 2.0
    DATA LINE SECURITY
    PROGRAMMING
    DESCRIPTION DATA
    Assign the function of Analog Data Station 
    (Single-Line Station with FAX or MODEM) 
    to the required stations.• YY = 07
    (1) X-XXXX (Station No.)
    (2) 0: Data Station 
    END
    CM13 START 
    						
    							ND-45670 (E) CHAPTER 2
    Page 187
    Revision 2.0
    DELAYED RINGING
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Delayed Ringing feature to each 
    line key on a Multiline Terminal.
    Note:The Delayed Ringing feature can be
    assigned to the first 16 line/trunk
    keys (Key 01-16). • YY = 03
    (1) Primary Extension No. +     + Key No.
    Note
    (2) 0: Delayed Ringing 
    Specify the timing for Delayed Ringing.  • Y = 1
    (1) 09
    (2) 01-20: 2-40 sec. in 2 sec. increments
    If no data is set, the default setting is 10
    seconds.
    END
    CM90 START
    CM41, 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 88
    Revision 2.0
    DIAGNOSTICS
    PROGRAMMING
    Refer to the Maintenance Manual. 
    						
    							ND-45670 (E) CHAPTER 2
    Page 189
    Revision 2.0
    DIAL CONVERSION
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Card Number of the DTMF 
    Receiver to the required LENs.
    Note:When using the internal DTMF Re-
    ceiver on the PN-CP03 card, assign
    the Card No. E200 to LEN No.
    0124.(1) LEN (0000-0511)
    (2) Card No. of DTMF Receiver
    E200-E203: For PIM0/1 
    E204-E207: For PIM2/3 
    E208-E211: For PIM4/5 
    E212-E215: For PIM6/7 
    Assign the type of telephone set (DTMF) to 
    DTMF Stations. This data assignment is not 
    required for Multiline Terminal stations. • YY = 00
    (1) X-XXXX (Station No.)
    (2) 3: DTMF Telephone set 
    Assign DTMF Receivers for use with DTMF 
    Stations. • Y = 0 (Make Busy)
    (1) XX
     X 
    Card No. 00-15 assigned by 
    CM10 (E200-E215)
    Circuit No. 0-3
    (1) 1: Make Busy Cancel 
    • Y = 1 (PBR for incoming call from Tie 
    Line/DID)
    (1) XXX (Ditto to Y = 0)
    (2) 1:For both DTMF station and Tie 
    Line/DID
    A
    CM10
    CM12
    CM45 START
    INITIAL 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 90
    Revision 2.0
    DIAL CONVERSION
    DESCRIPTION DATA
    For a DP trunk, assign the type of signaling 
    for Outgoing and Bothway trunk routes to 
    DP. 
    Specify the DP Sender characteristics to 
    match the Central Office.• YY = 01
    (1) Trunk Route No. (00-63) 
    (2) 2 
    • YY = 23 (DP Sender Inter Digital 
    Pause) 
    (1) Trunk Route No. (00-63) 
    (2) 0: 300 ms 
    1: 400 ms 
    2: 500 ms 
    3: 600 ms 
    4: 700 ms 
    5: 900 ms 
    6: 1100 ms 
    7: 800 ms 
    • YY = 25 (DP Sender Make Ratio) 
    (1) Trunk Route No. (00-63) 
    (2) 0/1: 33%/39%
    • YY = 45 (DP Sender Release Timing) 
    (1) Trunk Route No. (00-63)
    (2) 0: 2 sec. 
    1: 4 sec. 
    2: 6 sec. 
    3: 8 sec. 
    4: 12 sec. 
    5: 14 sec. 
    6: 16 sec. 
    7: 10 sec. 
    For a DTMF trunk, assign the type of 
    signaling for Outgoing and Bothway Trunk 
    Routes to DTMF. • YY = 01
    (1) Trunk Route No. (00-63) 
    (2) 7
    B
    A
    CM35 
    						
    							ND-45670 (E) CHAPTER 2
    Page 191
    Revision 2.0
    DIAL CONVERSION
    HARDWARE REQUIRED 
    DTMF Receiver (PN-8RST) ´ n 
    n: Depends on the number of DTMF stations and the traffic condition of the system.
    DESCRIPTION DATA
    Specify the DTMF Sender characteristics to 
    match the Central Office.• YY = 24 (DTMF Inter Digital Pause) 
    (1) Trunk Route No. (00-63)
    (2) 0: 32 ms 
    1: 64 ms 
    2: 80 ms 
    3: 96 ms 
    4: 160 ms 
    5: 192 ms 
    6: 240 ms 
    7: 128 ms
    • YY = 26 (DTMF Sender Signal Width) 
    (1) Trunk Route No. (00-63)
    (2) 0/1: 64 ms/128 ms 
    • YY = 46 (DTMF Sender Release Tim-
    ing) 
    (1) Trunk Route No. (00-63) 
    (2) 0: 2 sec. 
    1: 4 sec. 
    2: 6 sec. 
    3: 8 sec. 
    4: 12 sec. 
    5: 14 sec. 
    6: 16 sec. 
    7: 10 sec. 
    Assign whether “*” or “#” from a DTMF 
    Telephone is used as a Switch Hook Flash 
    while hearing Busy Tone. (1) 050 (* is used as Switch Hook Flash) 
    (2) 0: Effective
    (1) 051 (# is used as Switch Hook Flash) 
    (2) 0: Effective
    END
    B
    CM08 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 1 92
    Revision 2.0
    DIRECT DIGITAL INTERFACE
    PROGRAMMING
    Refer to the DDI System Manual. 
    HARDWARE REQUIRED 
    Refer to the DDI System Manual.  
    						
    							ND-45670 (E) CHAPTER 2
    Page 193
    Revision 2.0
    DIRECT INWARD DIALING (DID)
    PROGRAMMING
    DESCRIPTION DATA
    Assign the ring rate on a DID call.  (1) 180
    (2) 0/1: 0.2 sec. ON, 0.2 sec. OFF, 0.2 
    sec. ON, 0.2 sec. OFF, 0.2 sec. 
    ON, 0.2 sec. OFF/As per the data 
    of CM35 YY = 33
    Assign the Trunk Numbers to the required 
    LENs.(1) LEN (0000-0511) 
    (2) Trunk No. (D000-D255)
    Assign the data for DID to the Trunk 
    Numbers assigned by CM10.• YY = 00 (Trunk Route Allocation)
    (1) Trunk No. (000-255)
    (2) Trunk Route No. (00-63) (03) 
    • YY = 01 (Tenant Allocation)
    (1) Trunk No. (000-255)
    (2) Tenant No. (00-63) (00)
    • YY = 02 (Terminating System in Day 
    Mode) 
    • YY = 03 (Terminating System in Night 
    Mode) 
    (1) Trunk No. (000-255)
    (2) 31CM08
    CM10
    CM30 START
    A 
    						