    							CHAPTER 2 ND-45670 (E)
    Pag e 3 10
    Revision 2.0
    MUSIC ON HOLD
    To provide External Hold Tone Source through PN-TNT Card (1200 Series Enhancement):
    To provide External Hold Tone Source through PN-CP03 Card (1500 Series Enhancement):
    DESCRIPTION DATA
    Assign the TNT Circuit No. (External Hold 
    Tone Source No. ) to the required LEN.(1) LEN (0000-0511)
    (2) DA00-DA09: TNT Circuit No.
    Note
    Note:
    The TNT Circuit No. must be as-
    signed to the first LEN (Level 0)
    and/or the third LEN (Level 2) of
    each LT slot.
    The TNT Circuit No. must be as-
    signed for each tenant (One Exter-
    nal Hold Tone Source can be
    provided for each tenant).
    Define the type of call to be provided with 
    External Hold Tone.•Y=0
    (1) 00: C.O. Line Call 
    01: Tie Line Call
    02: Internal Call
    (1) 0200: External Hold Tone Source
    Specify External Hold Tone Source per each 
    tenant.•Y=1
    (1) Tenant No. (00-63)
    (2) 00-09: External Hold Tone Source No.
    (TNT Circuit No. DA00-DA09)
    Specify which tenant External Hold Tone is 
    sent from.(1) 388
    (2) 0: Tenant of held station/trunk
    1
     : Tenant of holding station 
    DESCRIPTION DATA
    Define the type of call to be provided with 
    Hold Tone.•Y=0
    (1) 00:  C.O. Line Call
    01:  Tie Line Call
    02:  Internal Call
    (1) 1400: Hold Tone Source through MP 
    card
    START
    END
    CM10
    CM48
    CM64
    CM08
    CM48
    END
    START 
    						
    							ND-45670 (E) CHAPTER 2
    Page 311
    Revision 2.0
    MUSIC ON HOLD
    HARDWARE REQUIRED
    To provide External Hold Tone Source through PN-4COT and PN-DK00 card:
    •PN-4COT
    • PN-DK00
    • External Hold Tone Source provided locally
    Make the following connections between the trunks and the External Hold Tone Source at the MDF.
    For details, refer to the MDF cross connection for an External Tone Source in the INSTALLATION PROCEDURE
    MANUAL.
    To provide the Hold Message by Digital Announcement Trunk:
    • P N - 2 D ATA
    PN-DK00 CARD PN-4COT CARDPBX
    EXTERNAL HOLD TONE SOURCE
    MDF 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 12
    Revision 2.0
    MUSIC ON HOLD
    To provide the External Hold Tone Source through PN-TNT card:
    •PN-TNT
    • External Music Source provided locally
    To connect the External Hold Tone Source, plug the cable into JACK0 or JACK1 on the PN-TNT card.
    Set the switches on the PN-TNT card to adjust the External Hold Tone Source level.
    • Level Control of External Hold Tone Source through JACK0/JACK1
    No. 0 CIRCUIT (JACK0) No. 1 CIRCUIT (JACK1)
    OUTPUT LEVEL SW-1 SW-2 OUTPUT LEVEL SW-3
    SW-4
    -10 dB OFF OFF -10 dB OFF OFF
    -7 dB ON OFF -7 dB ON OFF
    -4 dB OFF ON -4 dB OFF ON
    -1 dB ON ON -1 dB ON ON
    JACK0 or JACK1PN-TNT CARDPBX
    EXTERNAL HOLD TONE SOURCE
    SW SW
    PN-TNT CARDON
    12 34 
    						
    							ND-45670 (E) CHAPTER 2
    Page 313
    Revision 2.0
    MUSIC ON HOLD
    To provide External Hold Tone Source through PN-CP03 card:
    • External Hold Tone Source provided locally.
    To connect the External Hold Tone Source, plug the cable into JACK on the PN-CP03 card.
    Set the switches on the PN-CP03 card as follows.
    To provide Hold Tone Source on the MP card:  Set the JP1 switch to UP.
    JAC K PN-CP03 CARDPBX
    EXTERNAL HOLD TONE SOURCE
    JP1
    PN-CP03 CARD
    VR
    JP1:INTERNAL/EXTERNAL 
    HOLD TONE
     SOURCE
    VR:VARIABLE RESISTOR FOR 
    EXTERNAL HOLD TONE SOURCE
    (0-20k
    W : CLOCKWISE)
    20
    0
    DOWN:EXTERNAL HOLD 
    TONE SOURCE
    UP:INTERNAL HOLD TONE 
    SOURCE
    :  POSITION TO BE SET 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 14
    Revision 2.0
    NIGHT SERVICE: ATTENDANT NIGHT TRANSFER
    PROGRAMMING 
    DESCRIPTION DATA
    Provide the system with Attendant Night 
    Transfer. (1)  018: Attendant Night Transfer 
    (2)  1 : To be provided 
    Assign the Night Connection Station to each 
    ATTCON Group. •  YY = 13
    (1) ATTCON Group 0-3 (00-03) assigned 
    by CM60 YY = 00 
    (2) X-XXXX: Night Connection Station 
    No.CM08 START
    END
    CM51 
    						
    							ND-45670 (E) CHAPTER 2
    Page 315
    Revision 2.0
    NIGHT SERVICE: CALL REROUTING
    PROGRAMMING 
    Refer to Night Connection-Fixed/Flexible, Trunk Answer Any Station, Direct Inward Termination (DIT), Direct In-
    ward Dialing (DID), and E&M Tie Line Access.  
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 16
    Revision 2.0
    NIGHT SERVICE: DAY/NIGHT MODE CHANGE BY ATTENDANT CONSOLE
    PROGRAMMING
    Note:The following trunk data (CM30) can be changed by this feature (depending upon programming).
    Day (YY)
    Night (YY)
    02 03
    04 05
    13 14
    15 16
    30 31
    DESCRIPTION DATA
    Assign the password code for Day/Night 
    Change by SN610 ATTCON.•  YY = 30
    (1) 1 
    (2)  XX-XX: Password Code (Max. 8 dig-
    its)
    X: 0-9, A(*), B(#)
    If no data is set, the default setting is
    NONE. In this case, the password is set
    to “12345678.”
    Assign the Day/Night mode key on SN610 
    ATTCON.•  YY = 00
    (1)  ATTCON No. +   + key No.
    (2) F6110 
    Assign the access code for providing Day/
    Night Mode change from a SN610 
    ATTCON, if required.•  Y = 0-3 (Numbering Plan Group 0-3) 
    (1) X-XXX (Access Code) 
    (2) A55 CM60 START
    CM20
    END
    CM90
    INITIAL
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 317
    Revision 2.0
    NIGHT SERVICE: DAY/NIGHT MODE CHANGE BY STATION DIALING
    PROGRAMMING 
    Note:The following trunk data (CM30) can be changed by this feature (depending upon programming).
    Day (YY)
    Night (YY)
    02 03
    04 05
    13 14
    15 16
    30 31
    DESCRIPTION DATA
    Provide the system with Day/Night Mode 
    change by Station Dialing. (1)  244:  Change of Terminating System 
    Incoming Trunk (CM30, YY = 
    02/03) 
    (2) 0: Available
    (1)  245:  Change Trunk Restriction Class 
    (CM30 YY = 02/03) 
    (2) 0: Available 
    Assign Service Restriction B to each station.  •  YY = 02
    (1) X-XXXX (Station No.) 
    (2) XX XX
    *a: Service Restriction Class B (00-
    15 ) 
    Assign the Day/Night Mode Change by 
    Station Dialing to Service Restriction B 
    assigned by CM12 YY = 02. •  YY = 60
    (1)  Service Restriction Class B (00-15) as-
    signed by CM12 YY = 02
    (2) 1 : Allowed
    Assign the access code for Day/Night Mode 
    change by Station Dialing.•  Y = 0-3 (Numbering Plan Group 0-3) 
    (1)  X-XXX: Access Code (68) 
    (2)  043:  Day/Night Mode Change by Sta-
    tion Dialing 
    Assign the Day/Night Mode Change by 
    Station Dialing key on the Multiline 
    Terminals. •  YY = 00
    (1)  X-XXXX: Primary Extension No. +   
    + Key No. 
    (2)  F0043: Day/Night Mode Change by 
    Station Dialing
    CM08 START
    CM12
    CM15
    CM90
    CM20
    END
    *a
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 18
    Revision 2.0
    NIGHT SERVICE: NIGHT CONNECTION-FIXED
    PROGRAMMING
    To Provide Night Connection Stations.
    DESCRIPTION DATA
    Assign a Night Connection Station to each 
    Incoming Trunk.•  YY = 03
    (1) Trunk No. (000-255) 
    (2)  04: Direct-In Termination
    •  YY = 05
    (1) Trunk No. (000-255) 
    (2)  X-XXXX: Night Connection Station 
    No.
    Assign the destination to which a call is 
    forwarded when the Night Connection 
    Station is Busy/No Answer.•  YY = 14 (When Night Connection 
    Station is busy.) 
    (1) Trunk No. (000-255) 
    (2)  01: To TAS
    04: To SN610 ATTCON 
    06: Automatic Camp-On 
    15 : Keep the call ringing (Waiting 
    until the Night Connection 
    Station becomes idle.)
    •  YY = 16 (When Night Connection 
    Station is not answering) 
    (1) Trunk No. (000-255) 
    (2)  01: To SN610 ATTCON 
    03: To TAS
    15 : Keep the call ringing (Waiting 
    until the Night Connection 
    Station becomes idle.)
    Specify the timing for a call forwarding when 
    the Night Connection Station is No Answer.
    Note:This timing is also applied to Call
    Forwarding-No Answer, Attendant
    Overflow, and Group Diversion.• Y = 0 
    (1) 01 
    (2)  01-30 : 4-120 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36
    seconds.
    CM30 START
    END
    CM41 
    						
    							ND-45670 (E) CHAPTER 2
    Page 319
    Revision 2.0
    NIGHT SERVICE: NIGHT CONNECTION-FLEXIBLE
    PROGRAMMING 
    Refer to Night Connection-Fixed and Call Forwarding-All Calls. 
    						