CHAPTER 2 ND-45670 (E) Page 74 Addendum-002 Revision 2.2 JANUARY, 1999 ATTENDANT CONSOLE (SN716 DESKCON) DESCRIPTION DATA Specify the type of the Attendant Console. • YY=22 (1) ATTCON No. (0-7) (2) 0 : SN716 DESKCON 1 : SN610 ATTCON Allocate the ATT Group No. to each SN716 DESKCON.• YY=00 (1) ATTCON No. (0-7) (2) 0: ATT GROUP 0 3: ATT GROUP 3 Specify the Master SN716 DESKCON within the ATT Group assigned by YY=00. • YY=01 (1) ATTCON No. (0-7) (2) 0/1 : Master/Sub When providing 2nd Ringing feature on the SN716 DESKCON, make Off-Hook Ringing effective.• YY=16 (1) ATTCON No. (0-7) (2) 0: To be provided Specify the tenants to be handled by each ATT Group.• Y=0-3 (1) Tenant No. (00-63) (2) 0/1 : To be handled/Not to be handledCM60 CM62 B END INITIAL || INITIAL INITIAL
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 75 Revision 2.0 ATTENDANT DELAY ANNOUNCEMENT PROGRAMMING DESCRIPTION DATA Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot. (1) LEN (0000-0511) (2) EB000-EB127: Digital Announcement Trunk Circuit No. For PIM0/1: EB000-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 Provide the Announcement Service via Digital Announcement Trunk on Attendant Delay Announcement.• YY = 74 (1) Trunk Route No. (00-63) (2) 0/1 : Allowed/Restricted Assign the function of the Digital Announcement Trunk Circuit.• YY = 00 (1) 000-127: Digital Announcement Trunk Circuit No. assigned by CM10 (EB000- EB127) (2) 0F XX: *a: Attendant Delay Announcement *b: Message No. (00-63) • YY = 0A (1) XX: Tenant No. (2) XX: Message No. (00-63) assigned by CM49 YY = 00 CM10 START CM35 CM49 A *b *a
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 7 6 Revision 2.0 ATTENDANT DELAY ANNOUNCEMENT DESCRIPTION DATA Specify the replaying of the message recorded in the Digital Announcement Trunk.(1) 165 (2) 0 : The message is replayed at an in- terval assigned by CM41 Y= 0, Function No. 47. 1 : The message is played only once. To record, replay, and delete a message, assign the Digital Announcement Trunk access codes, respectively. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) A00: Record A01: Replay A02: Delete Specify the unanswered timing of message replay.•Y = 0 (1) 16 (2) 01-30 : 4 sec-120 sec. in 4-sec. incre- ments If no data is set, the default setting is 32-36 seconds. Specify the interval time of message replay. • Y = 0 (1) 47 (2) 01-30 : 4 sec.-120 sec. in 4-sec. incre- ments If no data is set, the default setting is 32-36 seconds.CM08 A CM20 CM41 END
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 77 Revision 2.0 ATTENDANT OVERFLOW PROGRAMMING Note:Refer to the Automated Attendant feature programming section in this manual for assignment information of the Automated Attendant when using the Automated Attendant as the Attendant Overflow destination. DESCRIPTION DATA Provide the system with ATTENDANT OVERFLOW.(1) 067 (2) 0: Available Assign the data for terminating system in Day/ Night Mode for each trunk.• YY = 02 (Day Mode) (1) Trunk No. (000-255) (2) 14: Termination to SN610 ATTCON • YY = 03 (Night Mode) (1) Trunk No. (2) 04: DIT 09: Automated Attendant Note • YY = 05 (Night Station Assignment) (1) Trunk No. (2) X–XXXX (Station No.) Specify the Timing Interval for ATTENDANT OVERFLOW.•Y = 0 (1) 01: (2) 01-30 : 4-120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 seconds. CM08 START CM30 CM41 END
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 7 8 Revision 2.0 ATTENDANT OVERRIDE PROGRAMMING DESCRIPTION DATA Provide the system with ATTENDANT OVERRIDE.(1) 012 (2) 1 : Available Specify the interval of the Warning Tone sent to the connected parties.(1) 045 (2) 0 : Only Once 1 : Every 4 sec. Specify whether the Warning Tone is sent to the outside party.(1) 076 (2) 0 : To be sent out. 1 : Not to be sent out. Assign Service Restriction Class (A) to each station.• YY = 02 (1) X-XXXX (Station No.) (2) XX XX *a: Service Restriction Class (A) (00- 15 ) Assign this feature to the Service Restriction Class (A) assigned by CM12 YY= 02.• YY = 09 (1) XX:Service Restriction Class (A) as- signed by CM12 YY = 02. (2) 1 : Allowed Assign the access code for Individual Trunk Access.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX : Access Code (2) 081 : Individual Trunk Access Assign the Trunk Identification Code to each trunk. Note:By loading the Resident System Program, Trunk Identification Codes are assigned as follows: 1XXX *a: Trunk Number (000-255)• YY = 19 (1) Trunk No. (000-255) (2) XXXX: Trunk ID Code CM08 START CM12 CM15 CM20 CM30 A *a *a
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 79 Revision 2.0 ATTENDANT OVERRIDE Note:This feature cannot be used in conjunction with Attendant Lockout. DESCRIPTION DATA Assign the BV key to SN610 Attendant Console. Note:By Resident System Program, one of the Multi-Function keys is assigned as a BV key (when receiving Busy Tone).• YY = 00 (1) ATTCON No. + + Key No. (2) F6107: Busy Verification CM90 END A ,
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 8 0 Revision 2.0 AUTHORIZATION CODE PROGRAMMING 1. In a system with an Application Processor (PN-AP01) DESCRIPTION DATA Assign a slot number to the PN-AP01 card according to the location of the card. Note:The slot number is given by the SENSE switch on the PN-AP01 card.(1) Slot Number (04-15) (2) 07: PN-AP01 card Designate the AP card for this feature.(1) 216: Designates the Processor for the Authorization Code. (2) 1 : AP (PN-AP01) Specify whether Service Set Tone should be sent after dialing the access code for the Authorization Code.(1) 362: Provision of Service Set Tone after dialing the access code. (2) 1 : Not to be provided/To be provided. Assign the Class of Service for Authorization Code defined.• CM12 YY = 02 (1) X-XXXX: Station No. (2) XX XX *a: Service Restriction Class (A): 00-15 *b: Service Restriction Class (B): 00-15 • CM15 YY = 31 (Authorization Code) (1) Service Restriction Class (A) (00-15) Assigned by CM12 YY = 02 (2) 1 : Allowed CM05 START CM08 A CM12 CM15 INITIAL *b *a
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 81 Revision 2.0 AUTHORIZATION CODE DESCRIPTION DATA Assign the access code for each Authorization Code.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) 086: Authorization Code Specify the maximum number of digits for each Authorization Code.(1) 11: Authorization Code Max. digits (2) Max. number of digits (01-10 ). If Check Code is provided, the maximum number of digits is limited to eight (8). Note:CMD6 must be completed prior to programming CMD5. Set the SENSE1 switch on the DN-AP01 Board, as shown below. Load the initial data into the PN-AP01 by performing the following: + D60 + + 0000 + + CCC + After about 30 seconds the AP initialization is completed an the “RUN” lamp on the PN- AP01 lights. Set the SENSE1 switch on the PN-AP01 board, as shown below. CM20 B A CM42 CMD6 4 3 2 1: Switch position ONSENSE1 ST DEDEEXE 4 3 2 1: Switch position ONSENSE1
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 8 2 Revision 2.0 AUTHORIZATION CODE DESCRIPTION DATA Specify the conditions for adding a Check Code to each Authorization Code. A Check Code consists of 2 digits: The 1st and 2nd Check Code are generated by the AP according to the conditions specified by Y = 0 and Y = 1. Authorization Code: X 1 X2 X3 X4 X5 X6 X7 X8 C1 C2 • Y = 0 (Designation of Significant digits for Check Code generation) (1) 0: For 1st Check Code 1: For 2nd Check Code (2) 00 X X: Significant digit designation *a: 1st-4th digit (0-F) (See left column) *b: 5th-8th digit (0-F) If no Check Code is required, set data = 0000 for both 1st and 2nd Check Code. • Y = 1 (Setting of Check Sum Data for generating Check Code) (1) 0: For 1st Check Code 1: For 2nd Check Code (2) 0-9: Check Sum Data (Enter desired value) C CMD5 B ID Code programmed Check Code 0 1 2 3 4 5 6 7 8 9 A B C D E F XX2X3X4 X5X6X7X8 DIGIT DATA No Check Code X X X X X X X XX X X X X X X XX X X X X X X XX X X X X X X X X: Significant Digit for Check Code1 *b *a
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 83 Revision 2.0 AUTHORIZATION CODE Note 1:Up to 1,000 Authorization codes combined with Forced Account Codes and Direct Inward System Access (DISA) codes can be defined. Note 2:When deleting all ID codes stored in the PN-AP01 card at one time, do the following operation: + D60 + + 0000 + + CCC + Note 3:When providing Mask Data for Authorization Codes, assign CMD001-160-175 (Refer to the SMDR System Manual). DESCRIPTION DATA Set the Authorization Code and its temporary Class of Service. By entering the Authorization Code, the Check Code will be displayed on the MAT or CAT. • Temporary Class of Service X 1: Type of Temporary Class of Ser- vice 0: Unrestricted 1: Fully-Restricted 2: As per X 2-X9 9: Delete the ID Code X 2X3: Trunk Restriction Class (01-08) specified by CM35 YY = 51-68.•Y = 3 (1) X-X...X: Authorization Code (Max. number of digits specified by CM42-11.) (2) X 1 (Single Digit): When X1 = 0, 1 or 9 X 1X2...X9 (9 digits): When X1 = 2 (See left column) X 4X5: Service Restriction Class (A) (01-15) X 6X7: Service Restriction Class (B) (01-15) X 8X9: Service Restriction Class (C) (01-15) CMD5 C END As per CM15 ST DEDEEXE