    							CHAPTER 2 ND-45670 (E)
    Pag e 3 30
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    (1) X XX
    Status No. (1/2) 
    02: Station cannot be called 
    (Do Not Disturb Set)
    03: Station can be called 
    (Do Not Disturb Reset)
    (2) 0 : No
    1: Yes
    (1) X
     XX
    Status No. (1/2)
    04~07 (See the above table)
    (2) 0 : No
    Specify the system to do not print the Maid 
    Status Record out.(1) 150 (Maid Status Record Printing)
    (2) 1: Not available
    CMD031
    D
    CMD000
    END 
    						
    							ND-45670 (E) CHAPTER 2
    Page 331
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    2. In case of a system without AP card (PN-AP01):
    DESCRIPTION DATA
    Designate the MP card for Authorization 
    Code.(1) 216: Designation of Processor for Au-
    thorization Code
    (2) 0: MP (PN-CP00) card
    Specify the Service Set Tone after dialling the 
    access code for Authorization Code.(1) 362: Provision of Service Set Tone after 
    dialling the access code
    (2) 1 : To be provided
    Set the data for 281 to 1. (Maid ID Code is not 
    used.)(1) 281
    (2) 1 : Not available
    Assign the Service Restriction Class (A) 
    allowed for Authorization Code feature.• YY:31 (Authorization Code)
    (1) Service Restriction Class (A) (00-15)
    (2) 1t: Allowed
    Assign allowed class and restricted class for 
    Maid Status features.• YY=75 (Maid Status)
    (1) Service Restriction Class (B) (00-15)
    (2) 0: Restricted
    1t: Allowed
    To the station that uses PAD LOCK feature, 
    assign the Service Restriction Class (A) 
    allowed for Authorization Code feature. 
    Moreover, to all the station, assign the Service 
    Restriction Class (B) restricted for Maid 
    Status feature.• YY=02
    (1) X-XXXX: Station No.
    (2) XX
     XX
    Service Restriction Class (A)
    Service Restriction Class (B)
    Assign the access code for Authorization 
    Code.• Y=0-3 (Numbering Plan Group 0-3)
    (1) X-XXX: Access Code
    (2) 086: Authorization Code
    CM08
    CM20
    A
    CM15
    CM12 START 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 32
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    Specify the maximum number of digits for 
    Authorization Code.(1)
    (2)11: Authorization Code Max. digits
    Max. number of digits
    01: 1 digit
    08: 8 digits
    NONE : 8 digits
    Set the Authorization Code. •
    (1)
    (2)Y=0
    XX: Code Serial No. (00-99)
    X-X...X: Authorization Code
    Set the purpose and the Temporary Service
    Class of each Authorization Code.•
    (1)
    (2)Y=1 (Purpose of the Code)
    XX: Code Serial No. (00-99)
    1 : Authorization Code
    Service Restriction Class (B) of the Temporary
    Service Class should be set to the allowed class
    for Maid Status.•
    (1)
    (2)Y=3
    XX: Code Serial No. (00-99)
    XX
     XX:
    Service Restriction Class (A) 
    (00-15)
    Service Restriction Class (B) 
    (00-15) 
    (Allowed class for Maid Status)
    Assign the access code for Maid Status. •
    (1)
    (2)YY=0-3 (Numbering Plan Group 0-3)
    X-XXX (Access Code)
    029
    Assign the Class of Service for Maid Status. (1)
    (2)X-XXXX: Station No.
    Service Class No. (00-15)
    CM42
    CM20
    B
    A
    CM2A
    CMD015
    ~
    ~ 
    						
    							ND-45670 (E) CHAPTER 2
    Page 333
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    DESCRIPTION DATA
    Assign the Maid Status Processing to the 
    Service Class assigned by CMD015.(1) XX 06
    Service Class No. assigned by
    CMD015
    (2) 1: Yes
    Allow each Status Number (Restricted/
    Normal) to change the Status Number from 
    the station.
    Note:Desired number can be assigned for
    the Status Number of each status.(1) 1
     31
    Status No. (Restricted) Note
    Allowed to change the Status No.
    from the station
    (2) 1: Yes
    (1) 2
     31
    Status No. (Normal) Note
    Allowed to change the Status No.
    from the station
    (2) 1: Yes
    Assign the originating function, the incoming
    call function, and the other function to each 
    Status Number as following table.(1) 1
     00
    Status No. (Restricted)
    No originating allowed (Room
    Cut Off)
    (2) 1: Yes
    (1) 1
     01
    Status No. (Restricted)
    Originating allowed (Room Cut
    Off Reset)
    (2) 0 : No
    (1) 2
     00
    Status No. (Normal)
    No originating allowed (Room
    Cut Off )
    (2) 1: No
    CMD016
    CMD031
    C
    B
    ROOM 
    STATUS No.FUNCTION
    00 01 02 03 04 05 06 07
    1 
    (Restricted)100/10/10000
    2 
    (Normal)010/10/10000 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 34
    Revision 2.0
    PAD LOCK (1300 Series Enhancement)
    HARDWARE REQUIRED
    PN-AP00 card
    PN-AP01 card is required for providing the Authorization Code:
    • exceeding 8 digits.
    • with check code.
    • total of more than 100 codes.
    DESCRIPTION DATA
    Assign the incoming call function to each 
    Status Number.(1) 2
     01
    Status No. (Normal)
    Originating allowed 
    (Room Cut Off Reset)
    (2) 1: Yes
    (1) X
     XX
    Status No. (1/2)
    02: Station cannot be called 
    (Do Not disturb Set)
    03: Station can be called 
    (Do Not Disturb Reset)
    (2) 0 : No
    1: Yes
    (1) X
     XX
    Status No. (1/2)
    04-~07
    (See the above table)
    (2) 0 : No
    Specify the system to do not print the Maid 
    Status Record out.(1) 150 (Maid Status Record Printing)
    (2) 1:  Not available
    CMD031
    C
    CMD000
    END 
    						
    							ND-45670 (E) CHAPTER 2
    Page 335
    Revision 2.0
    PERIODIC TIME INDICATION TONE
    PROGRAMMING
    DESCRIPTION DATA
    Provide the system with this feature (for C.O 
    lines).
    Specify this service on a Tie Line Call.(1) 135
    (2)  0: To be provided
    (1) 136
    (2)  0/1 : To be provided/Not to be 
    provided.
    Assign the Class of Service for this feature to 
    the required stations.•  CM12 YY = 02 [Service Rest. Class B 
    (00-15 )]
    •  CM15 YY = 61
    (1)  00-15 (Service Rest. Class B assigned by 
    CM12 YY = 02) 
    (2) 1 : Allowed
    Assign as Ordinary Station the required 
    stations. If assigned to 0 (Analog Data 
    Station), this feature will not be applied to the 
    station.•  YY = 07
    (1) X-XXXX (Station No.)
    (2) 1 : Ordinary Station
    Specify the interval time for Periodic Time 
    Indication Tone.•  Y = 0
    (1) 09
    (2)  00: 36 sec.
    01-12: 64-724 sec. in 60 sec. increments
    If no data is set, the default setting is 180-184 
    seconds.CM08 START
    CM41
    CM12
    CM15
    END
    CM13 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 36
    Revision 2.0
    POOLED LINE ACCESS
    PROGRAMMING
    DESCRIPTION DATA
    Assign the Pooled Lines (Virtual Line Station 
    Number) to the required Virtual LEN.
    The Virtual LENs have no relation with the 
    physical LEN used in CM10. Therefore, any 
    Virtual LENs can be assigned to each Virtual 
    Line Station Number. However, the Virtual 
    Line Station Number should be different from 
    the Single Line Number assigned by CM10.(1) Virtual LEN (0000-0255) 
    (2)  X-XXXX (Virtual Line Station No.) 
    Assign the Pooled Line keys to each Multiline 
    Terminal. Pooled Lines 00-63 can answer a 
    call terminated to Tenants 00-63 respectively, 
    and can originate a call using Trunk Routes 
    00-63 respectively.
    Pooled Line 
    Origination Termination
    00  Trunk Route 00  Tenant 00 
    01 01 01 
    63 Trunk Route 63 Tenant 63 •  YY = 00
    (1)  Primary Extension No. +   + Key No. 
    (2)  F4100-F4163 (Pooled Line 00-63) 
    CM11 START
    CM90
    A
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 337
    Revision 2.0
    POOLED LINE ACCESS
    HARDWARE REQUIRED 
    ETJ-8-1/ETJ-16DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/4DLCA card. 
    DESCRIPTION DATA
    Assign a Trunk Route No. and Tenant No. to 
    the trunks in the Pooled Line group. 
    Note:Refer to the Command Manual for
    the Resident System Program. •  YY = 00 (Trunk Route Allocation) 
    (1) 000-255 (Trunk No.) 
    (2)  00-63 (Trunk Route No.) 
    Note
    •  YY = 01 (Allocation of tenants to trunks) 
    (1) 000-255 (Trunk No.) 
    (2)  00-63 (Tenant No.) (00) 
    Specify the terminating system, including 
    TAS, of the trunks in the Pooled Line group.•  YY = 02 (Terminating System in Day 
    mode) 
    •  YY = 03 (Terminating System in Night 
    mode) 
    (1) 000-255 (Trunk No.) 
    (2)  03: Trunk-Direct Appearances and TAS
    13: TAS 
    19: SN610 ATTCON + TAS
    20: SN610 ATTCON + Trunk Direct 
    Appearances + TAS 
    Specify whether call terminating is indicated 
    on the Pooled Line keys assigned by CM90-
    F4100-F4163. (1) 116 
    (2)  0/1 : Available/Not Available
    END
    CM30
    A
    CM08 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 38
    Revision 2.0
    POWER FAILURE TRANSFER
    PROGRAMMING
    To use the PN-AUC card:
    To use the PZ-8PFT card:
    No programming is required.
    HARDWARE REQUIRED
    PN-AUC card and PN-4COT card, or PZ-8PFT card.
    Make the following connections between the cards. For details, refer to the MDF cross connection for the PFT in
    the INSTALLATION PROCEDURE MANUAL.
    DESCRIPTION DATA
    Assign the PN-AUCA cards to the required 
    LENs. (1) LEN: 0000-0511
    (2)  X-XXXX: Station No. 
    Assign the PN-4COT cards to the required 
    LENs.(1) LEN: 0000-0511
    (2)  D000-D255: Trunk No.CM10 START
    END
    To use the PN-AUC card:
    To use the PZ-8PFT card:
    ...
    ..MD F
    TO C.O. L INE PBX
    MDF TEL
    .....MDF
    TO C.O. L INE PBX
    MDF TEL.
    MDF..
    PN-4LCPN-4COT
    PN-AUC
    PN-4COT 
    						
    							ND-45670 (E) CHAPTER 2
    Page 339
    Revision 2.0
    PRIORITY CALL
    PROGRAMMING 
    DESCRIPTION DATA
    Assign the Class of Service for Priority Call to 
    the required stations. •  CM12 YY = 02 (Service Rest. Class A 
    00-15 ) 
    • CM15 
    •  YY = 17 (Priority Call 0) 
    •  YY = 18 (Priority Call 1) 
    (1)  00-15 (Service Restriction Class A as-
    signed by CM12 YY = 02) 
    (2) 1 : Allowed
    Assign the access code for Priority Calls 0 and 
    1 respectively. •  Y = 0-3 (Numbering Plan Group 0-3) 
    (1)  X-XXX (Access Code) 
    (2)  088: Priority Call 0 
    089: Priority Call 1
    Specify the destination for Priority Calls 0 and 
    1. (1)  250 (For Priority Call 0) 
    (2)  0: Same Station as Off Hook Alarm 
    1 : SN610 ATTCON 
    (1)  251 (For Priority Call 1) 
    (2)  0: Same station as Off-Hook Alarm 
    1 : SN610 ATTCON 
    If CM08-250/251 is set to “1”, assign the Pri-
    ority Calls 0 and 1 to any Priority Call Keys on 
    SN610 ATTCON. •  YY = 00
    (1)  ATTCON No. +   + Key No.
    (2)  F6054: Priority Call 0 
    F6055: Priority Call 1
    If CM08-250/251 is set to “0”, assign the des-
    tination of Priority Calls 0 and 1 to the desired 
    station. •  YY = 12
    (1)  Tenant No. (00-63) 
    (2) X-XXXX (Station No.) 
    CM51 START
    CM08
    CM12
    CM15
    END
    CM20
    CM90, 
    						