CHAPTER 2 ND-45670 (E) Pag e 3 30 Revision 2.0 PAD LOCK (1300 Series Enhancement) DESCRIPTION DATA (1) X XX Status No. (1/2) 02: Station cannot be called (Do Not Disturb Set) 03: Station can be called (Do Not Disturb Reset) (2) 0 : No 1: Yes (1) X XX Status No. (1/2) 04~07 (See the above table) (2) 0 : No Specify the system to do not print the Maid Status Record out.(1) 150 (Maid Status Record Printing) (2) 1: Not available CMD031 D CMD000 END
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 331 Revision 2.0 PAD LOCK (1300 Series Enhancement) 2. In case of a system without AP card (PN-AP01): DESCRIPTION DATA Designate the MP card for Authorization Code.(1) 216: Designation of Processor for Au- thorization Code (2) 0: MP (PN-CP00) card Specify the Service Set Tone after dialling the access code for Authorization Code.(1) 362: Provision of Service Set Tone after dialling the access code (2) 1 : To be provided Set the data for 281 to 1. (Maid ID Code is not used.)(1) 281 (2) 1 : Not available Assign the Service Restriction Class (A) allowed for Authorization Code feature.• YY:31 (Authorization Code) (1) Service Restriction Class (A) (00-15) (2) 1t: Allowed Assign allowed class and restricted class for Maid Status features.• YY=75 (Maid Status) (1) Service Restriction Class (B) (00-15) (2) 0: Restricted 1t: Allowed To the station that uses PAD LOCK feature, assign the Service Restriction Class (A) allowed for Authorization Code feature. Moreover, to all the station, assign the Service Restriction Class (B) restricted for Maid Status feature.• YY=02 (1) X-XXXX: Station No. (2) XX XX Service Restriction Class (A) Service Restriction Class (B) Assign the access code for Authorization Code.• Y=0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) 086: Authorization Code CM08 CM20 A CM15 CM12 START
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 3 32 Revision 2.0 PAD LOCK (1300 Series Enhancement) DESCRIPTION DATA Specify the maximum number of digits for Authorization Code.(1) (2)11: Authorization Code Max. digits Max. number of digits 01: 1 digit 08: 8 digits NONE : 8 digits Set the Authorization Code. • (1) (2)Y=0 XX: Code Serial No. (00-99) X-X...X: Authorization Code Set the purpose and the Temporary Service Class of each Authorization Code.• (1) (2)Y=1 (Purpose of the Code) XX: Code Serial No. (00-99) 1 : Authorization Code Service Restriction Class (B) of the Temporary Service Class should be set to the allowed class for Maid Status.• (1) (2)Y=3 XX: Code Serial No. (00-99) XX XX: Service Restriction Class (A) (00-15) Service Restriction Class (B) (00-15) (Allowed class for Maid Status) Assign the access code for Maid Status. • (1) (2)YY=0-3 (Numbering Plan Group 0-3) X-XXX (Access Code) 029 Assign the Class of Service for Maid Status. (1) (2)X-XXXX: Station No. Service Class No. (00-15) CM42 CM20 B A CM2A CMD015 ~ ~
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 333 Revision 2.0 PAD LOCK (1300 Series Enhancement) DESCRIPTION DATA Assign the Maid Status Processing to the Service Class assigned by CMD015.(1) XX 06 Service Class No. assigned by CMD015 (2) 1: Yes Allow each Status Number (Restricted/ Normal) to change the Status Number from the station. Note:Desired number can be assigned for the Status Number of each status.(1) 1 31 Status No. (Restricted) Note Allowed to change the Status No. from the station (2) 1: Yes (1) 2 31 Status No. (Normal) Note Allowed to change the Status No. from the station (2) 1: Yes Assign the originating function, the incoming call function, and the other function to each Status Number as following table.(1) 1 00 Status No. (Restricted) No originating allowed (Room Cut Off) (2) 1: Yes (1) 1 01 Status No. (Restricted) Originating allowed (Room Cut Off Reset) (2) 0 : No (1) 2 00 Status No. (Normal) No originating allowed (Room Cut Off ) (2) 1: No CMD016 CMD031 C B ROOM STATUS No.FUNCTION 00 01 02 03 04 05 06 07 1 (Restricted)100/10/10000 2 (Normal)010/10/10000
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 3 34 Revision 2.0 PAD LOCK (1300 Series Enhancement) HARDWARE REQUIRED PN-AP00 card PN-AP01 card is required for providing the Authorization Code: • exceeding 8 digits. • with check code. • total of more than 100 codes. DESCRIPTION DATA Assign the incoming call function to each Status Number.(1) 2 01 Status No. (Normal) Originating allowed (Room Cut Off Reset) (2) 1: Yes (1) X XX Status No. (1/2) 02: Station cannot be called (Do Not disturb Set) 03: Station can be called (Do Not Disturb Reset) (2) 0 : No 1: Yes (1) X XX Status No. (1/2) 04-~07 (See the above table) (2) 0 : No Specify the system to do not print the Maid Status Record out.(1) 150 (Maid Status Record Printing) (2) 1: Not available CMD031 C CMD000 END
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 335 Revision 2.0 PERIODIC TIME INDICATION TONE PROGRAMMING DESCRIPTION DATA Provide the system with this feature (for C.O lines). Specify this service on a Tie Line Call.(1) 135 (2) 0: To be provided (1) 136 (2) 0/1 : To be provided/Not to be provided. Assign the Class of Service for this feature to the required stations.• CM12 YY = 02 [Service Rest. Class B (00-15 )] • CM15 YY = 61 (1) 00-15 (Service Rest. Class B assigned by CM12 YY = 02) (2) 1 : Allowed Assign as Ordinary Station the required stations. If assigned to 0 (Analog Data Station), this feature will not be applied to the station.• YY = 07 (1) X-XXXX (Station No.) (2) 1 : Ordinary Station Specify the interval time for Periodic Time Indication Tone.• Y = 0 (1) 09 (2) 00: 36 sec. 01-12: 64-724 sec. in 60 sec. increments If no data is set, the default setting is 180-184 seconds.CM08 START CM41 CM12 CM15 END CM13
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 3 36 Revision 2.0 POOLED LINE ACCESS PROGRAMMING DESCRIPTION DATA Assign the Pooled Lines (Virtual Line Station Number) to the required Virtual LEN. The Virtual LENs have no relation with the physical LEN used in CM10. Therefore, any Virtual LENs can be assigned to each Virtual Line Station Number. However, the Virtual Line Station Number should be different from the Single Line Number assigned by CM10.(1) Virtual LEN (0000-0255) (2) X-XXXX (Virtual Line Station No.) Assign the Pooled Line keys to each Multiline Terminal. Pooled Lines 00-63 can answer a call terminated to Tenants 00-63 respectively, and can originate a call using Trunk Routes 00-63 respectively. Pooled Line Origination Termination 00 Trunk Route 00 Tenant 00 01 01 01 63 Trunk Route 63 Tenant 63 • YY = 00 (1) Primary Extension No. + + Key No. (2) F4100-F4163 (Pooled Line 00-63) CM11 START CM90 A ,
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 337 Revision 2.0 POOLED LINE ACCESS HARDWARE REQUIRED ETJ-8-1/ETJ-16DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/4DLCA card. DESCRIPTION DATA Assign a Trunk Route No. and Tenant No. to the trunks in the Pooled Line group. Note:Refer to the Command Manual for the Resident System Program. • YY = 00 (Trunk Route Allocation) (1) 000-255 (Trunk No.) (2) 00-63 (Trunk Route No.) Note • YY = 01 (Allocation of tenants to trunks) (1) 000-255 (Trunk No.) (2) 00-63 (Tenant No.) (00) Specify the terminating system, including TAS, of the trunks in the Pooled Line group.• YY = 02 (Terminating System in Day mode) • YY = 03 (Terminating System in Night mode) (1) 000-255 (Trunk No.) (2) 03: Trunk-Direct Appearances and TAS 13: TAS 19: SN610 ATTCON + TAS 20: SN610 ATTCON + Trunk Direct Appearances + TAS Specify whether call terminating is indicated on the Pooled Line keys assigned by CM90- F4100-F4163. (1) 116 (2) 0/1 : Available/Not Available END CM30 A CM08
![](/img/blank.gif)
CHAPTER 2 ND-45670 (E) Pag e 3 38 Revision 2.0 POWER FAILURE TRANSFER PROGRAMMING To use the PN-AUC card: To use the PZ-8PFT card: No programming is required. HARDWARE REQUIRED PN-AUC card and PN-4COT card, or PZ-8PFT card. Make the following connections between the cards. For details, refer to the MDF cross connection for the PFT in the INSTALLATION PROCEDURE MANUAL. DESCRIPTION DATA Assign the PN-AUCA cards to the required LENs. (1) LEN: 0000-0511 (2) X-XXXX: Station No. Assign the PN-4COT cards to the required LENs.(1) LEN: 0000-0511 (2) D000-D255: Trunk No.CM10 START END To use the PN-AUC card: To use the PZ-8PFT card: ... ..MD F TO C.O. L INE PBX MDF TEL .....MDF TO C.O. L INE PBX MDF TEL. MDF.. PN-4LCPN-4COT PN-AUC PN-4COT
![](/img/blank.gif)
ND-45670 (E) CHAPTER 2 Page 339 Revision 2.0 PRIORITY CALL PROGRAMMING DESCRIPTION DATA Assign the Class of Service for Priority Call to the required stations. • CM12 YY = 02 (Service Rest. Class A 00-15 ) • CM15 • YY = 17 (Priority Call 0) • YY = 18 (Priority Call 1) (1) 00-15 (Service Restriction Class A as- signed by CM12 YY = 02) (2) 1 : Allowed Assign the access code for Priority Calls 0 and 1 respectively. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX (Access Code) (2) 088: Priority Call 0 089: Priority Call 1 Specify the destination for Priority Calls 0 and 1. (1) 250 (For Priority Call 0) (2) 0: Same Station as Off Hook Alarm 1 : SN610 ATTCON (1) 251 (For Priority Call 1) (2) 0: Same station as Off-Hook Alarm 1 : SN610 ATTCON If CM08-250/251 is set to “1”, assign the Pri- ority Calls 0 and 1 to any Priority Call Keys on SN610 ATTCON. • YY = 00 (1) ATTCON No. + + Key No. (2) F6054: Priority Call 0 F6055: Priority Call 1 If CM08-250/251 is set to “0”, assign the des- tination of Priority Calls 0 and 1 to the desired station. • YY = 12 (1) Tenant No. (00-63) (2) X-XXXX (Station No.) CM51 START CM08 CM12 CM15 END CM20 CM90,