CHAPTER 2 ND-45670 (E) Pag e 3 72 Revision 2.0 STATION HUNTING: STATION HUNTING-SECRETARIAL PROGRAMMING DESCRIPTION DATA Assign a Secretary Station Serial Number to each Station Hunting Group. Note:A maximum of 31 extensions can be members of the Secretarial Hunt group.•Y=2 (1) X-XXXX: Pilot Station No. (Terminal)/ All Member Station numbers (Circular) (2) 00-30 (Secretary Station Serial No.) Assign a station number to each Secretary Sta- tion Serial Number assigned by CM18Y=2.•Y=0 (1) 00-30 (Secretary Station Serial Number) (2) X-XXXX (Secretary Station No.) Specify the Hunting capability of each Secre- tary Station.• Y = 1 (1) 00-30 (Secretary Station Serial No.) (2) 5: Hunting (As per Y=2) 7: No Hunting Assign the Secretary Station Numbers, one by one, in order of the desired Secretary Hunting, as shown below. 1st Operation (1) Station A (2) Station B 2nd Operation (1) Station B (2) Station C•Y=2 (1) X-XXXX (Secretary Station No.) (2) X-XXXX (Another Secretary Station No. to be hunted to.) Allow or restrict the ability to set Station Hunting-Secretarial for a station with Do Not Disturb set.(1) 240 (2) 0: Allow 1 : Restrict START END CM18 CM19 CM08

ND-45670 (E) CHAPTER 2 Page 373 Revision 2.0 STATION MESSAGE DETAIL RECORDING (SMDR) PROGRAMMING Refer to the SMDR System Manual. HARDWARE REQUIRED Refer to the SMDR System Manual.

CHAPTER 2 ND-45670 (E) Pag e 3 74 Revision 2.0 STATION SPEED DIALING PROGRAMMING 1. To provide an Extension Memory card (PN-ME00) for extending memory for Station Speed Dialing and One Touch keys: DESCRIPTION DATA Assign a slot number to the Extension Memory card. The slot number is given by the SENSE switch on the Extension Memory card.(1) 04-15 (Slot Number) (2) 19 (PN-ME00 card) Provide the system with the Extension Memory card.(1) 56 (2) 1: To be provided START CM05 CMD000 END INITIAL

ND-45670 (E) CHAPTER 2 Page 375 Revision 2.0 STATION SPEED DIALING 2. To provide Single Line Telephone or Multiline Terminal: DESCRIPTION DATA Specify whether 1000-Slot Memory Block has 26 digits or 16 digits memory buffers. Note:When CM08-252 is assigned as 0, only 3000 Station Speed Dialing numbers can be assigned, and 1000-Slot Memory Block No. 0-2 contains 26-digits memo- ry buffers. When CM08-252 is assigned as 1, 4500 Station Speed Dialing num- bers can be assigned, and 1000-Slot Memory Block No. 0-4 contains 16-dig- its memory buffers.(1) 252 (2) 0/1 : 26/16 digitsNote:Regardless of this data setting, a maximum of 26 digits number can be stored to Extension Memory card’s memory area (1000-Slot Memory Block No. 8-F). Assign Service Restriction Class A to each sta- tion.• YY = 02 (1) X-XXXX (Station No.) (2) XX XX *a *a: Service Restriction Class A (00-15 ) Assign this service to Service Restriction Class A assigned by CM12 YY = 02.• YY = 07 (1) 00-15: Service Restriction Class A (2) 1 : Allowed Assign access codes for Station Speed Dialing, Origination, Entry and Cancel, respectively.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (#*, 7*, 7#) (2) 064: Origination 065: Entry 066: Cancel Specify whether to provide Toll Restriction for an outgoing call by Station Speed Dialing.(1) 035 (2) 0/1 : Not provided/Provided Specify whether to set “#” dialing as paused data (1.5 sec.) or called number to C.O. line when DTMF station or Multiline Terminal dials “#” in the setting of Station Speed Dialing feature.(1) 168 (2) 0/1 : Paused data (1.5 sec.)/ Called number to C.O. line START CM08 CM12 CM15 CM20 CM08 A

CHAPTER 2 ND-45670 (E) Pag e 3 76 Revision 2.0 STATION SPEED DIALING DESCRIPTION DATA Specify “*” dialing is set as programmable pause by CM41-38 or dialed digit when the DTMF station or Multiline Terminal dials “*” in the setting of the Station Speed Dialing fea- ture.(1) 171 (2) 0/1 :Programmable pause by CM41- 38/Dialed digit Allocate the memory area for Station Speed Dialing to each station. The memory block for storing one called number of Station Speed Dialing is called a “Memory Parcel”. An as- sembly of 10-Memory Parcels is called a “10 Slot Memory Block,” and one hundred 10- Slot Memory Blocks are called a “1000-Slot Memory Block”.(1) X-XXXX (Station No.) (2) X XX X XX *a *b *c *d (3) *a:000-Slot Memory Block No. 0-4, 8-F Note 1 *b:Memory Start Block No. 00-99: (10-Slot Memory Block) Note 2 *c:Facility for programming the dialed number from the Station (0/1: Effective/Ineffective) *d:Number of blocks in Memory Parcel (01-10) CM08 CM73 B A The number of Memory Parcels for a station is specified by the data shown below. DataNumber of Memory Parcels Abbreviated Codes required for accessing this feature are automatically given to each station, depending on the number of Memory Parcels specified. XXXX01 10 XXXX10 100 0 4 1 2 3 1000-Slot Memory Block0 9 1 Memory Parcel00 99 01 10-Slot Memory Block1000 Memory Parcels 1000 Memory Parcels 1000 Memory Parcels 1000 Memory Parcels 500 Memory Parcels

ND-45670 (E) CHAPTER 2 Page 377 Revision 2.0 STATION SPEED DIALING DESCRIPTION DATA Note 1: If the system provides the Extension Memory card, 1000-Slot Memory Block No. 8-F (8000 Memory Parcels) can be used. For using this memory area, there are several conditions as mentioned below: • This memory area cannot be used for Speed Dialing with Speed Dialing keys provided by CM90-second data: F11XX on a Multiline Terminal, and cannot also be used for System Speed Dialing. • When exchanging an Extension Memory card for another, data setting for this memory area must be recommenced. • The Office Data in this memory area cannot be saved and loaded by MAT operations. Note 2:When the 1000-Slot Memory Block specifier is 4, Memory Start Block No. should be set to 00-49. Less than 100 Memory Parcels for a station: In excess of 100 Memory Parcels for a station: Assign the number to be dialed to each Mem- ory Slot Number, if required. The numbers to be called are usually set from individual sta- tions by their station users.(1) X XXX (Memory Slot No.) *a *b *a: 1000-Slot Memory Block Num- ber (0-4, 8-F) *b: 000-999 (2) Stored No. Setting Method: Outgoing Call Access Code (Max. 2 dig- its) + + Stored Number (Max. 16/26 digits) To set a pause into the Stored No., enter “C” (Fixed Pause=1.5 sec.) or “D” (Programmable Pause specified by CM41-38) after desired digits. B CM74 C 0 9 1 Memory Parcel 10-Slot Memory Block X Memory Parcel 0 9 1 0 9 1 10-Slot Memory Block X 99 10-Slot Memory Block XX 0 1 99 Abbreviated Codes ,

CHAPTER 2 ND-45670 (E) Pag e 3 78 Revision 2.0 STATION SPEED DIALING DESCRIPTION DATA Assign Station Speed Dialing keys on each Multiline Terminal, if required.• YY=00 (1) Primary Extension No. + + Key No. (01-24) (2) F11XX *a *a: 00: Station Speed Dialing 00 99: Station Speed Dialing 99 CM90 C END ,

ND-45670 (E) CHAPTER 2 Page 379 Revision 2.0 STATION SPEED DIALING 3. To provide Multiline Terminal with One Touch keys (ETJ-16DD-1/ETJ-24DS-1/DTP-32-1/DTP-32D-1): DESCRIPTION DATA Specify whether 1000-Slot Memory Block has 26 digits or 16 digits memory buffers. Note 1:When CM08-252 is assigned as 0, only 3000 Station Speed Dialing numbers can be assigned, and 1000- Slot Memory Block No. 0-2 contains 26-digits memory buffers. When CM08-252 is assigned as 1, 4500 Station Speed Dialing numbers can be assigned and 1000-Slot Memory Block No. 0-4 contains 16-digits memory buffers.(1) 252 (2) 0/1 : 26/16 digitsNote 2:Regardless of this data setting, a maximum of 26 digits number can be stored to Extension Memory card’s memory area (1000-Slot Memory Block No. 8-F). Assign Service Restriction Class A to each station.• YY = 02 (Service Restriction Class A·B) (1) X-XXXX (Station No.) (2) XX XX *a *a: Service Restriction Class A (00-15 ) Assign this service to Service Restriction Class A assigned by CM12 YY = 02.• YY = 07 (1) 00-15: Service Restriction Class A (2) 1 : Allowed Specify whether to provide Toll Restriction for an outgoing call by Station Speed Dialing.(1) 035 (2) 0/1 : Not provided/Provided Specify whether to set “#” dialing as paused data (1.5 sec.) or called number to C.O. line when Multiline Terminal dials “#” in the set- ting of Station Speed Dialing feature.(1) 168 (2) 0/1 : Paused data (1.5 sec.)/ Called number to C.O. line Specify whether to set “*” dialing as program- mable pause by CM41-38 or dialed digit when DTMF station or Multiline Terminal dials “*” in the setting of Station Speed Dialing feature.(1) 171 (2) 0/1 : Programmable pause by CM41- 38/Dialed digit START CM08 A CM12 CM15 CM08

CHAPTER 2 ND-45670 (E) Pag e 3 80 Revision 2.0 STATION SPEED DIALING DESCRIPTION DATA Allocate the memory area for Station Speed Dialing to each station. The memory block for storing one called number of Station Speed Dialing is called a “Memory Parcel”. An assembly of 10-Memory Parcels is called a “10 Slot Memory Block,” and one hundred 10-Slot Memory Blocks are called a “1000- Slot Memory Block”.(1) X-XXXX (Primary Extension No.) (2) X XX 0 XX *a *b *c *a: 1000-Slot Memory Block No. (0-4, 8-F) *b: Start of 10-Slot Memory Block No. (00-49) *c: Number of 10-Slot Memory Blocks 02: ETJ-16DD-1/ETJ- 24DS-1 (20 numbers) The ETJ-16DD-1/ETJ-24DS-1 requires two 10-Slot Memory Blocks (20 numbers). Note:1000-Slot Memory Block No. 8-F can be used when the system pro- vides the Extension Memory card. If assigning the station number to One Touch keys using this memory area, the lamp does not show the busy state. CM94 A END 0 4 1 2 3 1000-Slot Memory Block0 9 1 Memory Parcel00 99 01 10-Slot Memory Block1000 Memory Parcels 1000 Memory Parcels 1000 Memory Parcels 1000 Memory Parcels 500 Memory Parcels 00 49 01

ND-45670 (E) CHAPTER 2 Page 381 Revision 2.0 STATION SPEED DIALING 4. To provide the One Touch key to send “Hooking Signal + Called Number” to a Centrex, set the following data in addition to the programming (2). (1500 Series Enhancement) 5. To provide the One Touch key to send “Called Number + DTMF Signal” for such as VMS operation, set the following data in addition to the programming (2), when the called number includes a trunk access code. If the called number includes no trunk access code, this data is not required. (1500 Series Enhancement) DESCRIPTION DATA Assign the access code for sending of a Hook- ing signal to a Centrex. Maximum of two digits are available.•Y = 0-3 (1) X-XX: Access code (2) A58: Hooking signal to a Centrex Assign a RECALL key on the Multiline Ter- minal. RECALL key is used to return to a former line.• YY = 00 (1) Primary Extension No. + + key No. (2) F1015: RECALL Provide Centrex trunk route with Centrex function.• YY = 86 (1) Trunk Route No. (00-63) (2) 0: Centrex DESCRIPTION DATA Specify whether to set consecutive dialing “* #” as a delimiter between the called number and the DTMF signal.(1) 448 (2) 0 : *# (as it is) 1 : Delimiter between called number and DTMF signal CM35 START END CM20 CM90 , START END CM08