NEC Neax2000 Ivs Feature Programming Manual
Have a look at the manual NEC Neax2000 Ivs Feature Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 2 ND-45670 (E) Pag e 3 82 Revision 2.0 STEP CALL PROGRAMMING DESCRIPTION DATA Provide the system with the Step-Call feature. Note:This feature is mutually exclusive with the single digit feature access code.(1) 069 (For internal Call) (2) 1 : Available (1) 163 (For Tie Line Incoming Call) (2) 1 : Available (1) 208 Note (2) 1 : Not Available START END CM08
ND-45670 (E) CHAPTER 2 Page 383 Revision 2.0 SUPERVISORY CONTROL OF PERIPHERAL EQUIPMENT PROGRAMMING DESCRIPTION DATA Provide the Station connected to the peripher- al equipment with momentary reversal/open capability.• YY = 22 (1) X-XXXX (Station No.) (2) 0: To be provided Specify the duration of the momentary rever- sal/open.• Y = 1 (1) 08 (2) 01-10: 128-1280 msec. in 128 msec. increments If no data is set, the default setting is 896-1024 msec. START END CM13 CM41
CHAPTER 2 ND-45670 (E) Pag e 3 84 Revision 2.0 SYSTEM SPEED DIALING PROGRAMMING DESCRIPTION DATA Assign Service Restriction Class A to each station. • YY = 02 (1) X-XXXX (Station No.) (2) XX XX *a: Service Restriction Class (A) 00- 15 Assign this service to Service Restriction Class A assigned by CM12 YY = 02.• YY = 06 (System Speed Dialing) (1) XX (Service Rest. Class A assigned by CM12 YY = 02) (2) 1 : To be allowed Assign the Access Code for System Speed Di- aling.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (##) (2) 067 (System Speed Dialing) Assign an access key for System Speed Dial- ing to the D terms, as needed. • YY = 00 (1) Primary Extension No. + + key No. (2) F0067: System Speed Dialing origina- tion (For 300 numbers) F0068: System Speed Dialing origina- tion (For 1000 numbers) START CM12 CM15 A CM20 CM90 *a ,
ND-45670 (E) CHAPTER 2 Page 385 Revision 2.0 SYSTEM SPEED DIALING DESCRIPTION DATA Assign the memory block for System Speed Dialing. 300 memory slots are available per system. The number of slots available for each Tenant is also 300. Note that the memory blocks for Hot Line-Outside and Route Ad- vance (from Tie Line to C.O. Line) are includ- ed in 300 memory slots. Abbreviated Call Codes required for access- ing this feature are automatically given to each Tenant as shown in the following example. (1) 00-63 (For stations within the Tenant 00- 63) 64 (For ATTCON) (2) XXX XXX Note *a: First Memory/Slot No. in Block. (000-299) *b: Number of Slots to be allocated in Block. (001-300) For example, to provide 20 memory slots starting at Slot 60: Data: 060020 Assign the number to be called to the Memory Slot Number allocated by CM71. (1) Memory Slot No. (000-299) (2) Stored Number (Max. 26 digits) Stored Number: Outgoing Access Code (Max. 2 digits) + + Stored Number (Max. 26 digits) To set a pause into the Stored No., enter “C” (Fixed pause = 1.5 sec) or “D” (Pro- grammable pause specified by CM41-38) after desired digits (more than 2 digits). Specify System Speed Dialing security. (Stored number displays on Multiline Termi- nal for an outgoing call by System Speed Di- aling.) Specify Toll Restriction for an outgoing call by System Speed Dialing, if required. (1) 043 (2) 0/1 : Not to be displayed/To be dis- played. (1) 044 (2) 0/1 : Not to be provided/To be provid- ed. CM71 A CM72 END CM08 TENANT 00 SLOT 000 SLOT 019 20 MEMORY SLOTS00 19 ABBREVIATED CODES TENANT 01 SLOT 020 SLOT 034 15 MEMORY SLOTS00 14 ABBREVIATED CODES Note:By loading the Resident System Program, the following data is assigned for Tenant 00. *a *b ,
CHAPTER 2 ND-45670 (E) Pag e 3 86 Revision 2.0 SYSTEM SPEED DIALING To use the 1000 Slot Memory Block Number (0-3) for Station Speed Dialing as the Memory Block for System Speed Dialing, add the following programming. DESCRIPTION DATA Specify the 1000-Slot Memory Block Number 0-3.(1) 112: 1000-Slot Memory Block No.0 (2) 0/1 : Available/Not Available (1) 111: 1000-Slot Memory Block No.1 (2) 0/1 : Available/Not Available (1) 176: 1000-Slot Memory Block No.2 (2) 0/1 : Available/Not Available (1) 110: 1000-Slot Memory Block No.3 (2) 0/1 : Available/Not Available Specify whether 1000-Slot Memory Block has 26-digits or 16-digits memory buffers. Note:When CM08-252 is assigned as 0, only 3000 Station Speed Dialing numbers can be assigned, and 1000- Slot Memory Block No. 0-2 contains 26-digits memory buffers. When CM08-252 is assigned as 1, 4000 Station Speed Dialing numbers can be assigned, and 1000-Slot Memory Block No. 0-3 contains 16-digits memory buffers.(1) 252 (2) 0/1 : 26/16-digits Assign the Access Code for System Speed Di- aling.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX (Access Code) (2) A52: 1000-Slot Memory Block No.0 A51: 1000-Slot Memory Block No.1 068: 1000-Slot Memory Block No.2 A50: 1000-Slot Memory Block No.3 START CM08 A CM20
ND-45670 (E) CHAPTER 2 Page 387 Revision 2.0 SYSTEM SPEED DIALING DESCRIPTION DATA Assign the stored number to each Memory Slot Number.(1) X XXX (Memory Slot No.) *a: 1000-Slot Memory Block Number (0-3) *b: 000-999 (2) Stored No. (Max. 16/26 digits) Setting Method: Outgoing Call Access Code (Max.2 digits) + + Stored No. (Max. 16/26 digits) To set a pause into the stored No., enter “C” (Fixed Pause = 1.5 sec) or “D” (Programma- ble Pause specified by CM41-38) after desired digits.CM74 A END *a *b ,
CHAPTER 2 ND-45670 (E) Pag e 3 88 Revision 2.0 TENANT SERVICE PROGRAMMING DESCRIPTION DATA Assign a Tenant No. to each station. • YY = 04 (1) X-XXXX (Station No.) (2) 00 -63 (Tenant No.) Assign a Tenant No. to each trunk. • YY = 01 (1) 000-255 (Trunk No.) (2) 00 -63 (Tenant No.) Assign a Numbering Plan Group No. to each Tenant. (1) 00-63 (Tenant No.) (2) 710-713 (Numbering Plan Group 0-3) Assign the required access codes for each Numbering Plan Group. To provide a trunk route for each Tenant, assign Tenant Block 00- 23 to the desired Trunk Route access code. Note:Refer to the Command Manual for the Resident System Program. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX (Access Code) Note (2) 000-099 801-811 A00-A52 100-163 300-323 (Tenant Block 00-23) When Tenant Block 00-23 is assigned by CM20, assign a trunk route and Tenant No. to the Tenant Block. • YY = 00-23 (Tenant Block 00-23) (1) 00-63 (Tenant No.) (2) 100-163 (Trunk Route 00-63) START CM12 CM30 A CM29 CM20 CM23
ND-45670 (E) CHAPTER 2 Page 389 Revision 2.0 TENANT SERVICE DESCRIPTION DATA To provide external keys for the Day/Night mode changeover or the Class of Service changeover, assign a Tenant No. to each cir- cuit No. on the PN-DK00 card. • YY = 00 (1) XX X *a: Card No. (00-63) for PN-DK00 as- signed by CM10 (E900-E963) *b: Circuit No. (0-7) (2) 00-63 (Tenant No.) Specify the Tenants to be handled by each SN610 ATTCON Group. • Y = 0-3 (ATTCON Group 0-3 assigned by CM60 YY = 00) (1) 00-63 (Tenant No.) (2) 0/1 : To be handled/Not to be handled Specify whether Inter-Tenant connection is available for station-to-station calling, incom- ing call termination and TAS answer.• Y = 0 (TAS Answer) (1) XX XX *a: Tenant No. of TAS Answer Station *b: Tenant No. of Trunk (2) 0/1 : Allowed/Restricted • Y = 1 (Station to Station Calling) (1) XX XX *a: Tenant No. of Calling Station *b: Tenant No. of Called Station (2) 0/1 : Restricted/Allowed • Y = 2 (Incoming Call Termination) (1) XX XX *a: Tenant No. of Called Station *b: Tenant No. of Trunk (2) 0/1 : Restricted/Allowed CM61 A CM63 END CM62 *a *b INITIAL *a *b *a *b *a *b
CHAPTER 2 ND-45670 (E) Pag e 3 90 Revision 2.0 TIE LINE TANDEM SWITCHING PROGRAMMING HARDWARE REQUIRED Tie Line Trunk Card (PN-2ODT) DESCRIPTION DATA Specify the combination of Trunk Routes al- lowing the Tandem connection. The incoming trunk route must provide a release signal for the Tandem Connection. (See CM35 YY = 05) (1) XX XX *a: 00-63 (Incoming Trunk Route) *b: 00-63 (Outgoing Trunk Route) (2) 0/1 : Allowed/Restricted START END CM36*a *b
ND-45670 (E) CHAPTER 2 Page 391 Revision 2.0 TIMED QUEUE PROGRAMMING HARDWARE REQUIRED ETJ-8-1/ETJ-10DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/PN-4DLCA card. DESCRIPTION DATA Specify the timer data for this feature. If no data is set, the following data is applied: • Number of Call Attempts: 3 times • Interval Time of Call Attempt: 120 sec. - 124 sec. • Duration of Calling: 28 sec. -32 sec.• Y = 0 (1) 35 (Number of Times of Call Attempt) (2) 01-07: Once-7 times (1) 36 (Interval time of Call Attempt) (2) 11-31: 44 -124 sec. in 4 sec. increments (1) 37 (Duration of Calling) (2) 05-31: 20-124 sec. in 4 sec. increments Assign the Call Back feature to the required key on the Multiline Terminals, as required.• YY = 00 (1) Primary Extension No. + + Key No. (2) F0004 START END CM41 CM90 ,