    							CHAPTER 2 ND-45670 (E)
    Pag e 3 82
    Revision 2.0
    STEP CALL
    PROGRAMMING 
    DESCRIPTION DATA
    Provide the system with the Step-Call feature.
    Note:This feature is mutually exclusive
    with the single digit feature access
    code.(1)  069 (For internal Call) 
    (2)  1 : Available
    (1)  163 (For Tie Line Incoming Call) 
    (2)  1 : Available
    (1) 208 
    Note 
    (2)  1 : Not Available
    START
    END
    CM08 
    						
    							ND-45670 (E) CHAPTER 2
    Page 383
    Revision 2.0
    SUPERVISORY CONTROL OF PERIPHERAL EQUIPMENT
    PROGRAMMING
    DESCRIPTION DATA
    Provide the Station connected to the peripher-
    al equipment with momentary reversal/open 
    capability.•  YY = 22
    (1) X-XXXX (Station No.) 
    (2)  0: To be provided 
    Specify the duration of the momentary rever-
    sal/open.•  Y = 1 
    (1) 08
    (2)  01-10: 128-1280 msec. in 128 msec. 
    increments
    If no data is set, the default setting is 896-1024
    msec.
    START
    END
    CM13
    CM41 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 84
    Revision 2.0
    SYSTEM SPEED DIALING
    PROGRAMMING
     
    DESCRIPTION DATA
    Assign Service Restriction Class A to each 
    station. •  YY = 02
    (1) X-XXXX (Station No.) 
    (2) XX
     XX
    *a: Service Restriction Class (A) 00-
    15
    Assign this service to Service Restriction 
    Class A assigned by CM12 YY = 02.•  YY = 06 (System Speed Dialing) 
    (1)  XX (Service Rest. Class A assigned by 
    CM12 YY = 02) 
    (2)  1 : To be allowed
    Assign the Access Code for System Speed Di-
    aling.•  Y = 0-3 (Numbering Plan Group 0-3) 
    (1)  X-XXX: Access Code (##) 
    (2)  067 (System Speed Dialing) 
    Assign an access key for System Speed Dial-
    ing to the D
    terms, as needed. •  YY = 00
    (1)  Primary Extension No. +   + key No. 
    (2) F0067: System Speed Dialing origina-
    tion (For 300 numbers) 
    F0068: System Speed Dialing origina-
    tion (For 1000 numbers) 
    START
    CM12
    CM15
    A
    CM20
    CM90
    *a
    , 
    						
    							ND-45670 (E) CHAPTER 2
    Page 385
    Revision 2.0
    SYSTEM SPEED DIALING
    DESCRIPTION DATA
    Assign the memory block for System Speed 
    Dialing. 300 memory slots are available per 
    system. The number of slots available for each 
    Tenant is also 300. Note that the memory 
    blocks for Hot Line-Outside and Route Ad-
    vance (from Tie Line to C.O. Line) are includ-
    ed in 300 memory slots.
    Abbreviated Call Codes required for access-
    ing this feature are automatically given to each 
    Tenant as shown in the following example. (1)  00-63 (For stations within the Tenant 00-
    63) 
    64 (For ATTCON) 
    (2) XXX
     XXX Note
    *a: First Memory/Slot No. in Block. 
    (000-299) 
    *b: Number of Slots to be allocated in 
    Block. (001-300) 
    For example, to provide 20 memory slots
    starting at Slot 60: Data: 060020
    Assign the number to be called to the Memory 
    Slot Number allocated by CM71. (1)  Memory Slot No. (000-299) 
    (2)  Stored Number (Max. 26 digits) 
    Stored Number: 
    Outgoing Access Code (Max. 2 digits) +
     + Stored Number (Max. 26 digits) 
    To set a pause into the Stored No., enter
    “C” (Fixed pause = 1.5 sec) or “D” (Pro-
    grammable pause specified by CM41-38)
    after desired digits (more than 2 digits). 
    Specify System Speed Dialing security. 
    (Stored number displays on Multiline Termi-
    nal for an outgoing call by System Speed Di-
    aling.) 
    Specify Toll Restriction for an outgoing call 
    by System Speed Dialing, if required. (1) 043 
    (2)  0/1 : Not to be displayed/To be dis-
    played. 
    (1) 044 
    (2)  0/1 : Not to be provided/To be provid-
    ed. 
    CM71
    A
    CM72
    END
    CM08
    TENANT 00
    SLOT 000
    SLOT 019 20
    MEMORY
    SLOTS00
    19
    ABBREVIATED
    CODES
    TENANT 01
    SLOT 020
    SLOT 034 15
    MEMORY
    SLOTS00
    14
    ABBREVIATED
    CODES
    Note:By loading the Resident System Program, the following data is assigned for Tenant 00.
    *a *b
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 86
    Revision 2.0
    SYSTEM SPEED DIALING
    To use the 1000 Slot Memory Block Number (0-3) for Station Speed Dialing as the Memory Block for System Speed
    Dialing, add the following programming.
    DESCRIPTION DATA
    Specify the 1000-Slot Memory Block Number 
    0-3.(1)  112: 1000-Slot Memory Block No.0 
    (2)  0/1 : Available/Not Available
    (1)  111: 1000-Slot Memory Block No.1 
    (2)  0/1 : Available/Not Available
    (1)  176: 1000-Slot Memory Block No.2 
    (2)  0/1 : Available/Not Available
    (1)  110: 1000-Slot Memory Block No.3 
    (2)  0/1 : Available/Not Available
    Specify whether 1000-Slot Memory Block 
    has 26-digits or 16-digits memory buffers.
    Note:When CM08-252 is assigned as 0,
    only 3000 Station Speed Dialing
    numbers can be assigned, and 1000-
    Slot Memory Block No. 0-2 contains
    26-digits memory buffers. When
    CM08-252 is assigned as 1, 4000
    Station Speed Dialing numbers can
    be assigned, and 1000-Slot Memory
    Block No. 0-3 contains 16-digits
    memory buffers.(1) 252 
    (2) 0/1 : 26/16-digits 
    Assign the Access Code for System Speed Di-
    aling.•  Y = 0-3 (Numbering Plan Group 0-3) 
    (1)  X-XXX (Access Code) 
    (2)  A52: 1000-Slot Memory Block No.0 
    A51: 1000-Slot Memory Block No.1
    068:  1000-Slot Memory Block No.2
    A50: 1000-Slot Memory Block No.3
    START
    CM08
    A
    CM20 
    						
    							ND-45670 (E) CHAPTER 2
    Page 387
    Revision 2.0
    SYSTEM SPEED DIALING
    DESCRIPTION DATA
    Assign the stored number to each Memory 
    Slot Number.(1) X XXX (Memory Slot No.) 
    *a: 1000-Slot Memory Block Number 
    (0-3)
    *b: 000-999 
    (2)  Stored No. (Max. 16/26 digits) Setting
    Method: Outgoing Call Access Code 
    (Max.2 digits) +   + Stored 
    No. (Max. 16/26 digits) 
    To set a pause into the stored No., enter “C” 
    (Fixed Pause = 1.5 sec) or “D” (Programma-
    ble Pause specified by CM41-38) after desired 
    digits.CM74
    A
    END
    *a *b
    , 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 88
    Revision 2.0
    TENANT SERVICE
    PROGRAMMING 
    DESCRIPTION DATA
    Assign a Tenant No. to each station. •  YY = 04
    (1) X-XXXX (Station No.) 
    (2)  00 -63 (Tenant No.) 
    Assign a Tenant No. to each trunk. •  YY = 01
    (1) 000-255 (Trunk No.) 
    (2)  00 -63 (Tenant No.) 
    Assign a Numbering Plan Group No. to each 
    Tenant. (1)  00-63 (Tenant No.) 
    (2)  710-713 (Numbering Plan Group 0-3) 
    Assign the required access codes for each 
    Numbering Plan Group. To provide a trunk 
    route for each Tenant, assign Tenant Block 00-
    23 to the desired Trunk Route access code. 
    Note:Refer to the Command Manual for
    the Resident System Program. •  Y = 0-3 (Numbering Plan Group 0-3) 
    (1)  X-XXX (Access Code) 
    Note
    (2) 000-099 
    801-811 
    A00-A52 
    100-163 
    300-323 (Tenant Block 00-23) 
    When Tenant Block 00-23 is assigned by 
    CM20, assign a trunk route and Tenant No. to 
    the Tenant Block. •  YY = 00-23 (Tenant Block 00-23) 
    (1)  00-63 (Tenant No.) 
    (2)  100-163 (Trunk Route 00-63) 
    START
    CM12
    CM30
    A
    CM29
    CM20
    CM23 
    						
    							ND-45670 (E) CHAPTER 2
    Page 389
    Revision 2.0
    TENANT SERVICE
    DESCRIPTION DATA
    To provide external keys for the Day/Night 
    mode changeover or the Class of Service 
    changeover, assign a Tenant No. to each cir-
    cuit No. on the PN-DK00 card. •  YY = 00 
    (1) XX
     X 
    *a: Card No. (00-63) for PN-DK00 as-
    signed by CM10 (E900-E963) 
    *b: Circuit No. (0-7) 
    (2)  00-63 (Tenant No.) 
    Specify the Tenants to be handled by each 
    SN610 ATTCON Group. •  Y = 0-3 (ATTCON Group 0-3 assigned 
    by CM60 YY = 00) 
    (1)  00-63 (Tenant No.) 
    (2)  0/1 : To be handled/Not to be handled
    Specify whether Inter-Tenant connection is 
    available for station-to-station calling, incom-
    ing call termination and TAS answer.•  Y = 0 (TAS Answer) 
    (1) XX
     XX
    *a: Tenant No. of TAS Answer Station 
    *b: Tenant No. of Trunk 
    (2)  0/1 : Allowed/Restricted 
    •  Y = 1 (Station to Station Calling) 
    (1) XX
     XX 
    *a: Tenant No. of Calling Station 
    *b: Tenant No. of Called Station
    (2) 0/1 : Restricted/Allowed 
    •  Y = 2 (Incoming Call Termination) 
    (1) XX
     XX
    *a: Tenant No. of Called Station
    *b: Tenant No. of Trunk 
    (2) 0/1 : Restricted/Allowed 
    CM61
    A
    CM63
    END
    CM62
    *a *b
    INITIAL
    *a *b
    *a *b
    *a *b 
    						
    							CHAPTER 2 ND-45670 (E)
    Pag e 3 90
    Revision 2.0
    TIE LINE TANDEM SWITCHING
    PROGRAMMING 
    HARDWARE REQUIRED 
    Tie Line Trunk Card (PN-2ODT) 
    DESCRIPTION DATA
    Specify the combination of Trunk Routes al-
    lowing the Tandem connection. The incoming 
    trunk route must provide a release signal for 
    the Tandem Connection. (See CM35 YY = 05) (1) XX XX
    *a: 00-63 (Incoming Trunk Route) 
    *b: 00-63 (Outgoing Trunk Route) 
    (2)  0/1 : Allowed/Restricted
    START
    END
    CM36*a *b 
    						
    							ND-45670 (E) CHAPTER 2
    Page 391
    Revision 2.0
    TIMED QUEUE
    PROGRAMMING
    HARDWARE REQUIRED
    ETJ-8-1/ETJ-10DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/PN-4DLCA card.
    DESCRIPTION DATA
    Specify the timer data for this feature.
    If no data is set, the following data is applied:
    • Number of Call Attempts: 3 times
    • Interval Time of Call Attempt: 120 sec. -
    124 sec.
    • Duration of Calling: 28 sec. -32 sec.•  Y = 0
    (1)  35 (Number of Times of Call Attempt)
    (2)  01-07: Once-7 times
     
    (1)  36 (Interval time of Call Attempt)
    (2)  11-31: 44 -124 sec. in 4 sec. increments
     
    (1)  37 (Duration of Calling)
    (2)  05-31: 20-124 sec. in 4 sec. increments
    Assign the Call Back feature to the required 
    key on the Multiline Terminals, as required.•  YY = 00
    (1)  Primary Extension No. +   + Key No.
    (2) F0004
    START
    END
    CM41
    CM90
    , 
    						
    All NEC manuals Comments (0)