    							3 Upgrading and Updating SystemsHow To Use This ChapterThis chapter provides step-by-step procedures for upgrading and updating a Series 6
    Model 
    70. Additional information is also located in the VoiceMemo Reference and
    Conjpration Manual and the Centigram Series G Technical Reference Manual.A task list and Centigram Procedures 
    (CPs) describing upgrading and updating
    procedures are located at the end of this chapter. The task list identifies two
    procedural levels of 
    CPs: a high-level CP and a low-level CP. A high-level CP
    provides instructions on how to do overall tasks, such as installing a server. A 
    low-level CP provides instructions on more specific tasks, such as how to install a line
    card.Readers familiar with Centigram servers can use the 
    CPs as a checklist if desired,
    while readers new to Centigram servers can use 
    CPs for step-by-step instructions.
    After gaining experience with this documentation, you can find your own innovative
    way of using the task list.One possible approach on how to use the task list is
    provided below:
    Using the Task listSelect from the task list the title of the task that you want to perform and note its
    high-level CP number. Flip through the 
    CPs in this chapter until you find the
    correct CP number. Follow the instructions given in the CP.
    A reference column in each CP contains pointers, when necessary, to supplemental
    information such as another procedure, a technical reference in the Centigram
    Series G Technical Reference Manuab another manual, or menu maps. Use the tabsincluded with this binder to find referenced supplemental information that is located
    within this manual.
    If you need to interrupt a CP and seek reference information, first mark the CP with
    your bookmark or otherwise note down where you are in the CP. After you are
    finished with the reference information, return to the CP and continue to execute the
    steps where you left off.
    3-1 
    						
    							Upgrade and Update Task list
    Page 1 of 1
    VoiceMemo Release 6.OA and later
    TaskProcedure
    Upgrading and Updating Systems
    ORline System Software Update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cl? 6483
    InstallOptional Feature WithSystem Online...........................................Cl?5402
    Perform anOfflinePrompts
    Update........................................................
    Cl?6262
    Perform
    anOfflineSoftwareUpdate........................................................CP6263
    Perform an Online Increase
    SystemHours...............................................CP702 1
    r.Note:
    Procedures for building the customer database are in the
    VoiceMemo Reference and Confguration Manual.For additional information, refer to the Centigram Series 
    6
    Technical Reference Manual and the System ImplementationGuide. For detailed information about optional features, refer to
    the respective optional feature manual.
    Updates to procedures and the Model 70 are issued to the field in
    Centigram’s Notices to Installers. You should add them to this
    guide, as appropriate.For questions, contact TAC before starting any of these
    procedures. Be sure the following tasks have been completed
    before attempting any of these procedures.
    lSystem is stable and free of errors and corruption
    lAll system backups have been performed 
    						
    							cp 5402
    Install Optional Feature With System Online
    Page 1 of 2
    VoiceMemo Release 6.OA and later
    The procedure describes how to install an optional feature with the system online. Be
    sure the Optional Feature Diskette(s) and the Module Enable Diskette contain the serial
    number(s) for all disk(s) in the system.
    Note:The serial number on the OneView Optional Feature diskette must match the
    serial number of the hard disk on which 
    OneView is being installed.If you
    receive an error message about an incorrect serial number, contact your
    support organization.CAUTION!
    If you are loading a revision support disk (RSD), do it after
    completion of this procedure.Loading the RSD first, 
    conld create an
    incorrect configuration.
    StepReference
    1.Reach the System Maintenance Menu, then go to the System Maintenance
    Additional Options Menu.
    2.Select the Add Optional Feature(s) program.
    Select:(A) Add Optional Feature(s)
    PTU~PL Enter Y to add optional features, N to stop:
    Response: Y for Yes.
    3.Install the optional feature.
    Prompt: Insert @tional Featurefloppy disk in the floppy
    drive.
    Enter any key when ready:Response: Insert the Optional Feature diskette, then press Enter.
    4.
    sAfter you have installed the Optional Feature software, the system asks if you want
    to install another optional feature.
    Prompt: Do you want to install another optional feature?Response: Y to install another optional feature and continue from step 
    3,N if you are done installing optional features.
    The system automatically edits and saves the configuration files, then returns to theAdditional Options Menu.
    5.Exit the VoiceMemo Configuration Offline Menu. You see the following prompt:
    Prompt: Wait for message waiting queues to be empty?
    Response: N to continue.
    Clenu Map 12
    Doe. Rev. A 
    						
    							Cl? 5402
    Page 2 of 2VoiceMemo Release 6.OA and later
    StepReference
    6.The following prompt appears:
    Prompt: Wait for paging queues to be empty?Response: N to continue.
    7.Exit to the VoiceMemo Configuration - Main Menu, then go to the VoiceMemoConfiguration 
    - Offline Menu.
    8.Duplicate the active configuration.
    Select(B) Duplicate Active Configuration
    9.Exit to the VoiceMemo Configuration -Main Menu and activate the configurat?on.
    Select:(A) Activate Configuration
    tienu Map 2 
    						
    							cp 6262Perform an Offline Prompts Update
    Page 1 of 3
    VoiceMemo Release 6.OA and later
    This procedure describes the offline process of updating the prompts on the Model 120
    or Model 70.
    FOR THE MODEL 120 AND MODEL 
    70 ONLY: Some system prompts in this
    procedure may contain generic references to other multiple-module Centigram Series 6
    products. In such cases, shaded areas indicate a difference in operations for the Model
    120 and Model 70. The Model 120 and Model 70 are equivalent to “one module”
    servers. When asked for the number of the host or module, always enter “1” or “a”.
    This procedure applies to servers using either SCSI or IDE hard disks.
    StepWARNING!
    This procedure requires that you shut down the server, 
    rezulting in an
    interruption to call processing.Centigram recommends that you
    nerform this 
    nrocedure durine neriods of low call traffic.
    1.Reach the System Maintenance Menu.
    2.
    Execute a system shutdown.
    Select:(S) System Shutdown
    Prompt: WARNING! !This will terminate call
    processing.W-seeshutdownif you really
    want to do this
    Response: shutdown
    3.Specify all modules are to be shut down.
    Prompt: modules to shutdownResponse: Enter the a for all modules.
    lThe server displays the status of each line of the specified modules as “idle,”
    “active” or “stopped,” and updates the status every minute until all lines are
    stopped. The server stops any calls still in progress after five minutes.
    4.If you are executing a system shutdown, wait for the message- waiting queue to clear.
    If you are executing a module shutdown on a multi-module system, do not wait for
    the message waiting queue to clear.
    Prompt: Wait for message waiting queues to be empty?Response: Y to wait for the queue to clear,
    N to continue immediately with the shutdown.
    Rejrence
    tienu Map I
    Dac. RN. A 
    						
    							SteDReference
    CP 6262
    Page 2 of 3
    VoiceMemo Release 6.OA and later
    5.Decide if you want to wait for paging queues to clear.
    prompt: Wait for paging queues to be empty?
    Response: Y to wait for the queue to clear,
    N to continue immediately with the shutdown.
    The following messages are then displayed:
    Message Indicator Request Queue Lengths
    active:0untried:0retrying:0calls expected:0
    Paging Request Queue Lengths
    I,
    active:0untried:0retrying:0calls expected:0
    6.Specify if changes to the status of each module are to be made.
    f’rompt: Enable or Disable Modules?
    Response: Y
    7.A chart with the status of each module is displayed and then the Module
    Maintenance Menu is displayed:
    *** Module Status ***
    +-------+-------+-------+------+
    I1 12 I3 I4 I+-------+-------+-------f-------f1  
    ENA 1  - 1  - 1  - 1f-------+-------+-------+-------+
    ENA=> Module is Enabled
    DIS=> Module is Disabled
    - => Module is not configured
    MODULE MAINTENANCE MENU
    -----------------------
    _------------_---------
    (D) DISABLE a module
    (E) ENABLE a module
    (X) Exit
    8.Change the status of all modules to disabled, changing the status of the module the
    console is attached to last.
    Select:(D) DISABLE a module
    Prompt: Which Module?
    Response: a
    Prompt: type disableto confirm your request:
    Response: disable
    i
    Dot. kv. A
    l- 
    						
    							Cl6262Page 3 of 3
    VoiceMemo Release 6.OA and later
    StepReference9.The server automatically boots to the Maintenance From Hard Disk Menu. Select
    the prompts.add program.
    Prompt: Enter one of the names:
    Response: prompts-add
    10. Load the prompts diskettes.Prompt:Insert the 1st diskette containing the prompts
    and press return
    Response: Insert Prompts Disk 1 then press Enter to continue.
    h,pt, Wait until drive light is out, insert language
    disc 
    #l,hit CR when ready.
    Response:Press Enter again to continue.
    11. The prompts are copied to multiple hard disks, as applicable. The process can take
    many minutes, depending on the number of hard disks. The server then requests
    the remaining diskettes.
    Prompt: Working...
    Wait until drive light goes out, insert language
    disc 
    #2, hit CR when ready.
    Response:Insert the specified diskette then press Enter to continue.
    12. The server reads from the floppy disk drive and prompts for each of the remaining
    diskettes.Insert the remaining diskettes and press Enter when prompted.
    13. When the prompts diskettes are complete, the 
    semer displays the number of speech
    blocks that have been used for the system prompts.
    prompt: For this prompt partition (vid 1):
    xxxx directory entries allocated out of m available
    = pointer sectors allocated out of )(xxx available
    xxxx speech blocks allocated out of xxxxxavailable
    Starting up processes, please wait...
    14. Enable all modules.
    Prompt:Enter one of the names:
    Response: hoststatus
    Select:(E) ENABLE a module
    Prompt Which Module?
    Response: aThe server automatically resets and returns to normal operation.
    Dot. Rev. A 
    						
    							cp 6263Perform an Offline 
    Sofbwre UpdatePage 1 of 5VoiceMemo Release 6.OA and later
    This procedure describes how to update the software on a Model 120 or Model 70. It
    applies only to Release 6.0 and above. To update software, the server must be shut
    down and disabled using the procedure described in Cl? 6268.
    FOR THE MODEL 120 AND MODEL 70 ONLY: Some system prompts in this
    procedure may contain generic references to other multiple-module Centigram Series 6
    products. In such cases, shaded areas indicate a difference in operations for the Model
    120 and Model 70. The Model 
    120 and Model 70 are equivalent to “one module”
    servers. When asked for the number of the host or module, always enter “1 or “a.This procedure applies to servers using either SCSI or IDE hard disks.
    StepReference
    1.Insert the Floppy Boot Diskette. Press the Reset button or turn on the p.ower to the
    system. The system boots from the floppy drive. The server displays the self test
    results.
    2.The server reads from the floppy disk, then requests the service diskette.
    J+-ompt: Insert floppy SERVICE 6.00 and hit return
    Response: Insert the diskette, then press Enter.
    3.The server reads from the floppy disk, and asks which process you want to execute.
    Prompt: Enter one of the names:
    Response: update 
    						
    							CP 6263
    Page 2 of 5VoiceMemo Release 6.OA and later
    step4.The server reads from the floppy disk and issues a warning about the pending
    process.
    J’rompt: WARNING! !******X*** UPDATE PROGRAM t*********UPDATE program ONLY updates the system
    software files.
    Data such as accounts,
    and speech will remain unchanged (prompts
    cleared later on UPDATE program only
    if told so).
    Any billing data files
    constructed via the 
    (G)ather command may
    be incompatible with the new release. To be,
    sure you will not lose billing
    information,
    run a billing report before doing
    this update.
    =====> The SYSTEM LOGFILE and CDR
    information will be lost. To save 
     this information, obtain
    hard copy
    outputs BEFORE this update 
    
    						
    							CP 6263Page 3 of 5
    VoiceMemo Release 6.OA and later
    Step
    6.If an old format of billing data is found on the server, the following message is
    displayed:
    Prompt: Old format of billing report data found.
    This data
    must be deleted before proceeding with the software
    update.To run any billing reports from the last
    gather,reboot the system now.Proceeding from here
    will NOT result in any lost billing data provided
    you have already run all needed reports from the
    last gather. Note:
    Future updates will not require
    report files to be deleted.
    update,
    To proceed with the ,,
    enter Y to delete report data:
    To proceed, please enter a Y, OR TO 
    ABORT,F?EBOOT
    THE? SYSTEM.
    Response: Y
    7.The server continues, then requests the first software diskette.
    The first two lines of the following prompt are seen only if the server located billing
    information.
    Prompt: Deleting 4:/bill_data...
    Deleting 4:/prev_data...
    When drive light goes out insert disk 1 and
    press return
    Response: Insert the specified diskette, then press Enter.
    8.The server requests the remaining diskettes. Each diskette takes approximately 5
    minutes.
    Prompt: When drive light goes out insert disk 2 and
    press return
    Response: Insert the specified diskette, then press Enter.
    s
    9.After all software disks have been loaded, load the prompts.
    Prompk WARNING! !ALL prompts will be cleared from
    aplicable partition(s).
    If you want to clear the
    prompts, type clearIf you want to do nothing and
    continue hit 
    
    Response: clear, if new prompts are to be loaded.Press Enter to skip this process and continue at step 
    12. .
    10. The server clears all prompts on the server, then requests the first diskette.
    Prompt: Clearing all prompts...All prompt speech cleared
    Insert Prompt Diskette 1 in the floppy drive.
    mter Y when ready, or N to quit:Response: Insert Prompts Diskette Number 1 then Y to continue.