Home
>
Mitel
>
Communications System
>
Mitel Voice Processing Solutions Installation And Service Manual
Mitel Voice Processing Solutions Installation And Service Manual
Have a look at the manual Mitel Voice Processing Solutions Installation And Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
: : CP 7029 Diagnose a Disk With System Online Page 1 of 1 VoiceMemo Release 6.OA and later This procedure describes how to run the diagnose program to check the hard disk while the system is online processing calls. StepReference 1.Reach the System Maintenance Menu, then go to the Hard Disk Utilities Menu. 2.Specify the disk(s) to be tested. Select:(D) Diagnose a disk Prompt:Enter the hard disk id[bus:scsiId] to test, or A for all,or Q to quit: Response:Enter a if you want to test all the disks in the system, otherwise enter the bus and two-digit SCSI ID number of the disk to be tested.8. vlenu Map 8 3.Identify which tests are to be executed. Prompt: All options default to Y: Perform Controller Test? [Y/N] Response: Y or press Enter to perform the test,N to skip the test. Prompt Perform Sequential Test? [Y/N] Response: Y or press Enter to perform the test,N to skip the test. PrompL Perform Random Seek Test? [Y/N] Response: Y or press Enter to perform the test, N to skip the test. Prompt: Perform Spiral Seek Test? [Y/N] Response: Y or press Enter to perform the test, N to skip the test. 4. .If any test does not pass, contact your Centigram Distributor or Centigram TAC. Doe. Rev. A
CP 7030Run Diagnose From Hard DiskPage 1 of 2 VoiceMemo Release 6.OA and later This procedure describes how to run the hard disk diagnose program from the Maintenance From Hard Disk Menu. It is assumed the module running the test has been shut down and disabled using the process described in Cl? 6268. WARNING!This version of the diagnose program requires one module to be removed from normal operation.Centigram recommends that this process be run during periods of low call traflic.If possible, the online version of this program should be run from the Hard Disk Utilities Menu so there is not a loss of call processing capabilities. See CP 7029 for the online instructions. Step 1.Boot the module to the Maintenance From Hard Drive Menu. P?WYZpt:Run MAINTENANCE from Hard Drive? Response: y2.Start the Diagnose program and identify the disk(s) to be tested. Select:diagnose Prompt: Enter the hard disk id[bus:scsiIdl to test, or A for all, or Q to quit: Response:a if you want to test all the disks in the system, otherwise enter the bus and two-digit SCSI ID numbers, separated by a colon, of the disk to be tested. Reference
cl? 7030Page 2 of 2 VoiceMemo Release 6.OA and later Step 3.Identify which tests are to be executed. Prompt: All options default to Y: Perform Controller Test? [Y/N] Response: Y or press Enter to perform the test,N to skip the test. Prompt: Perform Sequential Test? Response: Y or press Enter to perform the test,N to skip the test. Y/N1 prompt: Perform Random Seek Test? ‘Response: Y or press Enter to perform the test,N to skip the test. [Y/N1 Prompt Perform Spiral Seek Test? Response: Y or press Enter to perform the test,N to skip the test. [Y/N14.If any test does not pass, contact your Centigram Distributor or Centigram TAC. 5.If all tests pass, enable the module being tested. Select:host.status Prompt: Module Status Menu Select:(E) ENABLE a module Prompt.- Input a module id in the following range:n n n n Which Module?Response: Enter the number(s) of the module(s) to enable. sThe module(s) automatically resets and returns to normal operation. Reference
cl? 703 1Run Diagnose From Diskette Page 1 of 2 VoiceMemo Release 6.OA and later This procedure describes how to run the hard disk diagnose program from the Diagnostic Diskette. It is assumed the system has been shut down and all modules disabled using the process described in CP 6268. WARNING! This version of the diagnose program requires the system to be removed from normal operation.Centigram recommends that this process be run during periods of low c& traffic. If possible, you should run the online version of this program from the Hard Disk Utilities Menu, so you do not lose processing capal+ies. See CP 7029 for the online instructions. Step 1.Insert the Diagnostic Diskette in the floppy drive and reset the server. 2.Start the sewer from the hard disk, then run commands from the floppy diskette. Prompt: IPLlOO: Boot system from (Hard disk, Floppy) [H/F]?Response: Press Enter. Prompt: Run commands from floppy? Response: Y 3.The server reads from the floppy disk and asks which process is to be executed. Prompt: Enter one of the names: Response: diagnose 4.Identify the disk(s) to be tested. Prompt: Enter the hard disk id[bus:scsiId] to test, or A for all,or Q to quit: Response:a if you want to test all the disks in the system, otherwise enter the busand two-digit SCSI ID numbers, separated by a colon, of the disk to be tested. Reference Dot. Rev. A
a? 7031Page 2 of 2 VoiceMemo Release 6.OA and later step 5.Identify which tests are to be executed. Prompt: All options default to ‘Y’: Perform Controller Test? [Y/N]Response: Y or press Enter to perform the test, N to skip the test. Prompt: Perform Sequential Test? [Y/N] Response: Y or press Enter to perform the test,N to skip the test. Prompt: Perform Random Seek Test? [Y/N]Response: Y or press Enter to perform the test, N to skip the test. Prompt: Perform Spiral Seek Test? [Y/N]Response: Y or press Enter to perform the test, N to skip the test. 6.If any test does not pass, contact your Centigram Distributor or Centigram TAC. 7.If all tests pass, enable the modules. Select:host.status Prompt: Module Status Menu Select:(E) ENABLE a module Prompt:Input a module id in the following range:n n n n Which Module?Response: Enter the number(s) of the module(s) to enable. The module(s) automatically resets and returns to normal operation. Reference Dot. Rev. A
Appendix- Public Telecommunications Network ConnectionThis appendix describes supplemental product information that you can use to ensure that your Series 6 Model 70 is correctly installed and complies with various requirements and standards. Refer to the regulatory compliance statements at the front of this manual for other requirements. Model 70 ConnectionsThe following paragraphs describe the requirements for connecting-the Model 70 to the Public Telecommunications Network (PTN)... Shielded CablesYou must supply and use shielded cables when making connections to any of the following ports: l Console ports l Serial ports lText-to-Speech (TTS) card ports l MESA-Net ports lDisk drive ports A-l
Jack Types A-2Public Telecommunications Network ConnectionUse standard modular telephone jack types when connecting to the telephone network. Use RJ- 11 C or RJ-2 1X f or me cards in a two-wire loop start or DID 1’configuration. Use RJ-2EX or RJ-1CX jacks for E & M operation. Use an RJ-11 C jack for the modem port. Refer to the following table for facility interface codes, port identifications, service order codes, RENs, and network jacks, by port type. Registration Status2-wire loop start2-wire loop startE&M MTSlVi’ATSFacility Interface Code 02LS2 02LS2 TLllE or TLllMPort Designation E line card or AT line card, ports O-31Modem E line card or AT line card, ports O-31Service Order Code 9.OF 9.OF 9.OFREN 0.2A 0.3A O.OBNetwork Jacks RJ-11C or RJ-21X RJ-11C RJ-2EX or RJ-1CXFor fax cards, the REN is O.OB and the network jack is RJ-1 1C or RJ-21X. Connectors and LoadsThe Model 70 is connected to the telecommunications network via telephone line cords that terminate in CA1 1A connectors for loop circuits, or CA2EA connectors for E & M circuits. The Load Number (LN), assigned to each terminal device, denotes the percentage of the total load to be connected to a telephone loop used by the device and prevents overloading.The termination on a loop may consist of any combination of devices, but the total of the Load Numbers of all the devices cannot exceed 100. The LN for a Model 70 is 100. No other terminal devices can share the same telephone line while the Model 70 is connected.
Public Telecommunications Network ConnectionResponsibilities of the Equipment OwnerThe following paragraphs describe the responsibilities of the equipment owner, subject to the rights of the telephone company and government regulations. Incidence of HarmIf your equipment harms the telephone network, the telephone company can discontinue your service temporarily.If possible, the company will notify you in advance. If this is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC. Rights of the Telephone CompanyThe telephone company may make changes in its facilities, eiuipment, operations, or procedures, which could affect the proper functioning of your equipment.If this occurs, you will be notified in advance so you can maintain uninterrupted telephone service. Coin Service or Party line UseThis equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. A-3
List of Centigram Procedures Page 1 of 3 Procedure Number CIJ1340 CP 5303 CP5304 CP 5313 CP5314 Cl?5402 CP 5412 cl? 5413 CP 5414 CP 5415 CP5701 CP5703 CP 5704 CP6201 CP6215 CP6216 Cl?6220 CP6221 CP6222 CP6224 CP6258 Chapter NumberTitle CPs CalledCalled By 2Run a System Information ReportCP6590, Cl?6483 5Recover a Lost Console Passcode 5View or Edit History FileCP6483 5View Hard Disk Operational Parameters 5Change Module Status From Hard DiskCP6281 CP6282 3Install Optional Feature With System5CP6483 Online 5Back Up a Class of Service 5Restore a Class of Service 5Set the System Time and Date 5Set the Site Name, Banner, and Code 5Run Veri@ With System OfflineCP6483 5Do a Floppy BackupCP6592 CP6483 5Do a System Restore (system.restore) 2Test Basic Telephony FunctionsCP6220CP6590 CP6262 2Install PrinterCP6590 2Install ConsoleCP6590 4Remove/Install Line CardCl?6224 4Remove/Install Hard DiskCl?6224CP628 1CP6592CP6282 CP6592 4Remove/Install Floppy Disk DriveCP6224 4Remove/Install Cabinet CoverCP6220 CP6221 CP6222 CP6281 CP6282 CP6284 CP6592 2Check Installation QualityCP6590
List of Centigram Procedures Page 2 of 3ProcedureChapter NumberNumberTitle CPs CalledCalled ByCP6261 2Connect the Telephone LinesCl?6201 Cl?6590 CP6262 3Perform an Offline Prompts UpdateCP6201 CP6263 3Perform an Offline Software UpdateCP6268CP6483 CP 6267 5Do a System Reload (system.reload)CP6268 5Shut Down a SystemCP5303 CP5704 CP6263 *,CP628 1CP6282 CP6483 CP6270 2Install ModemCP6590 CP6281 5Redundant Disk AdditionCP6221CP6282 (make.redundant)CP6224 CP6268 CP6282 CP7015 CP6282 5Disk Addition (add.disk)CP6221 CP6224 CP6268 CP 628 1 CP7015 CP 702 1CP6283 5Online Disk Replacement (RedundantCP6221 Systems)CP6224 CP6268 CP7015 CP62842Install Redundant Hard DiskCP6224 CP6483 3Offline System Software UpdateCP1340, CP5304, CP5402, CP5701, CP5703, CP6263, CP6268, CP700 1