Configure Fujitsu Starlog IntegrationPage 1 of 3VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration feature to work with the Fujitsu Starlog PBX. Refer to the appendixes for reference information about this integration. There are two sections to installing this integration: installing and configuring the VoiceMemo software, and configuring the Fujitsu Starlog PBX. Refer to your Starlogdocumentation for help when configuring the PBX, if necessary. SCP @ED Configure the VoiceMemoSystem 1.Install the Enhanced In-band Integration optional feature diskette. 2.Define a line group for the integration. 8.3.Assign the Enhanced In-Band Integration application to the line group. 4.Select the Starlog integration application for the line group. 5.If your VoiceMemo system has Release 5.03 software, set the number of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 software, the system automatically configures the required number of tasks. 6.Refer to the Task List in your VoiceMemo Reference and Conjgwation Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery lConfigure for Transfer to System Attendant lDefine an Administrator’s Mailbox lDefine an Attendant’s Mailbox lConfigure Passcode Parameters l Enable Dial-by-Name lSet a default language for the line group lEnable multiple messages for outside callers Reference 1P 5402 1P 6028 1P 7006 1P 7010 1P 7016
GP 505 Page 2 of 3VoiceMemo Release 5.03 and later Step 7.Set the following phone line exceptions for each line in the line group: Exception Value Descriotion3 2 Dial Tone Detect Time 9 20 Ringing Timeout 25 Y Enable DTMF Column 3 14040 Loop Break Detect Time 14490 In-ring Off Time 148 3In-ring On Time Low 152 1500In-ring Minimum Power 1648 DTMF Output Duration 1762 DTMF Output Level Note:If the VoiceMemo system has the Receptionist II optional feature, the Ringing Timeout (line exception 9) must be 3 seconds kss than the switch’s Ring No Answer timer. 8.If desired, add feature bit 017 to users’ FCOS’s to reduce the amount of time that the VoiceMemo system waits before clearing a port after an undetected caller hangup. 9.If desired, add feature bits 161 and 162 to users’ FCOS’s, and have users activate their conditional greetings. 10. If your AIP VoiceMemo system has the Receptionist II optional feature installed, enable it from the online menus, then define the extension numbers for the Receptionist II ports. Set the Receptionist Dial String to +#++. 11. Create a second line group and configure it for DTMF-to-PBX message waiting, or configure a serial port for RS-232 message waiting. See the WceMemo Refeerence and C&j&ration Manualfor details.Set the following line exceptions for DTMF-to-PBX message waiting: ExceptionValue Descrintions 6OffDTMF Detect Enable 164 8DTMF Output Duration 1762DTMF Output Level GD Configure the Fujitsu Starlog PBX 1.Cross-connect phone lines from Starlog PBX 8SLC cards to the VoiceMemo system phone ports. 2.Connect the Starlog and VoiceMemo systems to same ground point. i Dot. Pa. A Reference IP7022 DE’5011DP7023 DP6034 DP 3021
GP 505 Page 3 of 3VoiceMemo Release 5.03 and later Step 3.CMC 102: FLGN 2 15 49 109 110 111 112 136Set the following system parameter flags to the indicated values: Value Descrintion 1OPS ring pattern = station ringing (1s on, 3s off) 1Enable message waiting for all 500/2500 sets 10Send filler digit (0) to VoiceMemo when required 1Enable called party auto-disconnect on hangup 1Enable stutter dial tone if no message waiting lamp 0Set voice mail integration pattern zero (0) 3 or4Set to extension length on PBX; if mixed length, set to 4 1Set standard busy tone*.4.CMC 104: Define a class of service for the VoiceMemo ports. Allow any required trunk group access.Include feature number 87. 5.CMC 104: Include feature number 89 in the classes of service for all VoiceMemo users. 6.CMC 200: Assign a phantom station for use as a VoiceMemo pilot number. Use an easy-to-remember number for this station. 7.CMC 201: Set each message waiting port as an originate-only port (I’2 =2). 8.CMC 204: Set l?3=1 for each VoiceMemo port to disable distinctive ringing. 9.CMC 204: Set P4=1 for each 500/2500 set with a message waiting lamp. 10. CMC 206: Set P4 =l for the VoiceMemo lines that are used for message waiting. Include the ACD pilot if you have placed the VoiceMemo ports in an ACD. 11. CMC 251: Set the trunk directory numbers to all zeros (P3=0000) on all trunks that can reach VoiceMemo.12. CMC 254: Lengthen the duration of DTMF sending to 128 milliseconds as follows: Pl =o-P2= 10 I?3 = 213. CMC 301: Create a circular hunt group that contains all of the phone lines connected to the VoiceMemo system. You must include the message waiting line(s) to allow the message waiting return call to reach the hunt group. 14. CMC 308: Build an ACD group consisting of the phantom pilot and only those lines assigned to the Enhanced In-band Integration. Do not include the message waiting ports. 15. Forward VoiceMemo user telephones to the phantom extension. Reference i Dot. Rev. A
Configure AT&T System 25 IntegrationPage 1 of 1VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the AT&T System 25 PBX. Refer to the appendixes for reference information about this integration. After completing the steps below, you will need to program your switch to pass in-band call information to the AIP VoiceMemo system. Refer to your PBX manual for additional information. SteD 1.Install the Enhanced In-band Integration optional feature diskette. 2.Define a line group for the integration.*. 3.Assign the Enhanced In-Band Integration application to the line group. 4.Select the AT&T System 25 application for the line group. 5.If your VoiceMemo system has Release 5.03 software, set the number of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 software, the system automatically configures the required number of tasks. 6.Refer to the Task List in your VoiceMemo Reference and Configuration Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery lConfigure for Transfer to System Attendant lDefine an Administrator’s Mailbox 0Define an Attendant’s Mailbox l Configure Passcode Parameters- * Enable Dial-by-Name lSet a default language for the line group 0Enable multiple messages for outside callers 7.Exit and save your changes. 8.Configure either RS-232 Message Waiting or DTMF-to-PBX Message Waiting. See your VoiceMemo Rejb-ence and Con..guration Manual for details. 9.Cross-connect phone lines from the System 25 to the VoiceMemo phone ports. 10. Connect the System 25 and VoiceMemo system to same ground point. Reference 1P 5402 1P 6028 1P 7006 1P 7010 1P 7016 tienu Map 13 DP 3021 i Dot. Rev. A
Configure Northern Telecom NorstarIntegrationGP 507Page 1 of 4 VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration feature to work with the Northern Telecom Norstar KSU. Refer to the appendixes for reference information about this integration. There are two sections to installing this integration: installing and configuring the VoiceMemo software, and configuring the Norstar. Refer to your Norstardocumentation for help when configuring the switch, if necessary. Step @D Configure the VoiceMemo System I.Install the Enhanced In-band Integration optional feature. 2.Define a line group for the integration.a.3.Assign the Enhanced In-Band Integration application to the line group. 4.If your VoiceMemo system has Release 5.03 software, set the number of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 sofixare, the system automatically configures the required number of tasks. 5.Select the Norstar template set. 6.Use the Edit Templates option to modify the Data field in templates 2 and 3. The Data field for template 2 must contain the prefix digit used by your switch (if any) and the pilot number of the hunt group of VMI lines.The Data field for template 3 must contain the prefx digit (if any) and “d3”which means to expect a f=ed-lengthextension of three digits. Alternatively, you can use Xl in place of the prefuc digit in the Data field. This causes the VoiceMemo system to ignore one digit. The system still expects a digit (the prefer digit)f rom the Norstar, but it will accept any digit. ReferenceDP5402 DP6028 DP7006 DP7016 Dl?7010 DP7011 Documcnr. kv. A
GP 507 Page 2 of 4VoiceMemo Release 5.03 and latei step I7.Refer to the Task List in your VoiceMemo Reference and Corzfguration Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery lConfigure for Transfer to System Attendant lDefine an Administrator’s Mailbox lDefine an Attendant’s Mailbox l Configure Passcode Parameters * Enable Dial-by-Name lSet a default language for the line group lEnable multiple messages for outside callers 8.Set the following phone line exceptions for each line in the line group: ExceptionValueDescription 2360Flash-hook Time 3224DTMF Receive Debounce Time 16670Interdigit Delay Time 9.If your VoiceMemo system has the Receptionist II optional feature, set the Pre-DN dial string to S+*70 for blind transfers. The Compact and Modular DR2 do not support supervised transfers over the VMI lines. If you have a Norstar DR3 or DR4 and want to use supervised transfer, set the Pre-DN dial string to S+2, set the Connect Dial String to S+*3,* and set the Dial Suing for Return on Called Party Busy or RNA to S+2. See your Receptionist II Manual for details.10. Exit and save your changes. 11. If the systems are near each other, connect the switch and VoiceMemo systems to the same ground point. 12. Configure a line group for DTMF-to-PBX Message Waiting with the following values:Pre-DN On Dial String = S+*lPre-DN Off Dial String = S+#l See your VoiceMemo Reference and Confguration Man&for procedures onconfiguring DTMF-to-PBX Message Waiting. Documcnr. kv. A Reference /lenu Map 13 1P 7022 3P 3021
GP 507 Page 3 of 4VoiceMemo Release 5.03 and later Step GD Configure the Northern Telecom Norstar 1.Install VMI modules for all integration lines as instructed in the Norstar Voice Mail Inte$zce Installation Gzriu’e. Connect lines from the Line Jacks on the VMIs to available telephone ports on the KSU. Connect lines from the Terminal Jacks on the VMIs to line card ports on the VoiceMemo system. Plug in the power supplies for the VMIs. Mount the VMIs on the wall after connecting them to both the KSU and the VoiceMemo system. 2.Install ATAs or additional VMIs for all VoiceMemo system outdial ports, including any used for DTMF-to-PBX message waiting. 3.Use an M7310 or M7324 telephone to determine the feature codes assigned to each VMI.(The KSU automatically assigns feature codes to each VMI and assigns intercom numbers (DNs) to each VMI line.) 4.Use the VMI feature codes to determine the intercom numbers assigned to each VMI line. 5.For Compact DR2 and Modular DR2 systems, ensure that each VMI DN is configured as follows: Under Permissions: Held Line Reminder = YES Full Handsfree =NO Handsfree Answerback =NO Pick Up Group =NO Paging Zone =NO Under Line Access: Intercom line is assigned as the prime line. Reference
GP 507 Page 4 of 4VoiceMemo Release 5.03 and later Step 6.For Modular DR3 and DR4 systems, ensure that each VMI DN is configured as follows: Under Permissions/Capabilities:Set Lock =NONE Full Handsfree =NO Handsfree Answerback =NO Pick Up Group =NO Page Zone = NO Auxiliary Ringer = NO *.Hotline =NO Priority Call =NO Under Line Access: Answer DN = NO Line Pool Access =NO(If a line will be used for outdialing, set to YES.) Two intercom lines are assigned, with one assigned as the prime line. 7.Program the first VMI DN to call forward for both busy and no answer conditions to the second VMI DN. Program the second VMI DN to call forward to the third VMI DN, and so on. Program the last VMI DN to call forward to the first VMI DN. This will ensure an efficient use of ports for both systems. 8.Program any DNs used for message waiting indication to call forward all calls to the first VMI DN in the Enhanced In-band line group.This will allow users to press the message key on their phones and be connected to the Enhanced In-band line group. 9.Program the following translation codes (L = link or flash): sSet message waiting =L*ICancel Message Waiting = L#lCall Transfer = L*70Forward Prefer =6 Disconnect Code =(clear this field) Note:The default Disconnect Code is a dial tone, which means that the Norstar will return dial tone to the VoiceMemo port when a caller hangs up. You may want to set this code to 9 for integration ports without Receptionist II software, or ## for ports with Receptionist II. Both of these codes tell the VoiceMemo system to end a call session. 10. Program all user phones to call forward on both busy and no answer conditions to the first VMI DN. i Documcnr kv. A Reference
Configure AT&T Legend IntegrationGP508Page 1 of 1 VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the AT&T Legend PBX. After completing the steps below, you will need to program your switch to pass in-band call information to the AU? VoiceMemo system.Refer to your PBX manual for additional information. smReference 1.Install the Enhanced In-band Integration optional feature diskette. 2.Define a line group for the integration. 3. Assign the Enhanced In-Band Integration application to the line group. &,4.Select the AT&T Legend application for the line group. 5.If your VoiceMemo system has Release 5.03 software, set the number of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 software, the system automatically configures the required number of tasks. 6.Refer to the Task List in your VoiceMemo Reference and Conjguration Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery lConfigure for Transfer to System Attendant lDefine an Administrator’s Mailbox lDefine an Attendant’s Mailbox lConfigure Passcode Parameters -l Enable Dial-by-Name lSet a default language for the line group lEnable multiple messages for outside callers 7.Exit and save your changes. 8.Configure either RS-232 Message Waiting or DTMF-to-PBX Message Waiting. See your VoiceMemo Reference and Con$guration Manual for details. 9.Cross-connect phone lines from the Legend to the VoiceMemo phone ports. 10. Connect the Legend and VoiceMemo system to same ground point. 1P 5402 3P 6028 1P 7006 3P 7010 DP 7016 Menu Map 13 DP 3021 i Dot. Rev. A
GP 509Configure Northern Telecom MTX IntegrationPage 1 of 1 voiceMemoRelease 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the Northern Telecom MTX switch. After completing the steps below, you will need to program your switch to pass in-band call information to the AIP VoiceMemo system. Refer to your PBX manual for additional information. SteD 1.Install the Enhanced In-band Integration optional feature diskette. 2.Define a line group for the integration. 3. Assign the Enhanced In-Band Integration application to the line group. ., 4.Select the Northern Telecom MTX application for the line group. 5.If your VoiceMemo system has Release 5.03 software, set the number ‘of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 software, the system automatically configures the required number of tasks. 6.Refer to the Task List in your VoiceMemo Reference and Confgwation Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery .Configure for Transfer to System Attendant lDefine an Administrator’s Mailbox lDefine an Attendant’s Mailbox lConfigure Passcode Parameters al Enable Dial-by-Name *Set a default language for the line group lEnable multiple messages for outside callers 7.Exit and save your changes. 8.Configure either RS-232 Message Waiting or DTMF-to-PBX Message Waiting. See your VoiceMemo Reference and Confguration Manual for details. 9.Cross-connect phone lines from the MTX to the VoiceMemo phone ports. 10. Connect the MTX and VoiceMemo system to same ground point. Rejbence II’ 5402 II’ 6028 1P 7006 1P 7010 1P 7016 tienu Map 13 DP 3021 Dot. Rev. A