    							Dual Tl Digital Trunk Connectivity
    1--811Model 70 and Model 
    1201 supports only one digital trunk for a maximum system
    capacity of 24 
    KM voice channels. The Model 120s and the Model 640 module
    each supports up to 60 PCM voice channels between two digital trunk interface
    cards.You assign the slot at the Physical Resource Configuration Menu for the card you are
    configuring.
    Module NumberThe module number is the Series 6 server module in which the digital trunk interface
    card is installed. A four-module Series 6 Model 640 server can support a total
    capacity of 240 PCM voice channels over 16 trunks.(In such 
    ‘a configuration the
    line groups would be configured to use only part of the total number of PCM
    channels 
    - that is fractional Tl - available in each trunk. Refer to “TlConnectivity Features” on page 7.) You assign the slot at the Physical Resource
    Configuration Menu for the card you are configuring.
    Input/Output AddressThe digital trunk interface card can occupy one of two possible AT bus addresses:
    Ox3OOh and Ox2300h where address Ox300h is the default address occupied by card 0
    and 
    Ox2300h is assigned to card 1. These addresses can also be assigned to a
    Smartcard in Model 70 and 
    I201 servers. Before selecting the I/O address, check the
    addresses occupied by these cards if they are present in the affected Series 6 server
    module. If these cards are and either of their addresses are set to the same to which
    the digital trunk interface card, an address conflict exists and bus contention will
    occur. Ensure that each card is set to a unique address. The address selected in the
    Select IO Address Menu must match the address for which the card is physically
    jumpered.
    Note:The digital trunk interface card has jumper positions for setting
    interrupt request levels.
    However, the 
    VoiceMemo application
    polls the hardware to detect status and service the cards and does
    not use hardware interrupt requests.
    You set the card 
    I/O address in the Configuration Menu for Board [DUAL Tll in
    AT slot x.
    SignalingEach channel in the digital trunk interface can be set for one of these four types of
    channel associated signaling according to the requirements of 
    CSUs, channel banks,
    or other related equipment to which the Series 6 server is connected:
    2
    2-14 
    						
    							Dual T1 Digital Trunk Connectivity
    l Loop start
    l Ground start
    lDirect Inward Dial (DID)
    . E&M
    You set the trunk signaling in the Select Trunk Type Menu. The menu has options
    for both analog and digital trunks. However, when you are configuring a digital
    trunk interface card, the configuration manager accepts only the digital trunk
    options.
    Trunk ConfigurationTrunk configuration includes the trunk number, framing format, and coding format.
    Trunk Sequence NumberThe trunk number is the logical number of the trunk, 
    beginningwith trunk number
    0 on trunk card 1. You set the trunk number at the Configuration menu for 
    Tl/ElCarrier at trunk x Menu.
    Framing FormatThe Series 
    G server supports D4 12channel frames and extended superframe (ESF)
    24 channel frames. You select the framing format the trunk uses at the Configure
    Frame Format for Board [DUAL 
    Tl] in AT slot x Trunk y Menu.
    Coding FormatThe Series 6 server supports 
    B8ZS, AM1 (alternate mark inversion) and AM1 with
    ZCS (zero code suppression) coding formats for 
    Tl trunks. You select coding for
    the trunk at the Configure Frame Coding for Board [DUAL 
    Tl] in AT slot x Trunk
    y Menu.
    Clock SynchronizationThe system master clock must be synchronized to the 
    nenvork (that is, a selected Tl
    F&D signal). The digital clock reference can be set to one of the following:
    0Network
    l
    Default
    0Internal (reserved for connections to channel banks)
    The network clock referenceis the 
    I&D signal of a selected Tl trunk. In the case of
    Model 70 and Model 1201, the selected trunk is trunk 0. For Model 
    12OS, selected
    trunk can be 0 or 1. For Model 640, the selected trunk can be 0, 1, 2, or 3 (only one
    trunk can be selected). The default reference is trunk 0.
    The Series 6 server features automatic switchover to a backup clock source if the
    primary fails. However, this feature functions only when both trunks of a Dual 
    TIcard are used and the clock is synchronized to the 
    RxD signal of one of them..
    2-15 
    						
    							Dual T1 Digital Trunk ConnectivityThen, if the trunk to which the clock reference is derived, the Series 
    G server will
    automatically switch over to the second trunk on the Dual 
    Tl card.
    Note:This clock source switchover feature does not work if digital trunk
    connectivity is split between two Dual 
    Tl cards.
    When configuring the system, use the network clock as the system clock reference to
    prevent frame slips (Figure 
    2-6). However, use the internal clock reference when the
    trunks are connected to channel banks.
    Series 6
    ServerDigital Trunk 
    #l
    Digital Trunk #2
    Digital Trunk 
    #3
    Digital Trunk 
    #4Switch
    SwitchSync to Trunk
    Known Clock Source
    Series 6Server
    Sync internal
    !zziJ-y i*na,~ Switch ,
    I
    ‘E’Digital Trunk #4 1
    II Lines
    x1893vm6Figure 2-6
    Digital Trunk Clock Synchronization
    Digital Trunk Online MaintenanceThe 
    VoiceMemo application has an online maintenance utility for monitoring
    digital trunk activity and statistics (either individual trunks or all trunks), changing
    the clock reference, removing trunks from service, and looping back trunks toward
    the facility. Trunk activity includes the operational state of a trunk, 
    errored seconds,
    frame slips, and so forth. The display presents trunk status and the configuration of
    the trunk-a useful feature for quickly validating trunk setup.
    The information displayed is dynamic and changes as trunk status changes. For
    example, if a trunk is taken out of service, this utility immediately reports it to the
    display. Refer to the 
    Centignm Series G Diagnostics Manual for further information.
    .a
    2-16 
    						
    							Configuration Task list
    Page 1 of 1
    VoiceMemo Release 6.OA and later
    Procedure
    E 1 /Tl ConfigurationChangethe Digital Trunk Connectivity Clock Reference...........................CP
    3 152Dual El Offline Configuration...................................................................cl? 3151
    Dual T 1 Offline Configuration..................................................................
    cl? 3150
    Monitor Digital Trunk Statistics................................................................
    CP 3153
    Place a Digital Trunk Into Service..............................................................
    CP 3155
    Put Digital Trunk Out of Service...............................................................
    CP3154 
    						
    							cl? 3150
    Dual 
    Tl Offline ConfigurationPage 
    1 of 6
    VoiceMemo Release 6.OA and later
    Though typically a factory-installed standard feature, the Dual 
    Tl digital trunk
    connectivity feature can be retrofitted to a Series 6 server in the field. Use this procedure
    if you are adding a Dual 
    Tl Digital Trunk Interface card to a Series 6 server that you
    already have. This procedure presumes that you have already set the card jumpers and
    switches and installed it in the Series 6 server.
    This procedure gives you the instructions for configuring the feature software to support
    a 
    Tl digital trunk. Tl trunk configuration is done offline using the Resource Manager.
    In this procedure you will set:
    lModule number in which the Dual Tl card resides
    lI/O port address of the card
    lSignaling used on the trunk channels
    lTrunk number (0 through 60), framing format (D3/D4 or ESF), and coding (AM1 or AM1
    with ZCS)
    Dot. Rev. A 
    						
    							cl? 3150
    Page 2 of 6VoiceMemo Release 6.OA and later
    Step
    1.Reach the offline Resource Configuration Menu.
    2.Add a resource card number.
    Select:(A) Add resource card
    Prompt: Available slots are: x x x 9 x 11 x x x
    Input your choice:
    Response: The card number according to the Model of the Series 6 server (refer to
    the following Series 6 server matrix for Model 640 and Model 
    120.9.For Model 1201, type 6. For Model 70, type 3.
    Slot No.
    8
    9
    10
    11
    12
    13
    14
    15Slot No.
    4
    5
    -
    6
    7
    8
    9
    10
    11Model 640 (60
    ports/module maximum)
    Config. No. 1Config. No. 2Config. No. 3
    DSP8-7*Dual Tl-0Dual Tl-0Dual Tl-0
    DSP24-0DSP24-0DSP8-1Dual Tl-1
    DSP24- 1DSP8-2
    DSP24-1DSP8-3Dual Tl-1
    DSP24/DSP8-5*
    DSP8-6*Model 
    120s (60 port maximum)
    Config. No. 1Config. No. 2Config. No. 3
    DSP8-7*
    DSP8-6*Dual Tl-0
    Dual Tl-0Dual 
    Tl-0Model 
    120s (60 port maximum)
    DSP24-0DSP24-0DSP8-1Dual 
    Tl-1DSP24-1DSP8-2
    DSP24-1DSP8-3Dual Tl
    DSP24-l/DSP8-
    5*
    Config. No. 4
    Dual Tl-0
    DSP8-1
    DSP8-2
    DSP8-3
    DSP8-4
    DSP8-5
    DSP8-6
    Config. No. 4
    DSP8-6*Dual Tl-0
    DSP8-1
    DSP8-2
    DSP8-3
    DSP24- 1 /DSP8-
    4*
    DSP8-5*
    ReferenceMenu Map
    13 
    						
    							cl? 3150
    Page 3 of 6
    VoiceMemo Release 6.OA and later
    Step
    *DSPS modules installed only if DSP24-1 not present. Cards can e a mix of DSP8/24s and
    LC8s so long as total ports per module does not exceed GO.Only count number of Tl channels
    enabled (Fractional 
    Tl). Fax ports are not included n the total port count. The confirmationmessage Board [DUAL 
    Tll is added to slot x,where “x istheslot
    number you added in Step 1 above.
    3.At the Add Board to Database Menu, add the digital trunk interface card. Exit back
    to the Resource Configuration Menu when done.
    Select:(A) DUAL Tl
    prompt: Input your choice, ? for help
    (A/B/C/D/E/F/X/?):r.Response: The card number according to the Model of the Series 6 server (refer to
    the matrix above for Series 6 for Model 640 and Model 
    120s). For
    Model 1201, type 6. For Model 70, type 3.
    4.At the Resource Configuration Menu, identify the logical number of the module.
    For Model 640, this number can be either 
    1,2, 3, or 4. For Model 120 and Model
    70, this number is 1.
    Select:(M) set Module number
    Prompt:Input Module 
    #:Response: 
    1,2, 3, or 4.
    5.At the Resource Configuration Menu, configure the Dual Tl Digital Trunk
    Interface card.
    Select:(C) Configure resource card
    Prompt: Occupied slots are:
    Slot
    Card
    ---- 
    ---_---- ---_xxDUAL 
    TlInput your choice:
    Response: The card number according to the Model of the Series 6 server (refer to
    the Series 6 server matrix that follows Step 2 for Model 640 and Model
    120s). For Model 1201, type 6. For Model 70, type 3.
    6.From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the
    slot number entered in Step 
    5), reach Change IO Port Address Menu to configure
    the IO port address for the card.
    7.At the Select IO Port Address Menu, select the input/output address for which the
    card is physically configured. The addresses are Ox300h (the default address for card0) and 
    Ox23OOh for card 1. Exit back to the Configuration Menu for Board [DUAL
    Tl] in AT slot x Menu when you are done.
    8.From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the
    slot number entered in Step 4), reach the Configuration Menu for Tl/El Carrier at
    trunk 0 to configure the digital trunk.
    2
    RefiremeMenu Map 13
    TR 2005
    Menu Map 13
    Dot. Rev. A 
    						
    							. . .
    CP 3150
    Page 4 of 6
    VoiceMemo Release 6.OA and lat’er
    Step9.At the Configuration Menu for 
    Tl /El Carrier at trunk 0, set the logical number of
    the trunk.Trunk configuration consists of setting the trunk number, framing, and
    coding.
    Select:(T) set Trunk number
    Prompts Input your choice, ? for help
    (T/F/C/D/?):
    Response: 0 or 1
    10. From the Configuration Menu for 
    Tl/El Carrier at trunk 0, reach the Configure
    Frame Format for Board [DUAL 
    Tl] in AT slot x Trunk 0 Menu.0.11. At the Configure Frame Format for [DUAL 
    Tl] in AT slot x Trunk y (where “y” is
    the trunk number you entered in Step 
    9), select the framing format you want for the
    trunk. You can frame the trunk as either a 
    D3/D4 trunk (with KM 12-channels)or as an ESF trunk (24 PCM channels). The CEPT and CRC framing options are
    not available for 
    Tl trunks.
    Because you have not yet set the trunk coding format, the default AM1 (alternate
    mark inversion) coding appears in the confirmation. Also, because CAS is the only
    signaling type available for Series 6 
    Tl trunk connectivity, CAS appears in the
    confirmation message as the selected signaling type.
    12. Exit to the Configuration Menu for 
    Tl/El Carrier at trunk 0 when you are done.
    13. From the Configure Menu for 
    Tl/El Carrier at trunk 0, reach the Configure Frame
    Coding for Board [DUAL 
    Tl] in AT slot x Trunk y Menu.
    14. At the Configure Frame Coding for Board [DUAL 
    Tl] in AT slot x Trunk y Menu,
    select the trunk coding format you want. The coding type can be either AM1 or
    AM1 with ZCS (zero code suppression).
    15. From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the
    slot 
    number entered in Step 4), select the PCM channels you want to configure for a
    -type of signaling.
    Select 
    KM channels as a range (for example, O-4) or as a series (for example,
    2,4,6,9,15,16,24). Channel numbers begin at 00 and end at 47 where KMchannels 00 through 23 are carried by trunk 0 and PCM channels 24 through 47 are
    carried by trunk 1.
    Select:(T) set Trunk signaling type
    Prompt Input a range channels (O-4 or 1,4,7, and so
    forth):
    Response:The numbers of the PCM channels whose signaling you want to
    configure.
    Pressing Enter takes you to the Select Trunk Type Menu.
    Dot. Rev. A
    Reference
    vlenu Map 13 
    						
    							cl? 3150
    Page 5 of 6VoiceMemo Release 6.OA and later
    Step16. At the Select Trunk Type Menu, select the signaling associated with the PCM
    channels you selected in Step 15. You can select only the options for digital trunks.
    If you select signaling for analog signaling, you get the error message “Can not set
    Analog trunk 
    type to Digital Trunk.”
    Select:(4) Digital-E&M, (5) Digital-Loopstart, (6) Digital-DID, or (7)
    Digital-Groundstart
    PT-0FZp t:Input your choice, ? for help
    (0/1/2/3/4/5/6/7/S/X/?):Response: 4, 5, 6, or 7, as appropriate.
    8.After you select the signaling type, you get this confirmation message: The following
    confirmation message:
    The following channels are set to: 
    Digital-xXxXTrunk: y
    Channels: 
    a,b,c,dwhere 
    “xxxx” is the signaling type you selected in Step 8 above, “y” is the number of
    the trunk (0 or I), and 
    “a,b,c,d” are the numbers of the KM channels you selected
    in Step 15 above. LS = loop start, GS = ground start, DID = direct inward dial, and
    E&M = E&M.
    17. Repeat Steps 15 and 16 until you have selected the trunk signaling the for each of
    the available PCM channels associated with the Dual 
    Tl digital trunk interface card
    that you are configuring.
    18. Exit back to the Configuration Menu for Board [DUAL 
    Tl] in AT slot x when you
    are done.
    19. At the Configuration Menu for Board [DUAL 
    Tl] in AT slot x, display the current
    trunk configuration to review the signaling that you have configured for each PCM
    channel. Figure 1 shows a typical trunk configuration list.
    -To correct any signaling configuration errors, repeat Steps 15 and 16 as required.
    20 Exit back to the Resource Configuration Menu when you are satisfied with your
    trunk signaling configuration.
    Reference
    denu Map
    Doe. Rev. A
    13 
    						
    							CP 3150Page 6 of 6
    VoiceMemo Release 6.OA and later
    Card: DUAL Tl
    IO Port Address: OX300
    Resources: (48) Net-Dat; (48) Net-Sig;
    ---____---
    Tl/El Carrier configuration:
    Trunk: 0Configuration: 
    D3/D4, BBZS, CAS
    Trunk: 1Configuration: D3/D4, AM1 ZCS, CAS----------
    Trunk Type for each channel:
    Chnl:
    0001020304 05 060708091011
    Type:E&M E&M E&M E&ME&M LS LS LS LS LS LS LSs.
    Chnl:1213141516 17 181920212223
    Type: LSLS LS LS LS LSLS LSLS LS LS LS
    Chnl:24
    25262728 29 303132333435
    Type: LSLS LS LS LS LS LS LSLS LS LS LS
    Chnl:
    3637383940 41 424344454647
    Type:LS LS LS LS LS LS LS LS LS LS LS LSFigure 1Typical Trunk Configuration List
    2 1. From the Resource Configuration Menu, reach the Digital Clock Reference
    Configuration Menu.
    22. From the Digital Clock Reference Configuration Menu, select the clock reference
    for the digital trunks. Your options include a reference derived from the network
    RxD signal, and the default clock reference (trunk 0).
    Note:the internal clock reference is provided for those applications where the
    server is connected to channel banks and no network clock reference is
    savailable.
    23. Exit back to the 
    VoiceMemo Configuration - Main Menu when you are done.
    24. If you have completed your digital trunk connectivity feature configuration, activate
    the configuration. If you have not completed configuring digital trunk connectivity,
    go to the appropriate procedure.
    Reference
    tienu Map 13
    Doe. Rev. A 
    						