Dual Tl Digital Trunk Connectivity 1--811Model 70 and Model 1201 supports only one digital trunk for a maximum system capacity of 24 KM voice channels. The Model 120s and the Model 640 module each supports up to 60 PCM voice channels between two digital trunk interface cards.You assign the slot at the Physical Resource Configuration Menu for the card you are configuring. Module NumberThe module number is the Series 6 server module in which the digital trunk interface card is installed. A four-module Series 6 Model 640 server can support a total capacity of 240 PCM voice channels over 16 trunks.(In such ‘a configuration the line groups would be configured to use only part of the total number of PCM channels - that is fractional Tl - available in each trunk. Refer to “TlConnectivity Features” on page 7.) You assign the slot at the Physical Resource Configuration Menu for the card you are configuring. Input/Output AddressThe digital trunk interface card can occupy one of two possible AT bus addresses: Ox3OOh and Ox2300h where address Ox300h is the default address occupied by card 0 and Ox2300h is assigned to card 1. These addresses can also be assigned to a Smartcard in Model 70 and I201 servers. Before selecting the I/O address, check the addresses occupied by these cards if they are present in the affected Series 6 server module. If these cards are and either of their addresses are set to the same to which the digital trunk interface card, an address conflict exists and bus contention will occur. Ensure that each card is set to a unique address. The address selected in the Select IO Address Menu must match the address for which the card is physically jumpered. Note:The digital trunk interface card has jumper positions for setting interrupt request levels. However, the VoiceMemo application polls the hardware to detect status and service the cards and does not use hardware interrupt requests. You set the card I/O address in the Configuration Menu for Board [DUAL Tll in AT slot x. SignalingEach channel in the digital trunk interface can be set for one of these four types of channel associated signaling according to the requirements of CSUs, channel banks, or other related equipment to which the Series 6 server is connected: 2 2-14
Dual T1 Digital Trunk Connectivity l Loop start l Ground start lDirect Inward Dial (DID) . E&M You set the trunk signaling in the Select Trunk Type Menu. The menu has options for both analog and digital trunks. However, when you are configuring a digital trunk interface card, the configuration manager accepts only the digital trunk options. Trunk ConfigurationTrunk configuration includes the trunk number, framing format, and coding format. Trunk Sequence NumberThe trunk number is the logical number of the trunk, beginningwith trunk number 0 on trunk card 1. You set the trunk number at the Configuration menu for Tl/ElCarrier at trunk x Menu. Framing FormatThe Series G server supports D4 12channel frames and extended superframe (ESF) 24 channel frames. You select the framing format the trunk uses at the Configure Frame Format for Board [DUAL Tl] in AT slot x Trunk y Menu. Coding FormatThe Series 6 server supports B8ZS, AM1 (alternate mark inversion) and AM1 with ZCS (zero code suppression) coding formats for Tl trunks. You select coding for the trunk at the Configure Frame Coding for Board [DUAL Tl] in AT slot x Trunk y Menu. Clock SynchronizationThe system master clock must be synchronized to the nenvork (that is, a selected Tl F&D signal). The digital clock reference can be set to one of the following: 0Network l Default 0Internal (reserved for connections to channel banks) The network clock referenceis the I&D signal of a selected Tl trunk. In the case of Model 70 and Model 1201, the selected trunk is trunk 0. For Model 12OS, selected trunk can be 0 or 1. For Model 640, the selected trunk can be 0, 1, 2, or 3 (only one trunk can be selected). The default reference is trunk 0. The Series 6 server features automatic switchover to a backup clock source if the primary fails. However, this feature functions only when both trunks of a Dual TIcard are used and the clock is synchronized to the RxD signal of one of them.. 2-15
Dual T1 Digital Trunk ConnectivityThen, if the trunk to which the clock reference is derived, the Series G server will automatically switch over to the second trunk on the Dual Tl card. Note:This clock source switchover feature does not work if digital trunk connectivity is split between two Dual Tl cards. When configuring the system, use the network clock as the system clock reference to prevent frame slips (Figure 2-6). However, use the internal clock reference when the trunks are connected to channel banks. Series 6 ServerDigital Trunk #l Digital Trunk #2 Digital Trunk #3 Digital Trunk #4Switch SwitchSync to Trunk Known Clock Source Series 6Server Sync internal !zziJ-y i*na,~ Switch , I ‘E’Digital Trunk #4 1 II Lines x1893vm6Figure 2-6 Digital Trunk Clock Synchronization Digital Trunk Online MaintenanceThe VoiceMemo application has an online maintenance utility for monitoring digital trunk activity and statistics (either individual trunks or all trunks), changing the clock reference, removing trunks from service, and looping back trunks toward the facility. Trunk activity includes the operational state of a trunk, errored seconds, frame slips, and so forth. The display presents trunk status and the configuration of the trunk-a useful feature for quickly validating trunk setup. The information displayed is dynamic and changes as trunk status changes. For example, if a trunk is taken out of service, this utility immediately reports it to the display. Refer to the Centignm Series G Diagnostics Manual for further information. .a 2-16
Configuration Task list Page 1 of 1 VoiceMemo Release 6.OA and later Procedure E 1 /Tl ConfigurationChangethe Digital Trunk Connectivity Clock Reference...........................CP 3 152Dual El Offline Configuration...................................................................cl? 3151 Dual T 1 Offline Configuration.................................................................. cl? 3150 Monitor Digital Trunk Statistics................................................................ CP 3153 Place a Digital Trunk Into Service.............................................................. CP 3155 Put Digital Trunk Out of Service............................................................... CP3154
cl? 3150 Dual Tl Offline ConfigurationPage 1 of 6 VoiceMemo Release 6.OA and later Though typically a factory-installed standard feature, the Dual Tl digital trunk connectivity feature can be retrofitted to a Series 6 server in the field. Use this procedure if you are adding a Dual Tl Digital Trunk Interface card to a Series 6 server that you already have. This procedure presumes that you have already set the card jumpers and switches and installed it in the Series 6 server. This procedure gives you the instructions for configuring the feature software to support a Tl digital trunk. Tl trunk configuration is done offline using the Resource Manager. In this procedure you will set: lModule number in which the Dual Tl card resides lI/O port address of the card lSignaling used on the trunk channels lTrunk number (0 through 60), framing format (D3/D4 or ESF), and coding (AM1 or AM1 with ZCS) Dot. Rev. A
cl? 3150 Page 2 of 6VoiceMemo Release 6.OA and later Step 1.Reach the offline Resource Configuration Menu. 2.Add a resource card number. Select:(A) Add resource card Prompt: Available slots are: x x x 9 x 11 x x x Input your choice: Response: The card number according to the Model of the Series 6 server (refer to the following Series 6 server matrix for Model 640 and Model 120.9.For Model 1201, type 6. For Model 70, type 3. Slot No. 8 9 10 11 12 13 14 15Slot No. 4 5 - 6 7 8 9 10 11Model 640 (60 ports/module maximum) Config. No. 1Config. No. 2Config. No. 3 DSP8-7*Dual Tl-0Dual Tl-0Dual Tl-0 DSP24-0DSP24-0DSP8-1Dual Tl-1 DSP24- 1DSP8-2 DSP24-1DSP8-3Dual Tl-1 DSP24/DSP8-5* DSP8-6*Model 120s (60 port maximum) Config. No. 1Config. No. 2Config. No. 3 DSP8-7* DSP8-6*Dual Tl-0 Dual Tl-0Dual Tl-0Model 120s (60 port maximum) DSP24-0DSP24-0DSP8-1Dual Tl-1DSP24-1DSP8-2 DSP24-1DSP8-3Dual Tl DSP24-l/DSP8- 5* Config. No. 4 Dual Tl-0 DSP8-1 DSP8-2 DSP8-3 DSP8-4 DSP8-5 DSP8-6 Config. No. 4 DSP8-6*Dual Tl-0 DSP8-1 DSP8-2 DSP8-3 DSP24- 1 /DSP8- 4* DSP8-5* ReferenceMenu Map 13
cl? 3150 Page 3 of 6 VoiceMemo Release 6.OA and later Step *DSPS modules installed only if DSP24-1 not present. Cards can e a mix of DSP8/24s and LC8s so long as total ports per module does not exceed GO.Only count number of Tl channels enabled (Fractional Tl). Fax ports are not included n the total port count. The confirmationmessage Board [DUAL Tll is added to slot x,where “x istheslot number you added in Step 1 above. 3.At the Add Board to Database Menu, add the digital trunk interface card. Exit back to the Resource Configuration Menu when done. Select:(A) DUAL Tl prompt: Input your choice, ? for help (A/B/C/D/E/F/X/?):r.Response: The card number according to the Model of the Series 6 server (refer to the matrix above for Series 6 for Model 640 and Model 120s). For Model 1201, type 6. For Model 70, type 3. 4.At the Resource Configuration Menu, identify the logical number of the module. For Model 640, this number can be either 1,2, 3, or 4. For Model 120 and Model 70, this number is 1. Select:(M) set Module number Prompt:Input Module #:Response: 1,2, 3, or 4. 5.At the Resource Configuration Menu, configure the Dual Tl Digital Trunk Interface card. Select:(C) Configure resource card Prompt: Occupied slots are: Slot Card ---- ---_---- ---_xxDUAL TlInput your choice: Response: The card number according to the Model of the Series 6 server (refer to the Series 6 server matrix that follows Step 2 for Model 640 and Model 120s). For Model 1201, type 6. For Model 70, type 3. 6.From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the slot number entered in Step 5), reach Change IO Port Address Menu to configure the IO port address for the card. 7.At the Select IO Port Address Menu, select the input/output address for which the card is physically configured. The addresses are Ox300h (the default address for card0) and Ox23OOh for card 1. Exit back to the Configuration Menu for Board [DUAL Tl] in AT slot x Menu when you are done. 8.From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the slot number entered in Step 4), reach the Configuration Menu for Tl/El Carrier at trunk 0 to configure the digital trunk. 2 RefiremeMenu Map 13 TR 2005 Menu Map 13 Dot. Rev. A
. . . CP 3150 Page 4 of 6 VoiceMemo Release 6.OA and lat’er Step9.At the Configuration Menu for Tl /El Carrier at trunk 0, set the logical number of the trunk.Trunk configuration consists of setting the trunk number, framing, and coding. Select:(T) set Trunk number Prompts Input your choice, ? for help (T/F/C/D/?): Response: 0 or 1 10. From the Configuration Menu for Tl/El Carrier at trunk 0, reach the Configure Frame Format for Board [DUAL Tl] in AT slot x Trunk 0 Menu.0.11. At the Configure Frame Format for [DUAL Tl] in AT slot x Trunk y (where “y” is the trunk number you entered in Step 9), select the framing format you want for the trunk. You can frame the trunk as either a D3/D4 trunk (with KM 12-channels)or as an ESF trunk (24 PCM channels). The CEPT and CRC framing options are not available for Tl trunks. Because you have not yet set the trunk coding format, the default AM1 (alternate mark inversion) coding appears in the confirmation. Also, because CAS is the only signaling type available for Series 6 Tl trunk connectivity, CAS appears in the confirmation message as the selected signaling type. 12. Exit to the Configuration Menu for Tl/El Carrier at trunk 0 when you are done. 13. From the Configure Menu for Tl/El Carrier at trunk 0, reach the Configure Frame Coding for Board [DUAL Tl] in AT slot x Trunk y Menu. 14. At the Configure Frame Coding for Board [DUAL Tl] in AT slot x Trunk y Menu, select the trunk coding format you want. The coding type can be either AM1 or AM1 with ZCS (zero code suppression). 15. From the Configuration Menu for Board [DUAL Tl] in AT slot x (where x is the slot number entered in Step 4), select the PCM channels you want to configure for a -type of signaling. Select KM channels as a range (for example, O-4) or as a series (for example, 2,4,6,9,15,16,24). Channel numbers begin at 00 and end at 47 where KMchannels 00 through 23 are carried by trunk 0 and PCM channels 24 through 47 are carried by trunk 1. Select:(T) set Trunk signaling type Prompt Input a range channels (O-4 or 1,4,7, and so forth): Response:The numbers of the PCM channels whose signaling you want to configure. Pressing Enter takes you to the Select Trunk Type Menu. Dot. Rev. A Reference vlenu Map 13
cl? 3150 Page 5 of 6VoiceMemo Release 6.OA and later Step16. At the Select Trunk Type Menu, select the signaling associated with the PCM channels you selected in Step 15. You can select only the options for digital trunks. If you select signaling for analog signaling, you get the error message “Can not set Analog trunk type to Digital Trunk.” Select:(4) Digital-E&M, (5) Digital-Loopstart, (6) Digital-DID, or (7) Digital-Groundstart PT-0FZp t:Input your choice, ? for help (0/1/2/3/4/5/6/7/S/X/?):Response: 4, 5, 6, or 7, as appropriate. 8.After you select the signaling type, you get this confirmation message: The following confirmation message: The following channels are set to: Digital-xXxXTrunk: y Channels: a,b,c,dwhere “xxxx” is the signaling type you selected in Step 8 above, “y” is the number of the trunk (0 or I), and “a,b,c,d” are the numbers of the KM channels you selected in Step 15 above. LS = loop start, GS = ground start, DID = direct inward dial, and E&M = E&M. 17. Repeat Steps 15 and 16 until you have selected the trunk signaling the for each of the available PCM channels associated with the Dual Tl digital trunk interface card that you are configuring. 18. Exit back to the Configuration Menu for Board [DUAL Tl] in AT slot x when you are done. 19. At the Configuration Menu for Board [DUAL Tl] in AT slot x, display the current trunk configuration to review the signaling that you have configured for each PCM channel. Figure 1 shows a typical trunk configuration list. -To correct any signaling configuration errors, repeat Steps 15 and 16 as required. 20 Exit back to the Resource Configuration Menu when you are satisfied with your trunk signaling configuration. Reference denu Map Doe. Rev. A 13
CP 3150Page 6 of 6 VoiceMemo Release 6.OA and later Card: DUAL Tl IO Port Address: OX300 Resources: (48) Net-Dat; (48) Net-Sig; ---____--- Tl/El Carrier configuration: Trunk: 0Configuration: D3/D4, BBZS, CAS Trunk: 1Configuration: D3/D4, AM1 ZCS, CAS---------- Trunk Type for each channel: Chnl: 0001020304 05 060708091011 Type:E&M E&M E&M E&ME&M LS LS LS LS LS LS LSs. Chnl:1213141516 17 181920212223 Type: LSLS LS LS LS LSLS LSLS LS LS LS Chnl:24 25262728 29 303132333435 Type: LSLS LS LS LS LS LS LSLS LS LS LS Chnl: 3637383940 41 424344454647 Type:LS LS LS LS LS LS LS LS LS LS LS LSFigure 1Typical Trunk Configuration List 2 1. From the Resource Configuration Menu, reach the Digital Clock Reference Configuration Menu. 22. From the Digital Clock Reference Configuration Menu, select the clock reference for the digital trunks. Your options include a reference derived from the network RxD signal, and the default clock reference (trunk 0). Note:the internal clock reference is provided for those applications where the server is connected to channel banks and no network clock reference is savailable. 23. Exit back to the VoiceMemo Configuration - Main Menu when you are done. 24. If you have completed your digital trunk connectivity feature configuration, activate the configuration. If you have not completed configuring digital trunk connectivity, go to the appropriate procedure. Reference tienu Map 13 Doe. Rev. A