Panasonic Kx Td500 User Manual
Have a look at the manual Panasonic Kx Td500 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Station Features and Operation (PT/SLT) User Manual411 4.4.3 Call Log Incoming, Log Lock The Manager and the Operators can cancel the Call Log Incoming, Log Lock feature set at any other extension. Programming Conditions If the extension user forgets his pre-set password, he can ask the Manager or an Operator to clear the password. User Manual References 4.5.5 Call Log Incoming, Log Lock (KX-T7436 / KX-T7433 / KX-T7235 / KX-T7230 only) PT You are in the Station Programming mode: PT—PGM Mode EXT NO? 1234:Unlock? Press PROGRAM. Press PROGRAM to exit the Station Programming mode. Dial 99. Dial 02.Press STORE. Dial the extension number (3 or 4 digits) or . - extension number: to clear one extension- : to clear all extensions extension no. or AUTO DIAL STORE9902 PROGRAM PROGRAM The STORE indicator lights.
Station Features and Operation (PT/SLT) 412User Manual 4.4.4 Live Call Screening (LCS) Password Clear*1 The Manager and the Operators can clear the Live Call Screening password of any extension. Programming Conditions If the extension users forget their pre-set password, they can ask the Manager or an Operator to clear the password. User Manual References 4.3.43 Live Call Screening (LCS) *1Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System (one that supports Digital Proprietary Telephone [DPT] integration; e.g., KX-TVS100). PT You are in the Station Programming mode: PT—PGM Mode EXT NO? 1234:Cancel? Press PROGRAM. Dial 99. Dial 03. Press STORE. extension no. or Dial the extension number (3 or 4 digits) or . - extension number: to clear one extension- : to clear all extensions AUTO DIAL STORE 9903PROGRAM The STORE indicator lights.
Station Features and Operation (PT/SLT) User Manual413 4.4.5 Local Alarm If a system error is detected during on-line communication mode, the Alarm light on the Manager extension turns red. The Manager can confirm the error message by pressing the red lit Alarm button. If a major error occurs, minor errors will be neglected and only the first major error message will be displayed. The second error will be neglected, if the error priority is the same as the first one. Please refer to Section 5 Troubleshooting in the Installation Manual for further information on error messages. Error Message List (Priority order) Error Message Description Priority Alarm LED ERR CLCK ICCalendar IC failure 1 A ERR DC DOWNDC power down 1 B B/S FAN FLT!Basic shelf fan alarm 1 E E/S1 FAN FLT!Expansion shelf 1 fan alarm 1 E E/S2 FAN FLT!Expansion shelf 2 fan alarm 1 E B/S OVER HEAT!Basic shelf heat alarm 1 E E/S1 OVER HEAT!Expansion shelf 1 heat alarm 1 E E/S2 OVER HEAT!Expansion shelf 2 heat alarm 1 E ERR TSW DWNTSW clock down 1 B ERR BAT ALMCPU RAM battery alarm 1 A ERR AC DOWNAC power down 2 B ERR xyy CRD ERROption Card failure 2 A ERR xyy DISCNCTCard disconnect 2 B ERR xyy DTR AISDigital trunk AIS reception 2 D *1 ERR xyy DTR FRMDigital trunk frame failure 2 D*1 ERR xyy DTR RAIDigital trunk RAI reception 2 D*1 ERR xyy DTR SYCDigital trunk out of synchronization2D*1 ERR xyy LPR RAMOption Card RAM failure 2 A ERR xyy LPR ROMOption Card ROM failure 2 A ERR xyyz MODEMModem failure 2 A ERR xyy OGM LOSDISA OGM is lost 2 C ERR xyy OPX POWOPX power failure 2 C ERR SMDRPrinter is not connected 2 B
Station Features and Operation (PT/SLT) 414User Manual [Legend] Error Message Priority Alarm LED (When a problem occurs) The Alarm light turns red automatically. The corresponding error message is shown on the display PT, if it is idle, by pressing the red lit Alarm button. If the red lit Alarm button is pressed again, whether the problem is solved or not, the Alarm light goes off and the display PT shows the initial display (Date and Time or Self- Extension number). The Alarm light turns red and the corresponding error message is shown on the display PT automatically, if it is idle. This situation continues until the problem will be solved. (When the problem is solved) ERR xyy DSP1LNKDSP-1 link failure 2 D *1 ERR xyy CD FLTCard status fault 2 A *1Regarding the T1 card, please refer to Reference Guide for T1 Digital Trunk card. x: Shelf Number (1-3) yy: Slot Number (01-14) z: Error Number 1: Major Error 2: Minor Error A: LED on PT / Top Shelf / Card...........................OFF ON B: LED on PT / Top Shelf............................OFF ON C: LED on PT.............................OFF ON D: LED on PT / Card.............................OFF ON E: LED on PT / Top Shelf...........................OFF ON A/B/C/D: LED on PT..............................................ON (no change) LED on Top Shelf / Card...................................ON OFF E: LED on PT / Top Shelf.............................ON OFFError Message List (Priority order) Error Message Description Priority Alarm LED
Station Features and Operation (PT/SLT) User Manual415 When the problem is solved, the Alarm light goes off and the display PT shows the initial display. Displaying an error message Clearing the error message Conditions Alarm button assignment Alarm button can be assigned to a flexible CO button on PT by Station, User or System Programming. Alarm LED indication Major alarm (Priority 1) – Red moderate flash Minor alarm (Priority 2) – Red On If multiple errors occur at a time, only the error with highest priority will be displayed by pressing the red lit Alarm button. PT Press the red lit Alarm (flexible button). When the Alarm button turns red; ERR 20211DISCNCT (Alarm) PT Press the red lit Alarm (flexible button). (Alarm) While the error message is displayed; Date and Time display WED JAN 1 10:40A
Station Features and Operation (PT/SLT) 416User Manual Programming Guide References 4.3 Extension Line – CO Key Features Guide References 1.4 Fault Recovery/Diagnostics Local Alarm User Manual References 2.2.3 Flexible Button Assignment 3.2.5 [005] Flexible CO Button Assignment
Station Features and Operation (PT/SLT) User Manual417 4.4.6 Outgoing Message (OGM) Record/Playback The Manager and the Operators can record and play back outgoing voice messages. Recording a message 7235 / 7436 Lift the handset or press SP-PHONE. Record a message (up to 30 seconds). OGM Group no. Enter OGM Group number (1 through 8). AUTO DIAL STORE Press STOREor wait until a maximum recording time (30 seconds) has elapsed. Press Features. Confirmation tone AUTO DIAL STORE Press STOREor wait until playback is finished. Confirmation tone Hang up or press SP-PHONE. Confirmation tone and dial tone FeaturesNEXT OROGM Recording(→1-8) The recording is stopped and STORE indicator light turns steady red. The recorded message will be played back automatically. Time counter (seconds) OGM group number selected (1 through 8) The STORE indicator light flashes red slowly. Recording starts after the confirmation tone. OGM 2 Rec.:00 OGM 2 Play:28 The STORE indicator light turns off. Rotate Jog Dialor press NEXT until the following is displayed.Press OGM Recording.
Station Features and Operation (PT/SLT) 418User Manual Recording a message Lift the handset or press SP-PHONE. Record a message (up to 30 seconds). OGM Group no. Enter OGM Group number (1 through 8). AUTO DIAL STORE Press STOREor wait until a maximum recording time (30 seconds) has elapsed. Press MODEuntil Feature Accessis displayed. Confirmation tone AUTO DIAL STORE Press STOREor wait until playback is finished. Confirmation tone Hang up or press SP-PHONE. OGM Record 1-8→SELECT MODE The recording is stopped and STORE indicator light turns steady red. The recorded message will be played back automatically. Time counter (seconds) OGM group number selected (1 through 8) The STORE indicator light flashes red slowly. Recording starts after the confirmation tone. OGM 2 Rec.:00 OGM 2 Play:28 The STORE indicator light turns off. Rotate Jog Dialuntil OGM Record is displayed.Press SELECT. 7431 MODE Confirmation tone and dial tone
Station Features and Operation (PT/SLT) User Manual419 Recording a message Lift the handset or press SP-PHONE. Record a message (up to 30 seconds). OGM Group no. Enter OGM Group number (1 through 8). AUTO DIAL STORE Press STOREor wait until a maximum recording time (30 seconds) has elapsed. Confirmation tone AUTO DIAL STORE Press STOREor wait until playback is finished. Confirmation tone Hang up or press SP-PHONE. The recording is stopped and STORE indicator light turns steady red. The recorded message will be played back automatically. Time counter (seconds) OGM group number selected (1 through 8) The STORE indicator light flashes red slowly. Recording starts after the confirmation tone. OGM 2 Rec.:00 OGM 2 Play:28 The STORE indicator light turns off. Press SHIFTuntil FEATis displayed.Press FEAT. Rotate Jog Dialuntil OGM Record is at the arrow.Press SEL. SHIFTFEAT OGM Record 1-8 Page Deny 1/0 MENU → SEL 7433 Confirmation tone and dial tone
Station Features and Operation (PT/SLT) 420User Manual Recording a message Lift the handset or pressSP-PHONE/MONITOR.Enter OGM Group number (1 through 8).Record a message (up to 30 seconds). Press STORE or wait until a maximum recording time (30 seconds) has elapsed.Confirmation tone Confirmation tone Press STORE or wait until playback is finished Dial 361. OGM Group no. Hang up or press SP-PHONE/MONITOR. 361 AUTO DIAL STORE AUTO DIAL STORE Time counter (seconds) OGM group number selected (1 through 8) The STORE indicator light flashes red slowly. Recording starts after the confirmation tone. OGM 2 Rec.:00 The recording is stopped and STORE indicator light turns steady red. The recorded message will be played back automatically. The STORE indicator light turns off. OGM 2 Play:28 PT and SLT Confirmation tone and dial tone