Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-45 SNC Switc h Nod e Cloc k SNI Switc h Nod e Interface SNMP Simple Network Manag ement Protoc ol software A set of comp uter p rog rams that perform one or more tasks. SPE Switc h Proc essing Element SPID Servic e Profile Identifier split See ACD work mode . split condition A cond ition whereb y a caller is temp orarily sep arated from a connection with an attendant. A sp lit condition automatic ally oc c urs when the attend ant, ac tive on a call, presses the start b utton. split number The sp lit’s id entity to the switc h and BCMS. split report A rep ort that p rovid es historic al traffic information for internally measured splits. split (agent) status report A rep ort that p rovid es real-time status and measurement d ata for internally measured ag ents and the sp lit to whic h they are assig ned . SSI Standard serial interfac e SSM Sing le-site manag ement SSV Station service ST3 Stratum 3 c loc k b oard staffed Ind icates that an ag ent p osition is log g ed in. A staffed agent func tions in one of four work mod es: Auto-In, Manual-In, ACW, or AUX-Work. STARLAN Star-Based Loc al Area Network Station Message Detail Recording (SMDR) An ob solete term now c alled CDR — a switc h feature that uses software and hard ware to rec ord call d ata. See Call Detail Rec ord ing (CDR) . standard serial interface (SSI) A communications p rotoc ol d evelop ed for use with 500-type b usiness c ommunic ations terminals (BCTs) and 400-series printers.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-46 status lamp A g reen lig ht that shows the status of a c all ap pearanc e or a feature b utton b y the state of the lig ht (lit, flashing , fluttering , b roken flutter, or unlit). stroke counts A method used by ACD ag ents to rec ord up to nine c ustomer-d efined events p er c all when CMS is ac tive. SVN Sec urity-violation notific ation switch Any kind of telep hone switc hing system. See also c ommunic ations system . switchhook The buttons loc ated und er the rec eiver on a voic e terminal. switch-node (SN) carrier A carrier containing a sing le switc h node, power units, and, op tionally, one or two DS1 c onverter circuit p acks. An SN carrier is loc ated in a c enter-stag e switch. switch-node (SN) clock The circ uit p ac k in an SN c arrier that p rovid es clock and maintenanc e alarm functions and environmental monitors. switch-node interface (SNI) The basic b uild ing block of a switc h nod e. An SNI circuit p ack controls the routing of c irc uit, p ac ket, and c ontrol messag es. switch-node link (SNL) The hard ware that provid es a b rid g e b etween two or more switc h nodes. The SNL c onsists of the two SNI circ uit p ac ks resid ing on the switch nod es and the hard ware c onnec ting the SNIs. This hardware c an inc lud e lightwave transc eivers that c onvert the SNI’s elec tric al sig nals to light sig nals, the cop per wire that c onnec ts the SNIs to the lightwave transc eivers, a full-d up lex fib er-op tic c ab le, DS1 c onverter circuit c ard s and DS1 facilities if a c omp any d oes not have rig hts to lay cab le, and ap p rop riate c onnec tors. switch-processing element (SPE) A c omplex of c irc uit p ac ks (p roc essor, memory, d isk controller, and b us-interfac e cards) mounted in a PPN c ontrol c arrier. The SPE serves as the c ontrol element for that PPN and , op tionally, for one or m ore EPN s. SXS Step -by-step synchronous data transmission A method of sending d ata in which d iscrete sig nal elements are sent at a fixed and continuous rate and sp ec ified times. See also assoc iation . SYSAM System Ac c ess and Ad ministration system administrator The person who maintains overall c ustomer resp onsib ility for system ad ministration. Generally, all ad ministration func tions are p erformed from the Manag ement Terminal. The switc h requires a sp ecial log in, referred to as the system ad ministrator login, to gain acc ess to system-administration c ap abilities.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-47 system printer An op tional p rinter that may be used to print scheduled rep orts via the report sc hed uler. system report A rep ort that p rovid es historic al traffic information for internally measured splits. system-status report A rep ort that p rovid es real-time status information for internally measured sp lits. system manager A person resp onsib le for sp ec ifying and ad ministering features and servic es for a system. system reload A process that allows stored d ata to be written from a tap e into the system memory (normally after a power outage). T T1 A d ig ital transmission stand ard that in North Americ a carries traffic at the DS1 rate of 1.544 Mb ps. A T1 fac ility is divid ed into 24 channels (DS0s) of 64 kb p s. These 24 channels, with an overall d ig ital rate of 1.536 Mb p s, and an 8-kb ps framing and synchronization c hannel make up the 1.544-Mb p s transmission. When a D-c hannel is p resent, it oc c up ies channel 24. T1 fac ilities are also used in Jap an and some Mid d le-Eastern c ountries. TAAS Trunk Answer from Any Station TA B S Telemetry asynchronous b loc k serial TA C Trunk-acc ess c ode tandem switch A switch within an elec tronic tand em network (ETN) that p rovid es the log ic to d etermine the b est route for a network call, p ossib ly mod ifies the d igits outp ulsed , and allows or d enies c ertain calls to c ertain users. tandem through The switc hed c onnec tion of an inc oming trunk to an outg oing trunk without human intervention. tandem tie-trunk network (TTTN) A private network that interc onnects several customer switching systems. TC Technic al c onsultant TCM Traveling class mark TDM See time-d ivision multip lexing (TDM) . TDR Ti m e - o f - d a y r o u t i n g
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-48 TEG Terminating extension g roup terminal A devic e that sends and receives d ata within a system. See also ad ministration terminal . tie trunk A telec ommunic ations channel that direc tly connects two p rivate switching systems. time-division multiplex (TDM) bus A bus that is time-shared reg ularly by prealloc ating short time slots to eac h transmitter. In a PBX, all p ort circuits are c onnected to the TDM b us, p ermitting any port to send a sig nal to any other port. time-division multiplexing (TDM) Multip lexing that d ivid es a transmission channel into succ essive time slots. See also multip lexing . time interval The period of time, either one hour or one-half hour, that BCMS measurements are c ollec ted for a rep or t. time slice See time interval . time slot 64 kb p s of d ig ital information structured as eight bits every 125 mic rosec ond s. In the switc h, a time slot refers to either a DS0 on a T1 or E1 fac ility or a 64-kb p s unit on the TDM b us or fib er connec tion b etween p ort networks. time slot sequence integrity The situation whereb y the N oc tets of a wid eb and c all that are transmitted in one T1 or E1 frame arrive at the outp ut in the same ord er that they were introd uc ed. to control An ap plication c an invoke Third Party Call Control c apab ilities using either an ad junct-c ontrol or d omain-c ontrol assoc iation. to monitor An ap plication c an rec eive event rep orts on an ac tive-notific ation, ad junc t-c ontrol, or d omain-c ontrol assoc iation. TOD Ti m e o f d a y tone ringer A devic e with a sp eaker, used in elec tronic voic e terminals to alert the user. TOP Task-oriented p rotocol trunk A ded ic ated telec ommunic ations channel b etween two c ommunic ations systems or COs. trunk allocation The manner in which trunks are selected to form wid eband c hannels. trunk-data module A devic e that c onnects off-p remises p rivate-line trunk fac ilities and DEFINITY ECS. The trunk-d ata mod ule c onverts between the RS-232C and the DCP, and c an c onnec t to DDD mod ems as the DCP memb er of a mod em p ool.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-49 trunk group Telec ommunic ations c hannels assig ned as a g roup for certain func tions that c an b e used interc hangeably b etween two communications systems or COs. TSC Technic al Servic e Center TTI Terminal translation initialization TTR Touc h-tone rec eiver TTT Terminating trunk transmission TTTN See tand em tie-trunk network (TTTN) . TTY Teletyp ewriter U UAP Usag e-allocation plan UART Universal async hronous transmitter UCD Uniform c all d istribution UCL Unrestric ted c all list UDP See Uniform Dial Plan (UDP) . UL Und erwriter Lab oratories UM User manag er Uniform Dial Plan (UDP) A feature that allows a uniq ue 4- or 5-d ig it number assig nment for eac h terminal in a multiswitc h config uration such as a DCS or main-satellite-trib utary system. UNMA Unified Network Management Architec ture UNP Uniform numb ering p lan UPS Uninterruptible power supply
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-50 USOP User service-ord er p rofile UUCP UNIX-to-UNIX Communications Protocol UUI User-to-user information V VA R Value-add ed reseller VDN See vector direc tory number (VDN) . vector directory number (VDN) An extension that p rovid es acc ess to the Vec toring feature on the switc h. Vectoring allows a customer to sp ec ify the treatment of incoming c alls b ased on the d ialed number. vector-controlled split A hunt g roup or ACD sp lit ad ministered with the vec tor field enab led . Acc ess to such a sp lit is p ossible only by d ialing a VDN extension. VIS Voice Information System VLSI Very-larg e-scale integ ration VM Vo l t m e t e r VNI Virtual nod ep oint id entifier voice terminal A sing le-line or multiap pearance telephone. W WAT S See Wid e Area Telec ommunic ations Service (WATS) . WCC World -Class Core WCR World -Class Routing WCTD World -Class Tone Detec tion
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-51 WFB Wireless fixed base Wide Area Telecommunications Service (WATS) A servic e in the United States that allows calls to certain areas for a flat-rate c harg e b ased on exp ec ted usage. wideband A c irc uit-switc hed c all at a d ata rate g reater than 64 kb ps. A c ircuit-switc hed call on a sing le T1 or E1 facility with a b and wid th between 128 and 1536 (T1) or 1984 (E1) kbp s in multip les of 64 kb p s. H0, H11, H12, and N x DS0 c alls are wideb and . wideband access endpoint Acc ess endp oints, extend ed with wid eb and switc hing to include wid eb and ac cess end p oints. A wid eb and ac cess end point consists of one or more c ontig uous DS0s on a line-side T1 or E1 fac ility and has an extension. The Ad ministered Connec tions feature p rovid es c all c ontrol for c alls orig inating from wid eband ac cess end points. wink-start tie trunk A trunk with which, after making a connec tion with a d istant switc hing system for an outgoing c all, the system waits for a momentary signal (wink) before send ing the d ig its of the c alled numb er. Similarly, on an incoming c all, the system send s the wink sig nal when read y to receive d ig its. work mode One of four states (Auto-In, Manual-In, ACW, AUX-Work) that an ACD ag ent can be in. Up on log g ing in, an ag ent enters AUX-Work mod e. To b ec ome availab le to receive ACD calls, the ag ent enters Auto-In or Manual-In mod e. To d o work assoc iated with a c ompleted ACD call, an agent enters ACW mod e. work state An ACD ag ent may b e a memb er of up to three d ifferent sp lits. Each ACD ag ent c ontinuously exhib its a work state for every sp lit of whic h it is a member. Valid work states are Avail, Unstaffed, AUX-Work, ACW, ACD (answering an ACD call), ExtIn, ExtOut, and OtherSp l. An agent’s work state for a particular sp lit may c hang e for a variety of reasons (examp le: when a c all is answered or ab and oned , or the ag ent c hang es work mod es). The BCMS feature monitors work states and uses this information to p rovid e BCMS reports. write operation The process of p utting information onto a storag e med ium, suc h as a hard d isk. WSA Waiting session ac c ep t WSS Wireless Subscrib er System Z ZCS Zero Cod e Sup p ression
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Glossary and Abbreviations GL-52
Index IN-1 DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 IN Index Numerics 1110A2 App aratus Mounting Frame,2-10 1110C1 cable support,2-111145B power supply,5-461146B T Cab le,5-50 1146B p ower d istrib ution unit,5-49, 5-531147B b attery,5-491148B b attery,5-49 1149B b attery,5-491151A loop rang e,5-571151A1 Power Sup p ly,5-55, 5-56 1151A2 Power Sup p ly,5-55, 5-562.5 amp hour b atteries,5-472.5 Amp Hour b attery,5-49 26B1 Selec tor Console,5-162-wire d ig ital station wiring examp le,5-5300A sing le-mod e transc eiver,A-3 367A ad apter,5-635 Amp Hour b attery,5-49572 printer,B-4 7400 Series Data Mod ule,1-48 Amp Hour b attery,5-49909A/B Universal Coupler,1-4 9823A multi-mod e transc eiver,A-3, A-159823B multi-mod e transc eiver,A-3, A-15 A AC power g round wiring AC ,1-8to1-9 g round ing,1-7sing le p hase,1-6 three-p hase,1-6Ac c ess Sec urity Gateway,E- 1 AC-powered system,3-14ac tivate the system,3-12ad ap ter 258A ,2-30356A,2-31400B2,5-4 451A,2-29BR2580A,2-30ZD8AJ,2-32 adding circuit packs,5-65CO trunk,5-71, 5-74 code calling access,5-78DID trunk,5-71DS1 tie trunk,5-74 FX trunk,5-71, 5-74 ad d ing , (c ontinued ) OPS trunk ,5-74PCOL trunk,5-71p ooled mod em,5-79 sp eec h synthesis,5-78tie trunk,5-72WATS trunk,5-71, 5-74 ad junc t p ower,5-4, 5-5Ad ministration IP Trunk mod e,5-135 MedPro mod e,5-126alarm c onnections,5-17 relay contac t,5-17wiring examp le,5-5alarms categories ,4-11levels,4-11log of,3-19 Terminal Alarm Notific ation,4-12warning,4-11A-Law c ompanding,3-18 analog station 2-wire,5-5wiring examp le,5-5 analog tie trunk wiring examp le,5-6announcement d elete p roced ure ,6-3integ rated test p roced ure,6-3playback procedure,6-3 rec ord p roc edure,6-3APP c onnec tor information,5-152, 5-162to5-164, D-1 ap p roved floor g round s,1-23ap p roved g round,1-22ap p roved g round s,1-8 Argentina country code,3-19ASG,E- 1 attend ant c onsole,5-3302C1,5-3example wiring,5-3 maximum cabling distance,5-3test p roc edure,6-2 attend ant c onsole, LEDs,4-12attenuators sing le-mod e,A-7 Aud ichron H9040 Wake-Up Announcement System,1-4AUDIX important caution ab out p owering down ,3-19Australia country code ,3-19Auxiliary cabinet AC to DC power supply,1-4Auxiliary cab inet DC c onnec tor b loc k,1-4 Auxiliary cab inet fuse panel,1-4Auxiliary cabinet power receptacle strip,1-4auxiliary c onnector outp uts,5-10
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Index IN-2 auxiliary eq uip ment p in d esig nations,5-152, 5-162to5-164, D-1 B back-up battery,5-47 back-up battery, PEC codes,5-49b ac kup translations,3-49b asic rate interface see also BRI test p roc edure ,6-5b attery 1147B ,5-491148B,5-491149B,5-49 b attery bac k-up,5-49b attery bac k-up switc h,5-50b attery holdover,1-12 Battery Interfac e Unit (BIU),1-16b attery leads,1-12Belg ium country code ,3-19b it rate setting,B-11 BRI multipoint cabling distances,5-63terminating resistor,5-58 test p roc edure,6-5BRI terminating resistor,5-58BU3200A Battery Interface Unit,1-17 C cab inet attac hing to floor,1-35 cable clamps,2-5, 2-12d efinition of,4-1, 4-7, 4-8cab inet form,3-28 cab inet stab ilizing b olts,1-3, 1-4cab le c lamp s,2-5, 2-12 cable ductwork,1-3, 1-33Cab le Slac k Manager,2-5, 2-11cables 25-pair I/O ,2-5, 2-12diagrams,5-152, 5-162to5-164, D-1fiber-optic,1-28 outputs for c ontrol c arrier,5-10wall field,2-5, 2-12cabling fib er optic d istanc es ,A-2Call Detail Rec ording (CDR),B-4calling q ueue,5-46 caution safeg uard ing craft p assword,3-20 CDR,B-4 op tion setting s,B-7printer,B-4chang ing system-parameters c ountry options ,3-17system-parameters maintenanc e,3-24Channel Servic e Unit c ab ling to DS1 Converter ,5-28, 5-29, 5-150Sm ar t Ja c ks,5-150Channel Servic e Unit (CSU),1-4 China country code,3-19circuit pack configuration test p roc edure ,4-2test p roc edure, c ircuit p ac ks c onfiguration test proc ed ure,4-10 circuit packs adding,5-65 c onfig uration test p roc edure,4-2digital line,3-7DS1 Converter LEDs,4-13 d up lic ation interfac e LEDs,4-13expansion interfac e (EI) LEDs,4-13g reen LEDs,4-12 ISDN wiring,5-12LEDs,4-12maintenanc e/test LEDs,4-15 NT1 wiring,5-12p in d esig nations,5-152, 5-162to5-164, D-1red LEDs,4-12 sorted by cod e,5-65SYSA M,4-15TN1654 DS1 CONV,5-21, 5-22 TN2183 Analog Line,5-45TN2185 ISDN-BRI 4-wire S Interfac e,5-154TN2198 2-wire U Interface,5-155 TN2198 circuit p ack wiring,5-12 TN2224 Dig ital Line,5-12, 5-156, 5-161tone-c loc k LEDs,4-15yellow LEDs,4-12 clamps, cable,2-5, 2-12C-LAN c ircuit p ack,5-91 cleaning fiber optic cables,A-16CO trunk,B-11 wiring examp le,5-5CO trunk, ad ding,5-71, 5-74code calling access, adding,5-78 commands list config uration,4-10manag ement terminal introd uc tion,3-15 refresh sp e,4-6reset system interchang e,4-6set exp ansion-link,4-10 set tone-c lock,4-9status system all-c ab inets,4-6, 4-9, 4-10test b oard,4-7 test inad s-link,6-4