Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-57 1151A1 Power Supply 
    5
    !CAUTION:
    The p ower sup p ly c an be used  only with telec ommunic ations equip ment, 
    indoors, and  in a c ontrolled  environment.
    The power supply has a single output of -48 VDC, 0.4 Amps, and can operate 
    from either a 120 VAC 60 Hz power source (105 to 129 VAC) or a 220/230/240 
    VAC 50 Hz power source (198 to 264 VAC). Input voltage selection is automatic. 
    The output capacity is 19.2 Watts.
    The power supply can be placed on a flat surface such as a desk. For 
    wall-mounting, keyhole slots are provided on the bottom of the chassis.
    !CAUTION:
    Do not loc ate the unit within 6 inc hes (15.2 c m) of the floor.
    Connect the 1151A1 or 1151A2 Power Supplies
    The 1151A1 is a standard (no battery backup) power supply unit. The 1151A2 is a 
    battery backup version of the 1151A1. Either power supply can suppor t 1 
    telephone with or without an adjunct. The maximum loop range is 250 feet (76 
    meters). Two modular jacks are used. Power is provided on the PHONE jack, pins 
    7 and 8 (- and +, respectively).
    The PHONE and LINE jacks are 8-pin female non-keyed 657-type jacks that can 
    accept D4, D6, and D8 modular plug cables. Figure 5-25
     shows an 1151A1/2 
    Power Supply. 
    Figure 5-25. 1151A1/2 Power Supply — Front
    pwr_sup1 CJL 051496 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-58 BRI Terminating Resistor 
    5
    BRI Terminating Resistor
    The resistors balance the cable plant between the receiver and the transmitter on 
    the interface. When using the TN2198 ISDN-BRI 2-Wire U Interface circuit pack, 
    an NT1 is required. A terminating resistor is always required near the terminal 
    when the BRI S-type interface circuit pack (TN556 BRI 4-Wire S-NT Line circuit 
    pack) is used (see 
    #5ESS Switch Integrated Services Digital Network Customer 
    Premises Planning Guide
    , 533-700-100).
    The resistor is built into the NT1 and can be 1 of 3 values, depending on the 
    configuration and the distance from the NT1 to the ISDN terminal. The resistor 
    value is controlled from the NT1. A terminating resistor adapter may be needed 
    near the terminal and can be placed in the satellite closet or work location.
    NOTE:
    The 440A4 terminating  resistor and  110RA1-12 terminating  resistor b loc k 
    are UL listed . Most new installations are the 110RA1-12 terminating  resistor 
    b loc k. The following  installation instruc tions should b e ob served .
    nNever install telephone wiring during a lightning storm.
    nNever install telephone jacks in wet locations unless the jack is specifically 
    designed for wet locations.
    nNever touch uninsulated wires or terminals unless the telephone line has 
    been disconnected at the network interface.
    nUse caution when installing or modifying telephone lines.
    Terminating Resistor Adapter
    Figure 5-26 shows an 8-pin 440A4 terminating resistor adapter. The adapter is 3 
    inches (7.6 cm) long with an 8-wide plug at 1 end, a short cord, and an 8-wide jack 
    at the opposite end. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-59 BRI Terminating Resistor 
    5
    Figure 5-26. 8-Wide Terminating Resistor Adapter (440A4)
    Closet Mounted (110RA1-12)
    The 110RA1-12 terminating resistor block is designed to mount in the 
    telecommunications wire closet. It consists of twelve 2-pair circuits and provides 
    the 100 Ohm termination used for ISDN-BRI circuits.
    Figure 5-27
     shows the wiring of the 110RA1-12. Three rows of 110D-4 connector 
    blocks are mounted on a printed wire board along with circuit resistors and 
    capacitors. The bottom row is designated as the input row and the top and middle 
    rows are designated as the output rows. The circuit assembly is mounted on a 
    standard 110A-100 pair mounting base. The 110RA1-12 is shipped with 
    preprinted designation strips to simplify circuit identification and installation. Figure Notes
    1. 8-Wid e Plug
    2. Cord3. Plastic  Housing
    4. 8-Wide Jac k
    1
    2
    3
    4
    5
    6
    7
    81
    2
    3
    4
    5
    6
    7
    8
    3
    41
    2
    R RCC 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-60 BRI Terminating Resistor 
    5
    Figure 5-27. Terminating Resistor Block (110RA1-12)
    Figure 5-28
     shows the wiring connections for the 110RA1-12 terminal block. The 
    TN556 Basic Rate Interface (BRI) switch port is terminated to bottom row C.  Figure Notes
    1. Circuit 1
    2. Circ uit 12
    3.Outp ut Row “A”
    4. Output Row “B”5. Inp ut Row “ C”
    6. Only First Circ uit Shown to All 12 Circ uits (2APR) 
    Pe r  Bl o c k
    7. 110D-4 Connec tor Bloc k
    8. Printed  Circ uit Board  Mounted  on Stand ard  110A 
    or 100APR Bloc k
    3
    8
    4
    5
    1
    6
    2
    7 145246347448 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-61 BRI Terminating Resistor 
    5
    Figure 5-28. Typical Installation of Terminating Resistor Block (110RA1-12)
    For point-to-point wiring, the top row connects to the blue station field. The pair 
    connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the 
    110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3 of 
    the station field.
    Two terminal basic multipoint applications are accommodated by connecting row 
    B (output) to the second terminal common to the multipoint circuit. Figure Notes
    1. Part of Terminating  Resistor Bloc k
    2. White or Purple Field
    3. Part of 4-Pair Blue Field
    4. From ISDN T-interface Circ uit (2-Pair)
    5. To ISDN S/T-interfac e terminals
    6. 2-Pair Cross-Connec t7. Basic Multi-p oint Op tion
    8. 2-Pair Cross-Connec t
    9. 4-Pair Horizontal Cab les
    10.Row “ A”
    11. Row “ B”
    12. Row “ C”
    TT1RR1
    10
    3
    45
    1
    6
    2
    8
    12
    9
    11
    7 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-62 Multi-point Adapters 
    5
    Multi-point Adapters
    Multi-point Adapters are used to provide signal fanout of the T-interface. Fanout 
    can be performed at the work station by the BR851-B or the 367A. These 
    adapters support more than one ISDN terminal per horizontal 4-pair D-inside wire 
    (DIW). To support multiple horizontal runs, perform fanout in the satellite closet by 
    an MDF with multiple common rows. The 110RA1-12 provides fanout for 2 
    horizontal runs and contains the 100 Ohm terminating resistor. This can be used 
    for Basic Multi-point or point-to-point with terminating resistor in the closet. Other 
    fanout blocks include the 110AB1-025M and the 110AB1-050M.
    BR851-B Adapter (T-Adapter)
    The BR851-B supports 2 terminals on 1 multi-point BRI at the work station. It is a 
    T-shaped device used to fanout transmission and power. The BR851-B is an 8-pin 
    device with a single plug and 2 jacks. See Figure 5-29
    .
    Figure 5-29. Wiring Diagram of BR851-B Figure Notes
    1. Wire Pairs
    2. Pin Numbers
    3. Modular Plug (Male)4. Female
    5. Two 8-p in Modular Jac ks
    6. T-Typ e Ad ap ter
    3
    44
    5
    11
    1
    22
    2
    44 4
    RR R
    88 8
    44 4
    TT T
    77 7
    33 3
    RR R
    66 6
    11 1
    TT T
    55 5
    11 1
    RR R
    44 4
    33 3
    TT T
    33 3
    22 2
    RR R
    22 2
    22 2
    TT T
    11 16 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-63 Multi-point Adapters 
    5
    367A Adapter
    The 367A adapter provides fanout. See Figure 5-30. It can provide inputs to up to 
    7 terminals. The 367A is an 8-conductor adapter and can be is used at the work 
    location for bridging 3 to 7 terminals.
    Figure 5-30. Wiring Diagram of 367A
    Basic Multipoint Installation Distances
    Figure 5-31 provides cabling information for fan-out of ISDN-BRI multi-point 
    installations. The terminating resistor is generally located in the satellite closet. All 
    distances assume 24 AWG (#5) (0.26 mm
    2) D-Inside Wire (DIW). Figure Notes
    1. Jack 1
    2. Jack 23. Jac k 8
    4. 367A Ad ap ter
    312 88 877 766 655 544 433 322 211 1
    4 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-64 Multi-point Adapters 
    5
    Figure 5-31. Basic Multi-point with 1 Work Location Figure Notes
    1. S-Interfac e Sourc e (TN556)
    2. Terminating  Resistor
    3. Satellite Closet
    4. Maximum Distanc e from S-Interfac e 
    Sourc e to Work Loc ation (1600 Feet) 
    (488 m)
    5. Maximum Distance From Satellite 
    Closet to Work Loc ation (250 Feet) 
    (76 m)6. System Cab inet
    7. Terminating Endpoint 1
    8. Terminating Endpoint 2
    9. Work Loc ation
    10. Maximum Distanc e from 
    Information Outlet to Terminating  
    Endpoint (33 Feet) (10 m)
    11. Information Outlet (Brid g ed  Tap)
    2
    38
    9
    7
    110
    11
    11
    5
    4
    6
    inst_dis CJL 030796 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-65 Add Circuit Packs 
    5
    Add Circuit Packs
    When installing additional features or equipment, it may be necessary to install 
    additional port circuit packs. See Table 5-19
     for a list of circuit packs. This is a 
    general procedure to use when adding features or equipment that require adding 
    circuit packs.
    !CAUTION:
    The c ontrol c irc uit p ac ks with white lab els c annot b e removed  or installed  
    when the power is on. The port circuit packs with gray labels (older version 
    circuit packs had purple labels) can be removed or installed when the 
    p ower is on.
    1. Log  onto the system and  answer y
     to the Sup p ress Alarm Orig ination 
    q uestion d uring  log in.
    2. Install the c irc uit p ac k into the c arrier.
    3. Log  off the system after the ad dition (and  any req uired  ad ministration) is 
    complete.
    NOTE:
    If North Americ an and  non-United  States c irc uit p ac ks ap p ear in the 
    same row of a tab le, those c irc uit p ac k c odes ord inarily used  in 
    North Americ a ap p ear in b old  font to help  d isting uish these c irc uit 
    p ac ks from their non-United  States c ounterp arts. If only c irc uit p ac ks 
    c ommonly used  for non-United  States ap p lic ations ap p ear in a row 
    of a tab le, the c irc uit-p ac k c odes are enc losed  in p arentheses. If 
    only c irc uit p ac ks c ommonly used  in North Americ a ap p ear in a row 
    of a tab le, the c irc uit p ac k c od es are enc losed  in sq uare brac kets.
    For information about connecting and administering non-United States circuit 
    packs, refer to the Application Notes in 
    DEFINITY Enterprise Communications 
    Server Release 8 Administrator’s Guide
    .
    List of Circuit Packs 
    Table 5-19 lists the circuit packs sorted by apparatus code, including circuit packs 
    used in non-United States installations. For more information on the circuit packs 
    and other equipment, refer to 
    DEFINITY Enterprise Communications Server 
    Release 8 System Description
    . 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-66 List of Circuit Packs 
    5
    Table 5-19. Circuit Packs and Circuit Modules 
    Apparatus 
    Code Name Type
    631DA1 AC Power Unit (MCC) (+ 5V, 60A) Power
    631DB1 AC Power Unit (MCC) (-48V/-5V,8A) Power
    644A1 DC Power Unit (MCC) (+ 5V, 60A) Power
    645B1 DC Power Unit (MCC) (-48V, 8A)  Power
    649A DC Power Unit (MCC) (-5, + 5, -48V)  Power
    982LSCurrent Limiter for si only (PPN) Power
    CFY1BCurrent Limiter for r only Power
    CPP1 Memory Expansion  Control
    ED - 1 E5 4 6 -7 0
    (TN2169)
    (TN2170)
    (TN566)
    (TN567)DEFINITY AUDIX R3 (Circ uit-Pac k Assemb ly) (b eing  
    rep lac ed  by ED-1E568Ap p lication
    ED - 1 E5 4 6 -7 0
    (TN2208)
    (TN2170)CallVisor ASAI/DEFINITY LAN Gateway R1 
    (Circ uit-Pac k Assemb ly)Ap p lication
    J58890MA-1
    (TN801)Multi Ap plic ation Platform DEFINITY (Circ uit Pac k 
    Assemb ly)
    List 2 for Call Visor, ASAI, LAN Gateway R2
    List 10 for IP Trunk
    List 20 for CV ASAI, CentreVu Comp uter Telep hony, 
    BCMS Vu
    List 30 for IP Solutions Ap p lication
    TN417 Auxiliary Trunk (rep lac ed by TN763D)Tru nk
    TN419BTone-Cloc k (Italy, Australia and  the United  King d om, 
    rep lac ed  by TN2182B)Control
    TN420B/CTone Detec tor (rep lac ed  b y TN2182B or TN744D)Se r v ic e
    TN429/B Direc t Inward /Outward Dialing  (DIOD) Trunk 
    (Japan)Po r t
    TN429C/D Analog  Central Offic e Trunk 
    (with CAMA)Po r t
    TN429D Analog  DIOD Trunk - Analog  Loop  Start Port
    TN433 Speech Synthesizer 
    (Italian)Se r v ic e
    Continued on next page 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual