Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-57 1151A1 Power Supply 5 !CAUTION: The p ower sup p ly c an be used only with telec ommunic ations equip ment, indoors, and in a c ontrolled environment. The power supply has a single output of -48 VDC, 0.4 Amps, and can operate from either a 120 VAC 60 Hz power source (105 to 129 VAC) or a 220/230/240 VAC 50 Hz power source (198 to 264 VAC). Input voltage selection is automatic. The output capacity is 19.2 Watts. The power supply can be placed on a flat surface such as a desk. For wall-mounting, keyhole slots are provided on the bottom of the chassis. !CAUTION: Do not loc ate the unit within 6 inc hes (15.2 c m) of the floor. Connect the 1151A1 or 1151A2 Power Supplies The 1151A1 is a standard (no battery backup) power supply unit. The 1151A2 is a battery backup version of the 1151A1. Either power supply can suppor t 1 telephone with or without an adjunct. The maximum loop range is 250 feet (76 meters). Two modular jacks are used. Power is provided on the PHONE jack, pins 7 and 8 (- and +, respectively). The PHONE and LINE jacks are 8-pin female non-keyed 657-type jacks that can accept D4, D6, and D8 modular plug cables. Figure 5-25 shows an 1151A1/2 Power Supply. Figure 5-25. 1151A1/2 Power Supply — Front pwr_sup1 CJL 051496
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-58 BRI Terminating Resistor 5 BRI Terminating Resistor The resistors balance the cable plant between the receiver and the transmitter on the interface. When using the TN2198 ISDN-BRI 2-Wire U Interface circuit pack, an NT1 is required. A terminating resistor is always required near the terminal when the BRI S-type interface circuit pack (TN556 BRI 4-Wire S-NT Line circuit pack) is used (see #5ESS Switch Integrated Services Digital Network Customer Premises Planning Guide , 533-700-100). The resistor is built into the NT1 and can be 1 of 3 values, depending on the configuration and the distance from the NT1 to the ISDN terminal. The resistor value is controlled from the NT1. A terminating resistor adapter may be needed near the terminal and can be placed in the satellite closet or work location. NOTE: The 440A4 terminating resistor and 110RA1-12 terminating resistor b loc k are UL listed . Most new installations are the 110RA1-12 terminating resistor b loc k. The following installation instruc tions should b e ob served . nNever install telephone wiring during a lightning storm. nNever install telephone jacks in wet locations unless the jack is specifically designed for wet locations. nNever touch uninsulated wires or terminals unless the telephone line has been disconnected at the network interface. nUse caution when installing or modifying telephone lines. Terminating Resistor Adapter Figure 5-26 shows an 8-pin 440A4 terminating resistor adapter. The adapter is 3 inches (7.6 cm) long with an 8-wide plug at 1 end, a short cord, and an 8-wide jack at the opposite end.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-59 BRI Terminating Resistor 5 Figure 5-26. 8-Wide Terminating Resistor Adapter (440A4) Closet Mounted (110RA1-12) The 110RA1-12 terminating resistor block is designed to mount in the telecommunications wire closet. It consists of twelve 2-pair circuits and provides the 100 Ohm termination used for ISDN-BRI circuits. Figure 5-27 shows the wiring of the 110RA1-12. Three rows of 110D-4 connector blocks are mounted on a printed wire board along with circuit resistors and capacitors. The bottom row is designated as the input row and the top and middle rows are designated as the output rows. The circuit assembly is mounted on a standard 110A-100 pair mounting base. The 110RA1-12 is shipped with preprinted designation strips to simplify circuit identification and installation. Figure Notes 1. 8-Wid e Plug 2. Cord3. Plastic Housing 4. 8-Wide Jac k 1 2 3 4 5 6 7 81 2 3 4 5 6 7 8 3 41 2 R RCC
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-60 BRI Terminating Resistor 5 Figure 5-27. Terminating Resistor Block (110RA1-12) Figure 5-28 shows the wiring connections for the 110RA1-12 terminal block. The TN556 Basic Rate Interface (BRI) switch port is terminated to bottom row C. Figure Notes 1. Circuit 1 2. Circ uit 12 3.Outp ut Row “A” 4. Output Row “B”5. Inp ut Row “ C” 6. Only First Circ uit Shown to All 12 Circ uits (2APR) Pe r Bl o c k 7. 110D-4 Connec tor Bloc k 8. Printed Circ uit Board Mounted on Stand ard 110A or 100APR Bloc k 3 8 4 5 1 6 2 7 145246347448
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-61 BRI Terminating Resistor 5 Figure 5-28. Typical Installation of Terminating Resistor Block (110RA1-12) For point-to-point wiring, the top row connects to the blue station field. The pair connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the 110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3 of the station field. Two terminal basic multipoint applications are accommodated by connecting row B (output) to the second terminal common to the multipoint circuit. Figure Notes 1. Part of Terminating Resistor Bloc k 2. White or Purple Field 3. Part of 4-Pair Blue Field 4. From ISDN T-interface Circ uit (2-Pair) 5. To ISDN S/T-interfac e terminals 6. 2-Pair Cross-Connec t7. Basic Multi-p oint Op tion 8. 2-Pair Cross-Connec t 9. 4-Pair Horizontal Cab les 10.Row “ A” 11. Row “ B” 12. Row “ C” TT1RR1 10 3 45 1 6 2 8 12 9 11 7
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-62 Multi-point Adapters 5 Multi-point Adapters Multi-point Adapters are used to provide signal fanout of the T-interface. Fanout can be performed at the work station by the BR851-B or the 367A. These adapters support more than one ISDN terminal per horizontal 4-pair D-inside wire (DIW). To support multiple horizontal runs, perform fanout in the satellite closet by an MDF with multiple common rows. The 110RA1-12 provides fanout for 2 horizontal runs and contains the 100 Ohm terminating resistor. This can be used for Basic Multi-point or point-to-point with terminating resistor in the closet. Other fanout blocks include the 110AB1-025M and the 110AB1-050M. BR851-B Adapter (T-Adapter) The BR851-B supports 2 terminals on 1 multi-point BRI at the work station. It is a T-shaped device used to fanout transmission and power. The BR851-B is an 8-pin device with a single plug and 2 jacks. See Figure 5-29 . Figure 5-29. Wiring Diagram of BR851-B Figure Notes 1. Wire Pairs 2. Pin Numbers 3. Modular Plug (Male)4. Female 5. Two 8-p in Modular Jac ks 6. T-Typ e Ad ap ter 3 44 5 11 1 22 2 44 4 RR R 88 8 44 4 TT T 77 7 33 3 RR R 66 6 11 1 TT T 55 5 11 1 RR R 44 4 33 3 TT T 33 3 22 2 RR R 22 2 22 2 TT T 11 16
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-63 Multi-point Adapters 5 367A Adapter The 367A adapter provides fanout. See Figure 5-30. It can provide inputs to up to 7 terminals. The 367A is an 8-conductor adapter and can be is used at the work location for bridging 3 to 7 terminals. Figure 5-30. Wiring Diagram of 367A Basic Multipoint Installation Distances Figure 5-31 provides cabling information for fan-out of ISDN-BRI multi-point installations. The terminating resistor is generally located in the satellite closet. All distances assume 24 AWG (#5) (0.26 mm 2) D-Inside Wire (DIW). Figure Notes 1. Jack 1 2. Jack 23. Jac k 8 4. 367A Ad ap ter 312 88 877 766 655 544 433 322 211 1 4
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-64 Multi-point Adapters 5 Figure 5-31. Basic Multi-point with 1 Work Location Figure Notes 1. S-Interfac e Sourc e (TN556) 2. Terminating Resistor 3. Satellite Closet 4. Maximum Distanc e from S-Interfac e Sourc e to Work Loc ation (1600 Feet) (488 m) 5. Maximum Distance From Satellite Closet to Work Loc ation (250 Feet) (76 m)6. System Cab inet 7. Terminating Endpoint 1 8. Terminating Endpoint 2 9. Work Loc ation 10. Maximum Distanc e from Information Outlet to Terminating Endpoint (33 Feet) (10 m) 11. Information Outlet (Brid g ed Tap) 2 38 9 7 110 11 11 5 4 6 inst_dis CJL 030796
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-65 Add Circuit Packs 5 Add Circuit Packs When installing additional features or equipment, it may be necessary to install additional port circuit packs. See Table 5-19 for a list of circuit packs. This is a general procedure to use when adding features or equipment that require adding circuit packs. !CAUTION: The c ontrol c irc uit p ac ks with white lab els c annot b e removed or installed when the power is on. The port circuit packs with gray labels (older version circuit packs had purple labels) can be removed or installed when the p ower is on. 1. Log onto the system and answer y to the Sup p ress Alarm Orig ination q uestion d uring log in. 2. Install the c irc uit p ac k into the c arrier. 3. Log off the system after the ad dition (and any req uired ad ministration) is complete. NOTE: If North Americ an and non-United States c irc uit p ac ks ap p ear in the same row of a tab le, those c irc uit p ac k c odes ord inarily used in North Americ a ap p ear in b old font to help d isting uish these c irc uit p ac ks from their non-United States c ounterp arts. If only c irc uit p ac ks c ommonly used for non-United States ap p lic ations ap p ear in a row of a tab le, the c irc uit-p ac k c odes are enc losed in p arentheses. If only c irc uit p ac ks c ommonly used in North Americ a ap p ear in a row of a tab le, the c irc uit p ac k c od es are enc losed in sq uare brac kets. For information about connecting and administering non-United States circuit packs, refer to the Application Notes in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . List of Circuit Packs Table 5-19 lists the circuit packs sorted by apparatus code, including circuit packs used in non-United States installations. For more information on the circuit packs and other equipment, refer to DEFINITY Enterprise Communications Server Release 8 System Description .
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-66 List of Circuit Packs 5 Table 5-19. Circuit Packs and Circuit Modules Apparatus Code Name Type 631DA1 AC Power Unit (MCC) (+ 5V, 60A) Power 631DB1 AC Power Unit (MCC) (-48V/-5V,8A) Power 644A1 DC Power Unit (MCC) (+ 5V, 60A) Power 645B1 DC Power Unit (MCC) (-48V, 8A) Power 649A DC Power Unit (MCC) (-5, + 5, -48V) Power 982LSCurrent Limiter for si only (PPN) Power CFY1BCurrent Limiter for r only Power CPP1 Memory Expansion Control ED - 1 E5 4 6 -7 0 (TN2169) (TN2170) (TN566) (TN567)DEFINITY AUDIX R3 (Circ uit-Pac k Assemb ly) (b eing rep lac ed by ED-1E568Ap p lication ED - 1 E5 4 6 -7 0 (TN2208) (TN2170)CallVisor ASAI/DEFINITY LAN Gateway R1 (Circ uit-Pac k Assemb ly)Ap p lication J58890MA-1 (TN801)Multi Ap plic ation Platform DEFINITY (Circ uit Pac k Assemb ly) List 2 for Call Visor, ASAI, LAN Gateway R2 List 10 for IP Trunk List 20 for CV ASAI, CentreVu Comp uter Telep hony, BCMS Vu List 30 for IP Solutions Ap p lication TN417 Auxiliary Trunk (rep lac ed by TN763D)Tru nk TN419BTone-Cloc k (Italy, Australia and the United King d om, rep lac ed by TN2182B)Control TN420B/CTone Detec tor (rep lac ed b y TN2182B or TN744D)Se r v ic e TN429/B Direc t Inward /Outward Dialing (DIOD) Trunk (Japan)Po r t TN429C/D Analog Central Offic e Trunk (with CAMA)Po r t TN429D Analog DIOD Trunk - Analog Loop Start Port TN433 Speech Synthesizer (Italian)Se r v ic e Continued on next page