Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-45 Patch Cord/Jumper Installation and Administration 2 Figure 2-24. Label Graphic Symbols and Nomenclature Eac h 110-typ e lab el id entifies 2 rows on the 110-typ e terminal b loc k. The up p er half id entifies the row ab ove it and the lower half id entifies the row b elow it. The labels are inserted into the c lear p lastic d esig nation strip s furnished with the 110-typ e terminal b loc ks. The strip is snap p ed in p lac e b etween the terminal b loc k rows. Lab el c od e numb er 220A (c omc od e 103970000) c ontains all of the 110-typ e lab els. Patch Cord/Jumper Installation and Administration Before starting the p atc h c ord installation, ob tain a c opy of the Port Assig nment Rec ord forms from the c ustomer or marketing rep resentative. See Fi g u re 2 - 2 5 . These forms c ontain the p ort assig nments and id entify the extension numb ers (Te r m i n a l N o . ) of the telephones/voic e terminals. Enter the jac k assig nments at the eq uip ment room and ind ic ate if ad junc t p ower is req uired and where it is p rovid ed (MDF, site/satellite c loset, or information outlet).Figure Notes: 1. Write Floor or Building Id entific ation on Lab el 2. Cab inet 3. Carrier 4. Slot5. Information Outlet 6. Site/Satellite Closet 7. Tie Circ uit 8. Floor 9. Build ing r758422i LJK 050996
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-46 Patch Cord/Jumper Installation and Administration 2 Figure 2-25. Port Assignment Record Form When satellite loc ations are p rovid ed , enter the satellite letter desig nation (“ A” throug h “ F” ) and the jac k ap p earanc e in the eq uip ment room on the form. Also, enter the floor d esig nation and /or b uild ing d esig nation if ap prop riate. For 1-p oint ad ministration, this entry is all that is req uired. Labeling The white lab el id entifying the terminal b loc k row assoc iated with c irc uits 17 to 24 c onnec ts to an id entic ally lab eled terminal b loc k row at the satellite c loset. See Fi g u re 2 - 2 6 . This is always the c ase for either 1-p oint or 2-p oint ad ministration. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Slot CKT PK Ty p eSlot Port Jack* Old New Type Color Module Power* User Name/Use Extension NumberVo i c e Te r m i n a l Bldg Flr RmVo i c e Terminal Adjunct CARRIERPage PORT ASSIGNMENT RECORD * To be completed by installation technician r764787 PDH 071596
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-47 Patch Cord/Jumper Installation and Administration 2 Figure 2-26. Example 3-Pair Labeling to Information Outlet The satellite symb ol must be installed at all c onnec tion p oints b etween the b lue field and the information outlet. It must also be installed at the information outlet itself.Figure Notes: 1. Eq uip ment Room 2. Satellite Loc ation 3. Work Loc ation 4. White Row on 110 Terminal Bloc k 5. Purple Row on 110 Terminal Block 6. Blue Row on 110 Terminal Bloc k 7. Central Location for Terminals 1 through 68. D-Insid e Wire Cut Down to Connec ting Bloc k 9. 258A Ad ap ter 10. Information Outlet 11. Voic e Terminal 12. To Port Connec tor on Cab inet (Cabinet 1, Carrier A, Slot 03) crdf5pr CJL 103096
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-48 Patch Cord/Jumper Installation and Administration 2 Fi g u re 2 - 2 7 shows an examp le labeling sc heme for 4-p air c irc uits from the eq uip ment room to the information outlets. The lab eling sc heme for 3-pair c irc uits from the MDF to a satellite loc ation. Figure 2-27. Example 4-Pair Labeling to Information Outlet Figure Notes: 1. Eq uip ment Room 2. To Central Loc ation for Terminals 1 throug h 6 3. Blue Row on 110 Terminal Bloc k 4. Purple Row on 110 Terminal Block 5. To Port Connec tor on Cab inet (Cab inet 1, Carrier A, Slot 03)6. 258A Ad ap ter 7. D-Insid e Wire Cut Down to Connec ting Bloc k 8. Information Outlet 9. Voice Terminal crdf4pr CJL 102996
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-49 Create a Provisioning Plan 2 Create a Provisioning Plan Determine an ap p rop riate availab le p ort c irc uit on the system for eac h telep hone, trunk, and p erip heral c onnec tion need ed , and , in ad d ition, p lan for auxiliary p ower for Basic Rate Interfac e (BRI) and c ertain d isp lay sets. Create a Port Assig nment Rec ord to inc lud e the following . See Figure 2-25 . nStation or trunk typ e or feature/servic e nBuild ing loc ation (floor/room/d esk/information outlet) nExtension numb er or trunk group and memb er numb er nPort c irc uit loc ation on the system for eac h end p oint (c ab inet/c arrier/ slot/c irc uit) nRoute from eq uip ment room throug h eq uip ment c losets to eac h end p oint nAuxiliary p ower sup p ly, if req uired
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install Telecommunications Cabling 2-50 Create a Provisioning Plan 2
Accessing and Activating the System 3-1 3 DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 3 Accessing and Activating the System This c hapter c ontains p roc ed ures for installing the PC and b ring ing the system up to a “ no red LEDs” state. This c hap ter d etails how to: nAc cess the System nAc tivate the System nPower Up the System nSc reens and Command s nSystem Administration nSet Country Op tions nChang e Craft Password nSet Date and Time nAd minister System Config urations (Release 8r) nAd minister Fib er Links (Release 8r Only) nSet System Maintenanc e Parameters nSave Translations nInitiate DEFINITY AUDIX Power Proc ed ures !CAUTION: To prevent unnec essary troub le tic kets, d o not enab le the system alarms (Alarm Orig ination feature) b efore c omp leting all installation and ad ministration p roc ed ures. This c hapter d esc rib es b asic system start-up procedures only and is not intended to identify all system alarms or error c ond itions.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-2 Access the System 3 Access the System To administer the DEFINITY ECS, you must be ab le to ac c ess the system. With Release 7 and later, the DEFINITY ECS no long er req uires a d ed ic ated manag ement terminal, known as a system ad ministration terminal, or SAT. Personal c omp uters and tec hnic ian lap top s eq uip p ed with DEFINITY Site Ad ministration (DSA) or DEFINITY Network Ad ministration (DNA) software are the p rimary supp ort ac c ess for system initialization, aftermarket ad d itions, and ong oing maintenanc e. For information on DSA or DNA, g o to http ://www.b c s.luc ent.c om/sales_market/d efinity. SAT is now an op tion. The following sections d escrib e nInstalling and using DSA nConnec ting a PC Installing and using DSA To install DSA, your PC or laptop must meet the minimum req uirements described in Tab le 3-1 : NOTE: For information on DNA, refer to DEFINITY Network Ad ministration Release 2 Installation and Configuration. Table 3-1. Minimum requirements to run DSA Op erating systems: MS Wind ows 95 MS Wind ows 98 MS Wind ows NT 4.0 MS Wind ows 2000Pr o c e ss o r / RAM : 486SL/66/16 MB Pentium/32 MB Pentium/64 MB Pentium-c lass 300 MHz/64 MB Grap hic s ad ap ter SVGA with minimum sc reen resolution of 800 x 600 Floppy disk drive 3-1/2 in. 1.44-MB floppy disk drive CD-ROM CD-ROM d rive (req uired to install DSA from CD) Available hard d isk sp ac e A minimum of 100-MB free hard d isk sp ac e is req uired . The req uirement for d isk sp ac e d ep end s on the size and numb er of c onfig uration d ata sets. Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-3 Access the System 3 To install DSA on your c omp uter, p lac e the DSA CD in the CD-ROM d rive and follow the installation instructions. To start DSA or DNA, click on Start > Programs > DEFINITY Site Administration . DSA sup p orts SAT emulation, whic h is d irec tly eq uivalent to using the SAT (see Fi g u re 3 - 1 ). DSA also sup p orts a whole rang e of other features, inc lud ing the g rap hic ally enhanc ed DEFINITY interfac e (GEDI) (see Fi g u re 3 -2 ) and Data Imp ort. For more information refer to the Help , Guid ed Tour, and Show Me acc essed from the DSA Help menu.Pri n t e r p o rt St a n d a r d PC o r n e t w o r k p r i n t e r p o r t is re q u ir e d for c onnec ting to a p rinter to p rod uc e station button labels. Network ad ap ter May b e req uired for network ac c ess to AUDIX and other network-c onnec ted systems. Free serial p orts One free serial port c ap able of 9600-b p s op eration is req uired for a c onnec tion to eac h serial device (ADU, modem, data module) or d irec t c onnec tion to a DEFINITY ECS. We rec ommend that PCs have at least a 16550A UART or 16550A UART simulator (c apab le of 56 kbp s DTE-sp eed c onnec tions). USB and internal modems should emulate this hardware. A sec ond serial p ort is required for simultaneous c onnec tion to AUDIX throug h a serial c onnec tion. Table 3-1. Minimum requirements to run DSA Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-4 Access the System 3 Figure 3-1. Typical DSA screen in SAT emulation mode Figure 3-2. Typical DSA screen in GEDI mode