Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-77 Add DS1 Tie and OPS 5 4. After the system reb oot is finished and all troub le is c leared , verify that the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Enter Added Translations Administer forms listed under “DS1 Tie Trunk Service” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/standb y” mod e. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard or removab le med ia. 3. If the PPN c ontains a TN750 Announc ement c irc uit p ac k, typ e list configuration software-version and p ress En t e r. If Pag e 2 of this form shows that rec orded announc ements were saved , these announc ements c an b e restored using the restore announc ements command. Type restore announcements and p ress En te r. Resolve Alarms Examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Release 8 Maintenance R8si . Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘ Where to Call for Tec hnic al Sup p ort’’ on page -xvii for telep hone numb ers. NOTE: As p art of the system reg istration p roc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination. 2. When ad ministration is c omp leted , log in as craft at the Login: prompt.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-78 Add Speech Synthesis 5 Add Speech Synthesis The Speech Synthesizer circuit pack is required when the Voice Message Retrieval, Automatic Wakeup, or Do Not Disturb features are activated. The circuit pack does not require administration. 1. Determine the p ort assig nment of the Sp eec h Synthesizer c irc uit p ac k to be added. 2. Install the Sp eec h Synthesizer c irc uit p ac k in the d esig nated c arrier slot. See Figure 5-19 for list of circuit packs. Add Code Calling Access The tones for the Code Calling feature are generated by the Tone-Clock circuit packs in the port networks. 1. Install a TN763B/C/D (or TN417) Auxiliary Trunk c irc uit p ac k or a Sp eec h Synthesizer c irc uit p ac k and c onnec t for Loud sp eaker Pag ing . The Cod e Calling Ac c ess feature shares the same p orts as Loud sp eaker Pag ing . An Auxiliary Trunk c irc uit p ac k p rovid es 4 p orts for Loud sp eaker Pag ing and Cod e Calling Ac c ess. 2. Ad minister the form listed und er “ Cod e Calling Ac c ess” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. init login administration: 1. Log in as init . 2. Type change system-parameters customer-options and press En te r to verify that the c ustomer op tions are p roperly set. 3. Go to sc reen 6, QSIG Op tional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protoc ol b or d on an ISDN-PRI trunk g roup b efore the up g rad e. 4. Type change system-parameters offer-options and p ress En te r. 5. If the Activate Offer field is n , set it to y and press Ta b. A warning messag e lets you know whether you need to save translations and reb oot to make the c hang e p ermanent. 6. Press En t e r to effec t the c hang es or Canc el if there were no c hang es. 7. Contac t the req uester when d one.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-79 Add Pooled Modem 5 Add Pooled Modem Modem Pooling supports 2 kinds of conversion resources: integrated and combined. The integrated type requires a TN758 Pooled Modem circuit pack for each 2 conversion resources provided. The combined type requires a port on a TN754B Digital Line circuit pack and a port on either an 8-port TN742, TN769; a 16-port TN746B; or a 24-port TN793/B, TN2793/B Analog Line circuit pack for each conversion resource provided. The pooled modem requires a Lucent WP90110 L7 power supply. Although an integrated conversion resource can use either the L5 or L7, the combined only works with an L7. !CAUTION: The L5 and L7 p ower supp lies look id entic al. Chec k the list numb er on the power supply before installing. 1. Determine the p ort assig nment of the c irc uit p ac ks to b e ad d ed (if req uired ). 2. Install the ap p rop riate c irc uit pac ks in assigned c arrier slot (if req uired ). 3. For Paradyne 3800 Series mod ems: a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1 and p ress En te r. b. Type ATY0S10=100S78=2M0E0\N1&W and p ress En t e r. 4.For other typ es of mod ems, refer to the vend or’s d oc umentation. Settings for Modem Connected to Data Module 1. Type add data-module next and press En t e r. 2. Type pdm in the Type field . 3. Type x in the Port field. 4. Type dte in the Connected to field and press En te r. 5. Type add station next and press En t e r. 6. Type 2500 in the Type field. 7. Type x in the Port field. 8. Type n in the Tests field and p ress En te r. 9. Type add modem-pool next and p ress En te r. 10. Typ e combined in the Group Type field.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-80 Add External Modem to EPN 5 11. Typ e 5 in the Hold Time (min) field . 12. Typ e two-way in the Direction field . 13. Typ e 9600 in the Speed field. 14. Typ e Full in the Duplex field . 15. Typ e async in the Synchronization field . 16. Typ e the p ort p air assig nments in the Analog and Digital fields and p ress En t e r. Settings for Modem Connected to the Data Terminal Equipment (DTE) 1. Type add station next and press En t e r. 2. Type 2500 in the Type field. 3. Typ e the p ort assig nment in the Port field and p ress En t e r. Add External Modem to EPN U.S. Robotics Model USR 33.6 EXT External Modem Figure 5-33. Connect External Modem to EPN Figure Notes: 1. U.S. Rob otic s External Mod em 2. RS-232 Cable3. Exp ansion Port Network cydfepnm KLC 100397 TERM INAL 1 2 3
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-81 Add External Modem to PPN 5 1. Connec t an RS-232 c ab le to the modem. See Fig ure 5-33. NOTE: In the following step s, a PC with Wind ows 95 or Wind ows NT 4.0 may b e sub stituted for the d umb terminal. Use the Hyp erterminal (terminal emulation) ap p lic ation. 2. Connec t the op p osite end of the RS-232 c ab le to a d umb terminal. 3. Set the d umb terminal to full d up lex mod e. 4. Type AT&N6 to set the baud rate to 9600. NOTE: The mod em c onnec ts at 9600 b aud b ut throug hp ut is at 1200 b aud . 5. Type AT & W 0 to save the setting into non-volatile RAM. 6. Set Switc h 5 to the OFF (up ) p osition to disab le auto answer. 7. Disc onnec t the RS-232 c ab le from the terminal and c onnec t it to the TERMINAL c onnec tor on the rear of the system c ab inet. Add External Modem to PPN U.S. Robotics Model USR 33.6 EXT External Modem Figure 5-34. Connect External Modem to PPN Figure Notes: 1. U.S. Rob otic s External Mod em 2. RS-232 Cable3 . Pro c e s s o r Po r t N e t w o rk cydfepnm KLC 100397 TERM INAL 1 2 3
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-82 Add External Modem to TN1648B 5 1. Connec t an RS-232 c ab le to the modem. See Fig ure 5-34. NOTE: In the following step s, a PC with Wind ows 95 or Wind ows NT 4.0 may b e sub stituted for the d umb terminal. Use the Hyp erterminal (terminal emulation) ap p lic ation. 2. Connec t the op p osite end of the RS-232 c ab le to a d umb terminal. 3. Set the d umb terminal to full d up lex mod e. 4. Type AT&N6 to set the baud rate to 9600. NOTE: The mod em c onnec ts at 9600 b aud b ut throug hp ut is at 1200 b aud . 5. Type AT & W 0 to save the setting into non-volatile RAM. 6. Set Switc h 5 to the OFF (up ) p osition to disab le auto answer. 7. Disc onnec t the RS-232 c ab le from the terminal and c onnec t it to the TERMINAL c onnec tor on the rear of the system c ab inet. Add External Modem to TN1648B Use a type approved external modem. Unpack and Inspect 1. Verify the eq uipment rec eived . See Fig ure 5-35. Ac tual eq uip ment may vary in ap p earanc e and may ship in sep arate p ac kag es. 2. See Tab le 5-21 for a list of p art c omc od es.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-83 Add External Modem to TN1648B 5 Figure 5-35. External Modem Pass-Thru Kit Equipment Figure Notes 1. Pass-thru Tool 2. Mac hine Sc rew 3. Cable Tie4. Panel Ad ap ter Brac ket 5. Cab le Assemb ly 6. Cab le Tie Mount Table 5-21. Parts List Quantity Description Comcode 1 External mod em p ass-thru kit Kit inc lud es: p ass-thru tool, c ab le ties, p anel ad ap ter brac ket, mac hine sc rews, and c ab le tie mounts.848239596 1 Cab le Assemb ly H600-497 indakit2 EWS 091498 123 4 6 5
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-84 Add External Modem to TN1648B 5 Cabinet Preparation 1. Open the front d oor. NOTE: Ad ministration may b e req uired b efore removing the c irc uit p ac k in the following step . 2. Determine whic h slot will c ontain the new c irc uit p ac k. Remove the c irc uit p ac k or the app aratus b lank from this slot. 3. Install the new c irc uit p ac k. 4. From the front, remove the fan c over. See Fig ure 5-36 . Figure 5-36. Remove the Fan Cover lcda3fop EWS 110398 ENTER /YES ENTER /YES NEXT /NO NEXT / NO BACK BACK AUDIX AUDIXBOOT/ SHUTDOWN BOOT/ SHUTDOWN ALARMS ALARMS EMERTR EMERTR
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-85 Add External Modem to TN1648B 5 Install the Pass-thru Kit 1. Open the rear d oor. 2. Attac h the p anel ad ap ter b rac ket. See Fig ure 5-37 . 3. Insert the c ab le assemb ly. See Fi g u re 5 - 3 8 . Figure 5-37. Attach the Panel Adapter Bracket prda0002 EWS 090498
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-86 Add External Modem to TN1648B 5 Figure 5-38. Attach the Cable Assembly to the Bracket 4. Connec t the external mod em c ab le to the c ab le assemb ly. 5. Attac h the RJ45 (telep hone p lug) to the p ass-thru tool using a tie wrap . See Fi g u re 5 - 3 9 . If you are using only one RJ45, bund le the other one and tie wrap it near the b od y of the c ab le assemb ly. prda0003 EWS 090498