Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-5 Access the System 3 Connecting a PC You c an c onnec t your PC or lap top to the DEFINITY ECS R8si/R8c si/R8r either d irec tly (50 ft [ 15 m] or less) or remotely throug h a d ata mod ule or a mod em. Connecting directly to the DEFINITY ECS You c an c onnec t d irec tly from the PC if it is 50 ft (15 m) or less from the DEFINITY ECS. 1. Connec t the eq uip ment as shown in Fi g u re 3 - 3 . See Tab le 3-2 for the c onnec tions b y p latform. !CAUTION: For a DC-p owered system, install an EIA 116A Isolator (c omc od e 106005242) in series b etween the c ab le and the TERM, DOT, or Terminal Ac tive c onnec tor. Figure 3-3. A typical direct connection Figure Notes 1 . D EFI N I TY EC S ( PPN o n R8 r ) 2. 50-ft (15-m) M25A c ab le (RS-232)3. 9-to-25 pin ad ap ter if need ed 4. Comp uter with DSA or DNA Table 3-2. PC connections by platform Reliability R8r R8si R8csi Standard Terminal Active TERM TERM Hig h/Critic al—DOT— cydfdr23 LJK 021800 2 31 4
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-6 Access the System 3 Connecting remotely to the DEFINITY ECS To c onnec t remotely to the system, you need one of the following p iec es of hard ware: nConnec ting throug h a data mod ule nConnec ting b y analog mod em to INADS p ort Connecting through a data module If more than 50 ft (15 m) from the DEFINITY ECS, you c an c onnec t the PC throug h a data module. 1. Connec t the eq uip ment as shown in Fi g u re 3 - 4 . Figure 3-4. A typical remote connection using an 8400B (top) or 7400B (bottom) data module Figure Notes 1. DEFINITY ECS 2. Dig ital line c irc uit p ac k 3. B25A 25-p air c able 4. Main d istrib ution frame (MDF) 5. 103A or Luc ent mod ular wall jac k 6. 400B2 ad apter 7. D6AP p ower c ord (8400B+ only)8. Data module power supply 9. 7-ft (2-m) D8W mod ular cord 10. Data mod ule (8400B+ [ top ] or 7400B+ [ b ottom] ) 11. 50-ft (15-m) M25A c able (RS-232) 12. Comp uter with DSA or DNA cydfdr08 KLC021500 3 3 4 4 8 5 5 1 29 1 26 7 8 9 10 10 11 11 12 12
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-7 Access the System 3 NOTE: With a 7400A or 7400B+ data mod ule, use a 4-wire d ig ital line c irc uit p ac k. With the 8400B+ d ata mod ule, use a 2-wire d igital line c irc uit p ac k. In p lac e of a 7400B+ d ata mod ule, you c an use a 7400A d ata mod ule. If you do, set the 7400A to DCE Mod e. 2. Wire the d ig ital line c irc uit p ac k to the wall jac k as follows: nFor a 7400B+ , wire to the sec ond and third pair of the wall jac k. nFor an 8400B+ , wire to the first p air of the wall jac k. Setting the Data Module to DCE Mode 1. Cyc le the p ower to the d ata mod ule. The unit p erforms a self test and displays its operating mode. 2. Observe the d isp lay. a. If the d isp lay reads DCE mod e, p roc eed to the next sec tion. b . If the d isp lay reads DTE mod e, c omp lete the following step s: 1. Remove the p ower c ord from the unit. 2. Remove the c over from the top rear of the unit. 3. Remove the mod e selec t c irc uit b oard and turn it around . 4. Rep lac e the c over. 5. Connect the power c ord.The unit performs a self test. NOTE: The p ower LED must b e stead y on. If the p ower LED is b linking, the d ata mod ule is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac ks, and d ata mod ule. Adding a Data Module to the Switch 1. Add the data module to the switch by entering add data-module number or add data-module next . 2. In the Type: field , typ e pdm and press En te r. 3. In the Port: field , typ e the loc ation of the d ig ital line c irc uit p ac k connec ted to the data module (for example 01A1503). 4. If system ac c ess p orts and hunt g roup s have not b een set up , set them up . Refer to DEFINITY ECS Release 8 Ad ministrator’s Guid e.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-8 Access the System 3 Testing Hardware Connections In the following tab le, find your d ata mod ule and follow the instruc tions for testing and troub leshooting it. . Setting the Data Module Operating Mode 1. Connec t an RS-232 c ab le from the DSA/DNA c omp uter to the d ata mod ule. If you are using an 8400B+ , c onnec t the DSA/DNA c omp uter to the data module using the supplied adapter cable. 2. Using a terminal emulator, c onnec t to the serial p ort to whic h the d ata mod ule is c onnec ted , and set the emulation to vt100 mod e. 3. Type AT at the p romp t and p ress En t e r.The d ata mod ule should return an OK. If it d oes not, b e sure that a stand ard RS-232 or EIA-232 c ab le is connec ted (not a null modem c able). 4. Set the operating mode as described in the following table. 5. Disc onnec t the terminal from the d ata mod ule and rec onnec t the d ata mod ule to the system c ab ling . Ty p e o f Data Module How to Test and Troubleshoot 8400B+ The red LED should b e stead y on. If the red and g reen LEDs are b linking , the unit is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and the 8400B+ . 7400B+ The Power and TR LEDs should b e stead y on. If the Power and Data LEDs are b linking , the unit is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and the 7400B+ . 7400A Set the 7400A to DCE mod e. The Power LED must b e stead y on. The DTR, DSR, DCD, RTS, and CTS setting s must b e hig hlig hted in the d isp lay. If the Power LED is b linking , the d ata mod ule is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and 7400A. Ty p e o f Data Module How to set the operating mode 8400B+ Typ e AT&F and press En t e r. Typ e ATS24=1 and press En te r. Type AT&WØ and press En t e r to save the operating mode into non-volatile RAM. 7400A 7400B+Ty p e AT&F and press En t e r. Typ e AT&WØ and press En te r to save the op erating mod e into non-volatile RAM.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-9 Access the System 3 Setting the 7400B+ Options 1. Set the DIP switc hes for the 7400B+ using Tab le 3-3. The DIP switc hes are loc ated insid e the unit. To ac c ess them a. Remove the p ower c ord from the unit. b . Remove the c over from the top rear of the unit. c . Set the d ip switc hes. d . Rep lac e the c over. e. Connect the power c ord.The unit performs a self test. 2. If any switc hes were set in step 1, c yc le the p ower to the d ata mod ule so that the firmware c an read the new switc h setting s. Connecting by analog modem to INADS port You c an c onnec t a PC to the DEFINITY ECS throug h a mod em. Table 3-3. DIP Switch Settings (7400B+) Option DIP Switch Setting No Telep hone Connec ted 1 On Data Metering 5 Off Sup p ress Touc h-tone/Dial Tone 6 Off Sp eakerp hone Disab le/Enab le 7 Off Busyout on Loc al Loop 8 Off Unused DIP Switc hes 2, 3, and 4 Off
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-10 Access the System 3 1. Connec t the eq uip ment as shown in Fi g u re 3 - 5. Figure 3-5. A typical remote connection through a modem to access a remote DEFINITY ECS Follow these step s to c onnec t to the DEFINITY ECS through a mod em. 1. Connec t the c omp uter to the mod em. 2. Connec t an analog telephone line to the left most analog -line p ort on the mod em. 3.Make sure that the mod em’s DIP switc hes are set as shown in Ta b l e 3 - 4 . Figure Notes 1. Comp uter with DSA or DNA 2. 50-ft (15-m) M25A c ab le (RS-232— 9-25 p in ad ap ter if need ed ) 3. Analog mod em 4. 7-ft (2-m) D2W mod ular c ord 5. 103A or Luc ent mod ular wall jac k 6. Main d istrib ution frame (MDF)7. Analog line circuit pack 8. Analog trunk c irc uit p ac k Pac ket d ata line (R8r) Data line (R8r) 9. DEFINITY ECS 10. B25A c ab le 11. Analog line cydr0031 LJK 021800 1 2 3 11 4 5 78 9 1010 6
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-11 Access the System 3 4. Plug the mod em into an AC p ower outlet. 5. Turn on the modem. 6. Set the following p ort setting s: Table 3-4. U.S. Robotics Modem Dip Switch Settings Dip Switch Setting Description 1UP DOWNData Terminal Read y normal Data Terminal Ready override 2UP DOWNVe r b a l r e s u lt c o d e s Numeric result codes 3UP DOWNSuppress result codes Display result codes 4UP DOWNEc ho offline c ommand s No echo, offline commands 5UP DOWNAuto answer on first ring or higher if specified in NVRAM Auto answer off 6UP DOWNCarrier d etec t normal Carrier detect override 7UP DOWNLoad NVRAM d efaults Load factory defaults 8UP DOWNDumb mod e Smart mode Baud rate 9600 Data b its 8 Pa r it y N o n e Stop b its 1 Flow c ontrol hard ware
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-12 Activate the System 3 Activate the System Instruc tions are p rovid ed to ac tivate Release 8 and later systems. To ac tivate a G3V4 and earlier system, refer to DEFINITY Communic ations System Generic 3 Installation and Test. NOTE: To p revent unnec essary troub le tic kets, d o not enab le the system alarms (Alarm Orig ination feature) until all installation and ad ministration p roc ed ures are c omp leted . !CAUTION: It may be nec essary to reseat c irc uit p ac ks. To prevent d amag e from static elec tric ity, always wear an Elec tromag netic Comp atib ility (EMC) wrist strap (c omc od e 900698226) when hand ling all system c omp onents. Install Translation Card (Release 8si in MCC Cabinet) 1. Insert the translation c ard into the TN794 Network Control c irc uit p ac k in the direction indicated by the arrow on the label. Install Removable Media (Release 8r in MCC Cabinet) 2. Insert the formatted removab le med ia, lab el fac ing left, into the op tic al drive (see Fi g u re 3 - 6 ).
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-13 Activate the System 3 Figure 3-6. TN2211 Optical Drive NOTE: Make sure the formatted removab le med ia is not write-p rotec ted (see Fig ure 3-7 ) b efore plac ing it into the op tic al d rive. Figure 3-7. Make sure the disk is not write protected Figure Notes 1. Not write protec ted 2. Write p rotec ted Red Green Yellow fpdf2211 KLC 010600TN2211 OPTICAL DRIVE h1dfdsk KLC 112499 12
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-14 Activate the System 3 Power Up the System AC-Powered System 1. Set the c irc uit breakers on the AC p ower p anel to ON. If the system is hig h or c ritic al reliab ility, p ower-up the EPN c ab inet first, then the PPN c ab inet. Always p ower up the PPN c ab inet last. 2. Set the c ab inet c irc uit breakers to ON. This starts the system initialization and test. All red LEDs on the c irc uit pac ks go on and then off. 3. Skip to ‘‘ Verify Messag es on Terminal’’. DC-Powered System 1. At the DC Battery Cab inet (if installed ), set the c irc uit breaker to ON. 2. At the DC Power Cab inet, set the c irc uit b reaker(s) on the rec tifiers ON. This starts the system initialization and test. Some red LEDs may b e on b ut are turned off b y other p roc ed ures in this c hap ter. 3. If the system is hig h or c ritic al reliab ility, p ower-up the EPN c ab inet first, then the PPN c ab inet. Always p ower up the PPN c abinet last. Verify Messages on Terminal 1. After several minutes, verify all tests p ass. Sc reen 3-1 d isp lays the sc reen c ontents of a typ ic al Release 8r system with 3 memory c irc uit p ac ks. The Release 8si system sc reen is similar. NOTE: If any of the terminal messag es ind ic ate a test has failed or if the messag e “spe down mode ” is d isp layed , refer to D EFINITY En terp ris e Communic ations Server Release 8 Maintenanc e for R8r, or DEFINITY Enterprise Communic ations Server Release 8 Maintenanc e for R8si, to c lear the troub le.