Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Cable Ductwork 
    C-15  
    C
    Figure C-10. Installation of I/O Cable Rack Coupling to Rear of Cabinet 
    Install I/O Cable Rack Riser
    Refer to Fi g u re  C - 1 1 and assemb le the d uc twork:
    1. Attac h ang le b rac ket (g roup  9) to I/O troug h using  thread -forming  sc rews.
    2. Attac h c ross-aisle b rac ket to ang le brac ket using  thread -forming  sc rews. 
    Attac h the ang le b rac ket to the 6-hole fac e of the c ross-aisle b rac ket using  
    three thread-forming  sc rews throug h the b ottom holes.
    3. Attac h I/O c oup ling  troug h (g roup  8) to c ross-aisle b rac ket using  
    thread -forming sc rews.
    4. Attac h c ab le rac k to c oup ling  troug h using  loc ally-p rovid ed  c oup ling  
    p lates and  3/8-18 x 1/2 inc h hex b olts and  nuts.
    5. Attac h other end  of c able rac k to wall using loc ally p rovid ed hard ware 
    suitab le to typ e of wall. Figure Notes
    1. Cross-Aisle Brac ket
    2. Coup ling  Plate
    3. Cable Rac k
    4. I/O Coup ling  Troug h5. I/O Troug h
    6. Use Only When Req uired
    7. To Wall
    duct6 KLC 071796 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Cable Ductwork 
    C-16  
    C
    Figure C-11. Installation of I/O Cable Rack Riser to End of Cabinet (Group 9)
    Install AC Power Duct
    Refer to Fi g u re  C - 1 2 and assemb le the d uc twork:
    1. Hang AC p ower d uc t (group  12 throug h 16 and  21) on b ac k of shield ed  
    d uc t and  anc hor in plac e using  one thread -forming  sc rew at eac h c abinet.
    2. If req uired , slid e utility outlet assemb ly (part of g roup 18) into the d uc t from 
    the end .
    3. Repeat steps 1 and 2 for each cabinet.
    4. Interc onnec t d uc ts with c oup lings using  four round-head  mac hine sc rews.
    5. Insert 4 wire hold ers into eac h d uc t sp ac ed  evenly along  d uc t.
    6. If equip p ed  with an AC outlet, snap two g roup  18 rac eway c overs into 
    p lac e onto the AC p ower d uc ts.
    7. If not eq uip p ed  with an AC outlet, snap  a g roup  17 rac eway c over into 
    p lac e onto the AC p ower d uc ts.
    8. If req uired , attac h g roup  19 (c omb ination end  c ap ) b y using  two round  
    head  mac hine sc rews.
    9. Assemb le the lad d er rac k as shown in Figure C-13 on page C-18
    . Figure Notes
    1. I/O Troug h
    2. Ang le Brac ket
    3. Coup ling  Plate
    4. Cable Rac k5. I/O Coup ling Troug h
    6. Cross-Aisle Brac ket
    7. Front of Cab inet
    duct7 KLC 071796 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Cable Ductwork 
    C-17  
    C
    Figure C-12. Install AC Power DuctFigure Notes
    1. Rac eway Cover
    2. Twist-Loc k Rec ep tac le
    3. Thread-Forming  Sc rew
    4. Comb ination Endc ap
    5. Cond uit Knoc kout
    6. I/O Power Duc t7. Rear of Shielded Duc t
    8. Coup ling
    9. Typ ical Utility Outlet Assembly
    10. Slid e in Direc tion Shown
    11. Wire Holders 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Cable Ductwork 
    C-18  
    C
    Figure C-13. Assembly of Ladder Rack
    duct9 KLC 071696 
    						
    							Connector and Cable Diagrams 
    D-1  
    D
    DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    D
    Connector and Cable Diagrams
    This c hapter p rovid es c onnec tor and  c ab le d iag rams for the DEFINITY 
    Enterp rise Communic ations Server.
    For c irc uit p ac k and  auxiliary eq uip ment c lassific ations, see the tab les at the end  
    of Chap ter 5, ‘‘
    Install and  Wire Telep hones and  Other Eq uip ment’’. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Connector and Cable Diagrams 
    D-2  
    D
    See Fig ure D-1 for Exp ansion Interfac e to Exp ansion Interfac e fib er interc onnec t.
    Figure D-1. Expansion Interface to Expansion Interface Fiber (Part 1)
    +5V
    +5V
    GRD
    XMT_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V 002
    102
    003
    103
    004
    104
    005
    105
    006
    106
    007
    107
    008
    108(P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 329823A/B(P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 329823A/B
    EIEI FS 1 -EI to EI fiber cable
    Fiber
    Fiber
    +5V
    +5V
    GRD
    XMT_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V002
    102
    003
    103
    004
    104
    005
    105
    006
    106
    007
    107
    008
    108 Front
    Fr o n tFr o n t
    Fr o n t Rear
    RearRear
    Rear Backplane
    BackplaneBackplane
    Backplane
    FrontFr o n t
    RearRear BackplaneBackplane
    +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V
    XMT_DAT
    RCV_DAT +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V002
    102
    003
    004
    104
    005
    105
    006
    106
    007
    008
    108
    103
    107 000
    100
    001
    002
    102
    003
    103
    004
    104
    005
    006
    106
    101
    105(J2) 1
    (J2) 26
    (J2) 2
    (J2) 3
    (J2) 28
    (J2) 4
    (J2) 29
    (J2) 5
    (J2) 30
    (J2) 6
    (J2) 7
    (J2) 32
    (J2) 27
    (J2) 31 (J1) 1
    (J1) 26
    (J1) 2
    (J1) 3
    (J1) 28
    (J1) 4
    (J1) 29
    (J1) 5
    (J1) 30
    (J1) 6
    (J1) 7
    (J1) 32
    (J1) 27
    (J1) 31
    SNIEI FS 3 -SNI to EI metallic cable H600-278
    +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V
    XMT_DAT
    RCV_DAT
    +5V
    +5V
    GRD
    XMT_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V 002
    102
    003
    103
    004
    104
    005
    105
    006
    106
    007
    107
    008
    108(P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 329823A/B(P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 329823A/B
    SNIEI FS 2 -SNI to EI fiber cable+5V
    +5V
    GRD
    XMT_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V000
    100
    001
    101
    002
    102
    003
    103
    004
    104
    005
    105
    006
    106
    r975bb1a MMR 061396 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Connector and Cable Diagrams 
    D-3  
    D
    Figure D-2. Expansion Interface to Expansion Interface Fiber (Part 2)
    Fron tFr on t
    RearRear BackplaneBackplane
    Fron tFr on t
    RearRear BackplaneBackplane
    +5V
    +5V
    GRD
    XMT_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V(P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 32
    9823A/B
    (P1) 1
    (P1) 26
    (P1) 2
    (P1) 27
    (P1) 3
    (P1) 28
    (P1) 4
    (P1) 29
    (P1) 5
    (P1) 30
    (P1) 6
    (P1) 31
    (P1) 7
    (P1) 32
    9823A/B
    SNISNI FS 5 -SNI to SNI fiber cable
    Fiber
    +5V
    +5V
    GRD
    XMY_DAT
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RCV_DAT
    +5V
    +5V000
    100
    001
    101
    002
    102
    003
    103
    004
    104
    005
    105
    006
    106000
    100
    001
    101
    002
    102
    003
    103
    004
    104
    005
    105
    006
    106
    +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V
    XMT_DAT
    RCV_DAT +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V002
    102
    003
    004
    104
    005
    105
    006
    106
    007
    008
    108
    103
    107 002
    102
    003
    004
    104
    005
    105
    006
    106
    007
    008
    108
    103
    107(J2) 1
    (J2) 26
    (J2) 2
    (J2) 3
    (J2) 28
    (J2) 4
    (J2) 29
    (J2) 5
    (J2) 30
    (J2) 6
    (J2) 7
    (J2) 32
    (J2) 27
    (J2) 31 (J1) 1
    (J1) 26
    (J1) 2
    (J1) 3
    (J1) 28
    (J1) 4
    (J1) 29
    (J1) 5
    (J1) 30
    (J1) 6
    (J1) 7
    (J1) 32
    (J1) 27
    (J1) 31
    EIEI FS 4 -EI to EI metallic cable H600-278
    +5V
    +5V
    GRD
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    +5V
    +5V
    XMT_DAT
    RCV_DAT
    r975bb1b MMR 061396 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Connector and Cable Diagrams 
    D-4  
    D
    Figure D-3. Sample Cross-Connects
    103A
    information outlet
    T (red)
    R (green)
    C1 (yellow)
    C2 (black)T
    R
    Modular
    cord
    C1
    C2
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    G1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50BLANK
    BLANK
    BLANK
    BLANK
    BLANK
    BLANK
    BLANK
    BLANK
    BLANK1
    2
    3
    4
    5
    6
    7
    8
    Pinouts
    TN553 (12 ports) TN726 (8 ports)
    25
    24
    23
    22
    21
    20
    19
    18
    17
    16
    15
    14
    13
    12
    11
    10
    9
    8
    7
    6
    5
    4
    3
    2
    1
    GRD
    GSP0/2
    LOA*
    LIA
    GSP1/3
    LOB*
    LIB
    GSP3*
    LOC*
    LIC
    RSS0*
    LOD*
    LID
    CPERXD
    PTD*
    RES FLT*
    CHG RT*
    PSSG
    +5E
    GRDE
    GRDE
    TA *
    GRDE
    GRDE
    +5EGRD
    GSP0*
    LOA
    LIA*
    GSP1*
    LOB
    LIB*
    GSP2*
    LOC
    LIC*
    RSS1*
    LOD
    LID*
    CPETXD
    BAT DISC*
    ON RES*
    ENVB*
    PSS
    +5E
    RCV DAT*
    GRDE
    TL*
    GRDE
    XMT DAT*
    +5E50
    49
    48
    47
    46
    45
    44
    43
    42
    41
    40
    39
    38
    37
    36
    35
    34
    33
    32
    31
    30
    29
    28
    27
    26
    TN1654 Amphenol
    pinouts
    1
    226
    27
    2
    327
    28
    Example cross connect
    Amphenol pinouts
    TN553
    TN762B
    123456789101112
    123456789101112
    110 blockPo r t 1 Por t 2
    (TN553)
    110 block(TN726B) Etc.
    (48)LOA
    (23)LOA*
    (22)LIA
    (47)LIA*
    (45)LOB
    (20)LOB*
    (19)LIB
    (44)LIB*
    (42)LOC
    (17)LOC*
    (16)LIC
    (41)LIC*
    (39)LOD
    (14)LOD*
    (13)LID
    (38)LID* (48)LOA
    (23)LOA*
    (22)LIA
    (47)LIA*
    (45)LOB
    (20)LOB*
    (19)LIB
    (44)LIB*
    (42)LOC
    (17)LOC*
    (16)LIC
    (41)LIC*
    (39)LOD
    (14)LOD*
    (13)LID
    (38)LID*
    TN1654 to TN1654
    direct cross connect
    r975bb2 MMR 061396 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Connector and Cable Diagrams 
    D-5  
    D
    Figure D-4. Sample Cable Pinouts
    FS 10H600-348 cable50-pin Amphenol
    connector TN165415-pin D-sub
    DS1 interface to a CSU
    Connector 01
    Connector 02
    Connector 03
    Connector 04 23
    48
    22
    47
    20
    45
    19
    44
    17
    42
    16
    41
    14
    39
    13
    38LOA*
    LOA
    LIA
    LIA*
    LOB*
    LOB
    LIB
    LIB*
    LOC*
    LOC
    LIC
    LIC*
    LOD*
    LOD
    LID
    LID*1
    9
    3
    11 LOA*
    LOA
    LIA
    LIA*
    1
    9
    3
    11 LOB*
    LOB
    LIB
    LIB*
    1
    9
    3
    11 LOC*
    LOC
    LIC
    LIC*
    1
    9
    3
    11 LOD*
    LOD
    LID
    LID*
    FS 12Amphenol connector
    to TN1654
    2
    27
    3
    28
    5
    30
    6
    31
    23
    48
    22
    47
    20
    45
    19
    44
    17
    42
    16
    41
    14
    39
    13
    38GRDE
    XMT_DAT*
    GRD
    GRD
    GRD
    GRD
    GRD
    RCV_DAT*
    LOA*
    LOA
    LIA
    LIA*
    LOB*
    LOB
    LIB
    LIB*
    LOC*
    LOC
    LIC
    LIC*
    LOD*
    LOD
    LID
    LID*
    FS 11H600-347 cable
    (packet gateway interface cable)
    Amphenol
    connector
    to TN577Amphenol
    connector
    to TN577 25-pin D-sub
    connectors25-pin D-subconnectors
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25TC0
    DCD0
    RC0
    CTS0
    RD0
    SG0
    TD0
    DTR0
    TT0
    LL0
    RTS0
    TC1
    DCD1
    RC1
    CTS1
    RD1
    SG1
    TD1
    DTR1
    TT1
    LL1
    RTS1Connector 1
    15
    8
    17
    5
    3
    7
    2
    20
    24
    18
    4
    No connection
    Connector 2
    15
    8
    17
    5
    3
    7
    2
    20
    24
    18
    4
    No connection
    No connectionTC2
    DCD2
    RC2
    CTS2
    RD2
    SG2
    TD2
    DTR2
    TT2
    LL2
    RTS2
    TC3
    DCD3
    RC3
    CTS3
    RD3
    SG3
    TD3
    DTR3
    TT3
    LL3
    RTS3Connector 3
    15
    8
    17
    5
    3
    7
    2
    20
    24
    18
    4
    No connection
    Connector 4
    15
    8
    17
    5
    3
    7
    2
    20
    24
    18
    4
    No connection
    No connection
    r975bb3 MMR 051096
    Amphenol connector
    to TN570 or TN573
    2
    31
    3
    28
    5
    30
    6
    27
    23
    48
    22
    47
    20
    45
    19
    44
    17
    42
    16
    41
    14
    39
    13
    38 GRDE
    RCV_DAT*
    GRDE
    GRDE
    GRDE
    GRDE
    GRDE
    XMT_DAT*
    LOA*
    LOA
    LIA
    LIA*
    LOB*
    LOB
    LIB
    LIB*
    LOC*
    LOC
    LIC
    LIC*
    LOD*
    LOD
    LID
    LID*
    Pass thru to Amphenol
    connector to H600-348
    or to cross connect 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Connector and Cable Diagrams 
    D-6  
    D
    Figure D-5. Sample Pinouts
    FS 13600-307 cable
    50-pin Amphenol
    connector to
    TN767,TN722,TN464
    15-pin D-sub
    to a CSU
    2
    3
    22
    47
    23
    48
    24
    49GRD
    GRD
    LI
    LI*
    LO*
    L0
    LOOP1
    LOOP2
    3
    11
    1
    9
    5
    6 LI
    LI*
    LO*
    L0
    LOOP1
    LOOP2
    FS 14846448652
    Amphenol
    connection
    to TN1654
    1
    26
    2
    27
    3
    28
    4
    29
    5
    30
    6
    31
    7
    32
    23
    48
    22
    47
    20
    45
    19
    44
    17
    42
    16
    41
    14
    39
    13
    38+5
    +5
    GRD
    TX
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RX
    +5
    +5
    LOA*
    LOA
    LIA
    LIA*
    LOB*
    LOB
    LIB
    LIB*
    LOC*
    LOC
    LIC
    LIC*
    LOD*
    LOD
    LID
    LID*
    FS 15Clock
    (STRATUM 3
    clock interface)
    PPN control carrier
    25
    24
    23
    22
    21
    20
    19
    18
    17
    16
    15
    14
    13
    12
    11
    10
    09
    08
    07
    06
    05
    04
    03
    02
    0150
    49
    48
    47
    46
    45
    44
    43
    42
    41
    40
    39
    38
    37
    36
    35
    34
    33
    32
    31
    30
    29
    28
    27
    26
    ALRM5A
    EXTSYN0R
    EXTSYN1T
    ALRM1A
    ALRM4A
    ALRM3A
    ALRM2A
    ALRM0AALRM5B
    EXTSYN0T
    EXTSYN1R
    ALRM1B
    ALRM4B
    ALRM3B
    ALRM2B
    ALRM0B
    FS 16TERMINAL
    PPN & EPN
    terminal connections
    Pin
    numberLead
    designation
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24TD
    RD
    RTS
    CTS
    DSR
    SGRD
    CD
    DTR
    r975bb4 MMR 061396
    Amphenol connection
    to fiber transceiver
    1
    26
    2
    27
    3
    28
    4
    29
    5
    30
    6
    31
    7
    32
    23
    48
    22
    47
    20
    45
    19
    44
    17
    42
    16
    41
    14
    39
    13
    38 +5
    +5
    GRD
    TX
    GRD
    GRD
    TA *
    TL*
    GRD
    GRD
    GRD
    RX
    +5
    +5
    LOA*
    LOA
    LIA
    LIA*
    LOB*
    LOB
    LIB
    LIB*
    LOC*
    LOC
    LIC
    LIC*
    LOD*
    LOD
    LID
    LID*
    Pass thru to
    Amphenol
    connection to
    H600-348 or to
    cross connect 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual