Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-97 Add ISDN — PRI 5 Add ISDN — PRI North American 1. Use a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit p ac k for a sig naling link and up to 23 ISDN — PRI Trunk Group members. 2. Install a TN768, TN780, or TN2182B Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1 c irc uit p ac k. If a TN464 is used, packet bus support has not been added, and more PRI signaling groups are required (more than 4 for an SCC or 8 for an MCC), then see ‘‘ Add Packet Bus Support’’ on page 5-99 for installing additional circuit packs for packet bus support. As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock (installed in the PPN) can interface external Stratum 3 synchronization for DS1. International 1. Install a TN464C (or later) DS1/E1 c irc uit p ac k for the assig nment of the 2 sig naling c hannels and up to 30 ISDN — PRI Trunk Group memb ers. Eac h E1 sp an p rovid es 32 p orts. 2. Install a TN780, TN2182B, or TN419B Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1/E1 c irc uit p ac k. If packet bus support has not been added and more than 8 PRI signaling groups are required, then see ‘‘ Add Packet Bus Support’’ on page 5-99 for installing additional circuit packs for packet bus support. As an option to the TN2182B or TN419B Tone-Clock, a TN780 Tone-Clock (installed in the PPN) can interface external Stratum 3 synchronization for DS1. Service Interruption 1. If packet bus support for G3si must be added and TN750s must be installed as p art of that supp ort, then ad d ing ISDN — PRI req uires a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the ad d ition will be c arried out. See ‘‘ Ad d Packet Bus Sup p ort’’ on page 5-99 for further information. Add Packet Bus Support 1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus Support’’ on page 5-99 and p erform the step s.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-98 Add ISDN — PRI 5 Add Circuit Packs 1. Determine port assig nment of c irc uit p ac ks to be ad d ed . 2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot. 3. Install a TN748B (or later) (or the international TN420B/C) Tone Detec tor circuit pack if required. Install Cables 1. Install c ab les from c ab inet to MDF as req uired . Enter Added Translations 1.Ad minister the forms listed und er “ Integ rated Servic es Dig ital Network — Primary Rate Interfac e” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using D EFI N I TY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. Up d ate b ac kup c ard s, if nec essary.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-99 Add Packet Bus Support 5 Add Packet Bus Support NOTE: This p roc ed ure is valid for G3si systems only. It d oes not ap p ly to G3r systems. Standard Reliability Service Interruption 1. If packet bus support for G3si must be added and TN750s must be installed as part of that support, then adding Packet Bas Support requires a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the ad d ition will be c arried out. Disable Alarm Origination 1. Type change system-parameters maintenance and press En t e r. 2. Set the Alarm Origination Activated field to n . !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. For some releases of software, disab le Cleared Alarm Notification and Restart Notification b efore sub mitting the form. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard . 3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. If ad ministered rec orded announc ements are listed , typ e list configuration software-version and p ress En t e r. To save the announc ements, typ e save announcements and p ress En t e r. Power Down Cabinet 1. At the PPN, set the main c irc uit b reaker to OFF. 2. At an EPN, set the main c irc uit b reaker to OFF.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-100 Add Packet Bus Support 5 Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-23. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s. Reb ooting takes ab out 10 minutes. 4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Test the Packet Bus and C-LAN Circuit Pack 1. Type test packet port-network 1 and p ress En t e r. For more d etail ab out these tests, refer to the test p kt c ommand sec tion in the maintenanc e b ook. Resolve Alarms 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. Save Translations 1. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 2. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e restore announcements and press En t e r. 3. Up d ate b ac kup c ard s, if nec essary. Table 5-23. Circuit Pack Locations for Packet Bus in R8 PPN Circuit Pack Carrier Quantity Slot TN570 Control Carrier A 1 or 2 1 1. Quantity of this pac k should eq ual the numb er of EPNs. EXPN INTFC/1 and /2 TN771C Control Carrier A 1 2 2. Op tional for d igital trunk testing . Any Availab le Port Slot
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-101 Add Packet Bus Support 5 Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘ Where to Call for Tec hnic al Sup p ort’’ on page -xvii for telep hone numb ers. NOTE: As p art of the system reg istration p roc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination. 2. When ad ministration is c omp leted , log in as craft at the Login: prompt. High or Critical Reliability Service Interruption If no TN570 Expansion Interface circuit packs need to be installed for PktBus support, skip to and perform only the ‘‘ Install Circuit Packs’’ section. This procedure does not interrupt service in this case. init login administration: 1. Log in as init . 2. Type change system-parameters customer-options and press En te r to verify that the c ustomer op tions are p roperly set. 3. Go to sc reen 6, QSIG Op tional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protoc ol b or d on an ISDN-PRI trunk g roup b efore the up g rad e. 4. Type change system-parameters offer-options and p ress En te r. 5. If the Activate Offer field is n , set it to y and press Ta b. A warning messag e lets you know whether you need to save translations and reb oot to make the c hang e p ermanent. 6. Press En t e r to effec t the c hang es or Canc el if there were no c hang es. 7. Contac t the req uester when d one.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-102 Add Packet Bus Support 5 Disable Alarm Origination 1. Type change system-parameters maintenance and press En t e r. 2. Set the Alarm Origination Activated to OSS Numbers field to n . !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. For some releases of software, disab le Cleared Alarm Notification and Restart Notification b efore sub mitting the form. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. a. If administered rec ord ed announc ements are listed , typ e list configuration software-version long and p ress En t e r. b . To save the announc ements, typ e save announcements and press En te r. Power Down Cabinet (Standby Cabinet) 1. At the PPN, set the main c irc uit b reaker to OFF. 2. At an EPN, set the main c irc uit b reaker to OFF.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-103 Add Packet Bus Support 5 Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-24. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s. Reb ooting takes ab out 10 minutes. 4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Test the Packet Bus and C-LAN Circuit Pack 1. Type test packet port-network 1 long and p ress En t e r. For more d etail ab out these tests, refer to the “ test p kt c ommand ” sec tion in the maintenanc e b ook. Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using D EFI N I TY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. Table 5-24. Circuit Pack Locations for Packet Bus in PPN Circuit Pack Carrier Quantity Slot TN570 Control Carrier A 1 or 2 1 1. Quantity of this pac k should eq ual the numb er of EPNs.EXPN INTFC/1 and /2 Control Carrier B 1 or 2 EXPN INTFC/1 and /2 TN771C Control Carrier A 1 2 2. Required for c ritical-reliab ility EPNs and PPN. Op tional for d ig ital trunk testing in hig h-reliab ility PPN. Any Availab le Port Slot
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-104 Add Packet Bus Support 5 3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e restore announcements and press En t e r. 4. Up d ate b ac kup c ard s, if nec essary. Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘ Where to Call for Tec hnic al Sup p ort’’ on page -xvii for telep hone numb ers. NOTE: As p art of the system reg istration p roc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination. 2. When ad ministration is c omp leted , log in as craft at the Login: prompt. init login administration: 1. Log in as init . 2. Type change system-parameters customer-options and press En te r to verify that the c ustomer op tions are p roperly set. 3. Go to sc reen 6, QSIG Op tional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protoc ol b or d on an ISDN-PRI trunk g roup b efore the up g rad e. 4. Type change system-parameters offer-options and p ress En te r. 5. If the Activate Offer field is n , set it to y and press Ta b. A warning messag e lets you know whether you need to save translations and reb oot to make the c hang e p ermanent. 6. Press En t e r to effec t the c hang es or Canc el if there were no c hang es. 7. Contac t the req uester when d one.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-105 Add CallVisor ASAI 5 Add CallVisor ASAI Service Interruption 1. If ad d ing the pac ket b us sup p ort and TN570s must b e installed as part of that sup p ort, then ad d ing CallVisor ASAI req uires a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the ad d ition will take p lac e. See ‘‘ Add Packet Bus Support’’ on p ag e 5-99 for further information. Enter Added Translations 1. On the System-Parameters Customer-Op tions sc reen, disab le the Calling Party Numb er/Billing Numb er (CPN/BN) op tion, and enab le the CallVisor ASAI Interfac e op tion. 2. See DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e, for d etails on d isab ling and enab ling these op tions. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. Add Packet Bus Support 1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus Support’’ on page 5-99 and p erform the step s. Add Circuit Packs 1. Determine port assig nment of c irc uit p ac ks to be ad d ed . 2. Install the ap p rop riate c irc uit pac ks in assigned c ab inet slot (as req uired ). For example: 3 A 07 01 Cab inet (Port Network)Carrier Slot NumberPo r t Numb er
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-106 Add ISDN—BRI 5 The TN748B (or later) or TN744/C/D Call Classifier c irc uit p ac k is req uired . The TN744 is req uired for those c ustomers who d esire switc h c all c lassific ation. A vac ant p ort is req uired on a TN556/B ISDN—BRI circuit pack. Install Cables 1. Install c ab les from c ab inet to the MDF as req uired . Enter Added Translations 1. Ad minister the req uired translation d ata using the forms listed und er “ Ad junc t/Switc h Ap p lic ations Interfac e (ASAI)” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using D EFI N I TY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. Up d ate b ac kup translation c ard s, if required . Add ISDN—BRI Service Interruption If adding the packet bus support and TN570s must be installed as part of that support, adding ISDN—BRI requires a service interruption. Notify the customer in advance as to when the addition will be carried out. See ‘‘ Add Packet Bus Support’’ on page 5-99 for further information. Add Packet Bus Support 1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus Support’’ on page 5-99 and p erform the step s.