    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-97 Add ISDN — PRI 
    5
    Add ISDN — PRI
    North American
    1. Use a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit p ac k for a 
    sig naling  link and  up  to 23 ISDN — PRI Trunk Group members. 
    2. Install a TN768, TN780, or TN2182B Tone-Cloc k c irc uit p ac k to p rovid e 
    sync hronization for the DS1 c irc uit p ac k. 
    If a TN464 is used, packet bus support has not been added, and more PRI 
    signaling groups are required (more than 4 for an SCC or 8 for an MCC), then see 
    ‘‘
    Add Packet Bus Support’’ on page 5-99 for installing additional circuit packs for 
    packet bus support.
    As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock 
    (installed in the PPN) can interface external Stratum 3 synchronization for DS1.
    International
    1. Install a TN464C (or later) DS1/E1 c irc uit p ac k for the assig nment of the 2 
    sig naling  c hannels and  up  to 30 ISDN — PRI Trunk Group  memb ers. Eac h 
    E1 sp an p rovid es 32 p orts. 
    2. Install a TN780, TN2182B, or TN419B Tone-Cloc k c irc uit p ac k to p rovid e 
    sync hronization for the DS1/E1 c irc uit p ac k.
    If packet bus support has not been added and more than 8 PRI signaling groups 
    are required, then see ‘‘
    Add Packet Bus Support’’ on page 5-99 for installing 
    additional circuit packs for packet bus support.
    As an option to the TN2182B or TN419B Tone-Clock, a TN780 Tone-Clock 
    (installed in the PPN) can interface external Stratum 3 synchronization for DS1.
    Service Interruption
    1. If packet bus support for G3si must be added and TN750s must be 
    installed  as p art of that supp ort, then ad d ing  ISDN — PRI req uires a 
    servic e interrup tion. Notify the c ustomer in ad vanc e as to when the 
    ad d ition will be c arried  out. See ‘‘
    Ad d Packet Bus Sup p ort’’ on page 5-99 
    for further information.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 5-99 and  p erform the step s. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-98 Add ISDN — PRI 
    5
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot.
    3. Install a TN748B (or later) (or the international TN420B/C) Tone Detec tor 
    circuit pack if required.
    Install Cables
    1. Install c ab les from c ab inet to MDF as req uired .
    Enter Added Translations
    1.Ad minister the forms listed  und er “ Integ rated  Servic es Dig ital Network — 
    Primary Rate Interfac e”  in DEFINITY Enterp rise Communic ations Server 
    Release 8 Ad ministrator’s Guid e.
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. Up d ate b ac kup  c ard s, if nec essary. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-99 Add Packet Bus Support 
    5
    Add Packet Bus Support
    NOTE:
    This p roc ed ure is valid  for G3si systems only. It d oes not ap p ly to G3r 
    systems.
    Standard Reliability
    Service Interruption
    1. If packet bus support for G3si must be added and TN750s must be 
    installed as part of that support, then adding Packet Bas Support requires 
    a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the 
    ad d ition will be c arried  out.
    Disable Alarm Origination
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Set the Alarm Origination Activated
     field  to n
    .
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets. 
    3. For some releases of software, disab le Cleared Alarm Notification
     
    and  Restart Notification
     b efore sub mitting  the form.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard .
    3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r. If ad ministered  rec orded  
    announc ements are listed , typ e list configuration software-version 
    and  
    p ress 
    En t e r. To save the announc ements, typ e save announcements
     and 
    p ress 
    En t e r.
    Power Down Cabinet 
    1. At the PPN, set the main c irc uit b reaker to OFF.
    2. At an EPN, set the main c irc uit b reaker to OFF. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-100 Add Packet Bus Support 
    5
    Install Circuit Packs
    1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-23.
    Power Up System
    1. At the EPN, set the main c irc uit b reaker to ON.
    2. At the PPN, set the main c irc uit b reaker to ON.
    3. The system p erforms a level 4 reb oot, load ing  the system translations from 
    the translation c ard s. Reb ooting  takes ab out 10 minutes.
    4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL 
    switc h is set to AUTO. This restores the system to the normal mod e.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test packet port-network 1 
    and p ress En t e r. For more d etail ab out 
    these tests, refer to the test p kt c ommand sec tion in the maintenanc e 
    b ook. 
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8si. 
    Save Translations
    1. Type save translation
     and press En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    2. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e 
    restore announcements
     and press 
    En t e r.
    3. Up d ate b ac kup  c ard s, if nec essary.
    Table 5-23. Circuit Pack Locations for Packet Bus in R8 PPN
    Circuit Pack Carrier Quantity Slot
    TN570 Control Carrier A 1 or 2
    1
    1. Quantity of this pac k should  eq ual the numb er of EPNs.
    EXPN INTFC/1 and  /2
    TN771C Control Carrier A 1
    2
    2. Op tional for d igital trunk testing .
    Any Availab le Port Slot 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-101 Add Packet Bus Support 
    5
    Enable Customer Options and Alarm Origination 
    to INADS
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the reg ional Customer Software Ad ministration to c omp lete the step s 
    in the shad ed  b ox. See ‘‘
    Where to Call for Tec hnic al Sup p ort’’ on page -xvii 
    for telep hone numb ers.
    NOTE:
    As p art of the system reg istration p roc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination.
    2. When ad ministration is c omp leted , log  in as craft
     at the Login:
     prompt.
    High or Critical Reliability
    Service Interruption
    If no TN570 Expansion Interface circuit packs need to be installed for PktBus 
    support, skip to and perform only the ‘‘
    Install Circuit Packs’’ section. This 
    procedure does not interrupt service in this case.
    init login administration:
    1. Log in as init
    .
    2. Type change system-parameters customer-options
     and press 
    En te r 
    to verify that the c ustomer op tions are p roperly set.
    3. Go to sc reen 6, QSIG Op tional Features, and  set the Basic Call 
    Setup 
    field  to y
     if the customer was using Supplementary Services 
    Protoc ol b  or d  on an ISDN-PRI trunk g roup  b efore the up g rad e.
    4. Type change system-parameters offer-options
     and  p ress 
    En te r.
    5. If the Activate Offer
     field  is n
    , set it to y 
    and press 
    Ta b. A warning  
    messag e lets you know whether you need  to save translations and  
    reb oot to make the c hang e p ermanent.
    6. Press 
    En t e r to effec t the c hang es or Canc el if there were no c hang es.
    7. Contac t the req uester when d one. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-102 Add Packet Bus Support 
    5
    Disable Alarm Origination
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Set the Alarm Origination Activated to OSS Numbers 
    field to n
    .
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets. 
    3. For some releases of software, disab le Cleared Alarm Notification
     
    and  Restart Notification
     b efore sub mitting  the form.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r. 
    a. If administered  rec ord ed  announc ements are listed , typ e list 
    configuration software-version long
     and  p ress 
    En t e r. 
    b . To save the announc ements, typ e save announcements
     and press 
    En te r.
    Power Down Cabinet (Standby Cabinet)
    1. At the PPN, set the main c irc uit b reaker to OFF.
    2. At an EPN, set the main c irc uit b reaker to OFF. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-103 Add Packet Bus Support 
    5
    Install Circuit Packs
    1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-24.
    Power Up System
    1. At the EPN, set the main c irc uit b reaker to ON.
    2. At the PPN, set the main c irc uit b reaker to ON.
    3. The system p erforms a level 4 reb oot, load ing  the system translations from 
    the translation c ard s. Reb ooting  takes ab out 10 minutes.
    4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL 
    switc h is set to AUTO. This restores the system to the normal mod e.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test packet port-network 1 long 
    and p ress En t e r. For more d etail 
    ab out these tests, refer to the “ test p kt c ommand ”  sec tion in the 
    maintenanc e b ook. 
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    Table 5-24. Circuit Pack Locations for Packet Bus in PPN
    Circuit Pack Carrier Quantity Slot
    TN570 Control Carrier A 1 or 2
    1
    1. Quantity of this pac k should  eq ual the numb er of EPNs.EXPN INTFC/1 and  /2
    Control Carrier B 1 or 2 EXPN INTFC/1 and  /2
    TN771C Control Carrier A 1
    2
    2. Required  for c ritical-reliab ility EPNs and  PPN. Op tional for d ig ital trunk testing  in
    hig h-reliab ility PPN.
    Any Availab le Port Slot 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-104 Add Packet Bus Support 
    5
    3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e 
    restore announcements
     and press 
    En t e r.
    4. Up d ate b ac kup  c ard s, if nec essary.
    Enable Customer Options and Alarm Origination 
    to INADS
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the reg ional Customer Software Ad ministration to c omp lete the step s 
    in the shad ed  b ox. See ‘‘
    Where to Call for Tec hnic al Sup p ort’’ on page -xvii 
    for telep hone numb ers.
    NOTE:
    As p art of the system reg istration p roc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination.
    2. When ad ministration is c omp leted , log  in as craft
     at the Login:
     prompt.
    init login administration:
    1. Log in as init
    .
    2. Type change system-parameters customer-options
     and press 
    En te r 
    to verify that the c ustomer op tions are p roperly set.
    3. Go to sc reen 6, QSIG Op tional Features, and  set the Basic Call 
    Setup 
    field  to y
     if the customer was using Supplementary Services 
    Protoc ol b  or d  on an ISDN-PRI trunk g roup  b efore the up g rad e.
    4. Type change system-parameters offer-options
     and  p ress 
    En te r.
    5. If the Activate Offer
     field  is n
    , set it to y 
    and press 
    Ta b. A warning  
    messag e lets you know whether you need  to save translations and  
    reb oot to make the c hang e p ermanent.
    6. Press 
    En t e r to effec t the c hang es or Canc el if there were no c hang es.
    7. Contac t the req uester when d one. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-105 Add CallVisor ASAI 
    5
    Add CallVisor ASAI
    Service Interruption
    1. If ad d ing  the pac ket b us sup p ort and  TN570s must b e installed  as part of 
    that sup p ort, then ad d ing  CallVisor ASAI req uires a servic e interrup tion. 
    Notify the c ustomer in ad vanc e as to when the ad d ition will take p lac e. 
    See ‘‘
    Add Packet Bus Support’’ on p ag e 5-99 for further information.
    Enter Added Translations
    1. On the System-Parameters Customer-Op tions sc reen, disab le the Calling  
    Party Numb er/Billing  Numb er (CPN/BN) op tion, and  enab le the CallVisor 
    ASAI Interfac e op tion. 
    2. See DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e, for d etails on d isab ling  and  enab ling these op tions.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 5-99 and  p erform the step s.
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the ap p rop riate c irc uit pac ks in assigned  c ab inet slot (as req uired ). 
    For example:
    3 A 07 01
    Cab inet
    (Port Network)Carrier Slot 
    NumberPo r t  
    Numb er 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-106 Add ISDN—BRI 
    5
    The TN748B (or later) or TN744/C/D Call Classifier c irc uit p ac k is req uired . 
    The TN744 is req uired  for those c ustomers who d esire switc h c all 
    c lassific ation.
    A vac ant p ort is req uired on a TN556/B ISDN—BRI circuit pack.
    Install Cables
    1. Install c ab les from c ab inet to the MDF as req uired .
    Enter Added Translations
    1. Ad minister the req uired  translation d ata using the forms listed und er 
    “ Ad junc t/Switc h Ap p lic ations Interfac e (ASAI)”  in DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e.
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. Up d ate b ac kup  translation c ard s, if required .
    Add ISDN—BRI
    Service Interruption
    If adding the packet bus support and TN570s must be installed as part of that 
    support, adding ISDN—BRI requires a service interruption. Notify the customer in 
    advance as to when the addition will be carried out. See ‘‘
    Add Packet Bus 
    Support’’ on page 5-99 for further information.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support’’ on page 5-99 and  p erform the step s. 
    						