Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-35 Administer Fiber Links (Release 8r Only) 3 9. The DS1CONV Board Type : field is d isplay only and shows the type of DS1 Converter c irc uit p ac k in End p oint-1. The c irc uit p ac k type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the same. 10. In the Is one endpoint remoted via a DS1 Converter Complex? field , enter y to sp ec ify that a DS1 Converter c omp lex is used to remote 1 end p oint. If a y is entered , administer the A-PNC DS1 Converter Board Loc ation on Pag e 1. The A-PNC DS1 Converter Board Typ e d isp lays. Ad minister the A-PNC DS1 Converter (DS1CONV) Attrib utes on Pag e 2 of this form. 11. On Pag e 2 of the form, enter the DS1 Converter Fac ilities information. In the Facility Installed? field , enter y for all installed fac ilities (A, B, C, and D). 12. In the Bit Rate : field, enter 1.544 for T1 op eration or 2.048 for E1 op eration. NOTE: One b it rate ap p lies for all fac ilities within the same DS1 Converter complex. The Bit Rate: field displays only under Facility A. 13. Enter the id le c od e in the Idle Code MSB (1) . . . . LSB (8): field . The default value is 11101000 . It is rec ommend ed that the d efault value b e used unless it b ec omes ab solutely nec essary to c hang e it. The “ MSB” means Most Sig nific ant Bit, the “ LSB” means Least Sig nific ant Bit. 14. In the Line Coding: field , enter the line c od ing information. This information should matc h the line c od ing of the fac ility. For T1, examp le line c od ing is b8zs . For E1, examp le line c od ing is hdb3 . Sc roll to Pag e 3 and mod ify the field s as needed for the B-PNC. NOTE: If this d ata is not c orrec t, wid eb and errors (suc h as multimed ia c all hand ling ) may oc c ur. 15. For T1 sites, refer to ‘‘ T1 Installations Only’’. For E1 sites, refer to ‘‘E1 Installations Only’’. T1 Installations Only 1. The Framing Mode: field is d isp lay only and shows the hard ware setting . 2. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line Compensation: field s are d isp lay only and show the hard ware setting . 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED .
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-36 Administer Fiber Links (Release 8r Only) 3 E1 Installations Only 1. Type y or n in the CRC? field . The “ CRC” means Cyc lic Red und anc y Chec k. This is an error d etec tion alg orithm. 2. The Line Termination: field is d isp lay only. A 75 (75 Ohms) or 120 (120 Ohms) typ ic ally d isp lays. 3. In the Facility A Circuit ID: field , enter an op tional fac ility name that is uniq ue to eac h fac ility (up to 40 alp hanumeric c harac ters). Press En t e r. 4. A d isp lay similar to the following ap p ears after the fib er link ad ministration is c omp leted : RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED . All Installations 1. When the system reset is finished, type status port-network 2 and press En t e r. The Port Network Status sc reen ap p ears. Verify that PNC Ac tive is “ up ” and that the Servic e State is “ in.” 2. A Sp an LED, on the front of the DS1 Converter c irc uit p ac k, must b e on for eac h ac tive fac ility ad ministered . For examp le, if Fac ility A and Fac ility B are ad ministered , then the top 2 Sp an LEDs on the c irc uit p ac k must be on (yellow). The yellow LEDs are on only if no p rob lems were enc ountered d uring the ad ministration of hard ware. Sp an LEDs assoc iated with non-ad ministered fac ilities (C and D, in this example) should b e off. 3. Perform a test c all, if d esired . Fiber Link Administration Form This form ad ministers fib er links, eac h of whic h is identified b y a fiber numb er. NOTE: Fib er link ad ministration only ap p lies to R5r and later c onfig urations. Port networks (PNs) are c onnec ted via d irec t fib er link c onnec tions or throug h a c enter stag e switc h (CSS) to p rovid e the interc onnec tion of p ort networks req uired for voic e/d ata information transfer. The CSS is c omp osed of switc h nod es that c an b e interc onnec ted in one or two levels to provid e Port Network Connec tivity (PNC). The CSS p rovides c irc uit-switc hed c onnec tivity for voic e and d ata c ommunic ations as well as pac ket-switc hed c onnec tivity. Fib er link ad ministration p ermits an ad ministration of translation d ata assoc iated with a
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-37 Administer Fiber Links (Release 8r Only) 3 switc h c onnec tion (suc h as op tic al fiber, metallic c able, or DS1CONV c irc uit packs and DS1 facility links between two endpoints). The two fiber endpoints can be: nAn exp ansion interfac e (EI) c irc uit p ac k nA switc h nod e interfac e (SNI) c irc uit p ac k NOTE: Only one ad ministrative terminal c an ad minister fiber links at a time; others c an d isp lay fib er link information. Administration commands Use the following c ommand s to ad minister the Fiber Link Ad ministration form. PNCs have three d ifferent reliab ility c onfig urations (one for eac h system reliability configuration) as follows: Simplex PNC For Simp lex PNC, PNC Dup lic ation is d isab led on the System-Parameters Customer-Op tions form and Op eration of Dup lic ation is d isab led on the Dup lic ation-Related System-Parameters form.Action Object Qualifier 1 1. Brackets [ ] ind ic ate the q ualifier is op tional. Sing le quotes (‘ ’) indicate the text inside the quote must b e entered exactly as shown or an ab b reviated form of the word may b e entered. ad d fib er-linklink numb er or [‘next’] c hang e fib er-link link numb er d isp lay fib er-link link numb er list fib er-link link numb er remove fib er-link link numb er System Configuration PNC Stand ard Reliability Simp lex Fibers Hig h Reliab ility Simp lex Fibers to Exp ansion Port Networks and Dup lic ated Fib ers b etween Proc essor Port N e t w o rk s (PPN ) a n d Sw it c h N o d e s Critical Reliab ility Dup licated Fib ers
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-38 Administer Fiber Links (Release 8r Only) 3 Administration of PNC Duplication The PNC Dup lic ation feature is enab led on the System-Parameters Customer-Op tions form and Op eration of Dup lic ation is enab led on the Dup lic ation-Related System-Parameters form. When PNC Dup lic ation is enab led on the System-Parameters Customer-Op tions form, the following ad ministration forms c hang e: nCab inet form — Ad d itional field s ap p ear to allow ad ministration of switc h nod es to A-PNC and B-PNC sid es of the CSS. The B-PNC is the d up lic ated hard ware for the A-PNC. Either the A-PNC or the B-PNC c an p rovid e full c ustomized servic e. B-PNC c annot b e used in a simp lex PNC configuration. Pairing of switc h nodes is also defined here. nFi b e r L i n k f o r m — Ad d itional field s ap p ear to allow administration of fib er links on the B-PNC sid e of the CSS. If an end p oint on the A-PNC side is ad ministered as an SNI, its c orresp ond ing endp oint on the B-PNC sid e is d etermined (if switc h nodes are paired in the c ab inet form p rior to this ad ministration) and d isp layed . However, ad ministration of the d up lic ate B-PNC link is not enforc ed until dup lic ation is in full op eration. nDup lic ation-Related System-Parameters form — An ad d itional field ap p ears to enable op eration of PNC d uplic ation. Form instructions Page 1 of the form Screen 3-10. Fiber Link Administration form Basic Fiber Link Administration. The following fields appear: nFiber Link # — Disp lay-only field . From the c ommand line, enter a 1- to 3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and its d up lic ate if ap prop riate. Page 1 of 1 FIBER LINK ADMINISTRATION Fiber Link #: 1 Is one endpoint remoted via a DS1 Converter Complex? ___ ENDPOINT-1 ENDPOINT-2 (A-PNC) (A-PNC) Board Location: _____ Board Location: _____ Board Type: xxx Board Type: xxx
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-39 Administer Fiber Links (Release 8r Only) 3 nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of an SNI or EI b oard that is the first endp oint of the fib er link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in Endpoint-1. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of an SNI or EI b oard that is the sec ond end point of the fib er link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in Endpoint-2. nIs one endpoint remoted via a DS1 Converter Complex? — En t e r y to sp ec ify that a DS1 Converter c omp lex is used to remote one end p oint. If a y is entered , A-PNC DS1 Converter c irc uit p ac k Loc ation must b e ad ministered on Pag e 1. A-PNC DS1 Converter c irc uit pac k Typ e d isp lays. A-PNC DS1 Converter (DS1CONV) Attrib utes must b e ad ministered on Pag e 2 of this form. Duplicated Fiber Link Administration. Screen 3-11. Fiber Link Administration form (page 1 of 3) The following fields appear when Administration of PNC Duplication is enab led on the System-Parameters Customer-Op tions form: nFiber Link # — Disp lay-only field . From the c ommand line, enter a 1- to 3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and its d up lic ate if ap prop riate. add fiber-link next Page 1 of 3 FIBER LINK ADMINISTRATION Fiber Link #: 1 Is one endpoint remoted via DS1 Converter Complex? yes ENDPOINT-1 ENDPOINT-2 (A-PNC) (A-PNC) Board Location: 01E01 Board Location: 02A01 Board Type: ei Board Type: ei DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 ENDPOINT-1 ENDPOINT-2 (B-PNC) (B-PNC) Board Location: 01D01 Board Location: 02A02 Board Type: ei Board Type: ei DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-40 Administer Fiber Links (Release 8r Only) 3 nIs one endpoint remoted via DS1 Converter Complex? — En t e r yes to sp ec ify that a DS1 c onverter c omp lex is used to remote one end p oint. If yes is entered , A-PNC and B-PNC DS1 Converter (DS1CONV) Attrib utes must b e ad ministered on Pag es 2 and 3 (resp ec tively) of the form. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of a c irc uit pac k in the first end p oint of the d up lic ate fib er link. End p oint-1’s d up lic ate along with End p oint-2’s d up lic ate make up the d up lic ate fib er link c alled the B-PNC link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in End p oint-1. The c irc uit p ac k typ e in Endp oint-1 (A-PNC) and End p oint-1 (B-PNC) must be the same. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit p ac k in the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with End p oint-2’s d uplic ate make up the d up lic ate fib er link c alled the B-PNC link. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k in End p oint-1. The c irc uit p ac k typ e in Endp oint-1 (A-PNC) and End p oint-1 (B-PNC) must b e the same. This field is upd ated via the Chang e Circ uit-pac ks c ommand. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of a c irc uit p ac k in the sec ond end p oint of the d up lic ate fiber link. Endpoint-2’s duplicate along with Endpoint-1’s duplicate make up the d up lic ate fib er link c alled the B-PNC link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in End p oint-2. The c irc uit p ac k typ e in Endp oint-2 (A-PNC) and End p oint-2 (B-PNC) must be the same. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit pac k in the sec ond endpoint of the duplicate fiber link. Endpoint-2’s duplicate along with End p oint-1’s d uplic ate make up the d up lic ate fib er link c alled the B-PNC link. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k in End p oint-2. The c irc uit p ac k typ e in Endp oint-2 (A-PNC) and End p oint-2 (B-PNC) must b e the same. This field is upd ated via the Chang e Circ uit-pac ks c ommand.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-41 Administer Fiber Links (Release 8r Only) 3 DS1C Converter Complex Administration for TN574 Circuit Packs. Screen 3-12. Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter Complex Administration) (page 2 of 3) The following DS1 Converter Comp lex field s ap p ear on Pag e 2 when the Is one endpoint remoted via a DS1 Converter Complex field is y . NOTE: When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s display. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted to the first end point of the fib er link. This is entered on Pag e 1 and d isp lays on Pag e 2. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k for the first end p oint. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted to the sec ond end p oint of the fib er link. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k for the sec ond end point. This field is up d ated via the Chang e Circ uit-p ac ks c ommand . add fiber-link next Page 2 of 3 FIBER LINK ADMINISTRATION A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes no no no Passes Far-end Clock? yes yes yes yes Digital Data Compatible? yes yes yes yes Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs Framing Mode: esf esf esf esf DS1CONV-1 Line Compensation: 1 1 1 1 DS1CONV-2 Line Compensation: 1 1 1 1 Facility A Circuit ID: 09876543
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-42 Administer Fiber Links (Release 8r Only) 3 nFacility Installed — Enter yes in the B, C, and D c olumns und er the DS1 Converter Fac ilities head ing to ind ic ate that this DS1 fac ility is p hysic ally installed . At least fac ility A must b e installed within the c onverter c omp lex. Default is yes for Fac ility A. nPasses Far-end Clock — Enter yes in the B, C, and D c olumns und er the DS1 Converter Fac ilities heading to ind ic ate that this DS1 fac ility is suitab le to b e used as a c loc k sourc e. If the DS1 sig nal d oes not c ome d irec tly from the far end c onverter c irc uit pac k or the network (suc h as when the sig nal is c onverted from d ig ital to analog and then bac k to digital), enter no .” Default is yes for Fac ility A. This field d etermines whether the DS1 c onverter c irc uit p ac k c an use rec eive DS1 sig nal timing to time the transmit fib er sig nal. This is nec essary for p assing timing from a master PN to a slave PN ac ross a Converter Comp lex. nDigital Data Compatible — Enter yes (d efault) in the B, C, and D c olumns und er the DS1 Converter Fac ilities head ing to ind ic ate that this DS1 fac ility is suitab le for transmission of d ig ital d ata. At least Fac ility A must b e suitab le for transmission of d ig ital d ata. If Customer Premises Eq uip ment that alters d ig ital d ata exists on this fac ility (suc h as with a channel exp ansion multip lexer), enter no . nLine Coding — Enter the line c od ing format, ami-zcs (d efault), or ami-basic , b8zs , or hdb3 in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility. When ami-zc s line c od ing is used , all-zero b ytes are p revented from b eing transmitted on the DS1 fac ility b ec ause a 1 is arb itrarily written into the sec ond p osition of eac h b yte. Thus, if no measures are taken to p revent it, ami-zc s line c oding results in data c orruption. The DS1CONV circuit pac k p rotec ts the p ac ket fac ility (one of up to four fac ilities d ynamic ally alloc ated b y the DS1CONV c irc uit pac k) from c orrup tion throug h a sp ec ial esc ap e mec hanism. When b 8zs line c od ing is used , it maintains DS1 fac ility’s ones-d ensity req uirements by enc od ing a zero d ata b yte into a sp ec ific uniq ue p attern of b ip olar violations on the DS1 line. The op p osite end rec og nizes this p attern and rep lac es it with a zero d ata b yte when the data is rec overed at the rec eiving end . NOTE: Note that althoug h the esf framing mod e and b 8zs line c od ing are the p referab le modes of op eration, you should c onfirm that the DS1 fac ilities sup p ort them b efore selec ting this line c oding .
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-43 Administer Fiber Links (Release 8r Only) 3 nFraming Mode — Enter the framing format, esf (d efault) or d4 , in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility. NOTE: The D4 format is sup p orted by the Converter c irc uit p ac ks, b ut b ec ause of p rob lems inherent with this format (sp ec ific ally, inability to frame on a b it stream that c ontains d ata that emulates the D4 framing pattern), its use is d isc ourag ed . nDS1CONV-1 Line Compensation — Enter the line c omp ensation (1 to 5 ) in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility c onnec ted to ENDPOINT-1 (see Ta b l e 3 - 8 ). The DS1 line sig nal is p re-eq ualized at the transmitter so that DS1 line p ulses are the c orrec t amp litud e and shap e when they reac h the Network Interfac e. The amount of eq ualization nec essary is d etermined b y the d istanc e to the Network Interfac e (when the end p oint supp lies a DSX-1 interfac e) and also b y the typ e of wiring used to c onnec t to the Network Interfac e. The typ es of wiring allowed are 22 g aug e ABAM (shield ed twisted p air) c ab le, 24 g aug e Premises Distrib ution System (PDS) wiring, and 26 g aug e PDS wiring . NOTE: The line eq ualization setting d efaults to 2 and remains in effec t until c hang ed by administration. Bec ause inc orrec t eq ualizer settings c ause a p otentially hig her error rate on the DS1 fac ility, it is nec essary to p rovid e the c orrec t setting s b ased on the d istanc e to the Network interfac e. If it is a TN574 c irc uit p ac k, the default for all fac ilities is 1 . Table 3-8. Distance to DSX-1 Interface (in feet) Equalizer Setting 22 AWG ABAM & 24 AWG PDS 26 AWG PDS 1 1 to 133 0 to 90 2 133 to 266 90 to 180 3 266 to 399 180 to 270 4 399 to 533 270 to 360 5 533 to 655 360 to 450 Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Accessing and Activating the System 3-44 Administer Fiber Links (Release 8r Only) 3 nDS1CONV-2 Line Compensation — Enter the line c omp ensation (1 to 5 ) in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility c onnec ted to ENDPOINT-2 (see Ta b l e 3 - 8 ). The DS1 line sig nal is p re-equalized at the transmitter so that DS1 line p ulses are the c orrec t amp litud e and shape when they reac h the Network Interfac e. The amount of eq ualization nec essary is d etermined b y the d istanc e to the Network Interfac e (when the end point sup p lies a DSX-1 interfac e) and also b y the typ e of wiring used to c onnec t to the Network Interfac e. The types of wiring allowed are 22-gaug e ABAM (shield ed twisted p air) c ab le, 24-g aug e Premises Distrib ution System (PDS) wiring , and 26-g aug e PDS wiring . nFacility A Circuit ID — Disp lays when the value in Facility Installed for Fac ility A is yes . Enter up to 40 c harac ters to id entify the c ab inet, c arrier, and slot of the DS1 Converter c irc uit p ac k’s p hysic al loc ation. Similarly, Fac ility B Circ uit ID, Fac ility C Circ uit ID, and Fac ility D Circ uit ID field s display for eac h of the DS1 Converter Fac ilities when yes is entered in the c orresp ond ing Fac ility Installed field . Duplicated DS1C Converter Complex Administration for TN574 Circuit Packs. Screen 3-13. Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1 Converter Complex Administration) (page 3 of 3) Pag e 3 ap p ears when the Is one end p oint remoted via a DS1 Converter Comp lex field is yes and d up lic ation is enab led . add fiber-link next Page 3 of 3 FIBER LINK ADMINISTRATION B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes no no no Passes Far-end Clock? yes yes yes yes Digital Data Compatible? yes yes yes yes Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs Framing Mode: esf esf esf esf DS1CONV-1 Line Compensation: 1 1 1 1 DS1CONV-2 Line Compensation: 1 1 1 1 Facility B Circuit ID: 01112343