Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-67 List of Circuit Packs 5 TN436B Direc t Inward Dialing Trunk (Australia) Port TN437 Tie Trunk (Australia, rep lac ed b y TN760D) Port TN438B Central Offic e Trunk (Australia) Port TN439 Tie Trunk (Australia and Jap an) Port TN447 Central Offic e Trunk Port TN457 Sp eec h Synthesizer, British Eng lish Servic e TN458 Tie Trunk for the United Kingdom (replaced by TN760D)Po r t TN459B Direc t Inward Dialing Trunk for the United King d om Port TN464C/D/E/F DS1 Interfac e - T1, 24 Channel - E1, 32 Channel Port TN465/B/C Central Offic e Trunk (Multi-Country, 16-kHz PPM) Port TN467 Analog Line for the United King d om and Australia (rep lac ed b y TN2183)Po r t TN468BAnalog Line for the United King d om and Australia (rep lac ed b y TN2183) (16 p orts)Po r t TN479 Analog Line (16 ports)Po r t TN497 Tie Trunk - Italy Port TN553 Pac ket Data Line Port TN556/B/C/D ISDN Line (12-BRI-S-NT) Port TN570/B/C Exp ansion Interfac e Port TN572 Switc h-Node Cloc k for r only Control TN573B Switch-Node Interface for r only Control TN 5 7 4DS1 Converter (rep lac ed by TN1654) (G3rV2 and later) Po r t TN722B DS1 Tie Trunk (rep lac ed b y TN767B/C/D/E) (24 p orts) Trunk TN725B Sp eec h Synthesizer, United States Eng lishSe r v ic e TN726B Data Line (8 p orts) Line TN735 MET Line (4 p orts) Line TN 7 4 2Analog Line (8 p orts) (rep lac ed b y TN746B) Line Table 5-19. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-68 List of Circuit Packs 5 TN744B/C/DCall Classifier Tone Detec tor, Multi-CountrySe r v ic e TN746B Analog Line (US and Canad a Offer A Only) (16 p orts) Line TN747B Central Offic e Trunk(8) Trunk TN748B/C/D Tone Detec tor (rep lac ed b y TN2182B) Se r v ic e TN750B/C Announc ementSe r v ic e TN753B Direc t Inward Dialing Trunk (8 p orts) Trunk TN753/B Direc t Inward Dialing Trunk Port TN754/B/C Dig ital Line 4-Wire DCP Port TN755/B Neon Power Unit Power TN 7 5 6Tone Detec tor/Generator (XE) (rep lac ed b y TN2182B) Servic e TN758 Pooled Modem (2 p orts) Port TN760D/E Tie Trunk (4 p orts) Trunk TN762B Hyb rid Line (8 p orts) Line TN763B/C/D Auxiliary Trunk (4 ports) Trunk TN767B/C/D/E DS1 Interfac e - T1, 24 Channel Port TN768 Tone-Cloc k (rep lac ed b y TN2182B) Control TN769 Analog Line (8 p orts) (Neon) Line TN771B/C/D Maintenanc e Test Servic e TN773 Proc essor Control TN775/B/C Maintenanc e (EPN) Servic e TN776 Exp ansion Interfac e (si only) Port TN780 Tone Cloc k (all mod els exc ep t c si, Stratum 3) Control TN787F/G/H/J/ KMultimed ia Interfac e Servic e TN788B Multimed ia Voic e Cond itioner Servic e TN789 Rad io Controller Control TN790B Processor (R7 si and later) Control TN791 Analog Guest Line (16 Port) Line Table 5-19. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-69 List of Circuit Packs 5 TN792 Duplic ation Interfac e (for TN790B Proc essor Circ uit Pac ks, si only) Control TN793B 24-Port Analog Line w/CID Line TN794 Network Control/Pac ket Interfac e for si onlyControl TN797B Analog Trunk and Line Comb o Port TN799B Control-LAN (C-LAN) Port TN800 Multi-Ap p lic ation Platform for DEFINITY (MAPD) Port TN801 Multi-Ap p lic ation Platform for DEFINITY (MAPD) Port TN802B IP Interfac e Assemb ly Port TN1648/B System Ac c ess/Maintenanc e (SYSAM) Control TN1650BMemory (32MB) for r only Control TN1654 DS1 Converter - T1, 24 Channel/E1, 32 Channel Port TN1655 Pac ket Interfac e Control TN1657 Disk Drive Control TN2135 Analog Line Port TN2136 Dig ital Line 2-Wire DCP Port TN2138 Central Offic e Trunk (Italy, Loop Start) Port TN2139 Direc t Inward Dialing Trunk (Italy) Port TN2140/B Tie Trunk (Hung ary, Italy) Port TN2144 Analog Line (The Netherlands, rep lac ed b y TN2183) (16 p ort)Po r t TN2146 Direc t Inward Dialing trunk (Belg ium and The Netherland s)Po r t TN2147/C Central Offic e Trunk (without PPM, rep lac es TN447) Port TN2149Analog Line for Belg ium (rep lac ed b y TN2183) (16 port)Po r t TN2180 Analog Line Port TN2181 Dig ital Line (16-p orts DCP-2-Wire) Port TN2182/B Tone-Cloc k -Tone Detec tor and Call Classifier Control Table 5-19. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-70 List of Circuit Packs 5 TN2183 Analog Line, Multi Country with DSLACPo r t TN2184 DIOD Trunk (Germany) Port TN2185B ISDN (4-Wire S/T-TE Interfac e, 8 p orts) Port TN2198 ISDN Line (4-Wire BRI-U-NT, 8 p orts) Port TN2199 Central Offic e Trunk (Russia) Port TN2202 50-Hz Ring Generator (Franc e) Power TN2207 DS1 Interfac e - T1, 24 Channel - E1, 32 Channel Port TN2209 Tie Trunk (Russia) Port TN2210 Tone Generator (1780 Hz)Se r v ic e TN2211 Op tic al Drive (replaces TN1656)Control TN2214B Dig ital Line, 24-Port, 2-Wire DCP - Categ ory B Port TN2215 Analog Line, 16-Port, 2-Wire - Categ ory B Port TN2224/B Digital Line, 24-Port, 2-Wire DCP Port TN2301 Log ic Switc h (for r only, Survivab le Remote EPN) Switc h TN2305 DEFINITY ATM Interfac e (Multi-Mode fiber, Port Network Connec tivity, CES Trunk)Po r t TN 2 3 0 6 D EFI N I TY A TM I n t e rf a c e (Si n g l e -M o d e Fi b e r , Po rt Network Connec tivity, CES Trunk))Po r t TN2313 DS1 Interfac e Port TN2464 DS1 Interfac e - T1, 24 Channel - E1, 32 Channel Port TN2793 Analog Line 24-Port - Categ ory B Port UN331B Processor Control UN332C MSS Network Control (for r only; used with the TN2211 Op tic al Drive)Control Table 5-19. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-71 Add CO, FX, WATS, and PCOL 5 Add CO, FX, WATS, and PCOL Requirements Each Central Office (CO), Foreign Exchange (FX), Wide Area Telecommunications Service (WATS), or Personal Central Office Line (PCOL) trunk is connected to 1 port of either an 8-port TN747 or to 1 of an assortment of non-United States CO Trunk circuit packs. Installation 1. See ‘‘Off-Premises Station Wiring’’ on p ag e 5-32 and install a CO trunk c irc uit p ac k in the assigned c arrier slot (if an ad d itional c irc uit p ac k is req uired ). 2. Ad minister the Trunk Group sc reens listed und er CO, FX, WATS, or PCOL Trunk Group in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 3. Determine the p ort assig nment of the trunk from Trunk Group sc reen. For examp le: Add DID Trunks Requirements Each Direct Inward Dial (DID) trunk connects to 1 port of an 8-port TN753 or to 1 of an assortment of non-United States DID trunk circuit packs. Installation 1. Determine the p ort assig nment of the trunk from Trunk Group form. For examp le:3 A 07 01 Cab inet (Port Network)Carrier Slot NumberPo r t Numb er 3 A 07 01 Cab inet (Port Network)Carrier Slot NumberPo r t Numb er
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-72 Add Tie Trunks 5 2. See‘‘Off-Premises Station Wiring’’ on p age 5-32 and install a DID trunk c irc uit p ac k in assigned c arrier slot (if an ad d itional c irc uit p ac k is req uired ). 3. Ad minister DID Trunk Group sc reens in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. Add Tie Trunks Requirements Each tie trunk connects to 1 port of a 4-port TN760 or to an assortment of non-United States tie trunk circuit packs. Installation 1. Determine the p ort assig nment of the trunk from Trunk Group form 2. Install a TN760 or a non-United States tie trunk c irc uit p ac k in the assig ned c arrier slot (if an add itional c irc uit pac k is req uired ). 3. For c ustomer-owned (not leased ) tie-trunk fac ilities (suc h as c amp us environments), TN760 c irc uit p ac ks p rovid e sig naling c ap ab ilities b eyond those sp ec ified b y the ind ustry-wid e E & M stand ard . Use Fig ure 5-32 and Tab le 5-20 to c hoose the p referred sig naling format, set switc hes on the TN760 c irc uit p ac k, and ad minister the p ort. 4.Ad minister forms listed under “ Tie Trunk Group ” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 3 A 07 01 Cab inet (Port Network)Carrier Slot NumberPo r t Numb er
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-73 Add Tie Trunks 5 Figure 5-32. Tie Trunk Circuit Packs (Component Side) Table 5-20. Tie Trunk Option Switch Settings and Administration Installation Situation Preferred Signaling FormatE&M/SMPLX SwitchProt/Unprot SwitchAdministered Port Circumstance To System Far-End Co-Loc ated DEFINITY E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1 Comp atib le Stand ard Compatible Inter-Build ing DEFINITY Protec ted Typ e 1Protec ted Typ e 1E&M Pro te c t e d Typ e 1 Comp atib le Stand ard Pl u sCompatible Protec tion Unit Co-Loc ated Net IntegratedE&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1 Stand ard UNPROT PROTSMPLX E&M SMPLX E&MSMPLX E&MSMPLX E&M4 3 2 1 PORT 4 PORT 3 PORT 2 PORT 1
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-74 Add DS1 Tie and OPS 5 Add DS1 Tie and OPS The TN722B DS1 Tie Trunk, TN767C (or later) DS1 Interface, and TN464C DS1 Interface circuit packs provide connections to a 1.544 Mbps or 2.08 Mbps DS1 facility as 24 independent 64 kbps trunks. When upgrading from a TN722 to a TN767C: 1. Remove all TN722 trunk memb ers from affec ted trunk g roup s. 2. Type remove ds1 PCSS (PCSS is the slot containing the TN722). 3. Remove the TN722 c irc uit p ac k. 4. Put the TN767C c irc uit p ac k into the same slot. 5. Wait until the red LED g oes off. The hard ware tests take 12 to 20 sec ond s to run. When the red LED g oes off, the tests have c omp leted . 6. If the red LED stays on, reseat the b oard and rep eat this step . 7. Type add ds1 PCSS . 8. Continue with ap p rop riate p roc ed ures to set up memb ers of trunk g roups. Service Interruption Adding DS1 tie-trunk service may require a service interruption; notify the customer in advance as to when the addition will be carried out. Disable Scheduled Maintenance and Alarm Origination to INADS 1. To p revent sc hed uled d aily maintenanc e from interfering with the up d ate or up g rad e, typ e change system-parameters maintenance and p ress En t e r. 2. If sc heduled maintenanc e has b eg un, set the Stop Time field to 1 minute after the c urrent time. or If sc hed uled maintenanc e has not b eg un, set the Start Time field to a time after the upgrade is completed. For example, if you start the upgrade at 8:00 p .m. and the up g rad e takes 90 minutes, set the Start Time field to 21:30. !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-75 Add DS1 Tie and OPS 5 3. Type neither in the Alarm Origination to OSS Numbers field and p ress En t e r . NOTE: For some software load s, set the Alarm Origination Activated field to n and set the Cleared Alarm Notification and Restart Notification fields to disable or n before pressing En t e r. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard or removab le med ia. 3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. If ad ministered rec orded announc ements are listed , typ e list configuration software-version p ress En t e r . Chec k Pag e 2 of this form to see when the announc ements were last saved. To save the c urrent announc ements, typ e save announcements and p ress En te r . Shut Down DEFINITY LAN Gateway System !WARNING: Neg lec ting to shut d own a DEFINITY LAN Gateway assemb ly b efore p owering d own the system c ab inet where it resides c an d amage the LAN Gateway disk. !CAUTION: Save the system p arameters if you p lan to reuse the c urrent system. 1. Log onto the DEFINITY LAN Gateway. 2. When the main menu ap p ears, selec t Maintenance. 3. Select Reset System from the Maintenance menu. 4. Select Shutdown from the Reset System menu.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-76 Add DS1 Tie and OPS 5 Shut Down DEFINITY AUDIX System !WARNING: Neg lec ting to shut d own an AUDIX assemb ly b efore p owering down the system c ab inet where it resides c an d amage the AUDIX d isk. 1. If a DEFINITY AUDIX resid es in the system to be up g rad ed , shut d own the AUDIX assemb ly and allow the d isk to c omp letely sp in d own. Power Down System NOTE: Power d own the PPN only if the existing Tone-Cloc k is b eing rep lac ed in a standard reliab ility system. 1. At the PPN, set the main c irc uit b reaker to OFF. 2. At eac h EPN, set the main c irc uit breaker to OFF. Add Circuit Packs 1. Determine the port assignments of the circuit packs to be added. 2. Install the TN722B DS1 Tie Trunk, the TN767C DS1 Interfac e, or TN464C DS1 Interfac e c irc uit p ac k in assig ned c arrier slot. 3. Rep lac e an existing TN756 Tone Detec tor/Generator c irc uit p ac k with: a. TN768, TN780, or a non-United States TN419B Tone-Cloc k b . TN748B or a non-United States TN420B Tone Detec tor Install Cables Install H600-307 cable from the cabinet to a Channel Service Unit (CSU) and install cables from the CSU to the MDF as required. Power Up System 1. At eac h EPN, set the main c irc uit breaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms the level 4 reb ooting p roc ess, load ing the system translations from the translation c ard or removab le med ia. Reb ooting takes 8 to 11 minutes.