    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-15 Screens and Commands 
    3
    Screen 3-1. Typical Start-up Messages (Release 8r)
    2. About 2 minutes after REBOOT PERFORMED
     d isp lays, the screen d isp lays:
    Login:
    Screens and Commands
    Screens
    The system is ad ministered  using  sc reens d isp layed  on the terminal. The 
    sc reens are used  to ad d , c hang e, d isp lay, list d ata, and  to remove system and  
    telep hone features. To ac c ess a sc reen, enter a valid system c ommand in 
    resp onse to the Command: 
    prompt.
    CONTROL STATUS TEST
    DCACHE TEST
    ICACHE TEST
    WRITE BUFFER TEST
    BTO TEST
    INTERNAL REGISTER TESTPASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED MEM CONFIG TEST
    MEMORY FUNCTIONAL TEST
    MEMORY MODULE A PARITY TESTMEMORY MODULE A STUCK BIT TEST
    MEMORY MODULE A BURST TEST
    MEMORY MODULE B PARITY TESTMEMORY MODULE B STUCK BIT TEST
    MEMORY MODULE B BURST TEST
    MEMORY MODULE C PARITY TESTMEMORY MODULE C STUCK BIT TEST
    MEMORY MODULE C BURST TEST
    VIRTUAL MEMORY TEST
    EXCEPTION TEST
    TIMER TEST
    MTP TEST
    SANITY TIMER TEST
    ADDRESS MATCHER TEST
    FLASH TEXT CHECKSUM TEST
    RAM DATA CHECKSUM TEST
    RESET 4 (REBOOT PERFORMED)LOOP DATA TEST
    DUART TEST
    ROM CHECKSUM TEST 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-16 System Administration 
    3
    Commands
    System c ommand s are stand ard word s and phrases instruc ting the system to 
    p erform a spec ific  func tion. The c ommand s are arranged  in a hierarc hy of 
    keyword s; that is, enter 1 c ommand  to go to a d ifferent level. The c ommand s 
    c ontain three parts: ACTION, OBJECT, and  QUALIFIER.
    nACTION is the first p art of the c ommand . When Command:
     ap p ears on the 
    sc reen. The ACTION sp ec ifies the op eration d esired . Examp les inc lude 
    add,
     duplicate,
     change,
     remove,
     display,
     list,
     and save.
    nOBJECT is the sec ond  p art of the c ommand  and  sp ec ifies the p artic ular 
    ob jec t to b e ad ministered . Typ ic al entries are hunt-group,
     coverage 
    path,
     and station.
    nQUALIFIER is the last p art of the c ommand . It is 1 or more word s or d ig its 
    used  to further id entify or c omp lete the OBJECT. For examp le, hunt g roup  
    15 or station 3600, where 15 and  3600 are q ualifiers.
    An examp le of the c ommand  line req uired  to ad d  a station with extension numb er 
    1234 is add station 1234
    . In this examp le, add
     is the ACTION, station
     is the 
    OBJECT, and  1234
     is the QUALIFIER. In the c ommand  line, spac es are req uired  
    b etween the ACTION, OBJECT, and  QUALIFIER.
    To save time, enter enoug h letters for eac h p art of the c ommand to make it 
    uniq ue. For examp le, if you want to enter the c ommand  change 
    system-parameters country-options
    , typ ing  cha sys coun
     is ac c ep tab le. 
    However, typ ing  the entire c ommand  is always b est.
    NOTE:
    The c raft log in may not b e allowed  to p erform some of the step s needed  to 
    initialize the system. If ac c ess is d enied  to some of these p roc ed ures, 
    c ontac t your Luc ent Tec hnologies representative for assistanc e.
    Getting Help
    Use the Help  key for a list of options and  the Canc el key to b ac k out of any 
    c ommand . Refer to DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e, for d etailed  p roc ed ures.
    System Administration
    NOTE:
    An “ init”  log in is req uired  to p erform the following . Contac t the reg ional 
    CSA (Customer Software Assoc iate) to assig n the Offer Categ ory op tion. 
    Maintenanc e c ap abilities to initialize the system and  ac c ess to either an 
    internal or external mod em are the only c ommand  op tions availab le until 
    the Offer Categ ory op tion is set. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-17 Set Country Options 
    3
    Log into the System
    1. Verify the sc reen d isp lays: Login:
    2. Log in as craft
    .
    3. To use Ac cess Security Gateway (ASG), see Appendix E, ‘‘
    Ac cess 
    Sec urity Gateway’’.
    4. Verify the sc reen d isp lays: password
    :
    If the system rec og nizes the log in and  p assword  name, the sc reen 
    d isp lays the software version.
    5. Verify the sc reen d isp lay is similar to:
    Terminal Type (513, 715, 4410, 4425, VT220): [513]
    6. Typ e the numb er of the manag ement terminal and  p ress 
    En te r.
    7. Verify the sc reen d isp lays: Command
    :
    NOTE:
    The following  sec tions d esc rib e some of the p roc ed ures used  to ac c ess 
    and  c hang e c ertain op tions. These sec tions are not intend ed  to rep lac e or 
    mod ify the instruc tions p rovid ed  in DEFINITY Enterp rise Communic ations 
    Server Release 8 Ad ministrator’s Guid e.
    Set Country Options
    Certain c ountry options need  to b e set to turn red  failure ind ic ation LEDs off.
    1. Verify the sc reen d isp lays: Command:
    2. Type change system-parameters country options 
    and press 
    En t e r .
    A sc reen similar to Sc reen 3-2 is d isp layed  on the terminal. The c ursor is 
    set on the Companding Mode
     line. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-18 Set Country Options 
    3
    Screen 3-2. Typical System Parameters Country-Options Screen
    3. The d efault c omp and ing  mode is m-Law (mu-Law). If the c ountry uses 
    A-Law c omp and ing , typ e A-Law.
    4. Press 
    En t e r when this information is c orrec t.
    Other items eventually need  to b e entered  on this sc reen, b ut this is all that 
    must b e d one to turn the red  alarm LEDs off. Refer to Tab le 3-5
     for a list of 
    the country cod es. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-19 Set Country Options 
    3
    5. If all red  LEDs d o not g o off, reseat (unp lug  and  reinsert) any 
    purple-labeled circuit packs displaying red LEDs.
    !CAUTION:
    To avoid  a d isk c rash, never reset the DEFINITY AUDIX System 
    without first shutting  it d own. Shut d own the DEFINITY AUDIX System 
    (and  allow the d isk to c omp letely spin d own) b efore unp lug g ing  the 
    assemb ly. See ‘‘
    DEFINITY AUDIX Power Proc ed ures’’ on p ag e 3-50 
    for the p rop er p roc ed ures.
    6. If the red  LEDs still d o not g o off, refer to D EFI N I TY En t e rp r i se  
    Communic ations Server Release 8 Maintenanc e for R8r, or to DEFINITY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si.
    NOTE:
    Ig nore the red  alarm ind ic ation LED on the TN767 or TN464 DS1 
    c irc uit pac k until after the DS1 c irc uit p ac k is ad ministered . Alarms 
    will appear in the Alarm Log when power is applied to the system 
    before all equipment connecting to port circuit packs is installed. 
    Normally, some alarms will be logged when power is applied to the 
    system, b ut should  b e resolved  q uic kly. If no eq uip ment is 
    c onnec ted  to the p ort c irc uit p ac ks, alarms assoc iated  with these 
    p orts c an take up  to four hours to log , b ut will c lear automatic ally 
    after all eq uip ment is installed  and  op erating  c orrec tly.
    Table 3-5. Country Codes
    Country Code Country Code
    USA 1 Franc e 12
    Australia 2 Germany 13
    Jap an 3 Czec hoslovakia 14
    Italy 4 Russia 15
    The Netherland s 5 Arg entina 16
    Sing ap ore 6 Greec e 17
    Mexic o 7 China 18
    Belg ium 8 Hong Kong 19
    Saud i Arab ia 9 Thailand 20
    United  Kingd om 10 Mac ed onia 21
    Sp a in 1 1 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-20 Set Country Options 
    3
    Change Craft Password
    The p assword  for the c raft log in must b e c hang ed  b y the installing  tec hnic ian to 
    p revent unauthorized  ad ministration c hang es.
    !CAUTION:
    After the password is changed, the new password must be safeguarded so 
    no unauthorized  ad ministration c hang es c an b e mad e. This p assword  
    M U ST N O T B E REVEAL ED  t o  t h e  c u s t o m e r  o r  t o  a n y  u n a u t h o r iz e d  p e r s o n .
    1. Login as craft
     and type change password craft
    . Press 
    En t e r. 
    Screen 3-3. Typical Change Password Screen
    2. Verify the Password  Ad ministration sc reen d isp lays. See Sc reen 3-3
    . The 
    c ursor is p ositioned  on Password for Login Making Change:
    3. Typ e the p assword  for the c raft log in (assig ned  as c rftp w when the system 
    is shipped) and press 
    En te r. The c ursor is p ositioned  on Login’s 
    Password
    :.
    4. Enter the new p assword . Valid  p assword s c onsist of a c omb ination of 4 to 
    11 alp ha or numeric  c harac ters. At least 1 letter and  1 numb er must b e 
    used  in eac h p assword . Press 
    En t e r. 
    5. The cursor is positioned on Reenter Login’s Password
    :. Typ e the 
    new p assword  ag ain and  p ress 
    En te r.
    6. Verify the sc reen d isp lays:
    command successfully completed 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-21 Set Country Options 
    3
    Set Daylight Savings Rules
    You c an set up  to 15 c ustomized d aylig ht saving s time rules. If you have switc hes 
    in several d ifferent time zones, you c an set up  rules for eac h. A d aylig ht saving s 
    time rule sp ec ifies the exac t time when you want to transition to and  from daylig ht 
    saving s time. It also spec ifies the inc rement at whic h to transition. 
    NOTE:
    The d efault d aylig ht saving s rule is 0
    , no d aylig ht saving s.
    1. Type change daylight-savings-rules
     and press 
    En t e r.
    2. Type the appropriate start and stop information in the Change Day
    , 
    Month
    , Date
    , Time
    , and  Increment
     field s for eac h rule. (for examp le, 
    1:00
     eq uals one hour) 
    NOTE:
    You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a 
    d aylig ht saving s rule if it is in use on either the Loc ations or Date and 
    Ti m e  s c re e n s .
    3. When d one, p ress 
    En te r.
     
    DAYLIGHT SAVINGS RULES
    Rule Change Day Month___Date Time____Increment
    0: No Daylight Savings
    1: Start: first Sunday
    ___ on or after April___ 1  at _2:00 01:00Stop:  first Sunday___ on or after October_ 25 at _2:002: Start: first _________ on or after _________ __ at __:__
    Stop:  first _________ on or after _________ __ at __:__
    3: Start: first______ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    4: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    5: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    6: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__
    7: Start: first _____ on or after ____ __ at __:__
    Stop:  first ______ on or after ____ __ at __:__ 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-22 Set Country Options 
    3
    Set Date and Time
    1. Type set time 
    and 
    press En t e r to b ring  up  the Date and  Time sc reen.
    Screen 3-4. Typical Date and Time Screen
    2. Typ e the d ay of the week in Eng lish (Sunday throug h Saturd ay). See 
    Tab le 3-6
     for Eng lish d ay of the week names.
    Table 3-6. English Day of the Week Names
    Day Number Day Name
    1Sunday
    2 Mond ay
    3Tuesday
    4 Wed nesd ay
    5Thursday
    6Friday
    7Saturday
     
                               DATE AND TIME
    DATE
     Day of the Week: Tuesday
    Month: FebruaryDay of the Month: 8 Year: 2000
    TIME
    Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-23 Set Country Options 
    3
    3. The c ursor is p ositioned  on the Month:
     field . Typ e the c urrent month in 
    Eng lish (January throug h Dec emb er). See Tab le 3-7
     for English month 
    names. After the month is entered, p ress 
    Ta b to move to next field .
    4. The c ursor is p ositioned  on the Day of the Month:
     field . Typ e the d ay 
    of month (1 through 31) and  p ress 
    Ta b to move to the next field.
    5. The c ursor is p ositioned  on the Year:
     field . Typ e the c urrent year and  
    p ress 
    TA B to move to the next field .
    6. The c ursor is p ositioned  on the Hour:
     field . Typ e the c urrent hour for a 
    24-hour c loc k. Press
     Ta b to move to the next field .
    7. The c ursor is p ositioned  on the Minute:
     field . Type c urrent minute (0 
    throug h 59). Sec ond s c annot b e set.
    8. Type standard
     or daylight savings
     in the Type
     field .
    9. Typ e the rule (numb er) in the Daylight Savings Rule
     field.
    10. Press 
    En t e r when the information is c orrec t.
    11. Typ e display time 
    and press 
    En te r  to verify d ate/time d ata.
    Table 3-7. English Month Names
    Month Number Month Name
    1 January
    2February
    3March
    4April
    5May
    6June
    7July
    8August
    9 Sep temb er
    10 Oc tob er
    11 November
    12 Dec emb er 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Accessing and Activating the System 
    3-24 Circuit Pack Administration 
    3
    Circuit Pack Administration
    After the eq uip ment is installed  (inc lud ing  c irc uit p ac ks), the c irc uit pac ks must 
    b e ad ministered . Refer to DEFINITY Enterp rise Communic ations Server Release 
    8 Ad ministrator’s Guid e for more information.
    The following information d esc ribes general ad ministration information:
    nUse the Circ uit Pac ks form to ad minister c irc uit p ac ks to c arrier slots. The 
    c irc uit p ac ks must b e installed  (or assig ned  using  the Circ uit Pac ks form) 
    before administering voice terminals, attendant consoles, or trunks.
    nEac h p ag e of the form rep resents 1 c arrier in the c ab inet shown on the 
    c ommand  line. For Release 8si, all c arriers and slots ap p ear even if they 
    are not inc lud ed  in the hard ware.
    nIt is not nec essary to fill in the Circ uit Pac ks form if the c irc uit p ac ks are 
    installed  at the time of ad ministration.
    nRefer to DEFINITY Communic ations System Generic  3 Planning  and 
    Config uration, 555-230-601, for more information ab out c irc uit pac k 
    ad ministration and port assig nment rec ord s.
    nFor initial installation, assig n c irc uit p ac ks to slots using the hard ware 
    configuration layout record from the fac tory or Customer Services 
    Org anization. Do not arb itrarily assig n c irc uit p ac ks to slots.
    nFor Release 8r, if the c arrier typ e ad ministered  on the Cab inet 
    Ad ministration form d oes not matc h the p hysic al hard ware, q uestion 
    marks (??) may display in the Code fields.
    nWhen a c irc uit p ac k in a slot d iffers from what has b een ad ministered on 
    the form, a “ #”  d isp lays b etween the “ Sfx”  and  “ Name”  field s.
    nFor Release 8r, the numb er of slot fields d isp layed  represents 
    ad ministrab le slots for the g iven c arrier typ e. For Release 8si 
    c onfig urations, all slot field s are d isp layed .
    Set System Maintenance Parameters
    If the system d oes not c ontain a TN778 Pac ket Control c irc uit p ac k, skip  this 
    sec tion and  p roc eed  to ‘‘
    Ad minister System Config urations (Release 8r)’’.
    1. Verify the terminal sc reen d isp lays: Command:
    2. Type change system-parameters maintenance 
    and press
     En te r. Verify 
    the sc reen d isp layed  is similar to Sc reen 3-5
    . The sc reen shows d efault 
    values and  the c ursor is p ositioned  on Product Identification:
     line. 
    						