Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-117 CAMA/E911 Installation 5 Screen 5-8. CAMA Numbering Format form 33. In the CAMA Numb ering - E911 Format sc reen (p ag e 1), in System CESID Default: field , enter your own system d efault and p ress En t e r. This is the numb er outp ulsed when the extension c od e is not found in the CAMA Numb ering tab le. See Sc reen 5-8 . 34. In the Ext Len , Ext Code , CESID , and Total Length field s, fill out to your own CAMA numb ering p lan and p ress En te r. Be sure to c over all extensions. 35. At the promp t, typ e change cor (the c lass of restriction (COR) to be changed) and press En t e r. Chang e all CORs that are defined for stations in ord er to remove any c alling p arty restric tions for 911 c alls. Page 1 of 3 CAMA NUMBERING - E911 FORMAT System CESID Default: 5241100______ Ext Ext Total Ext Ext Total Len Code CESID Length Len Code CESID Length 4_ 101__ 5381234_____ 7_ __ _____ __________ __ 4_ 1____ 555_________ 7_ __ _____ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __ __ _____ ____________ __ __ ______ ___________ __
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-118 Add IP Interface 5 Screen 5-9. Class of Restriction form (page 1) 36. On the Class of Restric tion sc reen (pag e 1), in the Calling Party Restriction: field , typ e none and p ress En te r. 37. Typ e Save Translation and press En te r. Add IP Interface NOTE: This sec tion c ontains p reliminary material for Med ia Proc essor features. DEFINITY ECS IP Solutions allows you to send voice and fax from the DEFINITY ECS through an Internet protocol (IP) network to other DEFINITY ECSs having this feature or to other H.323 V2 compliant endpoints. It is implemented using the TN802/B IP Interface, which is a Windows NT server residing on the IP Interface Assembly inside the DEFINITY ECS. The IP Interface is an assembly composed of a TN802B circuit board, a processor card, and DSP resource card. For ordering purposes, the assembly is identified as a J58890MA-1 L30, but for simplicity, we refer to it in this book as the TN802B IP Interface. The TN802B IP Interface operates in two modes: IP Trunk, available with Release 7 or later, and Media Processor (MedPro), available with Release 8. The IP Trunk mode is Internet Telephone Server—Enterprise (ITS-E) compatible, and the MedPro mode is H.323 V2 compatible. The TN802B IP Interface is backwards compatible and defaults to IP Trunk mode.To use it in MedPro mode, you activate it through administration on the change circuit-packs command. Page 1 of 3 CLASS OF RESTRICTION COR Number: 10 COR Description: supervisor FRL: 0 APLT? y Can Be Service Observed? n Calling Party Restriction: none Can Be A Service Observer? n Called Party Restriction: none Time of Day Chart: 1 Forced Entry of Account Codes? n Priority Queuing? n Direct Agent Calling? n Restriction Override: none Facility Access Trunk Test? n Restricted Call List? n Can Change Coverage? n Unrestricted Call List? Access to MCT? y Fully Restricted Service? n Category For MFC ANI: 7 Hear VDN of Origin Annc.? n Send ANI for MFE? n_ Add/Remove Agent Skills? n Hear System Music on Hold? y PASTE (Display PBX Data on Phone)? n Automatic Charge Display? n Can Be Picked Up By Directed Call Pickup? n Can Use Directed Call Pickup? n
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-119 Add IP Interface 5 For more information on the IP Interface capabilities and limitations, refer to the DEFINITY Enterprise Communications Server Release 8 Overview. The following sections describe the process for installing the TN802B IP Interface and cables and connecting it to a computer terminal, first for IP Trunk mode, then for MedPro mode. !WARNING: When c onnec ted remotely via p c ANYWHERE, only use the p c ANYWHERE Restart Host Computer button on the toolbar to restart Windows NT. Media Processor Mode To operate in MedPro mode, you must install the TN802B IP Interface and, if the system does not have one, you must also install and administer a TN799B C-LAN circuit pack. For C-LAN administration, refer to DEFINITY Enterprise Communications Server Administration for Network Connectivity. If you have existing TN802 IP Interface, however, you can upgrade them to TN802Bs by downloading the firmware onto the circuit pack (see ‘‘ Making a TN802 into a TN802B’’ on page 5-144). Prepare for Installation Have the following equipment on site before your shipment arrives: nAC power outlets for the modem and monitor. nThree unoccupied and adjoining port slots in the DEFINITY ECS for the TN802B IP Interface, if needed. The TN802B oc c up ies only one slot, b ut it need s the two slots to its left for c learanc e. nAn additional unoccupied port slot for the TN799B, if needed. If you have an existing TN799 circuit pack, replace it with the TN799B. nA 10 BaseT or 10/100 BaseT Ethernet connection into your local area network nTwo or more valid, unused IP addresses on your network that can be assigned to the IP Interface server. You also need the subnet mask and default gateway. nAn analog telephone line reserved (DID is okay) for the IP Interface diagnostic modem nA valid telephone number reserved for the IP Interface diagnostic modem
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-120 Add IP Interface 5 In addition if non-U.S. customer: nModem comparable to a U.S. Robotics Sportster Model USR 33.6 EXT. nCable from modem to TN802B external cable assembly. We recommend that you protect your cabinet with an uninterruptible power system (UPS). Check your Shipment When your DEFINITY Media Processor order arrives at your site, check the contents. 1. Insp ec t the ship p ing c arton for d amag e b efore op ening it. If the b ox is d amag ed , d o not op en it. Inform the ship p ing c omp any, and ask for instruc tions on filing a c laim. 2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king slip . Chec k the c ondition of eac h c omp onent, and note any d amag e or shortag es on the p ac king slip . The c arton should c ontain the following for eac h IP Interfac e ord ered : 3. Read and follow any d irec tions inserted into the p ac kag e b y the fac tory. Table 5-26. Required Hardware Equipment Description Quantity 108525528 TN799B C-LAN c irc uit p ac k. One TN799B may supp ort more than one TN802B, d ep end ing on the numb er of trunks.1 J58890MA-1 L30 TN802B IP Interfac e Assemb ly 1 or more H600-475 TN802B external c ab le assemb ly 1 259A c onnec tor 1 DW8 c ab le 1 407633999 U.S. Rob otic s Sp ortster external mod em, Mod el USR 33.6 EXT (U.S. customers only). Non-U.S. customers must p rovid e a mod em c omp arab le to this model . 1 601087091 20-ft DB-25 serial c ab le from modem to TN802B external c ab le assemb ly (U.S. c ustomers only). Non-U.S. c ustomers must p rovid e a serial c ab le.1
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-121 Add IP Interface 5 The TN802B external cable assembly is a bundle of cables with an amphenol connector at the end of the bundle and various PC-type connectors (VGA, Universal Serial Bus [USB], mouse, keyboard, Ethernet, modem, and COM2) at the ends of the individual cables. See Figure 5-44 . Look for the label where the bundle enters the amphenol connector. Figure 5-44. TN802B IP Interface External Cable Assembly Connect the Cables 1. Determine into whic h p ort slots you are p utting the TN799B C-LAN and TN802B IP Interfac e c irc uit p ac ks. NOTE: Make sure that at least 3 ad jac ent slots are free for the TN802B. From the rear of the cabinet: 2. If add ing a new TN799B, c onnec t the 259A c onnec tor to the b ac kp lane c onnec tor c orrespond ing to the TN799B slot. Figure Notes 1. Amp henol c onnec tor to c onnec tor c orresp ond ing to TN802B slot 2. To VGA monitor 3. To USB (not used ) 4. To keyb oard5. To mouse 6. To ethernet 7. 25-p in male c onnec tor to mod em 8. 25-p in male c onnec tor to COM2 cbdfocto AWF 122398 2 1 345678
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-122 Add IP Interface 5 3. If add ing a new TN799B, c onnec t one end of the DW8 c able to the 259A c onnec tor. Connec t the other end to the c ustomer’s network. 4. Connec t the amp henol c onnec tor on the external c ab le assemb ly to the b ac kp lane c onnec tor c orresp ond ing to the TN802B slot (the hig hest numb ered c onnec tor of the 3 slots req uired ) Connect the Modem NOTE: These instruc tions are for c onnec ting the U.S. Rob otic s mod em sup p lied to U.S. c ustomers only. If using a d ifferent mod em, follow the manufac turer’s instruc tions on c onnec ting the mod em. 1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the TN802B external c ab le assembly. NOTE: Chec k the lab els near the c onnec tors; the MODEM and COM2 c onnec tors look the same. 2. Connec t an analog telephone line to the left most analog -line p ort on the mod em as shown in Fig ure 5-45 . 3. Make sure that the mod em’s DIP switc hes are set as shown in Fi g u re 5 - 4 5 . 4. Plug the mod em into an AC p ower outlet. 5. Turn on the mod em using the switc h on the front of the mod em. Figure 5-45. External Modem Connections for U.S. Robotics Modem Figure Notes 1. Connec t analog line here. 2. DIP switch 5 must b e up .3. Connec t MODEM c onnec tor here. 4. Connec t p ower c onnec tor here. 12345678 modfrobo KLC 030499 234 1
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-123 Add IP Interface 5 Connect the Ethernet 1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B external c ab le assemb ly. Upgrading to TN802B If you have a TN802 IP Interface, you must either install a TN802B or upgrade the existing circuit pack to operate in MedPro mode. Refer to ‘‘ Making a TN802 into a TN802B’’ on page 5-144. To operate in the MedPro mode, you need to upgrade the switch to Release 8 or later. Install the Circuit Packs !CAUTION: When ad d ing or rep lac ing any hard ware, b e sure to g round yourself ag ainst elec trostatic d isc harge (ESD) b y wearing a g rounded wrist strap . NOTE: The TN799B and TN802B c irc uit p ac ks are hot-swap p ab le, so you d o not need to p ower down the c arrier to install them. If you need to remove the TN802B IP Interfac e from the c arrier at a later time, shut d own Wind ows NT first b y p ressing the rec essed reset b utton on the fac ep late (see Fig ure 5-4 6 ) of the TN802B IP Interfac e until the LCD shows a flashing MSHUT * . When the flashing stop s and the asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit pac k.
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-124 Add IP Interface 5 Figure 5-46. TN802B IP Interface faceplate 1. Insert the TN799B c irc uit p ac k into the p ort slot id entified earlier. NOTE: If rep lac ing the existing TN799 c irc uit p ac k, remove it first and rep lac e it with the new one. To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late until the latc h reac hes the bottom rail of the c arrier. Then c lose the latc h until it is fully eng ag ed . Figure Notes 1. LCD display 2. Reset b utton (rec essed ) 3. Red b oard status LED4. PCMCIA c ard slot 5. Yellow PCMCIA disk-in-use LED 1 2 3 4 5 fpdfmapd KLC 030899
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-125 Add IP Interface 5 2. Insert the TN802B IP Interfac e into the rig ht most of the three slots you reserved for it (see Fig ure 5-47 ) and seat it p rop erly. When you p lug in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot and the LCD read s PC Boot . After ab out 3 to 4 minutes, it c hang es to MEDPRO * . NOTE: If this is an initial installation, the TN802B IP Interfac e need s to b e administered first (see ‘‘ Ad minister the IP Interfac e’’ on p age 5-126). Figure 5-47. J58890MA-1 L30 IP Interface Assembly Administer the TN799B C-LAN Refer to the DEFINITY Enterprise Communications Server Administration for Network Connectivity . 456 789 1 0 1 11 21 3 1 41 51 6 indfmapd KLC 031299
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-126 Add IP Interface 5 Administer the IP Interface Administration is usually done remotely; call your service representative to start the process. Administration Steps NOTE: Refer to the DEFINITY Enterp rise Communic ations Server Ad ministration for Network Connec tivity for Release 8 for sp ec ific information. 1. Login as craft 2. Type change node-names and p ress En te r 3. On sc reen 2, typ e in the node name and IP add ress for the TN802B. 4. Type change circuit-pack and p ress En te r. change node-names Page 2 of 6 NODE NAMES Name IP Address Name IP Address clan-a1 192.168.1 .31 . . . clan-b1 192.168.2 .31 . . . default 0 .0 .0 .0 . . . med-a1 192.168.1 .81 . . . . . . . . . . . . . . . . . . . . .