Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-117 CAMA/E911 Installation 
    5
    Screen 5-8. CAMA Numbering Format form
    33. In the CAMA Numb ering  - E911 Format sc reen (p ag e 1), in System 
    CESID Default:
     field , enter your own system d efault and p ress 
    En t e r. 
    This is the numb er outp ulsed  when the extension c od e is not found in the 
    CAMA Numb ering  tab le. See Sc reen 5-8
    .
    34. In the Ext Len
    , Ext Code
    , CESID
    , and  Total Length
     field s, fill out to 
    your own CAMA numb ering  p lan and  p ress 
    En te r. Be sure to c over all 
    extensions.
    35. At the promp t, typ e change cor 
     
    (the c lass of restriction (COR) 
    to be changed) and press 
    En t e r. Chang e all CORs that are defined  for 
    stations in ord er to remove any c alling  p arty restric tions for 911 c alls.
                                                                         Page 1 of 3
                             CAMA NUMBERING - E911 FORMAT
    System CESID Default: 5241100______
    Ext  Ext                   Total         Ext  Ext                   Total
    Len Code      CESID      Length         Len  Code      CESID      Length
    4_  101__  5381234_____    7_             __  _____  __________     __
    4_  1____  555_________    7_             __  _____  ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __
    __  _____  ____________    __             __  ______ ___________    __ 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-118 Add IP Interface 
    5
    Screen 5-9. Class of Restriction form (page 1)
    36. On the Class of Restric tion sc reen (pag e 1), in the Calling Party 
    Restriction:
     field , typ e none 
    and  p ress 
    En te r.
    37. Typ e Save Translation
     and press 
    En te r.
    Add IP Interface
    NOTE:
    This sec tion c ontains p reliminary material for Med ia Proc essor features.
    DEFINITY ECS IP Solutions allows you to send voice and fax from the DEFINITY 
    ECS through an Internet protocol (IP) network to other DEFINITY ECSs having 
    this feature or to other H.323 V2 compliant endpoints. It is implemented using the 
    TN802/B IP Interface, which is a Windows NT server residing on the IP Interface 
    Assembly inside the DEFINITY ECS.
    The IP Interface is an assembly composed of a TN802B circuit board, a processor 
    card, and DSP resource card. For ordering purposes, the assembly is identified as 
    a J58890MA-1 L30, but for simplicity, we refer to it in this book as the TN802B IP 
    Interface.
    The TN802B IP Interface operates in two modes: IP Trunk, available with Release 
    7 or later, and Media Processor (MedPro), available with Release 8. The IP Trunk 
    mode is Internet Telephone Server—Enterprise (ITS-E) compatible, and the 
    MedPro mode is H.323 V2 compatible. The TN802B IP Interface is backwards 
    compatible and defaults to IP Trunk mode.To use it in MedPro mode, you activate 
    it through administration on the change circuit-packs command.
     Page 1 of 3
    CLASS OF RESTRICTION
                   COR Number: 10
              COR Description: supervisor
                          FRL: 0 APLT? y
      Can Be Service Observed? n           Calling Party Restriction: none
    Can Be A Service Observer? n Called Party Restriction: none
    Time of Day Chart: 1  Forced Entry of Account Codes? n
             Priority Queuing? n                Direct Agent Calling? n
         Restriction Override: none Facility Access Trunk Test? n
         Restricted Call List? n Can Change Coverage? n
    Unrestricted Call List?
                Access to MCT? y  Fully Restricted Service? n
    Category For MFC ANI:   7  Hear VDN of Origin Annc.? n
             Send ANI for MFE? n_  Add/Remove Agent Skills? n
    Hear System Music on Hold? y PASTE (Display PBX Data on Phone)? n
    Automatic Charge Display? n 
    Can Be Picked Up By Directed Call Pickup? n
    Can Use Directed Call Pickup? n 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-119 Add IP Interface 
    5
    For more information on the IP Interface capabilities and limitations, refer to the 
    DEFINITY Enterprise Communications Server Release 8 Overview.
    The following sections describe the process for installing the TN802B IP Interface 
    and cables and connecting it to a computer terminal, first for IP Trunk mode, then 
    for MedPro mode.
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer button on the toolbar to restart Windows NT.
    Media Processor Mode
    To operate in MedPro mode, you must install the TN802B IP Interface and, if the 
    system does not have one, you must also install and administer a TN799B C-LAN 
    circuit pack. For C-LAN administration, refer to 
    DEFINITY Enterprise 
    Communications Server Administration for Network Connectivity.
    If you have existing TN802 IP Interface, however, you can upgrade them to 
    TN802Bs by downloading the firmware onto the circuit pack (see ‘‘
    Making a 
    TN802 into a TN802B’’ on page 5-144). 
    Prepare for Installation
    Have the following equipment on site before your shipment arrives:
    nAC power outlets for the modem and monitor.
    nThree unoccupied and adjoining port slots in the DEFINITY ECS for the 
    TN802B IP Interface, if needed.
    The TN802B oc c up ies only one slot, b ut it need s the two slots to its left for 
    c learanc e.
    nAn additional unoccupied port slot for the TN799B, if needed. If you have 
    an existing TN799 circuit pack, replace it with the TN799B.
    nA 10 BaseT or 10/100 BaseT Ethernet connection into your local area 
    network
    nTwo or more valid, unused IP addresses on your network that can be 
    assigned to the IP Interface server. You also need the subnet mask and 
    default gateway. 
    nAn analog telephone line reserved (DID is okay) for the IP Interface 
    diagnostic modem 
    nA valid telephone number reserved for the IP Interface diagnostic modem  
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-120 Add IP Interface 
    5
    In addition if non-U.S. customer:
    nModem comparable to a U.S. Robotics Sportster Model USR 33.6 EXT. 
    nCable from modem to TN802B external cable assembly.
    We recommend that you protect your cabinet with an uninterruptible power 
    system (UPS).
    Check your Shipment
    When your DEFINITY Media Processor order arrives at your site, check the 
    contents.
    1. Insp ec t the ship p ing  c arton for d amag e b efore op ening  it. If the b ox is 
    d amag ed , d o not op en it. Inform the ship p ing  c omp any, and  ask for 
    instruc tions on filing a c laim.
    2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king  slip . 
    Chec k the c ondition of eac h c omp onent, and note any d amag e or 
    shortag es on the p ac king  slip . The c arton should  c ontain the following  for 
    eac h IP Interfac e ord ered :
    3. Read  and  follow any d irec tions inserted  into the p ac kag e b y the fac tory.
    Table 5-26. Required Hardware
    Equipment Description Quantity
    108525528 TN799B C-LAN c irc uit p ac k. One 
    TN799B may supp ort more than one 
    TN802B, d ep end ing  on the numb er of 
    trunks.1
    J58890MA-1 L30 TN802B IP Interfac e Assemb ly
    1 or more
    H600-475 TN802B external c ab le assemb ly 1
    259A c onnec tor 1
    DW8 c ab le 1
    407633999 U.S. Rob otic s Sp ortster external 
    mod em, Mod el USR 33.6 EXT (U.S. 
    customers only). Non-U.S. customers 
    must p rovid e a mod em c omp arab le to 
    this model
    . 1
    601087091 20-ft DB-25 serial c ab le from modem 
    to TN802B external c ab le assemb ly 
    (U.S. c ustomers only). Non-U.S. 
    c ustomers must p rovid e a serial c ab le.1 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-121 Add IP Interface 
    5
    The TN802B external cable assembly is a bundle of cables with an amphenol 
    connector at the end of the bundle and various PC-type connectors (VGA, 
    Universal Serial Bus [USB], mouse, keyboard, Ethernet, modem, and COM2) at 
    the ends of the individual cables. See Figure 5-44
    . Look for the label where the 
    bundle enters the amphenol connector. 
    Figure 5-44. TN802B IP Interface External Cable Assembly
    Connect the Cables
    1. Determine into whic h p ort slots you are p utting the TN799B C-LAN and  
    TN802B IP Interfac e c irc uit p ac ks.
    NOTE:
    Make sure that at least 3 ad jac ent slots are free for the TN802B.
    From the rear of the cabinet:
    2. If add ing  a new TN799B, c onnec t the 259A c onnec tor to the b ac kp lane 
    c onnec tor c orrespond ing  to the TN799B slot. Figure Notes
    1. Amp henol c onnec tor to c onnec tor 
    c orresp ond ing to TN802B slot
    2. To VGA monitor
    3. To USB (not used )
    4. To keyb oard5. To mouse
    6. To ethernet
    7. 25-p in male c onnec tor to mod em
    8. 25-p in male c onnec tor to COM2 
    cbdfocto AWF 122398
    2
    1
    345678 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-122 Add IP Interface 
    5
    3. If add ing  a new TN799B, c onnec t one end  of the DW8 c able to the 259A 
    c onnec tor. Connec t the other end  to the c ustomer’s network.
    4. Connec t the amp henol c onnec tor on the external c ab le assemb ly to the 
    b ac kp lane c onnec tor c orresp ond ing  to the TN802B slot (the hig hest 
    numb ered c onnec tor of the 3 slots req uired )
    Connect the Modem
    NOTE:
    These instruc tions are for c onnec ting  the U.S. Rob otic s mod em 
    sup p lied  to U.S. c ustomers only. If using  a d ifferent mod em, follow 
    the manufac turer’s instruc tions on c onnec ting  the mod em.
    1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the 
    TN802B external c ab le assembly. 
    NOTE:
    Chec k the lab els near the c onnec tors; the MODEM and  COM2 
    c onnec tors look the same.
    2. Connec t an analog  telephone line to the left most analog -line p ort on the 
    mod em as shown in Fig ure 5-45
    . 
    3. Make sure that the mod em’s DIP switc hes are set as shown in 
    Fi g u re  5 - 4 5
    . 
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the mod em using  the switc h on the front of the mod em.
    Figure 5-45. External Modem Connections for U.S. Robotics Modem Figure Notes
    1. Connec t analog  line here.
    2. DIP switch 5 must b e up .3. Connec t MODEM c onnec tor here.
    4. Connec t p ower c onnec tor here.
    12345678
    modfrobo KLC 030499
    234
    1 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-123 Add IP Interface 
    5
    Connect the Ethernet
    1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B 
    external c ab le assemb ly.
    Upgrading to TN802B
    If you have a TN802 IP Interface, you must either install a TN802B or upgrade the 
    existing circuit pack to operate in MedPro mode. Refer to ‘‘
    Making a TN802 into a 
    TN802B’’ on page 5-144. To operate in the MedPro mode, you need to upgrade 
    the switch to Release 8 or later.
    Install the Circuit Packs
    !CAUTION:
    When ad d ing  or rep lac ing any hard ware, b e sure to g round  yourself 
    ag ainst elec trostatic  d isc harge (ESD) b y wearing  a g rounded  wrist 
    strap .
    NOTE:
    The TN799B and  TN802B c irc uit p ac ks are hot-swap p ab le, so you 
    d o not need  to p ower down the c arrier to install them.
    If you need  to remove the TN802B IP Interfac e from the c arrier at a 
    later time, shut d own Wind ows NT first b y p ressing  the rec essed  
    reset b utton on the fac ep late (see Fig ure 5-4 6
    ) of the TN802B IP 
    Interfac e until the LCD shows a flashing  MSHUT *
    . When the flashing  
    stop s and  the asterisk d isap p ears (ab out 2 min), it is safe to remove 
    the c irc uit pac k. 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-124 Add IP Interface 
    5
    Figure 5-46. TN802B IP Interface faceplate
    1. Insert the TN799B c irc uit p ac k into the p ort slot id entified  earlier.
    NOTE:
    If rep lac ing  the existing  TN799 c irc uit p ac k, remove it first and 
    rep lac e it with the new one.
    To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the 
    fac ep late until the latc h reac hes the bottom rail of the c arrier. Then 
    c lose the latc h until it is fully eng ag ed . Figure Notes
    1. LCD display
    2. Reset b utton (rec essed )
    3. Red  b oard  status LED4. PCMCIA c ard  slot
    5. Yellow PCMCIA disk-in-use LED
    1
    2
    3
    4
    5
    fpdfmapd KLC 030899 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-125 Add IP Interface 
    5
    2. Insert the TN802B IP Interfac e into the rig ht most of the three slots you 
    reserved  for it (see Fig ure 5-47
    ) and  seat it p rop erly.
    When you p lug  in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot 
    and  the LCD read s PC Boot
    . After ab out 3 to 4 minutes, it c hang es to 
    MEDPRO *
    . 
    NOTE:
    If this is an initial installation, the TN802B IP Interfac e need s to b e 
    administered first (see ‘‘
    Ad minister the IP Interfac e’’ on p age 5-126). 
    Figure 5-47. J58890MA-1 L30
     IP Interface Assembly
    Administer the TN799B C-LAN
    Refer to the DEFINITY Enterprise Communications Server Administration for 
    Network Connectivity
    .
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    indfmapd KLC 031299 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-126 Add IP Interface 
    5
    Administer the IP Interface
    Administration is usually done remotely; call your service representative to start 
    the process.
    Administration Steps
    NOTE:
    Refer to the DEFINITY Enterp rise Communic ations Server 
    Ad ministration for Network Connec tivity for Release 8 for sp ec ific  
    information.
    1. Login as craft
    2. Type change node-names
     and  p ress 
    En te r 
    3. On sc reen 2, typ e in the node name and  IP add ress for the TN802B.
    4. Type change circuit-pack
     and  p ress 
    En te r.
    change node-names                                               Page   2 of   6 
                                      NODE NAMES                                    
        Name             IP Address           Name              IP Address
    clan-a1             192.168.1 .31  .   .   . 
    clan-b1             192.168.2 .31  .   .   . 
    default             0  .0  .0  .0  .   .   . 
    med-a1              192.168.1 .81  .   .   . 
    .   .   .  .   .   .   
    .   .   .  .   .   .   
    .   .   .  .   .   .    
    						
    All Lucent Technologies manuals Comments (0)