    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 467
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-147 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    nCord DW8A-DE
    4-p air mod ular c ord  to alarm c ontac ts
    nDS1 circuit pack
    The b asic  ICSU req uires a TN474E or TN777D or later suffix. The 
    enhanc ed  integ rated  c hannel servic e unit req uires a TN474F or TN777E or 
    later suffix.
    Installing the 120A CSU
    See Figure 5-52. 
    Figure 5-52. 120A Channel Service Unit Module
    !CAUTION:
    Do not p lug  the 120A into any c irc uit p ac k other than a TN474F or TN777E 
    or later release/vintag e. Do not c onnec t the 120A to any interfac e other than 
    a network smart jac k.
    Be sure the DS1 c irc uit p ac k is set for 24-c hannel op eration (1.544 Mbp s). 
    The 120A d oes not op erate with the 32-c hannel interfac e. A switc h on the 
    c irc uit p ac k or ad ministration sets this op tion. 
    1. Rear of c arrier c ontaining  DS1 c irc uit p ac k
    2. 120A CSU
    3. 4-p air c ord  to network interfac e (H600-383)4. DW8A-DE 4-p air c ord  to alarm c ontac ts (op tional)
    5. To 25-p air c onnec tor on rear of c arrier c ontaining  
    DS1 circ uit pac k
    16 17 18 19 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01AU X
    icsupic RBP 032896 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-148 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    !CAUTION:
    Always wear an anti-static  wrist strap when installing  a 120A mod ule. Do 
    not touc h the external alarm c able when it is c onnec ted  to the 120A. Static  
    d isc harg e c an d amag e c onnec tor terminals and  relays. 
    1. Unp lug  the DS1 c irc uit p ac k from its slot.
    2. Install a 4C retainer in the 50-p in p lug  assoc iated  with the DS1 c irc uit p ac k 
    slot.
    3.Plug  the 120A’s 25-p air c onnec tor d irec tly into the p lug  assoc iated  with 
    the DS1 c irc uit p ac k slot. 
    4. Sec ure the 4C retainer around  the 120A.
    5. Attac h the sup p lied  H600-383 c able to the 120A and to the network smart 
    jac k. 
    This c ab le is d irec tional. To determine the end  that c onnec ts to the 120A, 
    p erform a c ontinuity test b etween pins 3 and  7. The end  with this 
    c ontinuity is the 120A end . The shield  is g round ed  only at the 120A end .
     Use the c ab le p rovid ed . If c ab ling  other than that p rovided  with the 120A 
    is used , ob serve the following  g uid elines:
    nUse 24-g aug e wire that p rovid es ind ividually shield ed , twisted  p airs 
    for transmit and  rec eive sig nals. Use the c ab le b etween the 
    network interfac e and  the 120A. Ground  the shield s of this c able 
    only at the 120A end to avoid  g round  loop s.
    nCab ling  b etween the network interfac e and  120A c an have no 
    bridge taps.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, maintain a 100-p air sep aration 
    b etween the rec eive and  transmit twisted  p airs.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, allow no more than 2 c ross 
    c onnec ts to 110-typ e c ross c onnec t bloc ks.
    nNever use quad  c ab le (untwisted  two pair telep hone c ab le) in a 
    DS1 line.
    nAvoid  mixing  wires of d ifferent g aug es in a DS1 line.
    6. If using  external alarm eq uip ment, attac h the sup p lied  DW8 c ab le to the 
    120A and  the external eq uip ment. The maximum length of this c ab le 
    d ep end s on the alarm eq uip ment.
    7. If a TN474F is used , make sure the c irc uit p ac k is set for 24-c hannel 
    op eration. Set the switc h on the c irc uit p ac k as shown in Fig ure 5-52
    .
    8. From the DS1 c irc uit-p ac k form of the system ad ministration c onsole, set 
    the line c omp ensation field  to 0-133 feet (40.6 m). 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-149 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    9. Reset the 120A b y reseating  the DS1 c irc uit p ac k.
    When you reinsert the DS1 c irc uit p ac k after installing  a 120A CSU the 
    120A resets. The DS1 c irc uit p ac k initializes and  tests the 120A. When 
    initialization and  testing  is c omp lete, the g reen LED goes off. If the RED 
    indic ator is OFF after the test, the ICSU is working .
    10. If the c irc uits d o not p ass the self test, troub leshoot the 120A as instruc ted  
    in Integ rated  CSU Mod ule Installation and  Op eration, 555-230-193.
    Table 5-28
     provides the H600-383 cable pinouts. Table 5-29 provides the cable 
    lengths for each cable group number.
    Table 5-28. H600-383 cable Pin Assignments
    Pin ColorChannel Service 
    Unit DesignationNetwork 
    Designation Function
    1BK Line in 0 R1 RCV
    2 Y Line in 1 T1
    3 Shield
    4 R Line out 0 R XMT
    5 G Line out 1 T
    7 Shield
    7 Not assigned
    8 Not assigned
    Table 5-29. H600-383 cable Lengths by Group Number
    Group Length Group Length
    1 25 ft (7.7 m) 5 125 ft (38.1 m)
    2 50 ft (15.2 m) 7 200 ft (71 m)
    3 75 ft (22.9 m) 7 400 ft (122 m)
    4 100 ft (30.5 m) 8 750 ft (198.1 m) 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-150 Installing a 3150/3170 Channel Service Unit 
    5
    Installing a 3150/3170 
    Channel Service Unit
    1. Install the CSU as shown in Figure 5-13. For some installations (such as a 
    DS1 c onverter), use a Y-c ab le to c onnec t the DEFINITY System to the 
    q uad  c ab le. Tab le 5-13
     shows the Y-c ab le leng ths. Be sure to lab el all 
    cables. 
    Figure 5-13
     shows a typ ic al c onnec tion from the H600-348 Quad  c ab le to 
    the CSU, through the H600-307 network c ab le, and  to the network 
    interfac e throug h the smart jac ks. The q uad  c ab le p rovid es up  to four 
    c onnec tions using a 15-pin c onnec tor that p lug s into the DTE jac k on eac h 
    CSU. The H600-348 q uad  c ab le may req uire an ad ap ter c ab le.
    Figure 5-53. 3150/3170 Channel Service Unit Connections 1. H600-348 q uad  c ab le
    2.15-p in male “ D”  c onnec tors (to DTE jac ks on CSU)
    3. Channel servic e unit (CSU)
    4. H600-383 c ab le (RJ-48C to RJ-48C)
    5. Network interfac e6. Smart jac k (if p rovid ed )
    7. Cab le A
    8. Cab le B
    9. Cab le C
    10. Cab le D
    3150csu RBP 062696
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PO RT C OM PORT M OD EM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-151 Installing a 3150/3170 Channel Service Unit 
    5
    Figure 5-54. DS1 Converter Connections Using Double-Headed cable
    1. Port c arrier
    2. DS1 c onverter c onnec tor
    3. 50-p air female c onnec tor to DEFINITY 
    EC S
    4.14-in. (35.57 c m) “Y” cable5. 50-Pin Male/50-p in female 
    double-headed  connector cable
    6. Quad  c ab le (with 50-p in male c onnec tor) 
    c onnec ts to the c hannel servic e unit.
    Table 5-30. “Y” cable Lengths (DS1 converter Only)
    Length 
    (in/cm) Description Comcode
    14/35.5  TN1754 to adjac ent exp ansion interfac e c irc uit p ac k or 
    TN573B switc h nod e interfac e c irc uit p ac k in same c arrier 847245750
    70/177.8 TN1754 to exp ansion interfac e c irc uit p ac k or switc h nod e 
    interfac e in another c arrier847245778
    14/35.5 TN1754 to fib er op tic  transc eiver (DC-p owered  c ab inets only). 
    This c ab le is for interc ab inet c ab ling only.847245777
    14/35.5 TN1754 to adjac ent TN570/B/C exp ansion interfac e c irc uit 
    pack 847747741
    cydf010 RPY 090597
    20 1916 17 18 15 14 13 12 1110
    09 08 07 06 05 04 03 02 01 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-152 Connector and Cable Diagrams (Pinout Charts) 
    5
    Connector and Cable Diagrams 
    (Pinout Charts)
    See Table 5-31 for lead designations. The circuit packs and auxiliary equipment 
    are classified as shown in the tables at the end of this chapter.
    `
    Table 5-31. Lead and Color Designations 
    Cross-Connect Pin  Color Amphenol Pin  Backplane Pin
    1W-BL26 102
    2 BL-W 01 002
    3W-O27 103
    4O-W02 003
    5W-G28 104
    6G-W03 004
    7W-BR29 105
    8BR-W04 005
    9W-SL30 106
    10 SL-W 05 006
    11 R-BL 31 107
    12 BL-R 06 007
    13 R-O 32 108
    14 O-R 07 008
    15 R-G 33 109
    16 G-R 08 009
    17 R-BR 34 110
    18 BR-R 09 010
    19 R-SL 35 111
    20 SL-R 10 011
    21 BK-BL 36 112
    22 BL-BK 11 012
    23 BK-O 37 113
    24 O-BK 12 013
    25 BK-G 38 302
    26 G-BK 13 202
    27 BK-BR 39 303
    28 BR-BK 14 203
    29 BK-SL 40 304
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-153 Connector and Cable Diagrams (Pinout Charts) 
    5
    30 SL-BK 15 204
    31 Y-BL 41 305
    32 BL-Y 16 205
    33 Y-O 42 306
    34 O-Y 17 206
    35 Y-G 43 307
    36 G-Y 18 207
    37 Y-BR 44 308
    38 BR-Y 19 208
    39 Y- SL 45 3 09
    40 SL-Y 20 209
    41 V-BL 46 310
    42 BL-V 21 210
    43 V-O 47 311
    44 O-V 22 211
    45 V-G 48 312
    46 G-V 23 212
    47 V-BR 49 313
    48 BR-V 24 213
    49 V- SL 50 3 00
    50 SL-V 25 200
    Table 5-31. Lead and Color Designations  — Continued
    Cross-Connect Pin  Color Amphenol Pin  Backplane Pin
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-154 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-32 shows the pinouts for the TN2185 ISDN-BRI 4-wire S Interface. 
    Table 5-32. TN2185 ISDNBRI — 4-Wire S Interface Pinout
    Port Signal Cross-Connect Pin  Color Amphenol  Pin  Backplane  Pin
    1 TXT.1 1 W-BL 26 102
    TXR.1 2 BL-W 01 002
    PXT.1 3 W-O 27 103
    PXR.1 4 O-W 02 003
    2 TXT.2 5 W-G 28 104
    TXR.2 6 G-W 03 004
    PXT. 2 7 W-B R 2 9 1 0 5
    PXR. 2 8 BR- W 0 4 0 0 5
    3 TXT.3 9 W-SL 30 106
    TXR.3 10 SL-W 05 006
    PXT.3 11 R-BL 31 107
    PXR.3 12 BL-R 06 007
    4 TXT.4 13 R-O 32 108
    TXR.4 14 O-R 07 008
    PXT. 4 1 5 R-G 3 3 1 0 9
    PXR. 4 1 6 G - R 0 8 0 0 9
    5 TXT.5 17 R-BR 34 110
    TXR.5 18 BR-R 09 010
    PXT. 5 1 9 R- SL 3 5 1 1 1
    PXR. 5 2 0 SL - R 1 0 0 1 1
    6 TXT.6 21 BK-BL 36 112
    TXR.6 22 BL-BK 11 012
    PXT.6 23 BK-O 37 113
    PXR.6 24 O-BK 12 013
    7 TXT.7 25 BK-G 38 302
    TXR.7 26 G-BK 13 202
    PXT. 7 2 7 B K- B R 3 9 3 0 3
    PXR. 7 2 8 B R- B K 1 4 2 0 3
    8 TXT.8 29 BK-SL 40 304
    TXR.8 30 SL-BK 15 204
    PXT. 8 3 1 Y- BL 4 1 3 0 5
    PXR.8 32 BL-Y 16 205 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-155 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-33 shows the pinouts for the TN2198 ISDN-BRI 2-wire U Interface.
    * 
    Pins 25 and 50 are grounded by the backplane.
    Table 5-33. TN2198 ISDN-BRI — 2-Wire U Interface Pinout
    Port Signal Cross-Connect 
    Pin ColorAmphenol 
    Pin Backplane Pin
    1T.1 1 W-BL 26 102
    R.1 2 BL- W 0 1 00 2
    2T.2 3 W-O 27 103
    R.2 4 O - W 0 2 00 3
    3T.3 5 W-G 28 104
    R.3 6 G - W 0 3 00 4
    4T.4 7 W-BR 29 105
    R.4 8 BR- W 0 4 00 5
    5T.5 9 W-SL 30 106
    R.5 10 SL- W 0 5 00 6
    6 T.6 11 R-BL 31 107
    R.6 12 BL-R 06 007
    7T.7 13 R-O 32 108
    R.7 14 O - R 0 7 00 8
    8T.8 15 R-G 33 109
    R.8 16 G - R 0 8 00 9
    9 T.9 17 R-BR 34 110
    R.918BR-R09 010
    10 T.10 19 R-SL 35 111
    R.10 20 SL-R 10 011
    11 T.11 21 BK-BL 36 112
    R.11 22 BL-BK 11 012
    12 T.12 23 BK-O 37 113
    R.12 24 O-BK 12 013 
    						
    							DEFINITY ECS Release 8.2 Installation and Test
    for Multi-Carrier Cabinets  555-233-114  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-156 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-34. Port Circuit Pack Lead Designations 
    Cross- 
    Connect 
    PinTN742/B
    TN747B
    TN753 
    TN769 
    TN2147 
    TN465TN754
    TN726TN760/B
    TN760C 
    TN760D
    TN2209 TN762/BTN763 
    TN763B
    TN763C TN735TN767B
    TN464ETN746/B 
    TN2183
    TN793
    TN2793 TN2224
    1 T.1 T.1 T.1 T.1 T.1 C_5 T.1 T.1
    2 R.1 R.1 R.1 R.1 R.1 R.1 R.1
    3 TXT. 1 T1 . 1 TXT. 1 SZ . 1 B T. 1 C _EN A B T. 2 T. 2
    4 TXR.1 R1.1 TXR.1 SZ1.1 BR.1 R.2 R.2
    5 PXT. 1 E. 1 PXT. 1 S.1 L T.1 C_SYNC* T.3 T.3
    6 PXR.1 M.1 PXR.1 S1.1 LR.1 R.3 R.3
    7 T.2 T.2 T.2 T.2 T.2 C2D-DATA T.4 T.4
    8 R.2 R.2 R.2 R.2 R.2 RDATA* R.4 R.4
    9 TXT. 2 T1 . 2 TXT. 2 SZ . 2 B T. 2 TD A TA * T. 5
    10 TXR.2 R1.2 TXR.2 SZ1 .2 B R.2 TRSYSN C R.5
    11 PXT.2 E.2 PXT.2 S.2 LT.2 GRD T.6
    12 PXR.2 M.2 PXR.2 S1.2 L R. 2 SC L K* R.6
    13 T.3 T.3 T.3 T.3 T.3 T.7
    14 R.3 R.3 R.3 R.3 R.3 R.7
    1 5 TXT. 3 T1 . 3 TXT. 3 SZ . 3 B T. 3 T. 8
    16 TXR.3 R1.3 TXR.3 SZ1 .3 B R.3 PA H ER* R.8
    1 7 PXT. 3 E. 3 PXT. 3 S. 3 L T. 3 T. 5 T. 9
    18 PXR.3 M.3 PXR.3 S1.3 LR.3 C_48V R.5 R.9
    19 T.4 T.4 T.4 T.4 T.4 T.6 T.10
    20 R.4 R.4 R.4 R.4 R.4 R.6 R.10
    2 1 TXT. 4 T1 . 4 TXT. 4 SZ . 4 B T. 4 C _P2 SC L K T. 7 T. 1 1
    22 TXR.4 R1.4 TXR.4 SZ1.4 BR.4 LI
     (RX) R.7 R.11
    2 3 PXT. 4 E. 4 PXT. 4 S. 4 L T. 4 L O *  ( TX) T. 8 T. 1 2
    24 PXR.4 M.4 PX4.4 S1.4 LR.4 LBACK1 R.8 R.12
    2 5 T. 5 T. 5 T. 5 T. 5 T. 5 G N D T. 9 T. 1 3
    26 R.5 R.5 R.5 R.5 R.5 C _5V R.9 R.13
    2 7 TXT. 5 T1 . 5 TXT. 5 SZ . 5 B T. 5 T. 1 0 T. 1 4
    28 TXR.5 R1.5 TXR.5 SZ1.5 BR.5 R.10 R.14
    2 9 PXT. 5 E. 5 PXT. 5 S. 5 L T. 5 T. 1 1 T. 1 5
    30 PXR.5 M.5 PXR.5 S1.5 L R. 5 C _RST R.11 R.15
    31 T.6 T.6 T.6 T.6 T.6 T.12 T.16
    32 R.6 R.6 R.6 R.6 R.6 R.12 R.16
    3 3 TXT. 6 T1 . 6 TXT. 6 SZ . 6 B T. 6 RD A TA T. 1 7
    34 TXR.6 R1.6 TXR.6 SZ1 .6 B R.6 TD A TA R.17
    3 5 PXT. 6 E. 6 PXT. 6 S. 6 L T. 6 TRSYN C T. 1 8
    36 PXR.6 M.6 PXR.6 S1.6 L R. 6 GRD R.18
    37 T.7 T.7 T.7 T.7 T.7 SCLK T.19
    38 R.7 R.7 R.7 R.7 R.7 R.19
    Continued on next page 
    						