    Section 8-3 - Software Loading Procedure 8 - 125
    8-3-5-3               Printer setting Back-up  (cont’d)
    6.)  Select removable disk or other media.
    7.)  Click the “Save” to write the printer configuration. Figure 8-172   Printer set backup
    Figure 8-173   Printer set backup 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1 LOGIQ™ P5 SERVICE MANUAL  
    8 - 126 Section 8-3 - Software Loading Procedure
    8-3-5-3               Printer setting Back-up  (cont’d)
    8.) Click the “OK” until all  printer windows are closed.
    9.) If Sony D895 is used, repeat the step1  to setp4 and write down the Orientation set.
    Figure 8-174   Printer set backup
    Figure 8-175   Printer set backup 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1LOGIQ™ P5 SERVICE MANUAL 
    Section 8-3 - Software Loading Procedure 8 - 127
    8-3-5-3               Printer setting Back-up  (cont’d)
    10.)  Click the “Advanced”, then writhe down the Paper size and scaling parameters.
    11.) Click “Properties” of the “Density Adjust”. Figure 8-176   Printer set backup
    ParametersDescriptions
    Orientation
    Portrait or Landscape
    Paper size Paper size
    Scaling Rate of length and width
    Table 8-52 Parameters
    Figure 8-177   Printer set backup 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1 LOGIQ™ P5 SERVICE MANUAL  
    8 - 128 Section 8-3 - Software Loading Procedure
    8-3-5-3               Printer setting Back-up  (cont’d)
    12.) Click “Save” -> select a remo vable disk or other media -> save the printer configuration.
    13.) Click the “OK” until all  printer windows are closed.
    14.) If the printer does not support the configuration  save or write option, write down or print out the 
    following parameters.
    NOTE: The parameters depend on printers, so the above parameters are shown to another names and  more parameters setting could be needed. Figure 8-178   Printer set backup
    ParametersDescriptions
    Orientation
    Portrait or Landscape
    Paper size Paper size
    Scaling Rate of length and width
    Density AdjustGamma curve
    Table 8-53 Parameters 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1LOGIQ™ P5 SERVICE MANUAL 
    Section 8-3 - Software Loading Procedure 8 - 129
    Section 8-4Software Installation
    8-4-1 Installing Base Image Software
    NOTE: While we do not believe it  is necessary, It would not hurt to disconnect the system from the 
    network and remove all transducers.
    NOTE: All digital peripherals, reporting systems conn ected via the USB ports should be either power 
    off or disconnected prior to the software installation
    1.) Power ON the scanner.
    2.) Tap gently the  DEL key until the following screen appears.Enter “ arirang” as a password if the 
    system request a password, then press the  Enter key.
    3.) Move to  Advanced and select IDE Configuration .
    Figure 8-179   Enter Current Password
    Figure 8-180   IDE Configuration 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1 LOGIQ™ P5 SERVICE MANUAL  
    8 - 130 Section 8-3 - Software Loading Procedure
    8-4-1               Installing Base Image Software (cont’d)
    4.) If the BIOS setting value in  Primary IDE Slave is ATAPI CDROM , the 1st Boot Device in Boot 
    menu should be  Primary Slave. If the 1st Boot Device is not  Primary Slave, please change the 
    setting value using  Enter key and Arrow key.
    5.) If the BIOS setting value in  Secondary IDE Master is ATAPI CDROM, the 1st Boot Device in Boot 
    menu should be  Secondary Master . If the 1st Boot Device is not Secondary Master, please change 
    the setting value using  Enter key and  Arrow key.
    Figure 8-181   Boot Device Priority
    Figure 8-182   IDE Configuration 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1LOGIQ™ P5 SERVICE MANUAL 
    Section 8-3 - Software Loading Procedure 8 - 131
    8-4-1               Installing Base Image Software (cont’d)
    6.) Insert the BT11 Base Image Software Disk into t he CD/DVD ROM drive.
    7.) After restarting th e system, the following sc reen will be displayed.
    Figure 8-183   Boot Device Priority 
    Figure 8-184   Installation Warning 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1 LOGIQ™ P5 SERVICE MANUAL  
    8 - 132 Section 8-3 - Software Loading Procedure
    8-4-1               Installing Base Image Software (cont’d)
    8.) Press Enter key and then the  following screen will be shown. (If  you want to abort installation 
    procedures, press CTRL+C.)
    9.) Press  A key to install the complete disk. Figure 8-185   Base Image Software Inst
    allation Menu
    NOTICESelect A when installing the new HDD or upgrading from BT09. (HDD capacity should be minimum 
    120GB)
    Select  B when replacing C: partition only. It means a ll customer data are NOT deleted. The Ghost pro-
    cedure is performed with data of the drivers D, E, F and Z left.
    Select  C when replacing C: partition and Z:\ partition.  It means all customer data are NOT deleted. The 
    Ghost procedure is performed with data of the driv ers D, E and F left. Z: partition used for reloading 
    C: partition and Application software will be replaced.
    Drive PartitionUsage
    (GRUB) grub data
    C System Files and Application
    D User Defined and Preset 
    E Patient Archive data
    FS wap
    Z  C:\partition Repository  for Reloading Function
    Table 8-54 Drive Partition 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1LOGIQ™ P5 SERVICE MANUAL 
    Section 8-3 - Software Loading Procedure 8 - 133
    8-4-1               Installing Base Image Software (cont’d)
    10.) Approx. twenty(20) minutes later, the following  screen appears. Eject the Base Image Software Disk 
    from the CD/DVD ROM drive.
    11.) After removing the disk from the drive, Press ALT + CTRL + DEL key.
    NOTE: After Installing  Base Image Software, the “General failure  reading drive A. Abort, Retry, Fail?” 
    message can be appeared, but Ignore it! All procedure would be successfully done.
    12.) The following message box can be display ed after the SYSTEM boot up. Press Yes.
    Figure 8-186   Installation Completion
    WARNINGWARNINGRemove the disk from the drive. Otherwise you will be encountered the Base Image 
    Software installation screen iteratively.
    Figure 8-187   System Setting Change 
    						
    							GE HEALTHCARE
    DIRECTION 5394141, REVISION  1 LOGIQ™ P5 SERVICE MANUAL  
    8 - 134 Section 8-3 - Software Loading Procedure
    8-4-2 Verifying Base Image Software
    8-4-2-1 Partition Checks 1.) Reboot the SYSTEM and the Desktop screen will be shown as blow.
    2.) Click Start  button and Run menu, then type  explorer and click OK
    3.) Right-click  My Computer icon on the Desktop and click  Manage. 
    Figure 8-188   Desktop Screen
    Figure 8-189   Executing Windows Explorer
    Figure 8-190   Opening the Manage Window 
    						