    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 35
    2
    [FAX] button: ON ([FAX] LED: ON)
    Digital  key Button Items to check Contents
    Highlighted  display
    e.g. Normal dis-
    play
    e.g.
    [1] A -
    - -
    B - - -
    C 24 V power supply Power ON Power OFF
    D IPC board connection Not connected Connected
    E - - -
    F Polygonal motor rotation status (Motor is rotating  at Output 
    Mode (03)) Abnormal rota- 
    tionNormal rota-
    tion
    G Auger lock switch Lock Unlock
    H Toner cartridge installation switch OFF ON
    [2] A Registration sensor
    Paper present No paper
    B Exit sensor Paper present No paper
    C Auto-toner sensor connection Not connected Connected 
    D Front cover opening/closing switch Cover opened Cove r closed
    E - - -
    F Side cover opening/closing sensor Cover opened Cover  closed
    G Transfer cover opening/closing switch Cover opened C over closed
    H Main motor rotation status (Motor is rotating at O utput 
    Mode (03)) Abnormal rota- 
    tionNormal rota-
    tion
    [3] A -
    - -
    B Key copy counter connection Not connected Connected
    C Job Separator upper stack sensor (When Job Separator is installed) Paper full Paper not full
    Offset Tray separate sensor (When Offset Tray is in stalled) Separator at 
    home position Other than  
    home position
    D Fuser unit connection Fuser unit 
    installed Fuser unit not   
    installed
    E Bridge unit transport sensor-2 (When bridge unit is  installed) No paper Paper present
    F Bridge unit cover opening/closing detection switch (When Bridge unit is installed) Cover opened Cover closed
    Job Separator cover switch (When Job Separator is 
    installed) Cover opened Cover closed
    Offset Tray cover switch (When Offset Tray is insta lled) Cover opened Cover closed
    G Bridge unit paper full detection sensor (When bridge unit is installed) Paper not full Paper full
    Job Separator lower stack sensor 
    (When Job Separator is installed) Paper full Paper not full
    Offset Tray stack sensor (When Offset Tray is instal led) Paper full Paper not full
    H Bridge unit transport sensor-1 (When bridge unit is  installed) No paper Paper present
    Job Separator feed sensor (When Job Separator is 
    installed) Paper present No paper
    Offset Tray feed sensor (When Offset Tray is install ed) Paper present No paper
    [4] A -
    - -
    B - - -
    C - - -
    D - - -
    E - - -
    F Bypass feed sensor No paper Paper present
    G - - -
    H High-voltage power supply abnormality (shutdown) d etec-
    tion Normal Abnormal
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 36
    [5]
    A -
    - -
    B - - -
    C - - -
    D - - -
    E - - -
    F RADF connection RADF con-
    nected Not connected
    G Platen sensor Platen cover 
    opened Platen cover  
    closed
    H Carriage home position sensor Carriage at  home positionOther than  
    home position
    [6] A -
    - -
    B - - -
    C - - -
    D APS sensor (APS-R) No original Original 
    present
    E APS sensor (APS-C) No original Original 
    present
    F APS sensor (APS-3) No original Original 
    present
    G APS sensor (APS-2) No original Original 
    present
    H APS sensor (APS-1) No original Original 
    present
    [7] A RADF tray sensor
    Original 
    present No original
    B RADF empty sensor Original 
    present No original
    C RADF jam access cover switch Cover opened Cover close d
    D RADF opening/closing sensor RADF opened RADF closed
    E RADF exit sensor Original 
    present No original
    F RADF reverse sensor Original 
    present No original
    G RADF read sensor Original 
    present No original
    H RADF registration sensor Original  presentNo original
    [8] A -
    - -
    B - - -
    C - - -
    D - - -
    E RADF original length sensor Original  presentNo original
    F RADF original width sensor-1 Original  presentNo original
    G RADF original width sensor-2 Original  presentNo original
    H RADF original width sensor-3 Original  presentNo original
    Digital 
    key Button Items to check Contents
    Highlighted  display
    e.g. Normal dis-
    play
    e.g.
    05/11 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 37
    2
    Table 2. Connecting status of additional options at  inner area of the equipment
    [9]A Bridge unit/Job Separator/Offset Tray connection d
    etection-
    3 Refer to table 2
    B Bridge unit/Job Separator/Offset Tray connection d etection-
    2 Refer to table 2
    C Bridge unit/Job Separator/Offset Tray connection d etection-
    1 Refer to table 2
    D - - -
    E - - -
    F - - -
    G - - -
    H - - -
    [0] A Dongle (for Printer/Scanner kit (GM-2020 or 2030))
    Connectable Not connect-
    able
    B Dongle (for Printer kit (GM-1020 or 1030)) Connecta ble Not connect-
    able
    C Dongle (for Scanner upgrade kit (GM-3020 or 3030)) Connectable Not connect-
    able
    D Dongles for other equipments/Other USB devices Conn ectable Not connect-
    able
    E - - -
    F - - -
    G - - -
    H - - -
    Bridge unit Job Separator Offset Tray None
    Bridge unit/Job Separator/Offset Tray  connection detection-3 Normal display Highlighting 
    displayHighlighting 
    display Highlighting 
    display
    Bridge unit/Job Separator/Offset Tray  connection detection-2 Highlighting 
    display Highlighting 
    display Normal display Highlighting 
    display
    Bridge unit/Job Separator/Offset Tray  connection detection-1 Normal display Normal display Normal display Highlight
    ing 
    display
    Digital 
    key Button Items to check Contents
    Highlighted  display
    e.g. Normal dis-
    play
    e.g.
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 38
    [FAX] button: OFF/ [COPY] button: ON ([FAX] LED: OF F/ [COPY] LED: ON)
    *1  Be sure to install the USB storage device to the e quipment and check if the device can be used 
    with this code.
     Be sure to turn OFF the write protection (the func tion to prevent data from erasure by the acci-
    dental recording or deleting) of the USB storage de vice before performing the check, otherwise 
    this code cannot be used.
     It may take some time (2 sec. to 10 sec.) before t his check is completed depending on the USB 
    storage device.
    Digital  key Button Items to check Contents
    Highlighted  display
    e.g. Normal dis-
    play
    e.g.
    [0] A Dongle (for Printer/Scanner kit (GM-2070 or 2080U)
    ) Con-
    nected Connectable Not connect-
    able
    B Dongle (for Printer kit (GM-1070 or 1080U)) Connec ted Connectable Not connect-
    able
    C Dongle (for Scanner kit (GM-4070 or 4080U)) Connec ted Connectable Not connect-
    able
    D Dongles for other equipments/Other USB devices Con -
    nected Connectable Not connect-
    able
    E Judgement for acceptable USB storage device (*1) Acc eptable Not acceptable
    F - - -
    G - - -
    H - - -
    05/11 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 39
    2
    2.2.3 Output check (test mode 03)
     
    Procedure 1 
    Procedure 2 
    Procedure 3 
    Procedure 4 Status of the output signals can be checked by keyin
    g in the following codes in the test mode 03.
    [0][3]
    [POWER] [POWER] OFF/ON
    (Exit)
    [START]
    (Code) Operation
    ON Stop
    code Operation
    OFF[START]
    [0][3]
    [POWER] [POWER] OFF/ON
    (Exit)
    [START] [CLEAR]
    Operation
    One direction Test mode
    standby(Code)
    [0][3]
    [POWER] [POWER]
    OFF/ON (Exit)
    (Code)[START][START]
    Operation
    ON Test mode
    standby[CLEAR]
    Operation
    OFF
    [0][3]
    [POWER] [POWER] OFF
    [START]
    (Code) 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 40
    Code Function Code Function Procedure
    101 Main motor ON (operational without  developer unit) 151 Code No. 101 function OFF 1
    102 Toner motor ON (normal rotation) 152 Code No. 102  function OFF 1
    103 Polygonal motor ON (600 dpi) 153 Code No. 103 func tion OFF 1
    108 Registration clutch ON 158 Code No. 108 function O FF 1
    109 PFP motor ON 159 Code No. 109 function OFF 1 110 ADU motor ON (low speed) 160 Code No. 110 function  OFF 1
    118 Laser ON 168 Code No. 118 function OFF 1
    120 Exit motor ON (normal rotation) 170 Code No. 120 f unction OFF 1
    121 Exit motor ON (reverse rotation) 171 Code No. 121  function OFF 1
    122 LCF motor ON 172 Code No. 122 function OFF 1 
    177 Offset Tray motor ON (reciprocating movement) 2
    201 Upper drawer feed clutch ON/OFF 3
    202 Lower drawer feed clutch ON/OFF 3
    203 Upper transport clutch ON/OFF 3
    204 Bypass feed clutch ON/OFF 3
    205 Middle transport clutch ON/OFF 3
    206 LCF pickup solenoid ON/OFF 3
    207 LCF end fence reciprocating movement 2
    208 LCF end fence motor ON/OFF 3
    209 LCF feed clutch ON/OFF 3
    210 LCF transport clutch ON/OFF 3
    217 Lower transport clutch ON/OFF 3
    218 Key copy counter count up 2
    222 ADU clutch ON/OFF 3
    225 PFP transport clutch ON/OFF 3
    226 PFP upper drawer feed clutch ON/OFF 3
    228 PFP lower drawer feed clutch ON/OFF 3
    232 Bridge unit gate solenoid ON/OFF 3
    234 Bypass pickup solenoid ON/OFF 3
    235 Discharge LED ON/OFF 3
    236 Exhaust fan ON/OFF (low speed) 3
    237 Exhaust fan ON/OFF (high speed) 3
    242 Upper drawer tray-up motor ON (tray up) 2
    243 Lower drawer tray-up motor ON (tray up) 2
    248 Developer bias [+DC] ON/OFF 3
    249 Developer bias [-DC] ON/OFF 3
    252 Main charger ON/OFF 3
    253 Separation bias ON/OFF 3
    255 Transfer guide bias ON/OFF 3
    256 Transfer transformer ON/OFF 3
    261 Scan motor ON (Automatically stops at limit posit ion; speed can be changed with the 
    [ZOOM] button 2
    264 SLG board cooling fan 1 ON/OFF 3
    265 SLG board cooling fan 2 ON/OFF 3
    267 Scanner exposure lamp ON/OFF 3
    05/11 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 41
    2
    Code Function Procedure
    271 LCF tray-up motor (up/down) 2
    278 PFP upper drawer tray-up motor ON (tray up) 2
    280 PFP lower drawer tray-up motor ON (tray up) 2
    281 RADF feed motor ON/OFF (normal rotation) 3
    282 RADF feed motor ON/OFF (reverse rotation) 3
    283 RADF read motor ON/OFF (normal rotation) 3
    284 RADF reverse motor ON/OFF (normal rotation) 3
    285 RADF reverse motor ON/OFF (reverse rotation) 3
    289 Internal cooling fan 1 ON/OFF (high speed) 3
    290 Internal cooling fan 1 ON/OFF (low speed) 3
    294 RADF reverse solenoid ON/OFF 3
    295 Power OFF mode (for 200 V series) 4
    297 RADF fan motor ON/OFF 3
    410 Internal cooling fan 2 ON/OFF (low speed) 3
    411 Internal cooling fan 2 ON/OFF (high speed) 3
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 42
    2.2.4 Test print mode (test mode 04)
    
    Notes: 
    1. When an error occurs, it is indicated on the panel , but the recovery operation is not per-
    formed. Turn OFF the power and then back ON to clea r the error.
    2. During test printing, the [CLEAR] button is disab led when “Wait adding toner” is displayed.
    The embedded test pattern can be printed out by key
    ing in the following codes in the test print mode 
    (04).
    Code Types of test pattern Remarks
    111 Primary scanning direction 33 gradation steps Err or diffusion
    113 Secondary scanning direction 33 gradation steps E rror diffusion
    142 Grid pattern Pattern width: 2 dots, Pitch: 10 mm
    [0][4]
    [POWER] [POWER] OFF/ON
    (Exit)
    (Code)
    [START] [CLEAR]
    Operation
    Continuous
    Test Printing 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 43
    2
    2.2.5 Adjustment mode (05) (e-STUDIO200L/230/280)
    Procedure 1 
    Procedure 2 
    Procedure 3 
    Procedure 4 Items in the adjustment mode list in the following 
    pages can be corrected or changed in the adjust-
    ment mode (05). Turn ON the power with pressing the  digital keys [0] and [5] simultaneously in 
    order to enter this mode.
    [0][5]
    [POWER] [POWER]
    OFF/ON
    (Exit)[Digital key] (Code) [START]
    [CANCEL] [Digital key]
    *[FUNCTION CLEAR]
    (Key in a value)
    [CLEAR]
    (Corrects value) [ENTER]
    or
    [INTERRUPT]
    (Stores value in RAM) ([FAX])
    (Test copy)
    *Press [
    FUNCTION CLEAR] to enter minus (-).
    [0][5]
    [POWER] [POWER]
    OFF/ON (Exit)(Code) [START] [ENTER]
    or
    [INTERRUPT]
    (Value unchangeable) ([FAX])
    (Test copy)
    Value
    displayed( )
    [0][5]
    [POWER] [POWER]
    OFF/ON (Exit)[Digital key] (Code) [START]
    [CANCEL] [UP]
    or
    [DOWN]
    (Adjust a value)
    [CLEAR]
    (Corrects value) [ENTER]
    or
    [INTERRUPT]
    (Stores value in RAM) ([FAX])
    (Test copy)
    [0][5]
    [POWER] [POWER]
    OFF/ON (Exit)
    [Digital key]
    (Code) [Digital key]
    *
    [FUNCTION CLEAR][START] [START]
    [Digital key]
    (Sub code)
    [CLEAR]
    (Corrects value)
    [CLEAR]
    (Corrects value) [ENTER]
    or
    [INTERRUPT]
    *Press [FUNCTION CLEAR] to enter minus (-).
    (Key in a value) Stores value
    in RAM
    ( )
    ([FAX])
    (Test copy)
    [CANCEL]
    [START]
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 44
    Procedure 6 
    * When the automatic adjustment ends abnormally, err or message is displayed.
    Procedure 7 
    * When the automatic adjustment ends abnormally, err or message is displayed.
    Procedure 10 
    Procedure 17
    * When the “storing is not performed within 2 minute s after pressing the [START] button at the 
    manual adjustment, the “automatic adjustment” start s automatically.
    Note: Note: 
    The fuser roller temperature control at the adjustm ent mode is different from that at the normal 
    state. 
    Therefore, the problem of fusing efficiency may be  occurred in the test copy at the adjustment 
    mode. In that case, turn ON the power normally, lea ve the equipment for approx. 3 minutes after 
    it has become ready state and then start up the adj ustment mode again.
    [0][5]
    [POWER] [POWER]OFF/ON
    (Exit)[Digital key]
    (Code) [START]( )Automatic
    adjustment ([FAX])
    (Test copy)
    *[CANCEL] or [CLEAR]
    [0][5]
    [POWER] [POWER]
    OFF/ON
    (Exit)[Digital key] (Code) [START]( )Automatic
    adjustment ([FAX])
    (Test copy)
    *[CANCEL] or [CLEAR] [CANCEL]
    ( )
    [ENTER]
    Stores value
    in RAM
    [0][5]
    [POWER] [POWER]
    OFF/ON
    (Exit)
    [Digital key]
    (Code) [Digital key]
    (Sub code)
    [START]
    [START]
    [START]
    [SET] or [INTERRUPT] (Value unchangeable)( )Value
    displayed
    [0][5]
    [POWER] [POWER]
    OFF/ON (Exit)
    [Digital key]
    (Code) [START]
    Automatic
    adjustment [ENTER]
    or
    [INTERRUPT]
    Stores value in RAM
    ( )
    [ENTER] or
    [INTERRUPT]
    Stores value in RAM
    ( )
    ([FAX])
    (Test copy)[UP] or
    [DOWN]
    (Adjust a value)
    [CANCEL] or [CLEAR]
    ( )
    [UP]
    or
    [DOWN]
    (Adjust a value)
    [CANCEL] or [CLEAR]
    )(Manual
    adjustment 
    						
    All Toshiba manuals Comments (0)