Toshiba Estudio 230 Manual
Have a look at the manual Toshiba Estudio 230 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 75 3 [B] Adjustment (1) Close the RADF. (2) Adjust it by turning the adjustment screws on th e hinges. Adjust the height on the rear side by means of the screw on the hinge on the feed side of the RADF. Turn it clockwise ................. Heightened Turn it counterclockwise ...... Lowered Fig.3-93 Adjust the gap on the rear side by means of the scr ew on the hinge on the feed side of the RADF. Turn it clockwis .................... Lowered Turn it counterclockwise ...... Heightened Fig.3-94 05/11
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 76 3.11.3 Adjustment of Skew Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. Also, the RADF position and height shall be adjusted properly. [A] Checking Check the image using the chart (original) with vert ical and horizontal lines in the following procedure. Fig.3-95 Chart (Original) Simplex copying: (1) Place the chart provided as an original with its face up on the original tray of the RADF, select [1 Sided -> 1 Sided] and press the [START] button. (2) Superimpose the chart on the copy and check the inclination of the copy image. Duplex copying: (1) Place the chart provided as an original with its face up on the original tray of the RADF, select [2 Sided -> 2 Sided] and press the [START] button. (2) Superimpose the chart on the copy and check the inclination of the copy image. 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 77 3 [B] Adjustment Simplex copying: (1) Shift the aligning plate with the scale as the g uide shown in the figure below to adjust the skew. Fig.3-96 (2) If the image skew is C as shown in the figure below, shift the aligning plate in the direction of +, and if D, shift it to -. Fig.3-97 Fig.3-98 Shift the aligning plate in the direction of +. Sh ift the aligning plate in the direction of -. C D 05/11
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 78 Duplex copying: (1) Shift the aligning plate with the scale as the g uide shown in the figure below to adjust the skew. Fig.3-99 (2) If the image skew is C as shown in the figure below, shift the aligning plate in the direction of - , and if D, shift it to +. Fig.3-100 Fig.3-101 Shift the aligning plate in the direction of -. S hift the aligning plate in the direction of +. C D 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 79 3 3.11.4 Adjustment of the Leading Edge Position Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. Also, the RADF position and height shall be adjusted properly. [A] Checking Check the image using the chart (original) with vert ical and horizontal lines in the following procedure. Simplex copying: (1) Place the chart provided as an original with its face up on the original tray of the RADF, select [1 Sided -> 1 Sided] and press the [START] button. (2) Superimpose the chart on the copy and check the leading edge E of the chart and F of the copy. Duplex copying: (1) Place the chart provided as an original with its face up on the original tray of the RADF, select [2 Sided -> 2 Sided] and press the [START] button. (2) Superimpose the chart on the copy and check the leading edge E of the chart and F of the copy. [B] Adjustment Simplex copying: (1) Turn the power ON while pressing [0] and [5] sim ultaneously, key in [365] and then press the [START] button. (2) Enter the value. If the leading edge (F) margin of the copy image i s larger than the (E) margin of the chart, enter a value smaller than the current one. Note: Note: Changing one value shifts the copy image by 0.1 mm. If the leading edge (F) margin of the copy image i s smaller than the (E) margin of the chart, enter a value larger than the current one. Note: Note: Changing one value shifts the copy image by 0.1 mm. (3) Press the [ENTER] button. Fig.3-102 Chart (Original) Fig.3-103 Copy EF 05/11
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 80 Duplex copying: (1) Turn the power ON while pressing [0] and [5] sim ultaneously, key in [366] and then press the [START] button. (2) Enter the value. If the leading edge (F) margin of the copy image i s larger than the (E) margin of the chart, enter a value smaller than the current one. Note: Note: Changing one value shifts the copy image by 0.1 mm. If the leading edge (F) margin of the copy image i s smaller than the (E) margin of the chart, enter a value larger than the current one. Note: Note: Changing one value shifts the copy image by 0.1 mm. (3) Press the [ENTER] button. 3.11.5 Adjustment of Horizontal Position Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. Also, the RADF position and height shall be adjusted properly. [A] Checking Check the image using the chart (original) with a c enter line in the following procedure. (1) Place the chart provided as an original with its face up on the original tray of the RADF. (2) Press the [START] button. (3) Fold the copy in half and check if the center li ne is misaligned. [B] Adjustment (1) Turn the power ON while pressing [0] and [5] sim ultaneously. (2) Key in [358] and then press the [START] button. If the center line of the copy image is shifted to the front side of the equipment, enter a value larger than the current one. Note: Note: Changing one value shifts the copy image by 0.042 mm . Fig.3-104 If the center line of the copy image is shifted to the rear side of the equipment, enter a value smaller than the current one. G 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 81 3 Note: Note: Changing one value shifts the copy image by 0.042 mm . Fig.3-105 (3) Press the [ENTER] button. H 05/11
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 82 3.11.6 Adjustment of Copy Ratio Note: Note: Check if the image adjustment for the equipment is p erformed properly before this adjustment of the RADF. Also, the RADF position and height shall be adjusted properly. [A] Checking Check the image using the chart (original) with vert ical and horizontal lines in the following procedure. (1) Place the chart provided as an original with its face up on the original tray of the RADF. (2) Press the [START] button. (3) Superimpose the chart on the copy and check the image dimension “I”. [B] Adjustment (1) Turn the power ON while pressing [0] and [5] sim ultaneously. (2) Key in [357] and then press the [START] button. If the copy image dimension “I” is larger than the chart dimension, enter a value smaller than the current one. If the copy image dimension “I” is smaller than th e chart dimension, enter a value larger than the current one. Fig.3-106 (3) Press the [ENTER] button. I 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 83 3 3.11.7 Adjustment of RADF Opening/Closing Sensor Adjust the bracket position so that the sensor is t urned ON when the height “A” becomes 100 mm or less (within the empty weight falling limit). Fig.3-107 Fig.3-108 A 05/11
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 84 3.12 Adjustment of the Finisher (MJ-1022) 3.12.1 Adjusting the jogging plate width (1) Remove the right inner cover and the rear cover. (4) Measure the jogging width (standard at 317 mm). (2) Adjust the front jogging plate to the home position. Set SW1 on the finisher controller PC board as shown in P.3-84 Fig.3-109 . Press SW2 twice on the finisher controller PC board. - The front jogging plate moves to the home position. Fig.3-109 (3) Adjust the rear jogging plate to the home position. Set SW1 on the finisher controller PC board as shown in P.3-84 Fig.3-110 . Press SW2 twice on the finisher controller PC board. - The rear jogging plate moves to the home position. Fig.3-110 Fig.3-111 1 2 3 5 6 7 8 4 ON 1 2 3 4 5 6 7 8 ON Front jogging plate home position Rear jogging plate home position Jogging width 317mm