June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 5 3 3.2.2 Paper alignment at the registration roller The aligning amount is adjusted by using the follow ing codes in Adjustment Mode (05). Sub-code (*1) 0: Long size 1: Middle size 2: Short size (*2) 0: Long size 1: Middle size 2: Short size 3: P ost card (*3) 0: Long size of OHP film 1: Middle size of OHP film 2: Short size of OHP film Notes: 1. Long size: 330 mm or longer (13.0 inches or longe r) Middle size: 220-239 mm (8.7-12.9 inches) Short size: 219 mm or shorter (8.6 inches or shorte r) 2. The adjustment of “Post card” is for Japan only. (1) Perform the test print according to the followin g procedure. Paper type Weight Upper drawer Lower drawer PFP upper drawer PFP lower drawer LCF ADU Bypass feed Plain paper 64-80 g/m 2 17-20 lb. 450 (*1) 452 (*1) 448 (*1) 449 (*1) 457 455 (*1) 458 (*1) Thick paper 1 81-105g/m 2 21-28 lb. 469 (*1) 470 (*1) 471 (*1) 472 (*1) 473 474 (*1) 460 (*1) Thick paper 2 106-163g/m 2 29-43 lb. - - - - - - 461 (*1) Thick paper 3 164-209g/m 2 44-55 lb. - - - - - - 462 (*2) OHP - - - - - - - 463 (*3) (*4) 1: Single-sided grid pattern 3: Double-sided gr id pattern (Code) [START] (Sub-code) [START][0][5] [Power]Current value displayed Enter new value [POWER]OFF/ON (Exit) [Drawer selection](*4) +[FAX] (Test print) [SET] or [INTERRUPT] Stores in memory (Not necessary for LCF)
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 6 (3) Perform the same procedure for all paper sources. Note: Note: When paper thinner than specified is used, paper ja ms may occur frequently at the registration section. In this case, it is advisable to change (or reduce) the aligning amount. However, if the aligning amount is reduced too much , this may cause the shift of leading edge position. So, when adjusting the aligning amount, t ry to choose the appropriate amount while confirming the leading edge position is not shifted . * As a tentative countermeasure, the service life of the feed roller can be extended by increas- ing the aligning amount. (2) Check if any transfer void is occurring. If there is a transfer problem, try the values in descending order as “31” “30” “29”··· until the transfer void disappears. At the same time, confirm if any paper jam occurs. Also, when the aligning amount has been increased, this may increase the scraping noise caused by the paper and the Mylar sheet as it is transported by the registration roller. If this scraping noise is annoying, try to decrease the value. Fig.3-7 50mm - 100mm Transfer void
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 7 3 3.2.3 Printer related adjustment [A] Reproduction ratio of primary scanning direction (Fine adjustment of polygonal motor rotation speed (Printer)) (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Press [1] [FAX]. (A grid pattern with 10 mm squares is print ed out. Use A3/LD from standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (3) Check the grid pattern on the test chart printed out and measure the distance A from the 1st line to the 21st line of the grid pattern. (4) Check if the distance A is within 200±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance A again. (Adjustment Mode) (Key in code [401]) [START] (Key in a value (acceptable values: 0 to 255)) [ENTER] or [INTERRUPT] (Stored in memory) “100% A” is displayed Press [1] [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance A becomes (approx. 0.125 mm/step). [B] Primary scanning data laser writing start positi on (Printer) (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Press [1] [FAX]. (A grid pattern with 10 mm squares is print ed out. Use A3/LD from standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (3) Check the grid pattern on the test chart printed out and measure the distance B from the left edge of the paper to the 6th line of the grid pattern. (4) Check if the distance B is within 52±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance B again. (Adjustment Mode) (Key in the code [411]) [START] (Key in a value (acceptable values: 0 to 255)) [ENTER] or [INTERRUPT] (Stored in memory) “100% A” is displayed Press [1] [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance B becomes (approx. 0.05 mm/step). 04/09
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 8 (6) After the adjustment for the code 411 is complet ed, apply the same adjustment value for the code 410. (Adjustment Mode) (Key in the code [410]) [START] (Key in the same value in the step 5 above) Press [ENTER] or [INTERRUPT] (Stored in memory). Note: Note: Make sure the first line of the grid pattern is pri nted out since the line is occasionally vanished. [C] Reproduction ratio of secondary scanning directi on (Fine adjustment of main motor rotation speed (Copier/Printer)) (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment mode) (2) Press [1] [FAX]. (A grid pattern with 10 mm squares is print ed out. Use A3/LD from standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (3) Check the grid pattern on the test chart printed out and measure the distance C from the 10th line at the leading edge of the paper to the 30th l ine of the grid pattern. *Normally, the 1st line of the grid pattern is not printed. (4) Check if the distance C is within 200±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance C again. (Adjustment Mode) (Key in code [421]) [START] (Key in a value (acceptable values: 0 to 255)) [ENTER] or [INTERRUPT] (Stored in memory) “100% A” is displayed Press [1] [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance C becomes (approx. 0.125 mm/step). 04/09
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 9 3 [D] Secondary scanning data laser writing start posi tion This adjustment has to be performed for each paper source. (If there is no paper source, skip this step.) The following table shows the order of the paper so urce to be adjusted, code, paper size and accept- able values. Perform 08-477 and check the value. When the value is 0. When the value is 1. (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Press [1] ([3] for duplexing) [FAX]. (A grid pattern with 10 mm squares is print ed out.) (3) Check the grid pattern on the test chart printed out and measure the distance D from the leading edge of the paper to the 6th line of the grid patte rn. *Normally, the 1st line of the grid pattern is not printed. *At the duplexing, measure it on the top side of th e grid pattern. (4) Check if the distance D is within 52±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance D again. (Adjustment Mode) (Key in the code shown above) [START] (Key in an acceptable value shown above) [ENTER] or [INTERRUPT] (Stored in memory) “100% A” is displayed Press [1] ([3] for duplexing) [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance D becomes (approx. 0.4 mm/step). Order for adjustment Paper source Code Paper size Acceptable value Remarks 1 Lower drawer 441 A3/LD 0 to 40 2 Upper drawer 440 A4/LT 0 to 15 3 PFP or LCF 444/443 A4/LT 0 to 15 4 Bypass feed 442 A4/LT 0 to 15 5 Duplexing 445 A3/LD 0 to 15 Paper fed from the lower d rawer Order for adjustment Paper source Code Paper size Acceptable value Remarks 1 Upper drawer 440 A3/LD 0 to 40 2 Lower drawer 441 A4/LT 0 to 15 3 PFP or LCF 444/443 A4/LT 0 to 15 4 Bypass feed 442 A4/LT 0 to 15 5 Duplexing 445 A3/LD 0 to 15 Paper fed from the upper d rawer 05/05
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 10 [E] Primary scanning data laser writing start positi on at duplexing Note: Note: Make sure the first line of the grid pattern is pri nted out since the line is occasionally vanished. [E-1] Adjustment for long-sized paper (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Press [3] [FAX]. (A grid pattern with 10 mm squares is print ed out. Use A3/LD from standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (3) Check the grid pattern on the test print and mea sure the distance E from the left edge of the paper to the 6th line of the grid pattern. (4) Check if the distance E is within 52±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance E again. (Adjustment Mode) (Key in code [498]) [START] [0] [START] (Key in a value (acceptable values: 0 to 255)) [ENTER] or [INTERRUPT] (Stored in memory) “100% A” is displayed. Press [3] [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance E becomes (approx. 0.05 mm/step). [E-2] Adjustment for short-sized paper (1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode) (2) Press [3] [FAX]. (A grid pattern with 10 mm squares is print ed out. Use A4/LT from the upper drawer.) (3) Check the grid pattern on the test print and mea sure the distance E from the left edge of the paper to the 6th line of the grid pattern. (4) Check if the distance E is within 52±0.5 mm. (5) If not, use the following procedure to change val ues and measure the distance E again. (Adjustment Mode) (Key in the code [498]) [START] [1] [START] (Key in a value (acceptable values: 0 to 255)) [ENTER] or [INTERRUPT] (Stored in memory). “100% A” is displayed Press [3] [FAX] (A grid pattern is printed out.) *The larger the adjustment value is, the longer the distance E becomes (approx. 0.05 mm/step). 04/09
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 11 3 Fig.3-8 Grid pattern Perform 08-477 and check the value. When the value is 0. [0] [5] [Power ON] [1] ([3](05-445, 498) for duplexing) [FAX] A: 05-401 (Lower drawer, A3/LD) 200±0.5 mm (0.125 mm/step) B: 05-411 (Lower drawer, A3/LD) 52±0.5 mm (0.05 mm/step) Key in the same value for 05-410. C: 05-421 (Lower drawer, A3/LD) 200±0.5 mm (0.125 mm/step) D: 05-441 (Lower drawer, A3/LD), 440 (Upper drawer, A4/LT), 444 (PFP, A4/LT), 443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Du plexing, A3/LD) 52±0.5 mm(0.4 mm/step) E: 05-498-0 (Lower drawer, A3/LD), 498-1 (Upper drawer, A4/LT) 52±0.5 mm (0.05 mm/step) A 21 61 B, E D 6 30 2 C 10 Feeding direction 04/09
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 12 Remark: When the adjustment (05-421) is performed, the same adjustment for FAX (05-422) is automati- cally and consecutively performed. 3.2.4 Scanner related adjustment [A] Image distortion Fig.3-9 When the value is 1. [0] [5] [Power ON] [1] ([3](05-445, 498) for duplexing) [FAX] A: 05-401 (Upper drawer, A3/LD) 200±0.5 mm (0.125 mm/step) B: 05-411 (Upper drawer, A3/LD) 52±0.5 mm (0.05 mm/step) Key in the same value for 05-410. C: 05-421 (Upper drawer, A3/LD) 200±0.5 mm (0.125 mm/step) D: 05-440 (Upper drawer, A3/LD), 441 (Lower drawer, A4/LT), 444 (PFP, A4/LT), 443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Du plexing, A3/LD) 52±0.5 mm(0.4 mm/step) E: 05-498-0 (Upper drawer, A3/LD), 498-1 (Upper drawer, A4/LT)) 52±0.5 mm (0.05 mm/step) Feeding direction Feeding direction Step 1 A Step 2 C B D 05/05
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 13 3 (1) While pressing [0] and [5] simultaneously, turn the power ON. (2) Press [FAX] to make a copy of any image on a sheet of A3/LD paper. (3) Key in [308] and press the [START] button to move the carriage to the adjustment position. (4) Make an adjustment in the order of step 1 and 2. Step 1- In case of A:Tighten the mirror-3 adjustment screw (CW). - In case of B: Loosen the mirror-3 adjustment screw (CCW). Step 2 - In case of C:Tighten the mirror-1 adjustment screw (CW). - In case of D: Loosen the mirror-1 adjustment screw (CCW). (5) Apply the screw locking agents to the adjust- ment screws. (2 areas) Recommended screw lock agentManufacturer: Three Bond Product name: 1401E Fig.3-10 Fig.3-11 Carriage-2 Adjustment screw for the mirror-3 (Rear) Adjustment screw for the mirror-1 (Rear) Carriage-1
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 14 [B] Reproduction ratio adjustment of the primary sca nning direction (1) While pressing [0] and [5] simultaneously, turn the power ON (Adjustment Mode) (2) Place a ruler on the original glass (along the d irection from the rear to the front of the equipment). (3) Press [FAX] to make a copy at the mode of A3 (LD ), 100% and standard drawer of the equipment (Refer to *). *Perform 08-477 and check the value. If the value is 0, use the lower drawer. If the value is 1, use the upper drawer. (4) Measure the distance A from 10 mm to 270 mm of t he copied image of the ruler. (5) Check if the distance A is within the range of 2 60±0.5 mm. (6) If not, use the following procedure to change val ues and repeat the steps (3) to (5) above. (Adjustment Mode) (Key in the code [405]) [START] (Key in a value (acceptable values: 0 to 255)) Press the [ENTER] or the [INTERRUPT] button (store d in memory). (“100% A” is displayed.) *The larger the adjustment value is, the higher the reproduction ratio and the longer the distance A become (approx. 0.125 mm/step). Fig.3-12 50 100 150 200 250 A Feeding direction Copied image of the ruler 04/09