    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 77
    6
    Updating the system ROM starts subsequently. 
    The device check starts. 
    When the device check completes, copying the  
    data to the ROM of the equipment starts. 
    When copying the data completes, copying the  
    other data are implemented repeatedly. 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 78
    When copying all the data complete, the update  
    completes with the following screen.
    * If the USB storage device is not recognized proper ly, the following message is displayed and the 
    update is interrupted. 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 79
    6
    * If an error occurs, the following error message is  displayed and the update is interrupted. 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 80
    6.5 Firmware Updating with USB Storage Device 
    (e-STUDIO202L/232/282)
    In this equipment, it is feasible to update the fir mware by connecting the USB storage device on which  
    the firmware data is written to the USB connector m ounted on the system control PC board and turning 
    ON the power. 
    The type of firmware to be updated can be selected  on the LCD screen in this method. This allows to 
    update only the necessary firmware individually or t o update all firmware in a batch.
    The type of firmware which can be updated with this  method are as follows in the table below.
    Firmware StoredModel specific 
    folder name Data file name
    Master data Hard disk
    202_2821, 2, 3 ... n 
    * The file name should be consecutive 
    numbers from 1 to “n” without file  
    extension. The capacity of each file  
    is approx. 8 MB. However, the file 
    capacity of “n” (last number) may be  
    less than 8 MB.
    System ROM System control PC board (SYS board) firmImage0.bin, firmImage1.bin
    Engine ROM Logic PC board (LGC board) firmImage2.bin
    Scanner ROM Scanning section control PC board (SLG board)
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 81
    6
    Important:   Only the USB storage device which meets the follow ing conditions should be used for updat-
    ing. Be careful since updating with any device othe r than the above is never guaranteed.
    - A combination USB storage device with a flash memo ry (to be connected directly to the 
    USB port) and its capacity is between 64 MB to 512 M B (or 1 GB).
    - Operation of the USB storage device used for updat ing has been confirmed at the input 
    check of this equipment (Test mode 03). (   P.2-31 2.2.2 Input check (Test mode 03) (e-STUDIO2 02L/232/282))
    - A USB storage device which is complied with the fo llowing standards regulated by USB-IF 
    (USB Implementers Forum)
    Class number:  8 (=08h) (Mass-storage class)
    Sub-class number:  6 (=06h) (SCSI transfer command s et)
    Protocol number:  80 (=50h) (Bulk-Only) 
    * Most common USB storage devices are complied with  the specification above and can 
    be used for updating. However, the operation in all  the Multi Functional Digital Color 
    Systems and Multi Functional Digital Systems is not  necessarily guaranteed since the 
    most of these devices are developed based on the use  in PC environment (Windows or 
    Macintosh). Therefore, confirm thoroughly that the  device is operational in the equip-
    ment for which the updating will be performed when  purchasing the device.
     The data file for updating is stored in the model  specific folder.
    Never change the model specific folder name since it  is used for discriminating the data file 
    when the updating data files for multiple models ar e stored in the USB storage device.
     Store the model specific folder in the root direct ory of the USB storage device.
     Storing the data file directly in the root directo ry is possible when the updating data files for 
    one specific model is stored in the USB storage dev ice.
    However, if the model specific folder for the same  model as that of the data file stored in the 
    root directory already exists, the model specific fo lder will have the priority.
     The USB storage device complied with USB1.1 and US B2.0 can be used for updating. How-
    ever, the update is performed in the speed of USB1.1  when the device complied with USB2.0 
    is used.
     Do not update the firmware by any storage device o ther than a flash memory (such as a USB 
    connection type memory card reader, CD/DVD drive or  hard disk) since it is never guaran-
    teed.
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 82
    [A] Update procedure
    Important:   The file system of USB storage device should be fo rmatted in FAT format. Be careful since 
    the devices formatted in FAT32 or NTFS format will  not be operated. The file system can be 
    confirmed on the properties in applications such as  Explorer of Windows.
     Do not turn OFF the power during the update. The d ata could be damaged and not to be 
    operated properly.
    (1) Connect the USB storage device to the PC and wri te the model specific folder in which the data 
    file is stored. 
     Confirm the model specific folder name and data fi le name before writing the data 
    (   P.6-80 6.5 Firmware Updating with USB Storage Dev ice (e-STUDIO202L/232/282)).
     The file system of USB storage device should be fo rmatted in FAT format.
     Windows 95 and NT do not support USB. Be careful s ince the data can not be written on the 
    devices in the PCs with these operating systems.
    (2) Shut down the equipment. 
    (3) Connect the USB storage device to the USB connec tor (host) on the SYS board.
     Fig.6-79
    Notes: 
     Do not connect multiple USB storage devices togeth er. 
     The USB storage device can be connected to either  of 2 USB connectors (host). 
     In case the printer kit (GM-1070 or GM-1080U), pri nter/scanner kit (GM-2070 or GM-2080U) 
    and scanner upgrade kit (GM-4070 or GM-4080U) are u sed, the update must be performed 
    after all the dongles are disconnected from the U SB connector (host) and only the USB stor-
    age device is connected. 
    USB storage device USB connector (
    host )
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 83
    6
    (4) Turn ON the power while [4] button and [9] butto n are pressed simultaneously. 
    The screen for selecting the items to be updated is  displayed after 3 minutes. “*” is displayed 
    next to the items to be updated. (All items other t han 0. OS Update are selected in the default 
    settings.)
    Note: Note:  The display of items on this screen varies dependin g on the types of data written on the USB 
    storage device. Each item is displayed only when ea ch data file is written on the USB storage 
    device in the following conditions.
    Item Condition
    0. OS Update firmImage0.bin is written. 
    1. HDD Update All master data files (1, 2, 3 ... n)  are written.
    2. UI Data Update firmImage0.bin is written.
    3. System Firmware Update firmImage0.bin and firmIma ge1.bin are written.
    4. Engine Firmware Update firmImage2.bin is written.
    5. Scanner Firmware Update firmImage2.bin is written .
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 84
    If the USB storage device is not recognized properl y, the following message is displayed. In this 
    case, disconnect the USB storage device and connect  it again within 3 minutes, or turn OFF the 
    power of the equipment and connect the device prope rly. Then repeat the procedure from (4).
    If the updating data file does not exist or a data  file for other model is stored, the following mes-
    sage is displayed. In this case, turn OFF the power  of the equipment and confirm if the data file 
    stored in the USB storage device is correct. Then r epeat the procedure from (4).
    06/01 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 85
    6
    (5) Select the item with the digital keys. “*” is displayed next to the selected item. Display  or delete the “*” by pressing the number of the 
    item. All items are selected in the default setting s.
     Select all items to update the firmware of the equ ipment in a batch.
     Select items as follows to update individually. 
     
    Select “0. OS Update” only. 
     
    Select “1. HDD Update” only. 
     
    Select “2. UI Data Update” and “3. System Firmware  Update”.
    
    Select “4. Machine Firmware Update” only. 
     
    Select “5. Scanner Firmware Update” only. 
    Example : Updating the master data and system ROM
    (Updating all the items is taken as an example and  explained in the following procedures.) 
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 86
    (6) Press the [START] button. Updating starts and the processing status is display ed on the LCD screen.
    (7) “Update Completed.” is displayed at the bottom o f the LCD screen after the updating is com-
    pleted properly.
    Status display during update Status display when upd ate is completed 
    OS Update  ....... OS Update  ....... Completed 
    HD Data Update  ....... HD Data Update  ....... Complet ed
    UI Data Update  ....... UI Data Update  ....... Complet ed
    SysFirm Update  ....... SysFirm Update  ....... Complet ed
    Engine MAIN Update .. Flash Update Engine MAIN Update  .. Completed
    Scanner Firm Update.. Flash Update Scanner Firm Updat e.. Completed
    05/11 
    						