    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 37
    6
    “Update Failed.” is displayed at the bottom of the  LCD screen when the updating is not com-
    pleted properly. “Failed” appears next to the faile d item on the status display.  Turn OFF the 
    power, and then check the following items.  After c onfirming and cleaning the problems, restart 
    updating from the beginning. 
     Is the download jig connected properly?
     Is the updating data written to the download jig p roperly?
     Do the download jig and the equipment operate prop erly?
    (9) Turn OFF the power, remove the download jig and  install the cover plate and the connector 
    cover.
    (10) Perform the initialization of the updating data .
     Turn ON the power while [0] button and [8] button  are pressed simultaneously.
     Key in “947”, and then press the [START] button.
     Press the [INITIALIZE] button.
    [B] Confirmation of the updated data 
    After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the 
    data was overwritten properly.
     
    08-900: System ROM version
    08-920: FROM basic section software version 
    08-921: FROM internal program version 
    08-922: UI data fixed section version 
    08-923: UI data common section version
    08-930: Version of UI data in FROM displayed at pow er ON
    
    08-903: Engine ROM version 
     
    08-905: Scanner ROM version
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 38
    [C] Display during the update 
    Update is performed in parallel as shown in the tra nsition diagram below. 
    Below is an example of the changes of the LCD scree n during update. 
    Note that the screen order may be different from th e actual one, because a parallel update is performe d 
    in the process. 
    Select items to be updated and press the  
    [START] button to start updating the 
    [System ROM], [Engine ROM] and  
    [Scanner ROM] in parallel. 
    Item Selection Screen for Update
    0. OS Update
    1. UI Data Update
    2. System Firmware Update
    ¦ System ROM §
    Update Completed¦Engine ROM §
    4. Scanner Firmware Update¦Scanner ROM §
    3. Engine Firmware Update
    Turn ON the power while [8] button and [9] button are pressed simultaneously
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 39
    6
    When the [System ROM]-[OS Update] has  
    been updated, “OS Update…Completed” is 
    displayed and the [UI Update] update will start.  
    When the [System ROM]-[UI Update] has been  
    updated, “UI Data Update…Completed” is dis- 
    played and the [System Firmware Update] 
    update will start. 
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 40
    When the [Engine ROM] has been updated,  
    “Engine MAIN Update..Flash Update” is 
    changed to “Engine MAIN Update..Com-
    pleted”.  
    When the [System ROM]-[System Firmware  
    Update] has been updated, “SysFirm  
    Update…Completed” is displayed.  
    When the [Scanner ROM] has been updated,  
    “Scanner Firm Update..Flash Update” is 
    changed to “Scanner Firm Update..Com- 
    pleted”.  
    When all data has been updated, “Update  
    Completed” is displayed. 
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 41
    6
    * “Update Failed.” is displayed at the bottom of the  LCD screen when the updating is not completed 
    properly. “Failed” appears next to the failed item  on the status display. 
    Failed items Error message
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 42
    6.2.2 Writing the data to the download jig (PWA-DWNL
    D-350-JIG)
    The download jig (PWA-DWNLD-350-JIG) is the jig in which the Flash ROM is mounted on the board 
    directly. The ROM writer adapter (PWA-DL-ADP-350) i s required to write data to these Flash ROMs. 
    Connect the download jig with the ROM writer via RO M writer adapter to write data. For the procedure 
    to write data, refer to the download procedure, ins truction manual of each ROM writer, or others.
     Fig.6-38
    Note: Note: 
    There are two types of the ROM writer adapter. Use  the proper one according to the ROM writer 
    to be used. Applicable type of the adapter for the  ROM writer can be confirmed by the model 
    name indicated on the board. Confirm that the adapt er is available for the ROM writer to be used 
    before connecting them. If an unapplied adapter is  connected, the application of the ROM writer 
    judges it as an error and writing the data cannot b e implemented. Applicable combinations of the 
    ROM writer and adapter are as follows.
    ROM writer ROM writer adapter
    Minato Electronics MODEL 1881XP  
    (or equivalent) PWA-DL-ADP-350-1881 (model 1881)
    Minato Electronics MODEL 1893/1895/1931/1940 
     (or equivalent) PWA-DL-ADP-350-1931 (model 1931)
     Fig.6-39 PWA-DL-ADP-350-1881  Fig.6-40 PWA-DL-ADP-3 50-1931
    PC
    Download jig (
    PWA-DWNLD-350-JIG )
    ROM writer ROM writer adapter(
    PWA-DL-ADP-350 )
    model   1881
    [
    PWA-DL-ADP-350-1881 ]
    model   1931
    ( LV650 )
    [
    PWA-DL-ADP-350-1931 ]
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 43
    6
     Precaution when writing the data - Set the writing voltage (VID) to 3.3 V. 
    - When writing the data, set the address from 0 to 3 FFFFF. The data may not be written correctly if 
    it is not set.
    - The Flash ROM in which the data will be written, o n the download jig is selected by switching the 
    rotary switch on the adapter. Be sure to switch the  rotary switch on the adapter depending on the 
    data (file) to be written.
    Note: Note:  Be sure not to confuse different ROM Versions since  the file name is identical although the ROM 
    version is different.
    RotarySwitch File Name Flash ROM
    1 firmImage 0.bin ROM1 
    2 firmImage 1.bin ROM2
    3 firmImage 2.bin ROM3
    4 N/A ROM4 
    5 N/A ROM5 
    6 N/A ROM6
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 44
    6.2.3 K-PWA-DLM-320
    The firmware of the equipment (engine ROM, scanner 
    ROM) and the option (RADF ROM, Finisher 
    ROM, FAX ROM) can be updated individually by using  K-PWA-DLM-320. Update the ROM data written 
    on each board according to the need such as the cas e of replacing the board.
    The data to be overwritten by this update are as fol lows.
     Engine ROM data
     Scanner ROM data
     RADF ROM data
     Finisher ROM data
     FAX ROM data
    [A] Update Procedure 
    Since the procedure differs depending on the data,  see the each procedure below.
    Important: 
     Turn OFF the power before installing or removing t he download jig.
     Do not turn OFF the power during the update. The d ata could be damaged and not be oper-
    ated properly.
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 45
    6
    
    (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5).
    (2) Turn OFF the power of the equipment. 
    (3) Take off the connector cover.
     Fig.6-41
    (4) Remove the cover plate.
     Fig.6-42
    Connector cover
    Cover plate
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 46
    (5) Connect the download jig with the jig connector ( CN316) on the logic PC board (LGC board).
     Fig.6-43
    (6) Turn ON the power while [0] button and [8] button are pressed simultaneously.
    Updating starts automatically and the LED on the dow nload jig lights.
    (7) When the update is completed properly, the LED o n the download jig blinks. The LED starts 
    blinking in approx. 20 sec. since the update starts.  It is assumed that the update is failed if it does 
    not start blinking even though 1 min. has passed. I n this case, turn OFF the power and check the 
    following items. Then, clear the problem and restar t updating from the beginning.
     Is the download jig connected properly? 
     Is the ROM installed to the download jig properly? 
     Is the updating data written on the ROM of the dow nload jig properly?
     Do the download jig and the equipment operate prop erly?
    (8) Turn OFF the power, remove the download jig and  install the cover plate and the connector 
    cover.
    Connector