    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 55
    3
    (7) Tighten the positioning pin at the front side. Close the RADF to fit the positioning pin into  
    the hole at the front side of the RADF. (For 
    the front side, adjust the RADF position all  
    around.)
     Fig.3-56
    (8) While peering inside from the left side, close the RADF. Check the positions of the holes  
    of the RADF and pins and then fit their posi- 
    tions by moving the RADF back and forth.  
    (For the front side, also adjust the RADF  
    position right and left.) Make sure not to dis- 
    locate the positions of the pin and hole at the  
    rear side.
     Fig.3-57
    (9) Open the RADF to tighten 2 hand screws.
    Close the RADF and then check again that 
    the positioning pins fit smoothly into the  
    holes on the RADF.
     Fig.3-58 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 56
    (10) Match the rear hole of the right-hand hinge  and the hole of the equipment side to tighten  
    the stepped screw. If they do not fit, adjust 
    the position of the hole by turning the screw  
    of the adjustment plate.
     Fig.3-59
    (11) Tighten the stepped screw and 2 screws on the adjustment plate. 
    Open and close the RADF to check again  
    that the positioning pins fit smoothly into the  
    holes on the RADF. Remove the positioning  
    pins after checking it. 
    (Replace the positioning pins at the rear of  
    the right-hand hinge of the RADF.)
     Fig.3-60
    (12) Place the platen sheet on the original glass 
    with the semi round cutout toward you.
    Align the platen sheet against the left and  
    rear side of the original glass. Close the  
    RADF slowly. Open the RADF to check that  
    the platen sheet is correctly attached.
     Fig.3-61
    Screw of the adjustment plate
    Stepped screw Screw 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 57
    3
    3.10.2 Adjustment of RADF height
    It is mainly performed at the installation. It is a lso required when the RADF is dislocated for some re a-
    son such as moving the equipment. 
    Perform the following adjustment by using the screw o f the left and right hinge.
    Note: Note: 
    Perform this adjustment after “3.10.1 Adjustment of  RADF position”.
    Turn the exposure lamp ON during the gap check. (Te st Mode: 03-267)
    
    (1) Adjustment standard: Adjust the height so that the platen guide front ho lder touches the ADF original glass.
    Adjust the height so that the gap between the plate n guide rear holder and the ADF original glass 
    becomes 0.5 mm ± 0.3.
     Fig.3-62
    (2) Adjust the height by turning the height  adjusting screw on the right hinge. 
    CW: The height of the hinge becomes high. 
    CCW: The height of the hinge becomes low.
     Fig.3-63
    0.5mm±0.30mm
    Platen guide 
    rear holder
    ADF original glassPlaten guide 
    front holder 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 58
    (3) Adjust the height by turning the height  adjusting screw on the left hinge. 
    CW: The height of the hinge becomes high.
    CCW: The height of the hinge becomes low.
     Fig.3-64 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 59
    3
    3.10.3 Adjustment of skew
    When an image skew occurs, adjust it according to th e following steps, Step 1  Step 2   Step 3.
    Note: Note: 
    Perform this adjustment after confirming that the e quipment has been adjusted properly.
    Prior to this adjustment, of RADF position and heig ht are needed to be adjusted.
    (1) Step 1 
    Case A:  
    Adjust the aligning adjustment position to the rear  side “-” of the original ( P.3-62 3.10.5 
    Adjustment of aligning). 
    Case B:  
    Adjust the aligning adjustment position to the rear  side “+” of the original ( P.3-62 3.10.5 
    Adjustment of aligning).
     Fig.3-65
    A B
    Paper
    Original
    White arrow: feeding direction 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 60
    (2) Step 2 
    Case C: 
    Loosen the fixing screw and hand screw of the right  side hinge and then turn the adjustment 
    screw counterclockwise.
    Case D: 
    Loosen the fixing screw and hand screw of the right  side hinge and then turn the adjustment 
    screw clockwise.
    Note: Note:  When adjusting, refer to the hinge position (scribe d line) and be sure not to move it from the 
    hinge position ±0.5 mm or further. Otherwise, image  failures such as a jitter may occur.
    (3) Step 3 
    Case E:  
    Adjust the reverse aligning adjustment position to  the rear side “-” of the original ( P.3-63 
    3.10.6 Adjustment of aligning at reversing). 
    Case F: 
    Adjust the reverse aligning adjustment position to  the rear side “+” of the original ( P.3-63 
    3.10.6 Adjustment of aligning at reversing).
     Fig.3-68
     Fig.3-66
     Fig.3-67
    C D
    Paper
    Original
    Fixing screw
    Adjustment screw Hand screw
    RADF
    ã Front side
    E F
    Paper
    Original 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 61
    3
    3.10.4 Automatic adjustment of sensors and initializ ation of EEPROM
    When any of the PC board, original length sensor, read sensor, reverse sensor is replaced with a new 
    one, make sure to perform the initialization of EEP ROM and adjustment of sensors in the Adjustment 
    Mode (05). 
    Perform them after removing all originals on the se nsor and closing the RADF.
    Also, make sure to adjust the tray volume when the  initialization of EEPROM and automatic sensor 
    adjustment have been performed.
    Refer to   P.2-43 2.2.5 Adjustment mode (05) (e-STUDIO200L/2 30/280) for the details.
    Errors such as paper jamming may occur if the EEPRO M is not initialized and the sensors are not 
    adjusted after the above mentioned parts were repla ced.
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 62
    3.10.5 Adjustment of aligning
    Adjust the aligning according to Step 1 of 3.10.3.
     Fig.3-69
    -  Rear side - of the original
    Skew of paper
    Rear side + of the original  + 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 63
    3
    3.10.6 Adjustment of aligning at reversing
    Adjust the aligning according to Step 3 of 3.10.3.
     Fig.3-70
    Screw of pape r 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 64
    3.10.7 Adjustment of reverse solenoid
    When operating the reverse solenoid, adjust it if t
    he position of the flapper lever is out of the following 
    dimension. 
    Gap between A of the front frame and the flapper le ver “C”: 0.5 mm to 2.0 mm
    
    (1) Remove the screw on the left and take off the  plate spring.
     Fig.3-71
    (2) Align B of the front frame with the edge of the  reverse solenoid, and temporarily fix the  
    reverse solenoid with the screw on the right.
     Fig.3-72
    (3) While the plunger of the reverse solenoid is put in the position to be turned ON (by press- 
    ing it in the direction of an arrow), loosen the 
    screw on the right to adjust the reverse sole-
    noid so that the gap (C) between A of the 
    front frame and the flapper lever is 0.5 mm to 
    2.0 mm.
     Fig.3-73
    Plate spring
    B
    C A 
    						