Toshiba Estudio 230 Manual
Have a look at the manual Toshiba Estudio 230 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT 7 - 1 7 7. POWER SUPPLY UNIT 7.1 Output Channel The followings are five output channels which are n ot linked with the door switch. 1) +3.3V +3.3VA : CN705 Pins 13, 14, 15 and 16 Output to the SYS board +3.3VB : CN705 Pins 19 and 20 Output to the SYS board +3.3VB : CN706 Pin 30 Output to the LGC board +3.3VB : CN708 Pins 9 and 10 Output to the SLG board 2) +5.1V +5.1VA : CN705 Pins 24 and 26 Output to the SYS board +5.1VB : CN705 Pin 25 Output to the SYS board +5.1VB : CN706 Pin 26 Output to the FUS board +5.1VB : CN706 Pins 27 and 28 Output to the LGC board, PFP/ LCF (via LGC board), Bridge unit / Job separator / Offset tray (via LGC board) +5.1VB : CN707 Pin 4 Output to the finisher +5.1VB : CN708 Pins 3 and 4 Output to the SLG board +5.1VB : CN708 Pins 5 and 6 Output to the RADF 3) +12V +12VA : CN705 Pin 7 Output to the SYS board +12VB : CN705 Pin 5 Output to the SYS board +12VB : CN706 Pin 22 Output to the LGC board +12VB : CN708 Pin 13 Output to the SLG board 4) -12V -12VA : CN705 Pin 9 Output to the SYS board -12VB : CN705 Pin 3 Output to the SYS board 5) +24V +24VB : Not used
e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC 7 - 2 The followings are two output channels which are li nked with the door switch. 1) +5.1V +5.1VD : CN706 Pin 2 Output to the LGC board 2) +24V +24VD1 : CN706 Pins 11, 12, 13 and 14 Output to the LGC board, PFP/LCF (via LGC board) +24VD1 : CN707 Pins 15 and 16 Output to the main motor +24VD2 : CN706 Pins 5 and 6 Output to the LGC board, High-voltage transformer ( via LGC board), Bridge unit / Job separator / Offset tray (via LGC board) +24VD2 : CN707 Pins 11 and 12 Output to the ADU board +24VD3 : CN708 Pins 23 and 24 Output to the RADF +24VD4 : CN708 Pins 19 and 20 Output to the SLG board +24VD5 : CN707 Pin 8 Output to the finisher Not linked with the door switch Linked with the door switch Connector Destination Voltage CN705 For the SYS board +3.3VA, +3.3VB, +5.1VA, +5.1V B, +12VA, +12VB, -12VA, -12VB CN706 For the LGC board, FUS board, PFP/LCF (via LGC board), Bridge unit / Job separator / Offset tray ( via LGC board) +3.3VB, +5.1VB, +12VB CN707 For the finisher +5.1VB CN708 For the SLG board, RADF +3.3VB, +5.1VB, +12VB Connector Destination Voltage CN706 For the LGC board, High-voltage transformer (v ia LGC board), PFP/LCF (via LGC board), Bridge unit / Job separator / Offset tray (via LGC board) +5.1VD, +24VD1, +24VD2 CN707 For the ADU board, finisher +24VD1, +24VD2, +24 VD5 CN708 For the SLG board, RADF +24VD3, +24VD4
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT 7 - 3 7 7.2 Fuse When the power supply secondary fuse is blown out, confirm that there is no abnormality with each part using the following table. Voltage Board/Unit Part Fuse type +24VD1 LGC Main motor F4:8A (Semi time-lag) Toner motor Polygonal motor Tray-up motor Internal cooling fan 1 Internal cooling fan 2 Auto-toner sensor Upper drawer feed clutch Lower drawer feed clutch Registration roller clutch Upper transport clutch Middle transport clutch Lower transport clutch Discharge LED Main switch PFP/LCF +24VD2 LGC Exit motor F5:5A (Semi time-lag) ADU motor Exhaust fan Bypass feed clutch ADU clutch Bypass pickup solenoid High-voltage transformer Key copy counter / Copy key card Bridge unit / Job separator / Offset tray +24VD3 RADF F6:4A (Semi time-lag) +24VD4 SLG Scan motor F7:4A (Semi time-lag) Exposure lamp (Lamp inverter) +24VD5 Finisher F8:5A (Semi time-lag)
e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC 7 - 4 7.3 Configuration of Power Supply Unit Fig.7-1 PWR-DN PWR-EN +3.3VA +3.3VB +3.3VB +3.3VB +5.1VA +5.1VB +5.1VBCN705 CN705 CN706 CN708 CN705 CN705 CN706 +5.1VB CN707 SYS board SYS board SYS board, LGC board SYS board LGC board SLG board SYS board SYS board SLG board, RADF +5.1VB CN708Finisher +12VA CN705 SYS board SYS board SYS board LGC board SLG board SYS board -12VA CN705 +12VB CN705 +12VB CN706 +12VB CN708 -12VB CN705 +24VB Not used LGC board LGC board LGC board ADU board LGC board, High-voltage transformer ( via LGC board ), Bridge unit / Job separator /Offset tray ( via LGC board ) +5.1VD CN706 LGC board, PFP/LCF ( via LGC board ) +24VD1 +24VD2 CN706 CN706 Main motor +24VD1 CN707 +24VD2 CN707SYS board, FUS board, PFP/LCF ( via LGC board ) , Bridge unit / Job separator / Offset tray ( via LGC board ) CN705 CN705,CN706 Regulator Regulator F4 RADF +24VD3 CN708 F6 SLG board +24VD4 CN708 F7 F2 F1 Finisher +24VD5 CN707 HTR1ON CN706 HTR2ON CN706 F8 F5 Side heater lamp control circuit (TRC2 ) Center heater lamp control circuit(TRC1 ) Main switch Cover opening/closing interlock switch Fuser center thermostat Live Neutral Switching regulator Fuser front thermostat CN703 CN704 CN702 CN701 Noise filter Noise filter Center heater lamp Side heater lamp FUS board Damp heaters RY NAD/MJD models: Option Other models: Standard 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 1 8 8. REMOTE SERVICE There are following functions as Remote Service. 1) Auto Supply Order Automatically orders the toner by FAX or E-mail. 2) Service Notification Notifies the status of the equipment to the service technician by E-mail or FAX. 8.1 Auto Supply Order 8.1.1 Outline Automatically orders the toner. 1) Placing an Order There are two ways to place an order. - FAXInstallation of the FAX board is required. If the FAX board has not been installed, it is rega rded as OFF setting. - E-mail (E-mail body + TIFF image) 2) Order Intervals When the toner empty occurs, the number of occurrenc es is counted. And when it reaches the spec- ified number for CONDITION, the order is placed aut omatically. 3) If Order Failure Occurs If some problems occur and the order cannot be place d after registering an order as a job, refer to the standard countermeasure for the FAX/E-mail tran smission failure. 05/05
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 2 8.1.2 Setting Item To enable Auto Supply Order, the following settings are required. Note: Note: When selecting E-mail to place an order, it is requ ired that sending and receiving E-mails are available. Confirm the details to the administrator . 1) Self-diagnosis (08) Setting As the default setting, the Auto Supply Order setti ng screen is not displayed on the touch panel. To display it, switching the Valid/Invalid setting (08-765) is required. 0: Valid (FAX/Internet FAX) 1: Valid (FAX/Internet FAX/HTTP)* 2: Invalid (Default) When changing the setting value from “2” (default) to “0”, the Auto Supply Order setting screen is displayed. (* HTTP has not been supported yet.)
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 3 8 2) Touch Panel Setting Each item is set from the Auto Supply Order screen on the touch panel. Entering the password and customer information is r equired because the setting is made from the ADMIN screen. Setting it with the administrator is a must. - Basic setting [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [ORDER INFORMATION] *1 HTTP has not been supported yet. *2 Even when “FAX” is selected, the order is not pl aced without entering the FAX number. *3 Even when “MAIL” is selected, the order is not p laced without entering the E-mail address. AUTO SUPPLY ORDER Ordered by: [FAX], [MAIL], [HTTP] (*1) FAX NUMBER FAX number of supplier (*2) E-MAIL E-mail address of supplier (*3) CUSTOMER Customer information NAME TEL NUMBER E-MAIL ADDRESS SUPPLIER Supplier information NAME ADDRESS SERVICE TECHNICIAN Service technician information NUMBER NAME TEL NUMBER E-MAIL
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 4 - Detailed setting for the order [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [TONER ORDERING] *1 The order is placed when the number of replaceme nt reaches the number specified for the CONDITION. - FAX number of this equipment (common information) [ADMIN] > [FAX] > [TERMINAL ID] - E-mail information of this equipment (common inform ation) [ADMIN] > [E-MAIL] *1 When sending an E-mail, validity of the address is checked. If the address is invalid, it is not sent. 3) Output of setting list of the Auto Supply Order Keying in the following buttons and keys prints the setting list. [USER FUNCTIONS] [USER] [LISTS] [*] [#] [*] [*] [3] [8] [START] ***** TONER ORDER Order information (TONER) PART NUMBER Part number to be ordered CONDITION The number of conditions (*1) QUANTITY The quantity to be ordered AUTO ORDER ON/OFF setting of order for each part ID NAME ID name of this equipment FAX NUMBER FAX number of this equipment FROM ADDRESS E-mail address of this equipment (*1) FROM NAME E-mail username of this equipment
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE 8 - 5 8 8.1.3 Setting procedure (1) Start up the self-diagnosis setting mode 08-765, and then change the setting value to “0”. (2) Turn the power OFF, and then ON. (3) Press the [USER FUNCTIONS] button to enter the user function screen. (4) Press the [ADMIN] button. When the Administrator Password has been set, ADMI NISTRATOR PASSWORD screen is displayed. Fig.8-1 (5) Press the [PASSWORD] button and the screen is sw itched to a full keyboard. Then key in the Administrator Password and press the [ENTER] button . * Confirm the password to the administrator. Fig.8-2 (6) Press the [SERVICE] button in the ADMIN screen. 05/05
e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC 8 - 6 (7) The SERVICE screen is displayed. Fig.8-3 (8) Press the [SUPPLY ORDER SETUP] button. Fig.8-4 (9) Press the [ORDER INFORMATION] button. (10) The ORDER INFORMATION screen is displayed. Fig.8-5