    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT
    7 - 1
    7
    7. POWER SUPPLY UNIT 
    7.1 Output Channel
    The followings are five output channels which are n ot linked with the door switch.
    1) +3.3V +3.3VA : CN705 Pins 13, 14, 15 and 16 Output to the SYS board
    +3.3VB : CN705 Pins 19 and 20
    Output to the SYS board
    +3.3VB : CN706 Pin 30 Output to the LGC board
    +3.3VB : CN708 Pins 9 and 10 Output to the SLG board
    2) +5.1V +5.1VA : CN705 Pins 24 and 26
    Output to the SYS board
    +5.1VB : CN705 Pin 25
    Output to the SYS board
    +5.1VB : CN706 Pin 26
    Output to the FUS board
    +5.1VB : CN706 Pins 27 and 28 Output to the LGC board, PFP/ LCF (via LGC board), 
    Bridge unit / Job separator / Offset tray (via LGC  board)
    +5.1VB : CN707 Pin 4 Output to the finisher
    +5.1VB : CN708 Pins 3 and 4 Output to the SLG board
    +5.1VB : CN708 Pins 5 and 6
    Output to the RADF
    3) +12V +12VA : CN705 Pin 7 Output to the SYS board
    +12VB : CN705 Pin 5 Output to the SYS board
    +12VB : CN706 Pin 22 Output to the LGC board
    +12VB : CN708 Pin 13 Output to the SLG board
    4) -12V -12VA : CN705 Pin 9 Output to the SYS board
    -12VB : CN705 Pin 3
    Output to the SYS board
    5) +24V +24VB : Not used 
    						
    							e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC
    7 - 2
    The followings are two output channels which are li nked with the door switch.
    1) +5.1V +5.1VD : CN706 Pin 2 Output to the LGC board
    2) +24V +24VD1 : CN706 Pins 11, 12, 13 and 14 Output to the LGC board, PFP/LCF (via LGC board)
    +24VD1 : CN707 Pins 15 and 16 Output to the main motor
    +24VD2 : CN706 Pins 5 and 6 Output to the LGC board, High-voltage transformer ( via LGC board),
    Bridge unit / Job separator / Offset tray (via LGC  board)
    +24VD2 : CN707 Pins 11 and 12 Output to the ADU board
    +24VD3 : CN708 Pins 23 and 24 Output to the RADF
    +24VD4 : CN708 Pins 19 and 20
    Output to the SLG board
    +24VD5 : CN707 Pin 8 Output to the finisher
     
    Not linked with the door switch 
    Linked with the door switch
    Connector Destination Voltage
    CN705 For the SYS board +3.3VA, +3.3VB, +5.1VA, +5.1V B, 
    +12VA, +12VB, -12VA, -12VB
    CN706 For the LGC board, FUS board, PFP/LCF (via LGC  
    board), Bridge unit / Job separator / Offset tray ( via 
    LGC board) +3.3VB, +5.1VB, +12VB
    CN707 For the finisher +5.1VB
    CN708 For the SLG board, RADF +3.3VB, +5.1VB, +12VB
    Connector Destination Voltage
    CN706 For the LGC board, High-voltage transformer (v ia 
    LGC board), PFP/LCF (via LGC board), Bridge unit /  
    Job separator / Offset tray (via LGC board) +5.1VD, +24VD1, +24VD2
    CN707 For the ADU board, finisher +24VD1, +24VD2, +24 VD5
    CN708 For the SLG board, RADF +24VD3, +24VD4 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT
    7 - 3
    7
    7.2 Fuse
    When the power supply secondary fuse is blown out,  confirm that there is no abnormality with each part 
    using the following table.
    Voltage Board/Unit Part Fuse type
    +24VD1 LGC Main motor F4:8A (Semi time-lag)
    Toner motor 
    Polygonal motor
    Tray-up motor
    Internal cooling fan 1
    Internal cooling fan 2
    Auto-toner sensor
    Upper drawer feed clutch
    Lower drawer feed clutch
    Registration roller clutch
    Upper transport clutch
    Middle transport clutch
    Lower transport clutch
    Discharge LED
    Main switch
    PFP/LCF
    +24VD2 LGC Exit motor F5:5A (Semi time-lag)
    ADU motor
    Exhaust fan
    Bypass feed clutch
    ADU clutch
    Bypass pickup solenoid
    High-voltage transformer
    Key copy counter / Copy key card
    Bridge unit / Job separator / Offset tray
    +24VD3 RADF F6:4A (Semi time-lag)
    +24VD4 SLG Scan motor F7:4A (Semi time-lag)
    Exposure lamp (Lamp inverter)
    +24VD5 Finisher F8:5A (Semi time-lag) 
    						
    							e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNITJune 2004 © TOSHIBA TEC
    7 - 4
    7.3 Configuration of Power Supply Unit
     Fig.7-1
    PWR-DN 
    PWR-EN
    +3.3VA 
    +3.3VB
    +3.3VB
    +3.3VB
    +5.1VA 
    +5.1VB 
    +5.1VBCN705 
    CN705
    CN706
    CN708
    CN705
    CN705 
    CN706
    +5.1VB CN707 SYS board
    SYS board
    SYS board, LGC board
    SYS board
    LGC board 
    SLG board
    SYS board
    SYS board 
    SLG board, RADF
    +5.1VB CN708Finisher
    +12VA CN705 SYS board 
    SYS board 
    SYS board 
    LGC board 
    SLG board 
    SYS board
    -12VA
    CN705
    +12VB CN705
    +12VB CN706
    +12VB CN708
    -12VB CN705
    +24VB Not used
    LGC board 
    LGC board 
    LGC board
    ADU board
    LGC board, High-voltage transformer 
    (
    via LGC board ), 
    Bridge unit / Job separator /Offset tray  (
    via LGC board )
    +5.1VD
    CN706
    LGC board, PFP/LCF  (
    via LGC board )
    +24VD1 
    +24VD2 CN706 
    CN706
    Main motor
    +24VD1
    CN707
    +24VD2 CN707SYS board, FUS board, PFP/LCF 
    (
    via LGC board )
    ,
    Bridge unit / Job separator / Offset tray  (
    via LGC board )
    CN705
    CN705,CN706
    Regulator
    Regulator
    F4
    RADF
    +24VD3
    CN708
    F6
    SLG board
    +24VD4
    CN708
    F7
    F2
    F1
    Finisher
    +24VD5
    CN707
    HTR1ON CN706
    HTR2ON CN706
    F8
    F5
    Side heater lamp
    control circuit (TRC2 )
    Center heater lamp
    control circuit(TRC1 )
    Main
    switch Cover opening/closing 
    interlock switch
    Fuser center
    thermostat
    Live
    Neutral
    Switching regulator
    Fuser front
    thermostat
    CN703
    CN704
    CN702
    CN701
    Noise filter
    Noise filter
    Center heater lamp Side heater lamp FUS board
    Damp
    heaters
    RY
    NAD/MJD models: Option 
    Other models: Standard
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE
    8 - 1
    8
    8. REMOTE SERVICE
    There are following functions as Remote Service. 
    1) Auto Supply Order Automatically orders the toner by FAX or E-mail.
    2) Service Notification Notifies the status of the equipment to the service  technician by E-mail or FAX.
    8.1 Auto Supply Order 
    8.1.1 Outline
    Automatically orders the toner. 
    1) Placing an Order
    There are two ways to place an order. 
    - FAXInstallation of the FAX board is required. 
    If the FAX board has not been installed, it is rega rded as OFF setting.
    - E-mail (E-mail body + TIFF image)
    2) Order Intervals When the toner empty occurs, the number of occurrenc es is counted. And when it reaches the spec-
    ified number for CONDITION, the order is placed aut omatically.
    3) If Order Failure Occurs If some problems occur and the order cannot be place d after registering an order as a job, refer to 
    the standard countermeasure for the FAX/E-mail tran smission failure.
    05/05 
    						
    							e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC
    8 - 2
    8.1.2 Setting Item
    To enable Auto Supply Order, the following settings 
    are required.
    Note: Note: 
    When selecting E-mail to place an order, it is requ ired that sending and receiving E-mails are 
    available. Confirm the details to the administrator .
    1) Self-diagnosis (08) Setting As the default setting, the Auto Supply Order setti ng screen is not displayed on the touch panel.
    To display it, switching the Valid/Invalid setting  (08-765) is required.
    0: Valid (FAX/Internet FAX) 
    1: Valid (FAX/Internet FAX/HTTP)*
    2: Invalid (Default)
    When changing the setting value from “2” (default)  to “0”, the Auto Supply Order setting screen is 
    displayed. (* HTTP has not been supported yet.) 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE
    8 - 3
    8
    2) Touch Panel Setting Each item is set from the Auto Supply Order screen  on the touch panel.
    Entering the password and customer information is r equired because the setting is made from the 
    ADMIN screen. Setting it with the administrator is  a must.
    - Basic setting [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [ORDER  INFORMATION]
    *1 HTTP has not been supported yet. 
    *2 Even when “FAX” is selected, the order is not pl aced without entering the FAX number.
    *3 Even when “MAIL” is selected, the order is not p laced without entering the E-mail address.
    AUTO SUPPLY ORDER Ordered by: [FAX], [MAIL], [HTTP]  (*1)
    FAX NUMBER FAX number of supplier (*2) 
    E-MAIL E-mail address of supplier (*3)
    CUSTOMER Customer information NAME
    TEL NUMBER
    E-MAIL
    ADDRESS
    SUPPLIER Supplier information NAME 
    ADDRESS
    SERVICE TECHNICIAN Service technician information
    NUMBER 
    NAME
    TEL NUMBER
    E-MAIL 
    						
    							e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC
    8 - 4
    - Detailed setting for the order [ADMIN] > [SERVICE] > [SUPPLY ORDER SETUP] > [TONER  ORDERING]
    *1 The order is placed when the number of replaceme nt reaches the number specified for the 
    CONDITION.
    - FAX number of this equipment (common information) [ADMIN] > [FAX] > [TERMINAL ID]
    - E-mail information of this equipment (common inform ation)
    [ADMIN] > [E-MAIL] 
    *1 When sending an E-mail, validity of the address  is checked. If the address is invalid, it is not 
    sent.
    3) Output of setting list of the Auto Supply Order Keying in the following buttons and keys prints the  setting list.
    [USER FUNCTIONS] [USER] [LISTS] [*] [#] [*] [*] [3]  [8] [START]
    ***** TONER ORDER Order information (TONER) 
    PART NUMBER Part number to be ordered
    CONDITION The number of conditions (*1)
    QUANTITY The quantity to be ordered
    AUTO ORDER ON/OFF setting of order for each part 
    ID NAME ID name of this equipment 
    FAX NUMBER FAX number of this equipment 
    FROM ADDRESS E-mail address of this equipment (*1) 
    FROM NAME E-mail username of this equipment 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 REMOTE SERVICE
    8 - 5
    8
    8.1.3 Setting procedure
    (1) Start up the self-diagnosis setting mode 08-765,  and then change the setting value to “0”.
    (2) Turn the power OFF, and then ON. 
    (3) Press the [USER FUNCTIONS] button to enter the user  function screen.
    (4) Press the [ADMIN] button.  When the Administrator Password has been set, ADMI NISTRATOR PASSWORD screen is 
    displayed.
     Fig.8-1
    (5) Press the [PASSWORD] button and the screen is sw itched to a full keyboard. Then key in the 
    Administrator Password and press the [ENTER] button .
    * Confirm the password to the administrator.
     Fig.8-2
    (6) Press the [SERVICE] button in the ADMIN screen.
    05/05   
    						
    							e-STUDIO200L/202L/230/232/280/282 REMOTE SERVICEJune 2004 © TOSHIBA TEC
    8 - 6
    (7) The SERVICE screen is displayed.
     Fig.8-3
    (8) Press the [SUPPLY ORDER SETUP] button.
     Fig.8-4
    (9) Press the [ORDER INFORMATION] button. 
    (10) The ORDER INFORMATION screen is displayed.
     Fig.8-5    
    						
    All Toshiba manuals Comments (0)