June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 45 3 (3) After winding the wires around the pulleys, atta ch the wire holder jigs not to loosen the wires. Notes: When the wire holder jig is attached, make sure th at the wire is not shifted or loosened. The wire should come out of the slot of the wire h older jig and be passed through between the arm and the jig. Fig.3-34 Arm Wire holder jig
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 46 3.7.2 Lens unit [A] Replacing the lens unit The lens unit must not be readjusted and some part of its components must not be replaced in the field since the unit is precisely adjusted. If any of the components is defective, replace the whole unit. When replacing the unit, do not loosen or remove t he 4 screws indicated with the arrows. Fig.3-35 Handle the unit with care. Do not hold the lens and adjusted part (hold the unit as shown below). Fig.3-36
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 47 3 [B] Adjustment of the magnification ratio of the lens Notes: Perform this adjustment only when the lens unit is taken off or replaced. Make sure that the primary scanning reproduction r atio (printer section) is correct before this adjustment. (1) Place a ruler on the original glass (in the prim ary scanning direction) and make a copy on A4/LT- sized paper at 100% reproduction ratio. (3) If each mark on the rulers differs, perform the adjustment with the following procedures. (2) Compare the copied ruler with the actual ruler. Fig.3-37 (1) Take off the original glass and lens cover. (2) Loosen 2 screws fixing the lens unit. Fig.3-38 Feeding Direction Actual ruler Copied ruler Lens unit Screw
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 48 (3) Slide the lens unit to the right or left directi on using the marks on the lens base as a guide. (Sl ide right when the copied ruler is magnified and slide left when the copied ruler is demagnified.) The following table shows how the reproduction rati o difference between the copied ruler and actual ruler corresponds to the movement amount of the lens unit. Fig.3-39 Note: Note: Fine adjustment can be made in the “Reproduction ra tio of primary scanning direction (printer)”. on the copied ruler and actual ruler match. (4) Tighten 2 screws fixing the lens unit. (5) Attach the lens cover and original glass. Make a copy to confirm the reproduction ratio. (6) Repeat the procedure 1 to 5 until the marks on t he copied ruler and actual ruler match. Reproduction-ratio error Movement amount of unit 0.1% 0.5 mm 0.2% 0.9 mm 0.3% 1.4 mm 0.4% 1.8 mm 0.5% 2.3 mm 0.6% 2.7 mm 0.7% 3.2 mm 0.8% 3.6 mm 0.9% 4.1 mm 1.0% 4.5 mm Lens unit
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 49 3 3.8 Adjustment of the Paper Feeding System 3.8.1 Sheet sideways deviation caused by paper feedi ng The center of the printed image shifts to the front side. Move the guide to the front side (Arrow (A) direction in the lower figure). The center of the printed image shifts to the rear side. Move the guide to the rear side (Arrow (B) direction in the lower figure). Fig.3-40 Fig.3-41 Bypass feeding 1) Loosen the screen. 2) Move the entire guide to the front or rear side. 3) Tighten the screw.Drawer feeding 1) Loosen 2 screws. 2) Move the entire guide to the front or rear side. 3) Tighten the screws. Fig.3-42 Fig.3-43 Feeding direction Center [Rear] [Front]Feeding direction Center [Rear] [Front] (A) (B) ( B ) ( A ) 05/07
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 50 3.9 Adjustment of Developer Unit 3.9.1 Doctor-to-sleeve gap Adjustment tool to use: Doctor-sleeve jig (1) Perform the adjustment code “05-280”. (2) Take out the process unit from the equipment. (3) Take out the developer unit from the process uni t. (4) Remove 2 screws and take off the developer material cover and discharge the developer material. Note: Note: Discharge the developer material from the rear side, being careful not to let it be scat- tered on the gear. Fig.3-44 (5) Turn the adjustment screw to widen the gap so that the jig can be inserted in it. (Turning the screw clockwise widens the gap) Fig.3-45 Developer material cover Screw
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 51 3 (6) Insert the gauge with the thickness “0.45” of the doctor sleeve jig into the gap between the developer sleeve and doctor blade after lifting up the toner scattering prevention sheet. Adjust the screws with the doctor blade to push the doctor sleeve jig lightly. Fig.3-46 (7) Insert the gauge “0.40” of the doctor sleeve jig into the gap between the developer sleeve and doctor blade. Confirm that the jig moves smoothly to the front and rear side, and the gauge “0.50” cannot be inserted into the gap. Fig.3-47 (8) Confirm that the side seals are attached on the toner scattering prevention sheet. Fig.3-48 ScrewDoctor sleeve jig Toner scattering prevention sheet Developer sleeve Doctor sleeve jig Side seal Toner scattering prevention sheet
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 52 (9) Attach the developer material cover and tighten 2 screws. Note: Note: After the developer material has been replaced, adjust the auto-toner sensor. (See P.3-1 3.1 Adjustment of Auto-Toner Sensor.) Fig.3-49 Developer material cover
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT 3 - 53 3 3.10 Adjustment of the RADF (MR-3016) 3.10.1 Adjustment of RADF position It is mainly performed at the installation. It is a lso required when the RADF is dislocated for some re a- son such as moving the equipment. Remove the platen sheet during adjustment. (1) Open the RADF and then attach 2 position- ing pins to the equipment. (The positioning pins have been attached at the rear of the right-hand hinge of the RADF.) Fig.3-50 (2) Close the RADF to check that the positioning pins fit smoothly into the holes on the RADF. If they do not, adjust them according to the following procedure. Fig.3-51 (3) Loosen the stepped screw 1 turn and 2 screws on the adjustment plate a half turn (status of temporary fixing). Fig.3-52 Positioning pin 1 turn Half turn
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC 3 - 54 (4) Remove the stepped screw at the rear of right-hand hinge. Fig.3-53 (5) Open the RADF, and then loosen 2 hand screws 1 turn (status of tentative fixing). Fig.3-54 (6) Remove the positioning pin at the front side. Close the RADF to fit the positioning pin into the hole at the rear side of the RADF. While peering inside from the front side, fit the posi- tions of the pin and hole by moving the RADF right and left. Fig.3-55 Screw