June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 47 6 (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5). (2) Turn OFF the power of the equipment. (3) Take off the right upper cover-1. Fig.6-44 (4) Take off the right upper cover-2. Fig.6-45 Right upper cover-1 Right upper cover-2 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 48 (5) Remove the cover plate. Fig.6-46 (6) Connect the download jig with the jig connector (CN22) on the scanning section control PC board (SLG board). Fig.6-47 (7) Turn ON the power while [0] button and [8] butto n are pressed simultaneously. Updating starts automatically and the LED on the dow nload jig lights. (8) After the update is completed properly, the LED on the download jig blinks. The LED starts blink- ing in approx. 20 sec. since the update starts. It i s assumed that the update is failed if it does not start blinking even though 1 min. has passed. In th is case, turn OFF the power and check the fol- lowing items. Then, clear the problem and restart u pdating from the beginning. Is the download jig connected properly? Is the ROM installed to the download jig properly? Is the updating data written on the ROM of the dow nload jig properly? Do the download jig and the equipment operate prop erly? (9) Turn OFF the power, remove the download jig and install the cover plate, the right upper cover-1 and the right upper cover-2. Cover plate Connector 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 49 6 (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5). (2) Turning OFF the power of the equipment. (3) Take off the RADF rear cover. (4) Connect the download jig with the connector (CN8 1) on the PC board. Fig.6-48 (5) Turn ON the power while [0] button and [8] button are pressed simultaneously. Updating starts automatically and the LED on the dow nload jig lights. (6) When the data rewriting is completed, the LED bl inks slowly (at an interval of 0.8 sec.). If the LED blinks fast (at an interval of 0.1 sec.) , the rewriting has been failed. In this case, turn OFF the power and check the following items. Then, c lear the problem and restart updating from the beginning. Is the download jig connected properly? Is the ROM installed to the download jig properly? Is the updating data written on the ROM of the dow nload jig properly? Do the download jig and the equipment operate prop erly? (7) Turn OFF the power, remove the download jig and install the RADF rear cover. Connector 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 50 (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5). (2) Turn OFF the power of the equipment. (3) Take off the finisher rear cover. Fig.6-49 *Connect the finisher interface cable with the equi pment after removing the finisher rear cover. (4) Connect the download jig with the jig connector o n the finisher control PC board. Fig.6-50 (5) Change the setting of he DIP switch on the finisher control PC board. Change all the setting of the DIP switch (1-8) to O FF. Finisher rear cover Connector 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 51 6 Note: Note: Record the current settings of the DIP switch befor e changing them. After the updating is com- pleted, return the DIP switch to the status as reco rd. Fig.6-51 (6) Turn ON the power while [0] button and [8] butto n are pressed simultaneously. Updating starts automatically and the LED on the dow nload jig lights. (7) After the update is completed properly, the LED on the download jig blinks slowly. The LED starts blinking in approx. 20 sec. since the update starts. It is assumed that the update is failed if it does not start blinking even though 1 min. has passed, o r LED flashes fast. In this case, turn OFF the power and check the following items. Then, clear th e problem and restart updating from the beginning. Is the download jig connected properly? Is the ROM installed to the download jig properly? Is the updating data written on the ROM of the dow nload jig properly? Do the download jig and the equipment operate prop erly? Is the DIP switch on the finisher control PC board set properly? (8) Turn OFF the power, remove the download jig and return the DIP switch to the status before updating. (9) Install the finisher rear cover. 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 52 Important: Before updating the FAX ROM, make sure to print ou t the current Function list for mainte- nance, Function list (ADMIN), Phone book number inf ormation and Group number informa- tion. In case the updating is failed and the regist ered information of the users is lost for some reason, re-register the user information referring to the lists and recover it. Confirm the following items before turning OFF the power of the equipment. Turning OFF the power may clear the data below. - Confirm that the “MEMORY RX” LED is OFF and there are no memory reception data. - Print the “Mailbox/Relay box report” and then conf irm that there are no F code data. - Press the [JOB STATUS] button to display the scree n and then confirm that there are no memory transmission data. (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-32 Fig.6-3 5). (2) Turn OFF the power of the equipment. (3) Remove the cover plate. Fig.6-52 (4) Connect the download jig with the jig connector (CN602) on the FAX board. Fig.6-53 Cover plate Connector 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 53 6 (5) Turn ON the power while [0] button and [8] butto n are pressed simultaneously. Updating starts automatically and the LED on the download jig light s. (6) After the update is completed properly, the LED on the download jig blinks. The LED starts blink- ing in approx. 30 sec. since the update starts. It i s assumed that the update is failed if it does not start blinking even though 1 min. has passed. In th is case, turn OFF the power and check the fol- lowing items. Then, clear the problem and restart u pdating from the beginning. Is the download jig connected properly? Is the ROM installed to the download jig properly? Is the updating data written on the ROM of the dow nload jig properly? Do the download jig and the equipment operate prop erly? (7) Turn OFF the power, remove the download jig and install the cover plate. (8) In the FAX Clearing Mode, perform the “FAX Set u p”. Confirm the destination setting is correct in the Setting Mode (08). 08-201: Destination setting of the equipment 08-701: Destination setting of the FAX machine Turn ON the power while [1] button and [*] button are pressed simultaneously. Key in “100”. Press the [START] button. Notes: If the equipment does not work properly after the ope ration (8), follow the procedure below and then perform the “Clearing the image data” in the F AX Clearing Mode to erase the image data in the memory. Confirm the destination setting is correct in the Setting Mode (08). 08-201: Destination setting of the equipment 08-701: Destination setting of the FAX machine Turn ON the power while [1] button and [*] button are pressed simultaneously. Key in “102”. Press the [START] button. [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in Setting Mode (08) to confirm that the data was overwritten properly. 08-903: Engine ROM version 08-905: Scanner ROM version 08-907: RADF ROM version 08-908: Finisher ROM version 08-915: FAX ROM version 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 54 6.3 Firmware Updating with FSMS (Field Service Manag er) (e-STUDIO200L/230/280) In this equipment, it is feasible to update the dow nloaded firmware from the PC connected with the equipment by using the utility software “FSMS (Fiel d Service Manager)”. Refer to the Field Service Manager Operator’s Manual for the details about installation method and functions of FSMS. Fig.6-54 Important: Updating through USB is not feasible for Windows N T4.0 since this operating system does not support USB. When updating through USB (using FSMS), a printer driver needs to be installed in the PC in advance. Refer to the Printing Guide about the installation method of the printer driver. OS: Windows 98 Windows Me Windows 2000 Windows XPConnecting cable: USB cable PC: IBM PC/AT or compatible machine ( USB port is needed ) 06/01
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 55 6 The types of firmware which can be updated with thi s method are as follows in the table below. Firmware Stored Data file name Master data Hard disk uidata2.tz, uidata3.tz, uidata4 .tz, uidata5.tz, uidata6.tz, uidata7.tz, webdata1.tz, webdata2.tz, webdata3.tz, webdata4.tz, webdata5.tz, webdata6.tz, all.tz System ROM System control PC board (SYS board) sysfirm.tz, uidataF.tz, uidata0.tz, uidata1.tz Engine ROM Logic PC board (LGC board) mfirm.tz Scanner ROM Scanning section control PC board (SLG board) scnfirm.tz NIC ROM NIC board nicfirm.tz
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 56 [A] Update procedure Important: Do not operate the equipment or send a print job t o the equipment during the update. This interferes the updating operation and the firmware may not be written properly. Do not turn OFF the power of equipment or PC durin g the update. The data could be dam- aged and not to be continued to function properly. When using FSMS, set “1” at FSMS permission code ( 08-258) in the Setting Mode (08) in advance. The data file (tz file format) of each firmware is recommended to save at the local drive in the PC (C drive, etc.) where FSMS program is installed. (1) Connect the equipment and PC with the cable. Fig.6-55 USB connection * Connect the PC end of the cable to the USB port on the PC. (2) Turn ON the power of the equipment. Remark: When updating with FSMS, updating can be performed in any of the normal mode, Adjustment Mode (05) and Setting Mode (08). To avoid an interr uption during the update, using the Setting Mode (08) is recommended. (3) Turn ON the power of the PC. (4) Activate FSMS. Select “TOSHIBA FSMS” starting with the Start menu. (5) Enter the login password and click the [OK] butt on. Fig.6-56 *Set the login password at the installation of FSMS. USB connector( device ) USB cable