June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 57 6 (6) Click the [F/W Download] button. Fig.6-57 (7) Select the model name of the equipment to be upd ated from the drop-down menu and click the [OK] button. Fig.6-58
![](/img/blank.gif)
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 58 (8) Click the [OFFLINE] button. Fig.6-59 (9) The connection status between the printer driver installed in the PC and the equipment to be connected is displayed. Select the equipment to be updated and click the [Activate FSMS] but- ton. Fig.6-60 Remark: The content of “Status” display can be renewed to t he latest status by clicking the [Refresh] but- ton. When the status is displayed as “Disconnected” because the start up of the equipment is delayed, the status can be renewed to “Connected” by clicking this.
![](/img/blank.gif)
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 59 6 (10) Check the firmware to be updated and click the [OK] button. Fig.6-61 Remark: The relation between the types of firmware to be up dated and items to check is as follows in the table below. Item Firmware Data file name to update Program System ROM sysfirm.tz UI Data uidataF.tz Common UI Data uidata0.tz 1st Language UI Data uidata1.tz MROM Engine ROM mfirm.tz Scan ROM Scanner ROM scnfirm.tz NIC ROM NIC ROM nicfirm.tz Generic Master data uidata2.tz, uidata3.tz, uidata4.t z, uidata5.tz, uidata6.tz, uidata7.tz, webdata1.tz, webdata2.tz, webdata3.tz, webdata4.tz, webdata5.tz, webdata6.tz, all.tz
![](/img/blank.gif)
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 60 (11) Select the data file to be updated and click th e [OK] button. There are two data filing methods: Selecting the mu ltiple data files in a batch (select the folder where the files are saved) and selecting each data file individually. Selecting the multiple data files in a batch - Select “Download File Folder”. - Click the [Browse] button and select the folder whe re the files are saved. Fig.6-62 Selecting each data file individually - Select “File Name Conversion”. - Click the [Browse] button of each data and select t he file. When “Generic Driver” is used, check the checkbox of the file to be selected. Fig.6-63
![](/img/blank.gif)
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 61 6 Remark: When selecting the multiple files in a batch, the n ame of the unselected data file (not saved in the folder) may be displayed. In this case, click the [ OK] button and then the update of all files except the displayed file starts. Fig.6-64 (12) The selected data is transmitted to the equipme nt. The data file name being transmitted and transmissi on condition are displayed at the bottom. Fig.6-65 Remark: During transmission, the message “WAIT” or “NOW SER VICING” is displayed on the LCD screen of the equipment. In this case, all the butt on operations are locked. (13) When the data transmission is completed, the fo llowing screen is displayed. Then click the [OK] button. Fig.6-66
![](/img/blank.gif)
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 62 (14) The equipment restarts automatically and the ite ms to be updated and processing status are dis- played on the LCD screen. Fig.6-67 04/09
![](/img/blank.gif)
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 63 6 (15) “Update Completed!!” is displayed at the bottom of the LCD screen after the updating is com- pleted properly. Fig.6-68 “Update Failed!!” is displayed at the bottom of the LCD screen when the updating is not com- pleted properly. Turn OFF the power, and then check the following items. After confirming and clearing the problems, restart updating from the be ginning. Are the equipment and PC properly connected? Is the selected data file proper? Do the cable, equipment and PC operate properly? Are FSMS and printer driver properly installed? Fig.6-69 04/09
![](/img/blank.gif)
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 64 *When the updating of the NIC firmware is failed, a n error message is displayed as the figure below. Turn OFF the power and then check the above- mentioned items. After confirming them, select only ”NIC ROM” (6. NIC Firmware Update ) and restart updating from the begin- ning. This may complete the updating properly. Fig.6-70 If the updating of the NIC firmware is still failed , check the prescription corresponding to the error message. After confirming and clearing the problem, restart updating from the beginning. Note: Note: If the updating of the NIC firmware is not complete d properly, wait 5 minutes or more from the beginning of the updating before turning OFF the po wer, and then restart updating from the beginning. If you turn OFF the power within 5 minut es, HDD may be destroyed. NIC Error Message Error Contents Prescription NIC UPDATE FAILED 1 NIC initialization time-out The I P address may not be assigned cor- rectly. Is the IP address assigned correctly? Does the IP address conflict with the other system? If the error still occurs, replace the NIC board because it may be destroyed. NIC UPDATE FAILED 2 ATA driver initialization error T he HDD cable may be disconnected. Is the HDD cable connected correctly? If the HDD cable is connected correctly, replace the SYS board because it may be destroyed. NIC UPDATE FAILED 3 HDD partition mount error Replace the HDD because it may be destroyed. NIC UPDATE FAILED 4 NIC setting information backup e rror Replace the HDD because it may be destroyed. NIC UPDATE FAILED 5 NIC firmware transfer error Repla ce the NIC board because it may be destroyed. NIC UPDATE FAILED 6 NIC firmware writing error Replace the NIC board because it may be destroyed. NIC UPDATE FAILED 7 NIC status time-out Replace the NI C board because it may be destroyed. 04/09
![](/img/blank.gif)
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 65 6 (16) Turn OFF the power of the equipment. (17) Perform the initialization of the updating data (NVRAM updating). Turn ON the power while [0] button and [8] button are pressed simultaneously. Key in “947”, and then press the [START] button. Press the [INITIALIZE] button. [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the data was overwritten properly. 08-925: Version of UI data language 2 in HDD 08-926: Version of UI data language 3 in HDD 08-927: Version of UI data language 4 in HDD 08-928: Version of UI data language 5 in HDD 08-929: Version of UI data language 6 in HDD 08-931: Version of UI data language 7 in HDD 08-933: HDD data unit version 08-934: Version of Web UI data language 1 in HDD 08-935: Version of Web UI data language 2 in HDD 08-936: Version of Web UI data language 3 in HDD 08-937: Version of Web UI data language 4 in HDD 08-938: Version of Web UI data language 5 in HDD 08-939: Version of Web UI data language 6 in HDD 08-900: System ROM version 08-922: UI data fixed section version 08-923: UI data common section version 08-924: Version of UI data language 1 in HDD 08-930: Version of UI data in FROM displayed at pow er ON 08-903: Engine ROM version 08-905: Scanner ROM version 08-916: NIC ROM version
![](/img/blank.gif)
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 66 6.4 Firmware Updating with USB Storage Device (e-STUDIO200L/230/280) In this equipment, it is feasible to update the fir mware by connecting the USB storage device on which the firmware data is written to the USB connector m ounted on the system control PC board and turning ON the power. The type of firmware to be updated can be selected on the LCD screen in this method. This allows to update only the necessary firmware individually or t o update all firmware in a batch. The type of firmware which can be updated with this method are as follows in the table below. Also, the data file of each firmware can be used commonly in the updating methods with USB storage device and Download jig. Firmware Stored Data file name Master data Hard disk 1, 2, 3 ... n * The file name should be consecutive num-bers from 1 to “n” without file extension. The capacity of each file is approx. 8 MB. How- ever, the file capacity of “n” (last number) may be less than 8 MB. System ROM System control PC board (SYS board) sysfirm.bin, ROM.bin Engine ROM Logic PC board (LGC board) ROM.bin Scanner ROM Scanning section control PC board (SLG board) NIC ROM NIC board 05/11