    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 27
    6
    
    (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-3 Fig.6-3) .
    (2) Turn OFF the power of the equipment. 
    (3) Take off the finisher rear cover.
     Fig.6-29
    *Connect the finisher interface cable with the equi pment after removing the finisher rear cover.
    (4) Connect the download jig with the jig connector o n the finisher control PC board.
     Fig.6-30
    Finisher rear cover
    Connector 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 28
    (5) Change the setting of he DIP switch on the finis her control PC board.
    Change all the setting of the DIP switch (1-8) to O FF.
    Note: Note: 
    Record the current settings of the DIP switch befor e changing them. After the updating is com-
    pleted, return the DIP switch to the status as reco rd.
     Fig.6-31
    (6) Turn ON the power while [0] button and [8] butto n are pressed simultaneously.
    Updating starts automatically and the LED on the dow nload jig lights.
    (7) After the update is completed properly, the LED  on the download jig blinks slowly. The LED starts 
    blinking in approx. 20 sec. since the update starts.  It is assumed that the update is failed if it does 
    not start blinking even though 1 min. has passed, o r LED flashes fast. In this case, turn OFF the 
    power and check the following items. Then, clear th e problem and restart updating from the 
    beginning. 
     Is the download jig connected properly? 
     Is the ROM installed to the download jig properly? 
     Is the updating data written on the ROM of the dow nload jig properly?
     Do the download jig and the equipment operate prop erly?
     Is the DIP switch on the finisher control PC board  set properly?
    (8) Turn OFF the power, remove the download jig and  return the DIP switch to the status before 
    updating.
    (9) Install the finisher rear cover. 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 29
    6
    
    Important:   Before updating the FAX ROM, make sure to print ou t the current Function list for mainte-
    nance, Function list (ADMIN), Phone book number inf ormation and Group number informa-
    tion. In case the updating is failed and the regist ered information of the users is lost for some 
    reason, re-register the user information referring  to the lists and recover it.
     Confirm the following items before turning OFF the  power of the equipment. Turning OFF the 
    power may clear the data below. 
    - Confirm that the “MEMORY RX” LED is OFF and there  are no memory reception data.
    - Print the “Mailbox/Relay box report” and then conf irm that there are no F code data.
    - Press the [JOB STATUS] button to display the scree n and then confirm that there are no 
    memory transmission data.
    (1) Install the ROM to the download jig. Make sure the direction is correct (P.6-3 Fig.6-3) .
    (2) Turn OFF the power of the equipment. 
    (3) Remove the cover plate.
     Fig.6-32
    (4) Connect the download jig with the jig connector  (CN602) on the FAX board.
     Fig.6-33
    Cover plate
    Connector 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 30
    (5) Turn ON the power while [0] button and [8] butto n are pressed simultaneously. Updating starts 
    automatically and the LED on the download jig light s.
    (6) After the update is completed properly, the LED  on the download jig blinks. The LED starts blink-
    ing in approx. 30 sec. since the update starts. It i s assumed that the update is failed if it does not 
    start blinking even though 1 min. has passed. In th is case, turn OFF the power and check the fol-
    lowing items. Then, clear the problem and restart u pdating from the beginning.
     Is the download jig connected properly? 
     Is the ROM installed to the download jig properly?
     Is the updating data written on the ROM of the dow nload jig properly?
     Do the download jig and the equipment operate prop erly?
    (7) Turn OFF the power, remove the download jig and  install the cover plate.
    (8) In the FAX Clearing Mode, perform the “FAX Set u p”.
     Confirm the destination setting is correct in the  Setting Mode (08).
    08-201: Destination setting of the equipment
    08-701: Destination setting of the FAX machine
     Turn ON the power while [1] button and [*] button  are pressed simultaneously.
     Key in “100”.
     Press the [START] button.
    Notes:  If the equipment does not work properly after the ope ration (8), follow the procedure below and 
    then perform the “Clearing the image data” in the F AX Clearing Mode to erase the image data in 
    the memory. 
     Confirm the destination setting is correct in the  Setting Mode (08).
    08-201: Destination setting of the equipment
    08-701: Destination setting of the FAX machine
     Turn ON the power while [1] button and [*] button  are pressed simultaneously.
     Key in “102”. 
     Press the [START] button.
    [B] Confirmation of the updated data 
    After the updating is completed, check each data ve rsion in Setting Mode (08) to confirm that the data 
    was overwritten properly.
    08-903: Engine ROM version
     08-905: Scanner ROM version
     08-907: RADF ROM version
     08-908: Finisher ROM version
     08-915: FAX ROM version 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 31
    6
    6.2 Firmware Updating with Download Jig 
    (e-STUDIO202L/232/282)
    In this equipment, it is feasible to update the fir mware automatically by connecting the download jig 
    using the dedicated connector and turning ON the eq uipment.
    The download jig consists of the ROM, in which the  program is written, and the jig board.
    And two types of the download jigs are available fo r each type of the firmware. 
    For updating the firmware, in addition to the curre nt ways such as updating each firmware individually , 
    the batch update of the firmware of the equipment i s available (except the hard disk and the option).
    Refer to the following for the details to update wi th each download jig.
      P.6-33 6.2.1 PWA-DWNLD-350-JIG2 (48 MB)
      P.6-42 6.2.2 Writing the data to the download jig  (PWA-DWNLD-350-JIG)
    Firmware Stored Download jig
    Batch update Individual update
    System ROM System control PC board  (SYS board) PWA-DWNLD-350- 
    JIG2 (48 MB)
    -
    Engine ROM Logic PC board (LGC board) K-PWA-DLM-320
    Scanner ROM Scanning section control PC  board  
    (SLG board) K-PWA-DLM-320
    RADF ROM RADF control PC board  (MR-3020) - K-PWA-DLM-320
    Finisher ROM 
    (Finisher firmware) Finisher control PC board 
    (MJ-1025) - K-PWA-DLM-320
    Finisher ROM
    (Saddle stitcher firmware) Finisher control PC board 
    (MJ-1024) - K-PWA-DLM-320
    FAX ROM FAX board (GD-1150) - K-PWA-DLM-320
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 32
    PWA-DWNLD-350-JIG2 (48MB)
     Fig.6-34 Jig board: PWA-DWNLD-350-JIG2 (48 MB)
    Important:  The download jig (PWA-DWNLD-350-JIG) is the jig in  which the Flash ROM is mounted on the 
    board directly. Therefore, ROM writer adapter (PWA- DL-ADP-350) is required to write the data to 
    these Flash ROMs. Refer to the following to write t he data.
      P.6-42 6.2.2 Writing the data to the download jig  (PWA-DWNLD-350-JIG)
    K-PWA-DLM-320
     Fig.6-35 Jig board: K-PWA-DLM-320
    Important:  Pay attention to the direction of the ROM.
    ROM4
    ROM5
    ROM6
    ROM1
    ROM2
    ROM3
    Connector (for SYS board
    connection ) Connector(
    for ROM writer
    adapter connection )
    Connector Mark for ROM
    installation direction
    ROM
    LED
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 33
    6
    6.2.1 PWA-DWNLD-350-JIG2 (48 MB)
    The firmware of the equipment except for the hard d isk and the option can be updated individually or in 
    a batch by using PWA-DWNLD-350-JIG2 (48 MB). Update  the ROM data written on each board 
    according to the need such as the case of replacing  the system control PC board, logic PC board or 
    scanning section control PC board.  
    The data to be overwritten by this update are as fol lows.
     
     System firmware (System firmware data, FROM intern al program data)
     OS data (FROM basic section software) 
     UI data (fixed section data, common section data,  UI data in FROM displayed at power ON)
     
    Engine ROM data 
     
    Scanner ROM data 
    [A] Update procedure
    Important:   Turn OFF the power before installing and removing  the download jig.
     Do not turn OFF the power during the update. The d ata could be damaged and not be oper-
    ated properly.
    (1) Write the ROM data to be updated to the download  jig.
      P.6-42 6.2.2 Writing the data to the download jig  (PWA-DWNLD-350-JIG)
    (2) Shut down the equipment. 
    (3) Remove the cover plate.
     Fig.6-36
    Cover plate
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 34
    (4) Connect the download jig with the jig connector  (CN100) on the SYS board.
     Fig.6-37
    (5) Turn ON the power while [8] button and [9] butto n are pressed simultaneously.
    The screen for selecting the items to be updated is  displayed. “*” is displayed next to the items to 
    be updated. (All items are selected in the default  settings.)
    Connector
    05/11 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 35
    6
    (6) Select the item with the digital keys. “*” is displayed next to the selected item. Display  or delete the “*” by pressing the number of the 
    item. All items are selected in the default setting s.
     Select all items to update the firmware of the equ ipment in a batch.
     Select items as follows to update it individually. 
     
    Select “0. OS Update”, “1. UI Update”, and “2. Syst em Firmware”.
     
    Select “3. Engine Firmware Update” only. 
     
    Select “4. Scanner Firmware Update” only. 
    Example: Updating the system ROM  
    (Updating all the items is taken as an example and  explained in the following procedures.) 
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 36
    (7) Press the [START] button. Updating starts and the processing status is display ed on the LCD screen.
    (8) “Update Completed.” is displayed at the bottom o f the LCD screen after the updating is com-
    pleted properly.
    Status display during update Status display when upd ate is completed 
    OS Update  ....... OS Update  ....... Completed 
    UI Data Update  ....... UI Data Update  ....... Complet ed
    SysFirm Update  ....... SysFirm Update  ....... Complet ed
    Engine MAIN Update .. Flash Update Engine MAIN Update  .. Completed
    Scanner Firm Update..Flash Update Scanner Firm Updat e.. Completed
    05/11 
    						