    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 67
    6
    Important:   The following USB storage devices are recommended  for updating.
    - MELCO ClipDrive (RUF-C128M) 
    - Lexar Media JumpDrive (RD128-231) 
    - Iomega Mini USB Drive (Mini 128 MB USB Drive)
     Only the USB storage device which meets the follow ing conditions should be used for updat-
    ing. Be careful since updating with any device othe r than the above is never guaranteed.
    - A combination USB storage device with a flash memo ry (to be connected directly to the 
    USB port) and its capacity is 64 MB or more
    - A USB storage device which is complied with the fo llowing standards regulated by USB-IF 
    (USB Implementers Forum)
    Class number: 8 (=08h) (Mass-storage class) 
    Sub-class number: 6 (=06h) (SCSI transfer command set )
    Protocol number: 80 (=50h) (Bulk-Only)
    * Most common USB storage devices are complied with t he specification above and can be 
    used for updating. However, the operation in this e quipment is not always guaranteed 
    since the most of these devices are developed based  on the use in PC environment (Win-
    dows or Macintosh).
    Therefore, confirm thoroughly that the device is op erational in this equipment when pur-
    chasing the device.
     The USB storage device complied with USB1.1 and US B2.0 can be used for updating. How-
    ever, the update is performed in the speed of USB1.1  when the device complied with USB2.0 
    is used.
     Do not update the firmware by any storage device o ther than a flash memory (such as a USB 
    connection type memory card reader, CD/DVD drive or  hard disk) since it is never guaran-
    teed.
    [A] Update procedure
    Important:   The file system of USB storage device should be fo rmatted in FAT format. Be careful since 
    the devices formatted in FAT32 or NTFS format will  not be operated. The file system can be 
    confirmed on the properties in applications such as  Explorer of Windows.
     Do not turn OFF the power during the update. The d ata could be damaged and not to be 
    operated properly.
    (1) Connect the USB storage device to the PC and wri te the data file.
     Confirm the data file name before writing (  P.6-66 6.4 Firmware Updating with USB Stor-
    age Device (e-STUDIO200L/230/280)).
     The file system of USB storage device should be fo rmatted in FAT format.
     Windows 95 and NT do not support USB. Be careful s ince the data can not be written on the 
    devices in the PCs with these operating systems.
    (2) Turn OFF the power of equipment.
    04/09 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 68
    (3) Connect the USB storage device to the USB connec tor (host) on the SYS board.
     Fig.6-71
    Notes: 
     Do not connect multiple USB storage devices togeth er.
     The USB storage device can be connected to either  of 2 USB connectors (host).
     In case the printer kit (GM-1020 or 1030), printer /scanner kit (GM-2020 or 2030) and scanner 
    upgrade kit (GM-3020 or 3030) are used, the update  must be performed after all the don-
    gles are disconnected from the USB connector (host)  and only the USB storage device is 
    connected.
    USB storage device USB connector
    (
    host ) 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 69
    6
    (4) Turn ON the power while [4] button and [9] butto n are pressed simultaneously.
    The screen for selecting the items to be updated is  displayed after 3 minutes. “*” is displayed 
    next to the items to be updated. (All items other t han 0. OS Update are selected in the default 
    settings.)
     Fig.6-72
    Note: Note:  The display of items on this screen varies dependin g on the types of data written on the USB 
    storage device. Each item is displayed only when ea ch data file is written on the USB storage 
    device in the following conditions. 
    If the USB storage device is not recognized properl y, the following message is displayed. In this 
    case, turn OFF the power of the equipment and conne ct the device properly. Then repeat the 
    procedure from (4).
     Fig.6-73
    Item Condition
    0. OS Update ROM.bin is written. 
    1. HDD Update All master data files (1, 2, 3 ... n)  are written.
    2. UI Data Update ROM.bin is written.
    3. System Firmware Update sysfirm.bin and ROM.bin ar e written.
    4. NIC Firmware Update ROM.bin is written.
    5. Scanner Firmware Update ROM.bin is written.
    6. Machine Firmware Update ROM.bin is written. 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 70
    (5) Select the item with the digital keys. “*” is displayed next to the selected item. Display  or delete the “*” by pressing the number of the 
    item. All items are selected in the default setting s.
     Select all items to update the firmware of the equ ipment in a batch.
     Select items as follows to update individually.
    Select 0. OS Update only.
     Select “1. HDD Update” only.
     Select “2. UI Data Update” and “3. System Firmware  Update”.
     Select “6. Machine Firmware Update” only.
     Select “5. Scanner Firmware Update” only.
     Select “4. NIC Firmware Update” only.
    Example:  Updating the master data and system ROM
    (Updating the master data and system ROM is taken a s an example and explained.)
     Fig.6-74 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 71
    6
    (6) Press the [START] button. Updating starts and the processing status is display ed on the LCD screen. When the multiple 
    items are selected, updating starts in order of ite m number.
     Fig.6-75
    (7) “Update Completed.” is displayed at the bottom o f the LCD screen after the updating is com-
    pleted properly.
     Fig.6-76 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 72
    Remark:  Updating can be continued with another USB storage  device on which the firmware data is writ-
    ten in the following procedure when the updating is  completed.
    1. Confirm the message “Please Connect Next Storage  Key. Push ‘START’ Button!!” is dis-
    played at the bottom of the LCD screen.
    2. Replace the USB storage device while the power is  left ON.
    3. Press the [START] button. 
    4. The screen for selecting the items to be updated  is displayed. Continue the updating from 
    procedure (5). However, the items already updated ar e not displayed on the screen.
    “Update Failed.” is displayed at the bottom of the  LCD screen when the updating is not com-
    pleted properly. Turn OFF the power, and then check  the following items. After confirming and 
    clearing the problems, restart updating from the be ginning.
     Does the USB storage device meet the conditions to  be used for updating ( P.6-66 6.4 
    Firmware Updating with USB Storage Device (e-STUDIO 200L/230/280))?
     Is the data file written properly on the USB stora ge device?
     Is the USB storage device installed properly? 
     Do the USB storage device and equipment operate pr operly?
     Fig.6-77 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 73
    6
    *When the updating of the NIC firmware is failed, a n error message is displayed as the figure 
    below. Turn OFF the power and then check the above- mentioned items. After confirming 
    them, select only “4. NIC Firmware Update” and rest art updating from the beginning. This 
    may complete the updating properly.
     Fig.6-78
    If the updating of the NIC firmware is still failed , check the prescription corresponding to the error  
    message. After confirming and clearing the problem,  restart updating from the beginning.
    Note: Note: 
    If the updating of the NIC firmware is not complete d properly, wait 5 minutes or more from the 
    beginning of the updating before turning OFF the po wer, and then restart updating from the 
    beginning. If you turn OFF the power within 5 minut es, HDD may be destroyed.
    NIC Error Message Error Contents Prescription
    NIC UPDATE FAILED 1 NIC initialization time-out The I P address may not be assigned cor-
    rectly. 
     Is the IP address assigned correctly? 
     Does the IP address conflict with the  other system?
    If the error still occurs, replace the NIC 
    board because it may be destroyed.
    NIC UPDATE FAILED 2 ATA driver initialization error T he HDD cable may be disconnected.
     Is the HDD cable connected correctly? 
    If the HDD cable is connected correctly,  
    replace the SYS board because it may be  
    destroyed.
    NIC UPDATE FAILED 3 HDD partition mount error Replace  the HDD because it may be 
    destroyed.
    NIC UPDATE FAILED 4 NIC setting information backup e rror Replace the HDD because it may be 
    destroyed.
    NIC UPDATE FAILED 5 NIC firmware transfer error Repla ce the NIC board because it may be 
    destroyed.
    NIC UPDATE FAILED 6 NIC firmware writing error Replace  the NIC board because it may be 
    destroyed.
    NIC UPDATE FAILED 7 NIC status time-out Replace the NI C board because it may be 
    destroyed.
    04/09 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 74
    (8) Turn OFF the power, remove the USB storage devic e.
    (9) Perform the initialization of the updating data  (NVRAM updating).
     Turn ON the power while [0] button and [8] button  are pressed simultaneously.
     Key in “947”, and then press the [START] button. 
     Press the [INITIALIZE] button.
    [B] Confirmation of the updated data 
    After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the 
    data was overwritten properly. 
    
    08-924: Version of UI data language 1 in HDD 
    08-925: Version of UI data language 2 in HDD
    08-926: Version of UI data language 3 in HDD
    08-927: Version of UI data language 4 in HDD
    08-928: Version of UI data language 5 in HDD
    08-929: Version of UI data language 6 in HDD
    08-931: Version of UI data language 7 in HDD
    08-933: HDD unit data version 
    08-934: Version of Web UI data language 1 in HDD 
    08-935: Version of Web UI data language 2 in HDD 
    08-936: Version of Web UI data language 3 in HDD
    08-937: Version of Web UI data language 4 in HDD 
    08-938: Version of Web UI data language 5 in HDD 
    08-939: Version of Web UI data language 6 in HDD
     08-900: System ROM version
    08-920: FROM basic section software version
    08-921: FROM internal program version
    08-922: UI data fixed section version
    08-923: UI data common section version
    08-930: Version of UI data in FROM displayed at pow er ON
     08-903: Engine ROM version
     08-905: Scanner ROM version
     08-916: NIC ROM version 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
    6 - 75
    6
    [C] Display during the update 
    The processing status is displayed as follows on th e LCD screen during the update. (As an example, 
    the display for updating the system ROM is explaine d below.)
    When the device is recognized properly after 3  
    minutes, the screen for selecting items is dis- 
    played. 
    Press the [START] button after selecting the  
    item to be updated. The device check starts. 
    						
    							e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC
    6 - 76
    When the device check completes, copying the  
    data to the HDD starts. 
    When all files have been copied, the backup of  
    RIP font starts. 
    When the backup of RIP font is completed, the  
    following screen is displayed. Updating the mas- 
    ter data is completed. 
    						