    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 145
    2
    1640 Pixel  counter Latest pixel count 
    (Toner cartridge reference) PRT 0
     SYS Displays the latest pixel 
    count in the printer  
    function and toner car- 
    tridge reference.
    [Unit: 0.01%] 2
    1649-0 Pixel  counterPixel count  
    distribution 0-5% PPC  SYS The pixel count data 
    are divided into 10  
    ranges. The number of  
    output pages in each  
    range is displayed. In  
    this code, the distribu-
    tions in the copy func- 
    tion are displayed.  
    [Unit: page]14
    1649-1 5.1-10% PPC  SYS 14 
    1649-2 10.1-15% PPC  SYS 14 
    1649-3 15.1-20% PPC  SYS 14 
    1649-4 20.1-25% PPC  SYS 14 
    1649-5 25.1-30% PPC  SYS 14
    1649-6 30.1-40% PPC  SYS 14 
    1649-7 40.1-60% PPC  SYS 14 
    1649-8 60.1-80% PPC  SYS 14 
    1649-9 80.1- 100%PPC  SYS 14
    1650-0 Pixel  counterPixel count  
    distribution 0-5% PRT  SYS The pixel count data 
    are divided into 10 
    ranges. The number of 
    output pages in each  
    range is displayed. In  
    this code, the distribu-
    tions in the printer func- 
    tion are displayed.  
    [Unit: page]14
    1650-1 5.1-10% PRT  SYS 14 
    1650-2 10.1-15% PRT  SYS 14 
    1650-3 15.1-20% PRT  SYS 14 
    1650-4 20.1-25% PRT  SYS 14
    1650-5 25.1-30% PRT  SYS 14
    1650-6 30.1-40% PRT  SYS 14
    1650-7 40.1-60% PRT  SYS 14 
    1650-8 60.1-80% PRT  SYS 14 
    1650-9 80.1- 100%PRT  SYS 14
    1651-0 Pixel  counterPixel count  
    distribution 0-5% FAX  SYS The pixel count data 
    are divided into 10  
    ranges. The number of  
    output pages in each  
    range is displayed. In 
    this code, the distribu- 
    tions in the FAX func- 
    tion are displayed.
    [Unit: page]14
    1651-1 5.1-10% FAX  SYS 14 
    1651-2 10.1-15% FAX  SYS 14 
    1651-3 15.1-20% FAX  SYS 14
    1651-4 20.1-25% FAX  SYS 14
    1651-5 25.1-30% FAX  SYS 14
    1651-6 30.1-40% FAX  SYS 14
    1651-7 40.1-60% FAX  SYS 14 
    1651-8 60.1-80% FAX  SYS 14 
    1651-9 80.1- 100%FAX  SYS 14
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default 
     RAM Contents
    Proce-
    dure 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 146
     
     The management items at PM support mode can also b e operated at setting mode (08).
    The following items are displayed or set by using s ub-codes at PM management setting in the table 
    below.
    
    0: Present number of output pages - Means the present number of output pages.
    1: Recommended number of output pages for replaceme nt
    - Means the recommended number of output pages for  replacement.
    2: Number of output pages at the last replacement
    - Means the number of output pages at the last repl acement.
    3: Present driving counts - Means the present drive counts (1 count = 2 secon ds).
    4: Recommended driving counts to be replaced - Means the recommended drive counts for replacemen t (1 count = 2 seconds).
    5: Driving counts at the last replacement - Means the drive counts at the last replacement.
    6: Present output pages for control
    - Means the present number of output pages for cont rolling.
    7: Present driving counts for control - Means the present drive counts for controlling (1  count = 2 seconds).
    8: Number of times replaced
    - Counts up when clearing the counter of each unit i n the PM Support Mode Screen.
    Notes: 
     Sub-code 3 is equivalent to sub-code 7. 
     When the value of sub-code 3 is changed, the value  of sub-code 7 is also updated and vice 
    versa.
     When “0” is set at one of sub-codes 0, 3, 6 and 7,  the rest of them are automatically updated 
    to “0”.
    05/12 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 147
    2
    Items PM management set-
    ting  
    *Indicated in 8 digits Date of previous 
    replacement 
     Remarks
    Photoconductive drum 1150-0 to 8 1151  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000
    Sub-code 4: 120,000/120,000/120,000
    Drum cleaning blade 1158-0 to 8 1159 
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000 
    Sub-code 4: 120,000/120,000/120,000
    Drum separation finger 1172-0 to 8 1173  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000 
    Sub-code 4: 120,000/120,000/120,000
    Main charger grid 1174-0 to 8 1175  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000
    Sub-code 4: 120,000/120,000/120,000
    Needle electrode 1182-0 to 8 1183  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000
    Sub-code 4: 120,000/120,000/120,000
    Ozone filter 1198-0 to 8 1199 
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 128,000/148,000/180,000 
    Sub-code 4: 240,000/240,000/240,000
    Developer material 1200-0 to 8 1201  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000 
    Sub-code 4: 120,000/120,000/120,000
    Transfer charger wire 1214-0 to 8 1215  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 64,000/74,000/90,000
    Sub-code 4: 120,000/120,000/120,000
    Separation charger wire 1224-0 to 8 1225 
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0
    Sub-code 1: 64,000/74,000/90,000 
    Sub-code 4: 120,000/120,000/120,000
    Fuser roller 1246-0 to 8 1247  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 128,000/148,000/180,000 
    Sub-code 4: 240,000/240,000/240,000
    Pressure roller 1250-0 to 8 1251  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 128,000/148,000/180,000
    Sub-code 4: 240,000/240,000/240,000
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 148
    Cleaning roller 1266-0 to 8 1267  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 128,000/148,000/180,000 
    Sub-code 4: 240,000/240,000/240,000
    Fuser roller separation  
    finger 1268-0 to 8 1269  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0 
    Sub-code 1: 128,000/148,000/180,000 
    Sub-code 4: 240,000/240,000/240,000
    Pickup roller (RADF) 1282-0,1,2,8 1283 
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 120,000/120,000/120,000
    Feed roller (RADF) 1284-0,1,2,8 1285 
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 120,000/120,000/120,000
    Separation roller  
    (RADF) 1286-0,1,2,8 1287  
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 120,000/120,000/120,000
    Pickup roller
    (Upper drawer) 1290-0,1,2,8 1291  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Pickup roller
    (Lower drawer) 1292-0,1,2,8 1293  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Pickup roller (LCF) 1294-0,1,2,8 1295  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 160,000/160,000/160,000
    Feed roller
    (Upper drawer) 1298-0,1,2,8 1299  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Feed roller
    (Lower drawer) 1300-0,1,2,8 1301  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Feed roller (LCF) 1302-0,1,2,8 1303  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 160,000/160,000/160,000
    Separation roller
    (Upper drawer) 1306-0,1,2,8 1307  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Separation roller
    (Lower drawer) 1308-0,1,2,8 1309  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Items
    PM management set-
    ting  
    *Indicated in 8 digits Date of previous 
    replacement 
     Remarks
    05/12 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 149
    2
    Separation roller (LCF) 1310-0,1,2,8 1311  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 160,000/160,000/160,000
    Separation roller 
    (PFP upper drawer) 1312-0,1,2,8 1313  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Separation roller 
    (PFP lower drawer) 1314-0,1,2,8 1315  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Separation roller 
    (Bypass unit) 1316-0,1,2,8 1317 
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Feed roller 
    (PFP upper drawer) 1320-0,1,2,8 1321 
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Feed roller 
    (PFP lower drawer) 1322-0,1,2,8 1323  
    Sub-codes 0, 2, 8: 0/0/0 
    Sub-code 1: 80,000/80,000/80,000
    Feed roller 
    (Bypass unit) 1324-0,1,2,8 1325  
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 80,000/80,000/80,000
    Pickup roller 
    (PFP upper drawer) 1328-0,1,2,8 1329  
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 80,000/80,000/80,000
    Pickup roller 
    (PFP lower drawer) 1330-0,1,2,8 1331  
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 80,000/80,000/80,000
    Pickup roller 
    (Bypass unit) 1332-0,1,2,8 1333  
    Sub-codes 0, 2, 8: 0/0/0
    Sub-code 1: 80,000/80,000/80,000
    Recovery blade 1336-0 to 8 1337  
    Sub-codes 0, 2, 3, 5, 6, 7, 8: 0/0/0
    Sub-code 1: 64,000/74,000/90,000 
    Sub-code 4: 120,000/120,000/120,000
    Items
    PM management set-
    ting  
    *Indicated in 8 digits Date of previous 
    replacement 
     Remarks
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 150
    
    (1) Turn ON the power while [0] and [8] are pressed  simultaneously.
    (2) Key in the code “257” with the digital keys and  press the [START] button (the following is dis-
    played).
    Note: Note:  Before performing the following operations, note th e current counter values.
     Fig. 2-4
    (3) Key in the value “1” or “2” with the digital key and press the [START] button.
    The value entered is displayed on the left of the “ %”, and the [ENTER] button is displayed.
    Note: Note: 
    The value can be erased by pressing the [CLEAR] but ton to change as long as the [START] but-
    ton is not pressed. (The value on the left of the “ %” is reset to “0” by pressing the [CLEAR] but-
    ton.) 
     Key in “1” to copy the value of the total  counter (LGC board) (A) onto the value of  
    the backup counter (SYS board) (B).
     Fig. 2-5
    (A)(B)
    05/12   
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 151
    2
    (4) Press the [ENTER] button to complete overwriting of  the counter value.
    Note: Note: 
    The screen returns to the code entry screen without  copying (overwriting) the value when the 
    [CANCEL] button is pressed.
     Key in “2” to copy the value of the backup 
    counter (SYS board) (B) onto the value of  
    the total counter (LGC board) (A).
     Fig. 2-6
    (A) (B)
    05/12  
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 152
    2.2.8 Setting mode (08) (e-STUDIO202L/232/282)
    Procedure 1 
    * Press [FUNCTION CLEAR] to enter minus (-). 
    Procedure 2 
    Procedure 3 
    Procedure 4 
    * Press [FUNCTION CLEAR] to enter minus (-). 
    Procedure 5 
    * Press [HELP] to enter “-”.
    The items in the setting code list can be set or ch
    anged in this setting mode (08).
    (Stores value in RAM)
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key](Code) [START]
    [Digital key]
    *
    [FUNCTION CLEAR]
    [ENTER] or
    [INTERRUPT]
    Sets or
    changes value
    [CLEAR]
    (Corrects value)[CANCEL]
    [0][8]
    [POWER] [POWER]OFF/ON
    (Exit)[Digital key]
    (Code) [START] [ENTER]
    or
    [INTERRUPT]
    Adjustment value
    cannot be changed
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key]
    (Code) [START]
    [CANCEL] or [CLEAR](Automatic setting)
    [ENTER]
    or
    [INTERRUPT]
    (Stores value in RAM)
    [0][8]
    [POWER] [POWER]
    OFF/ON (Exit)
    [Digital key]
    (Code) [Digital key]
    (Sub-code) [Digital key]
    *
     [FUNCTION CLEAR]Sets or
    changes value
    [START] [START]
    [ENTER]
    or
    [INTERRUPT] (Stores value
    in RAM)
    [CLEAR]
    (Corrects value)[CLEAR]
    (Corrects value)
    [START]
    [CANCEL]
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key]
    (Code) [Digital key]
    *[HELP]
    [START]
    [CANCEL]
    [ENTER]
    or
    [INTERRUPT]
    [CLEAR]
    (Corrects value) (Stores value in RAM)
    Sets or
    changes value
    05/12 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 153
    2
    Procedure 7 
    Procedure 9 
    Procedure 10 
    Procedure 11 and 12 
    *1.  Press [MONITOR/PAUSE] to enter “-”, when enteri ng telephone number.
    *2.  The data are stored in SYS-RAM in procedure 11  and stored in NIC-RAM in procedure 12.
    Procedure 14
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key]
    (Code)[Digital key]
    (Setting)
    [CLEAR]
    (Corrects value)
    [START](HDD formatting)
    [CANCEL]
    [ENTER]
    or
    [INTERRUPT] (Stores value in RAM)
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key]
    (Code) [Select icon]
    [START] [CANCEL]
    [ENTER]
    or
    [INTERRUPT]
    [CLEAR]
    (Corrects value) (Stores value in RAM)
    [0][8]
    [POWER] [POWER]
    OFF/ON
    (Exit)
    [Digital key]
    (Code) [Digital key]
    (1st setting) [Digital key]
    (2nd setting)
    [START] [START] [CANCEL]
    [ENTER]or
    [INTERRUPT]
    [CLEAR]
    (Corrects value) [CLEAR]
    (Corrects value) (Stores value in RAM)
    [0][8]
    [POWER] [POWER] OFF/ON
    (Exit)
    [Digital key]
    (Code) [Digital key]
    or
    [Software keyboard][START]
    [CANCEL]
    [CLEAR] 
    (Corrects value)*2(Stores value in RAM)*1[MONITOR/PAUSE]
    Sets or
    changes value [ENTER]
    [0][8]
    [POWER] [POWER]
    OFF/ON (Exit)
    [Digital key]
    (Code) [Digital key]
    (Sub-code)
    [CLEAR]
    (Corrects value)
    [START] [START]
    [CANCEL]
    [ENTER]
    or
    [INTERRUPT]
    Adjustment value
    cannot be changed
    05/12 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 154
    Notes:  The digit after the hyphen in “Code” of the follow ing table is a sub code.
     e-STUDIO202L/232/282: In “RAM”, the NVRAM of the bo ard in which the data of each code
    is stored is indicated. “M” stands for the LGC boar d, “SYS”, “NIC”  
    and “UTY” stands for the SYS board.
    Setting mode (08) 
    Code Classifi-
    cation Items
    Func-
    tion Default
     RAM Contents
    Proce-
    dure
    200 General Date and time setting ALL -  - Year/month/date/day/
    hour/minute/second 
    Example:03 07 0 13 13 27 48 
    “Day” - “0” is for  
    “Sunday”. Pro- 
    ceeds Monday 
    through Saturday  
    from “1” to “6”. 5
    201 General Destination selection ALL EUR: 0 UC: 1
    JPN: 2  M 0: EUR
    1: UC 
    2: JPN 1
    202 User  interface Counter installed externally ALL 0
    M 0: No external counter
    1: Coin controller
    2: Copy key card 
    3: Key copy counter 1
    203 General Line adjustment mode ALL 0 M 0: For factory shipment
    1: For line 
    * Field: “0” must be selected 1
    204 User  interface Auto-clear timer setting ALL 3
    SYS Timer to return the 
    equipment to the 
    default settings when  
    the [START] button is  
    not pressed after the 
    function and the mode  
    are set 
    0: Not cleared
    1 to 10: Set number x  
    15 sec. 1
    205 User  interface Auto power save mode  
    timer setting ALL EUR: 11
    UC: 11
    JPN: 6
    Others:  11
     SYS Timer to automatically 
    switch to the Auto  
    power save mode when 
    the equipment has not  
    been used 
    0: Invalid 6: 3min. 
    7: 4min. 8: 5min. 
    9: 7min. 
    10: 10min. 
    11: 15min. 
    12: 20min. 
    13: 30min.
    14: 45min. 
    15: 60min. 1