June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 87 6 “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com- pleted properly. “Failed” appears next to the faile d item on the status display. Turn OFF the power, and then check the following items. After co nfirming and clearing the problems, restart updating from the beginning. Does the USB storage device meet the conditions to be used for updating ( P.6-80 6.5 Firmware Updating with USB Storage Dev ice (e-STUDIO202L/232/282))? Is the data file written properly on the USB stora ge device? Is the USB storage device installed properly? Do the USB storage device and equipment operate pr operly? (8) Turn OFF the power, remove the USB storage devic e and install the cover plate. (9) Perform the initialization of the updating data. Turn ON the power while [0] button and [8] button are pressed simultaneously. Key in “947”, and then press the [START] button. Press the [INITIALIZE] button. 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 88 [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the data was overwritten properly. 08-924: Version of UI data language 1 in HDD 08-925: Version of UI data language 2 in HDD 08-926: Version of UI data language 3 in HDD 08-927: Version of UI data language 4 in HDD 08-928: Version of UI data language 5 in HDD 08-929: Version of UI data language 6 in HDD 08-931: Version of UI data language 7 in HDD 08-933: HDD unit data version 08-934: Version of Web UI data language 1 in HDD 08-935: Version of Web UI data language 2 in HDD 08-936: Version of Web UI data language 3 in HDD 08-937: Version of Web UI data language 4 in HDD 08-938: Version of Web UI data language 5 in HDD 08-939: Version of Web UI data language 6 in HDD 08-900: System ROM version 08-922: UI data fixed section version 08-923: UI data common section version 08-930: Version of UI data in FROM displayed at powe r ON 08-903: Engine ROM version 08-905: Scanner ROM version 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 89 6 [C] Display during the update Update is performed in parallel as shown in the tra nsition diagram below. Item Selection Screen for Update Update Completed [System ROM] [Engine ROM] [scanner ROM] 4. Engine Firmware Update [Master data] 5. Scanner Firmware Update 0. OS Update 1. HDD Update 2. UI Data Update 3. System Firmware Update 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 90 Below is an example of the changes of the LCD scree n during update. Note that the screen order may be different from th e actual one, because a parallel update is performe d in the process. The initial screen is displayed and the recogni- tion of the USB storage device connected to the equipment is started. When the device is recognized properly, the screen for selecting update items is displayed. Select items to be updated and press the [START] button to start updating the [System ROM], [Master Data], [Engine ROM] and [Scanner ROM] in parallel. Turn ON the power while [4] button and [9] button are pressed simultaneously 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 91 6 When the [System ROM]-[OS Update] has been updated, “OS Update…Completed” is displayed and the [UI Update] update will start. When the [System ROM]-[UI Update] has been updated, “UI Data Update…Completed” is dis- played and the [System Firmware Update] update will start. 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 92 When the [Engine ROM] has been updated, “Engine MAIN Update..Flash Update” is changed to “Engine MAIN Update..Com- pleted”. When the [System ROM]-[System Firmware Update] has been updated, “SysFirm Update…Completed” is displayed. When the [Master Data] has been updated, “HD Data Update…Completed” is displayed. File name of master dataTotal files Copies 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 93 6 When the [Scanner ROM] has been updated, “Scanner Firm Update..Flash Update” is changed to “Scanner Firm Update..Com- pleted”. When all data has been updated, “Update Completed” is displayed. 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 94 * If the USB storage device is not recognized proper ly, the following message is displayed and the update is interrupted. * “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not completed properly. “Failed” appears next to the failed item on the status display. Error message Failed items 05/11
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 95 6 6.6 Appendix 6.6.1 e-STUDIO200L/230/280 [A] Assist Mode This equipment has the Assist Mode to enable the fo llowing functions. 1) NVRAM flag clearing (“Clear NvRAM flags.”) Even if the firmware downloading has been completed normally, the Recovery Mode may acciden- tally start up when the power is turned ON again. I n this case, clear the NVRAM flags used in the download process with this function. (Normally, the flags are automatically cleared in t he download process.) Also in the case the Recovery Mode accidentally sta rts up after the replacement of NVRAM on the SYS board, the flags are cleared with this function . 2) Data storage partition formatting (“Format UID ro m PRF PR2 SMS Partition.”) When a defection occurs on the UI data, etc. which a re stored in the HDD, the partition with the stored UI data, etc. is formatted with this functio n. (Do not use this function since it is not normally ne cessary.) 3) HDD partition creation (“All Partition delete and create UID rom PRF PR2 SMS Partition.”) When the HDD is replaced or UI data, etc. are downl oaded using the FSMS or USB storage, it is necessary to format a partition in the HDD before d ownloading. In this case, the partition is created in the HDD with this function. Notes: When downloading with a download jig, it is not ne cessary to format a partition in advance. Perform the HDD partition formatting only when a n ew HDD and scrambler board are installed since all data in the current HDD are erased by thi s operation. [B] Operating Procedure of Assist Mode (1) Turn ON the power while [3] button and [CLEAR] b utton are pressed simultaneously. The following screen is displayed. Fig.6-80 (2) Select the item with the digital keys and press the [START] button. 05/11
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 96 6.6.2 e-STUDIO202L/232/282 [A] Assist Mode This equipment has the Assist Mode to enable the fo llowing functions. (1) NVRAM flag clearing (“Clear NvRAM flags.”) Even if the firmware downloading has been completed normally, the Recovery Mode may acci- dentally start up when the power is turned ON again . In this case, clear the NVRAM flags used in the download process with this function. (Normally, the flags are automatically cleared in the download process.) Also in the case the Recovery Mode accidentally starts up after the replacement of NVRAM on the SYS board, the flags are cleared with this func tion. (2) Data storage partition formatting (“Format Loade r Partition.”) When a defection occurs on the UI data, etc. which are stored in the HDD, the partition with the stored UI data, etc. is formatted with this functio n. (Do not use this function since it is not nor- mally necessary.) (3) HDD partition creation (“All Partition Delete an d Create Loader Partition.”) When the HDD is replaced or UI data, etc. are downl oaded using the USB storage, it is neces- sary to format a partition in the HDD before downlo ading. In this case, the partition is created in the HDD with this function. Notes: 1. When downloading with a download jig, it is not n ecessary to format a partition in advance. 2. Perform the HDD partition formatting only when a new HDD and scrambler board are installed since all data in the current HDD are erased by thi s operation. [B] Operating Procedure of Assist Mode (1) Turn ON the power while [3] button and [CLEAR] b utton are pressed simultaneously. The following screen is displayed. (2) Select the item with the digital keys and press the [START] button. 05/11