June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 7 6 [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the data was overwritten properly. 08-900: System ROM version 08-920: FROM basic section software version 08-921: FROM internal program version 08-922: UI data fixed section version 08-923: UI data common section version 08-924: Version of UI data language 1 in HDD 08-925: Version of UI data language 2 in HDD 08-926: Version of UI data language 3 in HDD 08-927: Version of UI data language 4 in HDD 08-928: Version of UI data language 5 in HDD 08-929: Version of UI data language 6 in HDD 08-931: Version of UI data language 7 in HDD 08-930: Version of UI data in FROM displayed at pow er ON 08-933: HDD unit data version 08-934: Version of Web UI data language 1 in HDD 08-935: Version of Web UI data language 2 in HDD 08-936: Version of Web UI data language 3 in HDD 08-937: Version of Web UI data language 4 in HDD 08-938: Version of Web UI data language 5 in HDD 08-939: Version of Web UI data language 6 in HDD
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 8 [C] Display during the update The processing status is displayed as follows on th e LCD screen during the update. The device check starts. When the device check completes, copying the data to HDD starts.
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 9 6 When copying all the files completes, the backup of the RIP font starts. When the backup of the RIP font completes, the update completes with the following screen.
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 10 * If an error occurs, the following error message is displayed and the update is interrupted.
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 11 6 6.1.2 PWA-DWNLD-350-JIG1 (16 MB) The firmware of the equipment except the hard disk and the option can be updated individually or in a batch by using PWA-DWNLD-350-JIG1 (16 MB). Update t he ROM data written on each board accord- ing to the need such as the case of replacing the sy stem control PC board, logic PC board, scanning section control PC board, or NIC board. The data to be overwritten by this update are as fol lows. System firmware (System firmware data, FROM intern al program data) OS data (FROM basic section software) UI data (fixed section data, common section data, UI data in FROM displayed at power ON) Engine ROM data Scanner ROM data NIC ROM data [A] Update procedure Important: Use the download jig “PWA-DWNLD-350-JIG1 (16 MB)”. (“PWA-DWNLD-350-JIG2 (48 MB)” is substitutable.) Turn OFF the power before installing and removing the download jig. Do not turn OFF the power during the update. The d ata could be damaged and not be oper- ated properly. (1) Write the ROM data to be updated to the download jig. P.6-20 6.1.3 Writing the data to the download jig (PWA-DWNLD-350-JIG) (2) Turn OFF the power of the equipment. (3) Remove the cover plate. Fig.6-9 Cover plate
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 12 (4) Connect the download jig with the jig connector (CN100) on the SYS board. Fig.6-10 (5) Turn ON the power while [8] button and [9] butto n are pressed simultaneously. The screen for selecting the items to be updated is displayed. “*” is displayed next to the items to be updated. (All items are selected in the default settings.) Fig.6-11 Connector
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 13 6 (6) Select the item with the digital keys. “*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the item. All items are selected in the default setting s. Select all items to update the firmware of the equ ipment in a batch. Select items as follows to update it individually. Select “1. OS Update”, “2. UI Update”, and “3. Syst em Firmware”. Select “6. Machine Firmware Update” only. Select “5. Scanner Firmware Update” only. Select “4. NIC Firmware Update” only. Example: Updating the system ROM (Updating the system ROM is taken as an example and explained.) Fig.6-12 (7) Press the [START] button. Updating starts and the processing status is display ed on the LCD screen. Fig.6-13
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 14 (8) “Update Completed!!” is displayed at the bottom of the LCD screen after the updating is com- pleted properly. Fig.6-14 “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com- pleted properly. Turn OFF the power, and then check the following items. After confirming and clearing the problems, restart updating from the be ginning. Is the download jig connected properly? Is the updating data written to the download jig p roperly? Do the download jig and the equipment operate prop erly? Fig.6-15
June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING 6 - 15 6 *When the updating of the NIC firmware is failed, a n error message is displayed as the figure below. Turn OFF the power and then check the above- mentioned items. After confirming them, select only “4. NIC Firmware Update” and rest art updating from the beginning. This may complete the updating properly. Fig.6-16 If the updating of the NIC firmware is still failed , check the prescription corresponding to the error message. After confirming and clearing the problem, restart updating from the beginning. Note: Note: If the updating of the NIC firmware is not complete d properly, wait 5 minutes or more from the beginning of the updating before turning OFF the po wer, and then restart updating from the beginning. If you turn OFF the power within 5 minut es, HDD may be destroyed. NIC Error Message Error Contents Prescription NIC UPDATE FAILED 1 NIC initialization time-out The I P address may not be assigned cor- rectly. Is the IP address assigned correctly? Does the IP address conflict with the other system? If the error still occurs, replace the NIC board because it may be destroyed. NIC UPDATE FAILED 2 ATA driver initialization error T he HDD cable may be disconnected. Is the HDD cable connected correctly? If the HDD cable is connected correctly, replace the SYS board because it may be destroyed. NIC UPDATE FAILED 3 HDD partition mount error Replace the HDD because it may be destroyed. NIC UPDATE FAILED 4 NIC setting information backup e rror Replace the HDD because it may be destroyed. NIC UPDATE FAILED 5 NIC firmware transfer error Repla ce the NIC board because it may be destroyed. NIC UPDATE FAILED 6 NIC firmware writing error Replace the NIC board because it may be destroyed. NIC UPDATE FAILED 7 NIC status time-out Replace the NI C board because it may be destroyed. 04/09
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATINGJune 2004 © TOSHIBA TEC 6 - 16 (9) Turn OFF the power, remove the download jig and install the cover plate. (10) Perform the initialization of the updating data (NVRAM updating). Turn ON the power while [0] button and [8] button are pressed simultaneously. Key in “947”, and then press the [START] button. Press the [INITIALIZE] button. [B] Confirmation of the updated data After the updating is completed, check each data ve rsion in the Setting Mode (08) to confirm that the data was overwritten properly. 08-900: System ROM version 08-920: FROM basic section software version 08-921: FROM internal program version 08-922: UI data fixed section version 08-923: UI data common section version 08-930: Version of UI data in FROM displayed at pow er ON 08-903: Engine ROM version 08-905: Scanner ROM version 08-916: NIC ROM version