    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 115
    2
    638 General Time differences ALL EUR: 24 UC: 40JPN: 6
     SYS 0: +12.0h 1: +11.5h
    2: +11.0h 3: +10.5h 
    4: +10.0h 5: +9.5h 
    6: +9.0h 7: +8.5h
    8: +8.0h 9: +7.5h 
    10: +7.0h 11: +6.5h 
    12: +6.0h 13: +5.5h
    14: +5.0h 15: +4.5h 
    16: +4.0h 17: +3.5h 
    18: +3.0h 19: +2.5h 
    20: +2.0h 21: +1.5h 
    22: +1.0h 23: +0.5h 
    24: 0.0h 25: -0.5h 
    26: -1.0h 27: -1.5h 
    28: -2.0h 29: -2.5h 
    30: -3.0h 31: -3.5h
    32: -4.0h 33: -4.5h 
    34: -5.0h 35: -5.5h 
    36: -6.0h 37: -6.5h
    38: -7.0h 39: -7.5h 
    40: -8.0h 41: -8.5h 
    42: -9.0h 43: -9.5h
    44: -10.0h
    45: -10.5h 
    46: -11.0h 
    47: -11.5h 1
    640 User  interface Date display format ALL EUR: 1
    UC: 2
    JPN: 0
     SYS 0: YYYY.MM.DD.
    1: DD.MM.YYYY 
    2: MM.DD.YYYY 1
    641 User  interface Automatic Sorting Mode  
    setting (RADF) PPC 2
     SYS 0: Invalid 1: STAPLE
    2: SORT 3: GROUP 
    4: ROTATE SORT 1
    642 User  interface Default setting of Sorter  
    Mode PPC 0
     SYS 0: NON-SORT
    1: STAPLE 
    2: SORT 3: GROUP 
    4: ROTATE SORT 1
    645 User  interface Correction of reproduction  
    ratio in editing copy PPC 10
     SYS Sets the reproduction 
    ratio for the “X in 1” 
    printing (including mag- 
    azine sort) to the  
    “Reproduction ratio x  
    Correction ratio”. 
    0: 90% 1: 91% 
    2: 92% 3: 93%
    4: 94% 5: 95% 
    6: 96% 7: 97% 
    8: 98% 9: 99%
    10: 100% 1
    646 User  interface Image position in editing PPC 0
    SYS Sets the page pasted 
    position for “X in 1” to  
    the upper left corner/ 
    center. 
    0: Cornering 
    1: Centering 1
    647 User  interface Rotation of paper direction  
    for BOX printing ALL 1
     SYS 0: Rotation OFF
    1: Rotation ON 1
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default
     RAM Contents
    Proce-
    dure
    05/11 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 116
    648 User 
    interface Returning finisher tray  
    when printing is finished ALL 0
     SYS Sets whether or not 
    returning the finisher  
    tray to the bin 1 when  
    printing is finished.
    0: Not returned 
    1: Returned 1
    649 User  interface Magazine sort setting PPC 0
    SYS 0: Left page to right 
    page
    1: Right page to left  page 1
    650 User  interface 2 in 1/4 in 1 page allocating  
    order setting PPC 0
     SYS 0: Horizontal
    1: Vertical 1
    651 User  interface Printing format setting for 
    Time stamp and Page  
    Number PPC 2
     SYS Hyphen 
    (with page number)
    /Dropout 
     (with date, time and 
    page number) 
    0: OFF/OFF 
    1: ON/OFF
    2: OFF/ON 
    3: ON/ON
    Note: Note: Hyphen printing  
    format 
    ON: -1-  OFF: 1 1
    652 User  interface Cascade operation setting PPC 0
    SYS 0: OFF 1: ON 1
    653 User  interface Cascade operation setting PRT 0
    SYS 0: OFF   1: ON 1
    657 User  interface Direction priority for date 
    and time stamp printing PPC 0
     SYS 0: Short edge
    1: Long edge 1
    658 User  interface Auto Job Start setting for 
    bypass feed printing PRT 0
     SYS Sets whether or not 
    feeding a paper auto- 
    matically into the equip- 
    ment when it is placed 
    on the bypass tray. 
    0: OFF (Press the 
    [START] button to  
    start feeding.)
    1: ON (Automatic 
    feeding) 1
    659 User  interface Auto Job start setting for  
    bypass feed printing PPC 1
     SYS Sets whether or not 
    feeding a paper auto- 
    matically into the equip- 
    ment when it is placed 
    on the bypass tray. 
    0: OFF (Press the [START] button to  
    start feeding.)
    1: ON (Automatic 
    feeding) 1
    660 Network Auto-forwarding setting of  received FAX ALL 0
     SYS 0: Invalid
    1: Valid 1
    661 Network Auto-forwarding setting of  received E-mail ALL 0
     SYS 0: Invalid
    1: Valid 1
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default
     RAM Contents
    Proce-
    dure
    04/09 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 117
    2
    662 General Clearing of SMS partition ALL - SYS Clears SM S partition.
    (Performs when the  
    service call [F106] has  
    occurred.) 3
    666 General /SHR partition clearing ALL - SYS Initializes  the Elec-
    tronic Filing. 3
    667 General /SHA partition clearing ALL - SYS Initializes  the shared 
    folder. 3
    670 General HDD diagnostic menu dis- play ALL - SYS Display the HDD infor-
    mation 2
    671 User  interface Size indicator ALL 0
    SYS 0: Invalid
    1: Valid 1
    672 General Initialization of department  management information - - SYS Initializing of the depart-
    ment management 
    information
    * Key in the code and 
    press the [INITIAL-
    IZE] button to per-
    form the  
    initialization. If the  
    area storing the 
    department man- 
    agement informa- 
    tion is destroyed for  
    some reason, “Enter  
    Department Code”  
    is displayed on the  
    control panel even if  
    the department  
    management func- 
    tion is not set on. In 
    this case, initialize  
    the area with this  
    code. This area is  
    normally initialized  
    at the factory. 3
    673 General Trial period setting PRT/ SCN254
     SYS Sets the trial period 
    from 1 to 60 days. This  
    setting is effective only  
    when the default value  
    is “254”. Once the 
    default value is set, this  
    value is only used for a  
    reference. 1
    678 General Setting of banner advertis- ing display ALL 0
     SYS Sets whether or not dis-
    playing the banner  
    advertising. The setting  
    contents of 08-679 and  
    08-680 are displayed at  
    the time display section  
    on the right top of the  
    screen. When both are  
    set, each content is dis- 
    played alternately.
    0: Not displayed 
    1: Displayed 1
    679 General Banner advertising display  1 ALL - SYS Maximum 27 letters 
    (one-byte character) 11
    Setting mode (08) 
    Code Classifi-
    cation Items
    Func-
    tion Default
     RAM Contents
    Proce-
    dure 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 118
    680 General Banner advertising display 
    2 ALL - SYS Maximum 27 letters 
    (one-byte character) 11
    681 General Display of [BANNER MES- SAGE] button  ALL 0
     SYS 0: Not displayed
    1: Displayed 
    * This button enables 
    the entry of “Banner  
    advertising display 1  
    (08-679)” and “Ban- 
    ner advertising dis- 
    play 2 (08-680)” on  
    the control panel. 1
    682 User  interface Offsetting between jobs ALL 0
    SYS 0: Invalid
    1: Valid 1
    683 General Duplex printing setting  when coin controller is 
    used ALL 1
     SYS When the duplex print-
    ing is short paid with a 
    coin controller, reverse 
    side of the original is  
    not printed and is con- 
    sidered as a defect 
    (printing job may be  
    cleared). To solve this  
    problem, the selection 
    of printing method is 
    enabled with this set- 
    ting. 
    0: Invalid (Both sides 
    printed)
    1: Valid (Only one side 
    printed) 1
    684 General Rebuilding all databases ALL - SYS Rebuilds a ll databases. 3
    685 General Rebuilding all databases  related to address book ALL - SYS Rebuilds all databases 
    related to the Address  
    Book. 3
    686 General Rebuilding all databases  related to log ALL - SYS Rebuilds all databases 
    related to the log. 3
    689 FAX Adaptation of paper source  priority selection FAX 0
     SYS 0: Not subjected for 
    APS judgment
    1: Subjected for APS 
    judgment 1
    690 General HDD formatting ALL - SYS 2: Normal formatting 7
    691 General HDD type display ALL - SYS 0: Not formatted
    1: Not used 
    2: Normal format 7
    692 Mainte- nance Performing panel calibra- 
    tion ALL - SYS Performs the calibration 
    of the pressing position  
    on the touch panel  
    (LCD screen). The cali-
    bration is performed by  
    pressing 2 reference  
    positions after this code 
    is started up. 1
    693 General Initialization of NIC infor- mation ALL - SYS Returns the value to the 
    factory shipping default  
    value. 3
    694 General Performing HDD testing ALL - SYS Checks the b ad sector. 3
    Setting mode (08) 
    Code Classifi-
    cation Items
    Func-
    tion Default
     RAM Contents
    Proce-
    dure 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 119
    2
    695 General Notifying condition of trial  period end PRT/
    SCN 3
     SYS Sets when the end of 
    trial period is notified. 
    0: On the day it ends 
    1 to 59: n days before 1
    696 Scram- bler 
    board Installation of scrambler  
    board (Option)
    ALL 0
     - 0: Not installed
    1: Installed 2
    697 Paper  feeding Paper type priority PPC 1
    SYS Sets the paper type pri-
    ority during copying. 
    1: Plain paper 
    2: Thick paper 1 1
    698 Scram- bler 
    board Entering the key code for  
    scrambler board
    ALL - - Start up this code and 
    have the user enter the 
    key code. 
    Once the key code has  
    been set, this code can-
    not be set again on  
    security grounds. 5
    699 Scram- bler 
    board Erasing all data in HDD ALL - - This setting is effectiv
    e 
    only when the scram- 
    bler board is installed. 3
    701 FAX Destination setting for FAX FAX EUR: 5 UC: 4
    JPN: 0
    Other: 1
     SYS 0: Japan 1: Asia
    2: Australia 
    3: Hong Kong 
    4: U.S.A./Canada
    5: Germany 6: U.K. 
    7: Italy 
    8: Belgium
    9: Netherlands 
    10: Finland 
    11: Spain
    12: Austria 
    13: Switzerland 
    14: Sweden
    15: Denmark 
    16: Norway 
    17: Portugal
    18: France 
    19: Greece 
    20: Poland
    21: Hungary 
    22: Czech 
    23: Turkey 
    24: South Africa 
    25: Taiwan 1
    702 Mainte- nance Remote-controlled service  
    function ALL 2
     SYS 0: Valid (Remote-con-
    trolled server)
    1: Valid (L2) 
    2: Invalid 1
    703 Mainte- nance Remote-controlled service 
    HTTP server
    URL setting ALL - SYS Maximum 256 Bytes 11
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default
     RAM Contents
    Proce-
    dure
    04/09 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 120
    707 Mainte-
    nance Remote-controlled service 
    HTTP initially-registered  
    server 
    URL setting ALL https://
    device. 
    mfp- 
    support.
    com:443/ 
    device/ 
    firstregist.
    ashx SYS Maximum 256 Bytes 11
    710 Mainte- nance
    (Remote) Short time interval setting  
    of recovery from Emer- 
    gency Mode ALL 24
     SYS Sets the time interval to 
    recover from the Emer-
    gency Mode to the Nor-
    mal Mode. 
    (Unit: Hour) 1
    711 Mainte- nance
    (Remote) Short time interval setting  
    of Emergency Mode 
    ALL 60
     SYS Unit: Minute 1
    715 Mainte- nance Remote-controlled service  
    periodical polling timing 
    (Hour/Hour/Minute/Minute) ALL 1230 SYS 0 (0:00) to 2359 (23:59) 1
    716 Mainte- nance Remote-controlled service 
    Writing data of self-diag-
    nostic code ALL 0
     SYS 0: Prohibited
    1: Accepted 1
    717 Mainte- nance Remote-controlled service  
    response waiting time 
    (Timeout) ALL 3
     SYS Unit: Minute 1
    718 Mainte- nance Remote-controlled service 
    initial registration ALL 0
     SYS 0: OFF
    1: Start 
    2: Only certification is 
    scanned 1
    719 Mainte- nance Remote-controlled service  
    tentative password ALL - SYS Maximum 10 letters 11
    720 Mainte- nance Status of remote-con- 
    trolled service initial regis- 
    tration 
    (Display only) ALL 0
     SYS 0: Not registered
    1: Registered 2
    721 Mainte- nance Service center call function ALL 2
    SYS 0: OFF
    1: Notifies all service 
    calls
    2: Notifies all but  paper jams 1
    723 Mainte- nance Service center call
    HTTP server URL setting ALL - SYS Maximum 256 letters 11
    726 Mainte- nance HTTP proxy setting ALL 1
    SYS 0: Valid
    1: Invalid 1
    727 Mainte- nance HTTP proxy IP address  
    setting ALL - SYS 000.000.000.000-
    255.255.255.255 
    (Default value 
    000.000.000.000) 11
    728 Mainte- nance HTTP proxy port number  
    setting ALL 0
     SYS 1
    729 Mainte- nance HTTP proxy ID setting ALL - SYS Maximum 30 letters 11
    730 Mainte- nance HTTP proxy password set-
    ting ALL - SYS Maximum 30 letters 11
    731 Mainte- nance HTTP proxy panel display ALL 1
    SYS 0: Valid
    1: Invalid 1
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default
     RAM Contents
    Proce-
    dure
    04/09 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 121
    2
    732 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies
    ALL 3
     SYS 0: Ordered by FAX
    1: Ordered by E-mail 
    2: Ordered by HTTP 
    3: OFF 1
    733 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    FAX number ALL - SYS Maximum 32 digits
    Enter hyphen with the 
    [Monitor/Pause] button 11
    734 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    E-mail address ALL - SYS Maximum 192 letters
    List: 256 digits 11
    738 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Users name ALL - SYS Maximum 50 letters 11
    739 Mainte- nance 
    (Remote) Automatic ordering func-
    tion of supplies 
    Users telephone number ALL - SYS Maximum 32 digits
    Enter hyphen with the 
    [Monitor/Pause] button 11
    740 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Users E-mail address ALL - SYS Maximum 192 letters
    List: 256 digits 11
    741 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Users address ALL - SYS Maximum 100 letters 11
    742 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies
    Service number ALL 0
     SYS Maximum 5 digits 11
    743 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Service technicians name ALL - SYS Maximum 50 letters 11
    744 Mainte- nance 
    (Remote) Automatic ordering func-
    tion of supplies 
    Service technicians tele- 
    phone number ALL - SYS Maximum 32 digits
    Enter hyphen with the  
    [Monitor/Pause] button 11
    745 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Service technicians E-mail  
    address ALL - SYS Maximum 192 letters
    List: 256 digits 11
    746 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Suppliers name ALL - SYS Maximum 50 letters 11
    747 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Suppliers address ALL - SYS Maximum 100 letters 11
    748 Mainte- nance 
    (Remote) Automatic ordering func- 
    tion of supplies 
    Notes ALL - SYS Maximum 128 letters 11
    758 Mainte- nance 
    (Remote) Information about supplies 
    Part number of toner car- 
    tridge ALL - SYS Maximum 20 digits 11
    759 Mainte- nance
    (Remote) Information about supplies 
    Order quantity of toner car-
    tridge ALL 1
     SYS 1
    760 Mainte- nance
    (Remote) Information about supplies 
    Condition number of toner  
    cartridge ALL 1
     SYS 1
    764 Mainte- nance
    (Remote) Automatic ordering sup- 
    plies 
    Result table printout ALL 1
     SYS 0: OFF
    1: Always
    2: ON Error 1
    Setting mode (08) 
    Code Classifi-
    cation ItemsFunc-
    tion Default
     RAM Contents
    Proce-
    dure
    04/09 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 122
    765 Mainte-
    nance
    (Remote) Automatic ordering sup- 
    plies 
    Display ALL 2
     SYS 0: Valid (FAX/Internet 
    FAX)
    1: Valid (FAX/Internet 
    FAX/HTTP)
    2: Invalid 1
     767 Mainte- nance
    (Remote) Service Notification setting ALL 0
    SYS Enables to set up to 3 
    E-mail addresses to be  
    sent.(08-768, 777, 778)
    0: Invalid 
    1: Valid (E-mail) 
    2: Valid (FAX) 1
    768 Mainte- nance
    (Remote) Destination E-mail address ALL - SYS Maximum 192 letter
    s 11
    769 Mainte- nance
    (Remote) Total counter information  
    transmission setting
    ALL 0
     SYS 0: Invalid
    1: Valid 1
    770 Mainte- nance
    (Remote) Total counter transmission  
    date setting
    ALL 1
     SYS 1 to 31 1
    771 Mainte- nance
    (Remote) PM counter notification set- 
    ting
    ALL 0
     SYS 0: Invalid
    1: Valid 1
    772 Mainte- nance Dealers name ALL - SYS Maximum 100 letters
    Needed at initial regis- 
    tration11
    773 Mainte- nance Login name ALL - SYS Maximum 20 letters
    Needed at initial regis- 
    tration11
    774 Mainte- nance
    (Remote) Display setting of [Service  
    Notification] button
    ALL 0
     SYS 0: Not displayed
    1: displayed 1
    775 Mainte- nance
    (Remote) Sending error contents of  
    equipment
    ALL 0
     SYS 0: Invalid
    1: Valid 1
    776 Mainte- nance
    (Remote) Setting total counter trans- 
    mission interval 
    (Hour/Hour/Minute/Minute) ALL - SYS 1
    777 Mainte- nance
    (Remote) Destination E-mail address  2
    ALL - SYS Maximum 192 letters 11
    778 Mainte- nance
    (Remote) Destination E-mail address  3
    ALL - SYS Maximum 192 letters 11
    779 Mainte- nance
    (Remote) Notification format selec- 
    tion
    ALL 0
     SYS 0: Text
    1: Text + XML data 1
    780 Mainte- nance Remote-controlled service 
    polling day selection
    Day-1 ALL 0
     SYS 0: OFF
    1 to 31: 1st to 31st of a 
    month 1
    781 Mainte- nance Remote-controlled service  
    polling day selection 
    Day-2 ALL 0
     SYS 0: OFF
    1 to 31: 1st to 31st of a 
    month 1
    782 Mainte- nance Remote-controlled service  
    polling day selection 
    Day-3 ALL 0
     SYS 0: OFF
    1 to 31: 1st to 31st of a 
    month 1
    Setting mode (08) 
    Code Classifi-
    cation Items
    Func-
    tion Default
     RAM Contents
    Proce-
    dure
    04/09 
    						
    							June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
    2 - 123
    2
    783 Mainte- nance Remote-controlled service  
    polling day selection 
    Day-4 ALL 0
     SYS 0: OFF
    1 to 31: 1st to 31st of a 
    month 1
    784 Mainte- nance Remote-controlled service  
    polling day selection
    Sunday ALL 0
     SYS 0: Invalid
    1: Valid 1
    785 Mainte- nance Remote-controlled service  
    polling day selection 
    Monday ALL 0
     SYS 0: Invalid
    1: Valid 1
    786 Mainte- nance Remote-controlled service 
    polling day selection 
    Tuesday ALL 0
     SYS 0: Invalid
    1: Valid 1
    787 Mainte- nance Remote-controlled service  
    polling day selection 
    Wednesday ALL 0
     SYS 0: Invalid
    1: Valid 1
    788 Mainte- nance Remote-controlled service  
    polling day selection 
    Thursday ALL 0
     SYS 0: Invalid
    1: Valid 1
    789 Mainte- nance Remote-controlled service 
    polling day selection
    Friday ALL 0
     SYS 0: Invalid
    1: Valid 1
    790 Mainte- nance Remote-controlled service  
    polling day selection 
    Saturday ALL 0
     SYS 0: Invalid
    1: Valid 1
    794 Mainte- nance Information of supplies set-
    ting of toner cartridge ALL 0
     SYS 0: Invalid
    1: Valid 1
    796 Mainte- nance Remote-controlled service 
    lengthened interval polling 
    (End of month) ALL 0
     SYS 0: Invalid
    1: Valid 1
    797 Mainte- nance Firmware download ALL 0
    SYS 0: Accepted
    1: Prohibited 1
    798 General Notifying address of trial  period end PRT/
    SCN 3
     SYS Sets where the end of 
    the trial period is to be 
    notified.
    0: OFF 1: User 
    2: Service center 
    3: User and service 
    center 1
    799 General Forcible end of trial period PRT/ SCN- SYS [CANCEL]: Cancel
    [EXECUTION]: Forc- 
    ible end 
    When the “Forcible end  
    of trial period” is per- 
    formed, “0” is set in the  
    code (08-673) to end up  
    the trial period forcibly. 3
    800-0 Fuser Temperature  control lower  
    limit 
    (OHP film)Center  
    themistor
    ALL 8
     M 0:  130°C  1: 135°C
    2:  140°C 3: 145°C 
    4:  150°C 5: 155°C 
    6:  160°C 7: 165°C 
    8:  170°C  9: 175°C 
    10: 180°C 
    11: 185°C 
    12: 120°C 4
    800-1 Side  themistorALL 6
     M 4
    Setting mode (08) 
    Code Classifi-
    cation Items
    Func-
    tion Default
     RAM Contents
    Proce-
    dure
    05/05 
    						
    							e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
    2 - 124
    801-0 Fuser Temperature 
    control lower  
    limit  
    (Thick paper 
    1)Center 
    themistor
    ALL 8
     M 0:  130°C 1: 135°C  
    2:  140°C 3: 145°C   
    4:  150°C 5: 155°C 
    6:  160°C 7: 165°C  
    8:  170°C 9: 175°C   
    10: 180°C   
    11: 185°C
    12: 120°C 4
    801-1 Side  themistorALL 6
     M 4
    802-0 Fuser Temperature  control lower  
    limit
    (Thick paper  
    2)Center 
    themistor
    ALL 8
     M 0:  130°C   1: 135°C  
    2:  140°C 3: 145°C   
    4:  150°C   5: 155°C
    6:  160°C   7: 165°C   
    8:  170°C 9: 175°C   
    10: 180°C  
    11: 185°C 
    12: 120°C 4
    802-1 Side  themistorALL 9
     M 4
    803-0 Fuser Temperature  control lower  
    limit 
    (Thick paper  
    3)Center 
    themistor
    ALL 8
     M 0:  130°C   1: 135°C  
    2:  140°C 3: 145°C   
    4:  150°C  5: 155°C 
    6:  160°C   7: 165°C   
    8:  170°C 9: 175°C  
    10: 180°C   
    11: 185°C 
    12: 120°C 4
    803-1 Side  themistorALL 10
     M 4
    804-0 Fuser Temperature  control lower  
    limit 
    (Envelope)Center  
    themistor
    ALL 8
     M 0:  130°C   1: 135°C  
    2:  140°C 3: 145°C   
    4:  150°C   5: 155°C 
    6:  160°C   7: 165°C   
    8:  170°C 9: 175°C  
    10: 180°C   
    11: 185°C 
    12: 120°C 4
    804-1 Side  themistorALL 10
     M 4
    805 Charger Main charger bias correc- tion 
    (Text/Photo/OHP film) PRT 98
     M Corrects the value of 
    the main charger bias 
    adjustment (05-210). 1
    806 Charger Main charger bias correc- tion 
    (Toner Saving Mode/OHP  
    film) PRT 98
     M 1
    807 Charger Main charger bias correc- tion 
    (Text/Photo/OHP film) PPC 98
     M 1
    808 Charger Main charger bias correc- tion
    (Text/OHP film) PPC 98
     M 1
    809 Charger Main charger bias correc- tion 
    (Photo/OHP film) PPC 98
     M 1
    826 Charger Main charger bias correc- tion 
    (Toner saving mode) PRT 128
     M 1
    830 Transfer Transfer transformer DC  correction (C) ALL 128
     M Corrects the value of 
    the transfer trans- 
    former DC output 
    adjustment (05-221). 1